WELCOME TO PRESENTATION ON WATER QUALITY SYSTEMS
WATER INFRASTRUCTUREA
AET
I
Water Treatment
Water Transport
Water Sources
Wastewater Treatment
Wastewater Transport
Water Transport
Water Transport
Drivers
Depleting Water Supply
Tightening Regulations
Aging Infrastructure
Water Pollution Climate change
Water Usage
AA
ETI Technology Available for Online
Water Quality Monitoring
Electrode Method UV-Vis Spectro-photometry (Entire spectrum scanning
200-750nM) UV-Vis Spectro-photometry (Single wavelength
254nM) Combined Combustion Catalytic Oxidation at 680°C
and NDIR Method (TOC) Scattered Light IR Method Ion Selective Electrode Method with temp correction
*NOTE – OUR TECHNOLOGY IS ISO 9001-2008, TUV CERTIFIED.
AA
ETI
Calculating concentration:
1. Recording spectral absorbance.
2. Calculation of concentrations according to algorithms.
Algorithms based on correlations with reference measurements are stored
in the sensor.
COD, TOC, BOD, NO3-N, TSS
mg/lalgorithms
Measuring Principle
4
• The UV Vis is programmed with algorithms based on correlation data that has been taken from different sites, application and during different times of the year.
• The sensor records the spectral absorbtion, compares it to the stored algorithms and then calculates the concentration of the analyte.
AA
ETI
abso
rban
ce
wavelength
2
The Spectral absorbance differs in each stage of the
wastewater process, from application to application,
and from site to site.
abso
rban
ce
wavelength
abso
rban
ce
wavelength
Activated Sludge EffluentInfluent
Spectral Absorbance in the Process
5
AA
ETI
UV-Vis Spectro-photometry (Entire spectrum scanning)
• UV Visible Spectrometry use the full spectrum involving measurement of organics over the entire spectrum starting from 200 nm to 750 nm with adaptive ranging capabilities.
• The system takes care of single bond organics also. Any change in matrix needs recalibration of the system to assess the factor for determination of COD & BOD.
• Preferred tools such as multi-wavelength dual beam scanning in UV-Visible range with library of industrial matrices in analyser with multi-point local adaptive calibrations help to have matrix change adaption seems better for analyser. The measured values are determined from the spectral data .
• The calculation is based on methods and characteristics that were achieved from a multitude of measurement and long time analysis and the observation from UV spectra.
• Thus, correlations vary with the change in waste matrix and these characteristics need to be frequently established in the beginning for better data quality the actual values monitoring using laboratory technique.
AA
ETI UV-VIS Spectrophotometer Sensor
200 nm 720 nm
Measures broad spectrum:
From ultraviolet (UV) to
visible (VIS) light
7
The UV-VIS is a spectrophotometer that is extremely rugged and corrosion
resistant making it suitable for harsh applications. The UV VIS can measure
TSS, Nitrate, COD, BOD, TOC, Dissolved organic carbon and the spectral
absorption coefficient. The UV Vis measures the sample’s absorption of light across the total spectrum of light from ultraviolet to visible light. This is unique as most spectral sensors only measure at one wavelength.
COD: 0-700 mg/l BOD: 0-400 mg/l TOC: 0-400 mg/l TSS: 0-600 mg/l
MEASURING PARAMETERS IN WATER
• COD- Chemical Oxygen Demand• BOD- Biochemical Oxygen Demand• TOC – Total Oxidized carbon• TSS - Total Suspended Solids• PH / ORP – Oxygen Reduction PH• CONDUCTIVITY – Anion & Cation• DISSOLVED OXYGEN• AMMONIUM NITRATE• TURBIDITY
NOTE – All sensor probes are TITANIUM -MOC suitable for all type of harsh environment.
AA
ETI
Relation between COD,BOD &TOC • COD or Chemical Oxygen Demand is the total measurement of all
chemicals (organics & in-organics) in the water / waste water
• BOD is a measure of, the amount of oxygen that require for the bacteria to degrade the organic components present in water / waste water.
• The ratio of BOD/COD is about COD is higher than that of BOD maximum of up to 4 times in medium scale industries; but it varies based on the industrial process and nature of the raw materials used.
• TOC - measures the amount of carbon bound to organic compound, hence the relation between COD and TOC will be directly proportional to each other.
• The study concludes that TOC can be reliably used for the generic replacement of both COD (COD=49.2+3.00*TOC) and BOD (BOD=23.7+1.68*TOC) in influent wastewaters but only for COD (COD=7.25+2.99*TOC) in final effluents.
AA
ETI
AA
ETI
pH / ORP
Conductivity
Turbidity / Susp. Solids
ISE:
Ammon
ium
- Nitrate
Dissolved
Oxygen
Optically:
- Nitrate
COD, BOD…
IQ Sensors
10
TECHNOLOGY/PRINCIPLE USED FOR MEASURING WATER PARAMETERS
• Optical DO Sensor
AA
ETI
• Optical DO sensor utilizing• Super-stable• Green source light• No flow required• Soft excitation light• Minimum aging of sensor cap• No bleaching affect on sensor
cap• 2 year warranty on sensor and
membrane cap• Highly accurate, +/- 0.1 mg/L• No regular sensor
maintenance required
Intelligent Sensor Cap
• Factory calibrated
• Cal data stored on memory chip
• Automatic data transfer
• No calibration required!
AA
ETI
•
Details for DO sensor
12
- Measuring Principle: Optical
- Measurement Range: 0.00 -20.00 mg/l DO or : 0-200%
Saturation
- Resolution: 0.01 ml or 0.1%
- Response time: T90 Equivalent of less than 60 Secs
- Signal Output –Digital
- Power Consumption: less than 1 Watt
- Temp Compensation: -5 to +50 Deg C
- Max Pressure for Sensor: 10 Bar
- Input Power: Powered by the Controller
- Transient Voltage Protection should be integrated in the
sensor
- Material of Construction should be Titanium or equivalent
- Protection type : IP 68 for both Sensor and Cable
• It is an electrode based sensor detecting the mV relating it with PH level from 0 to 14 & ORP is expressed in -2000mv to +2000mv.
AA
ETI
•
• Measuring Range: pH – 0.00- 14.00
• Signal Output –Digital
• Sensor Check function should be available in the pH sensor
• Power Consumption: less than 0.5 Watt
• Temperature Sensor should be integrated in the pH sensor
• Temp Compensation: -5 to +50 Deg C
• Max Pressure for Sensor: 10 Bar
• Max Pressure for Sensor Cable: 10 Bar
• Transient Voltage Protection should be integrated in the sensor
• Sensor body: Titanium or Sea Water Version
• protection type : IP 68 for both Sensor and Cable
• The Sensor cable supplied along with the sensor has to be up to 100 Meters and of Sea Water version so that it’s not affected by acids and presence of highly corrosive media in sample.
pH/ORP
13
AA
ETI TSS and Turbidity
14
Optical Total Suspended
Solids (TSS) and
Turbidity Probes• Factory calibrated for 2
types of sludge:
Activated sludge 3 - 7 g/L
Primary sludge 30 - 60 g/L
• Calibration: 1 – 8 pt
• Correction factor: x 0.5 – 2
• Factory calibrated
• Calibration free
• Offset (+/- NTU)
AA
ETI
•
Principle of TSS/Turbidity
15
• Turbidity/TSS is a quantitative measure of remaining undissolved solids in water,
• It measures by 90 degree scattered light principle, passing of optical radiation through a dispersing system dispersed solids reduce radiation power by transforming it to one form of energy, called as absorption,
• the ratio of penetrating to emitting light beams is measured as turbidity,
• for lower concentration scattered light principle, for higher concentration back scatter method.
• Expressed in nephelometric turbidity (NTU) & FNU (Formazin nephelometric unit)
AA
ETI UltraClean – Ultra Sonic Cleaning
16
without cleaning system (30 days)with cleaning system (30 days)
A clean sensor ensures accurate measurements!
Maintenance-free sensor lowers ownership and operational
costs.The UltraClean system is very effective at removing all types of fouling, dirt, biofilms, ect. It can even help avoid lime precipitation. Here are two sensors from a side by side trial. Both were deployed for 30 days, the one on the left without the ultraclean and the one on the right with the Ultraclean. AS you can see, the UltraClean system kept clean for 30 days resulting in better data for better decision making.
NOTE; Cycle of Ultrasonic Cleaning is Every One Minute automatically .
AA
ETI ULTRASONIC CLEANING VIDEO
17
• We are using entire spectrum scanning technology measuring from 200nm to 750 nm other than single wavelength scanning making it more productive.
• No chemicals required other than chemicals requirement like sulphuric acid, distilled water etc.
• Response time is in seconds other than taking time in minutes.
• Sensor is IP68 rated best in class.
• Sensor Probes life is more than 10 year.
• Ultrasonic cleaning technology.
• Technology is plug & play with globally & local calibration.
• All matrix change & configuration is auto feeded can not be deleted.
• Rugged & reliable sensor make for waste water sites, no aging of sensor due to mechanical damage & contamination.
• Spectrophotometric sensor are shock proof no chance of danger to the person handling it.
• With our technology we can add maximum 20 sensor with 1 controller.
• Communication via modem, Bluetooth, radio transmission, PROFIBUS, MODBUS, RS-232
• One cable for power & communications.
AA
ETI BENEFITS WITH THIS TECHNOLOGY
18
• Aluminium
• Cement
• Distilleries
• Dye & Dye intermediate/Chlor alkali
• All type of fertilizer/Urea plants
• Iron & Steel
• Oil Refineries
• Petrochemical
• Pesticides
• Pharmaceuticals
• Power plant
• Pulp & paper
• Sugar
• Food and Feed Industries
• Tannery
• Zinc & Copper
• Textiles & bleaching
• Diary industries
• FMCG sector
AA
ETI APPLICATION FIELD
19
ABOUT US
• We Nevco Engineers Pvt. Ltd. is the market leader to supply the onlinemonitoring systems for Ambient Air Quality Monitoring System / ContinuesEmission Monitoring systems/ Online & Offline Ash and Coal Analyzer / Online& Offline Cement Analyzer / Effluent Water Quality Monitoring System/ Hugerange of Portables etc..
• We have end to end solution to compliance the CPCB / SPCB’s guidelines.We have our own cloud server as www.nevcocpcb.com for data transfer of alltype of real time monitoring systems.
• We are one of the leading Hardcore Instrumentation company for supplyingdifferent type of Instruments . We have our Head Office in Delhi. Weestablished 14 Regional offices across India to serve the services to all ourmillions of clients.
• We have more than 95 Sales and Service Engineers responsible for sale,installation, commissioning, servicing and calibration of all instruments whichwith we deals.
• BEST SERVICE SUPPORT IS OUR MAJOR AGENDA TO MAKES HAPPYOUR ALL CLEINTS.
AA
ETI
MAJOR PRODUCT PROFILE
1. Ambient Air Quality Monitoring System > OPSIS , SWEDEN (DOAS)
2. Ambient Air Quality Monitoring System > AEROQUAL (Low Cost )
3. Stack Emission Monitoring System > OPSIS , SWEDEN (DOAS)
4. Effluent Water Quality Monitoring > WTW( Xylem) , German
5. Online & Offline Ash & Coal Analyzer > DFMC , CHINA
6. Online Elemental Analyzer For Coal and Cement > DFMC , CHINA
7. Online Moisture Analyzer / Online Radar Level Meter> DFMC, CHINA
8. Online SPM Analyzer > Dynoptics (U.K.) , Opacity Technology
9. Online SPM Analyzer > Sintrol (Finland) , Triboelectric Technology
10. Automatic Kjeldahl System (N/P) Analyzer> OPSIS LiquidLine, Sweden
11.Automatic Fat Extraction System > OPSIS LiquidLine , Sweden
AA
ETI
OUR BRANCHES ALL OVER INDIAA
AET
I
AREA OF EXPERTISEA
AET
I