HII Compact: installs off the floor, out of the way, in any position. 2 connections: plant air in, amplified air out. (Pilot air connection is optional for start-stop control with a PCV valve or solenoid valve and pressure switch.) Can replace a dedicated air compressor: 10 HP size in a typical large plant spot requirement for 100 PSI when only 80 PSI is available. (Model 5A-DS-2) Replace bottled nitrogen: up to 700 PSI (48.3 BAR) for air testing, lab or production. (Model 5A-DS-5 & 7A-DS-8) TYPICAL APPLICATIONS • Valve actuators • Air starters • Bin vibrators • Pneumatic drill motors • Air clamps • Air brakes • Off road tires • Pneumatic nailers, staplers, strapping machines • Air/oil hoists • Air presses FEATURES • BENEFITS • APPLICATIONS AA500C Hydraulics International air driven air pressure amplifiers operate using the principle of differential areas. Like any air tool,they operate from a single shop air connection for most applications. The air used for cycling exhausts through the muffler provided, or may be piped out of the area. The rest of the air is compressed to a higher pressure output. When output demand stops, the unit will stall in a force balanced condition consuming no power nor generating any heat. When output demand resumes, the unit automatically responds and cycles at the rate needed to meet that demand, up to the units capacity. Output Flow Reaches Maximum as the amplifier’s output pressure approaches the plant air input pressure. Output Flow Drops to Zero as the unit reaches theoretical stall. This value is estimated by multiplying input pressure x the last digit of the model number, e.g. model 5A-DS-5 with 100 PSI (6.9 BAR) plant air input will stall at approximately 500 PSI, model 5A-DS-2 at approximately 200 PSI (13.8 BAR). In practice however, controlling the maximum pressure desired is usually done with an external control. AIR DRIVEN AIR PRESSURE AMPLIFIERS 1 (818) 407 - 3400 got pressure? HII INSTALLATION AND CONTROLS Although there are a number of options for controlling these units, a final recommendation will be based on how the high pressure output air is to be used. Perhaps the most common type of control is that similar to a conventional air compressor: 1. Amplify the air into a receiver tank, ASME coded if permanently mounted. 2. Provide a safety relief valve at maximum rated tank pressure. 3. Provide a pressure switch* set to stop the air amplifier unit at about 95% of safety relief valve setting. 4. Provide an air or gas regulator (reducing valve) on the tank output set at the minimum usable amplified air pressure for the application. * The pressure switch need not be electrical. Instead, the HII series of PCV valves performs this function in one simple unit with no electrical input required. Hydraulics International, Inc.

AA500C HII AIR DRIVEN AIR PRESSURE AMPLIFIERS

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

HII

• Compact: installs off the floor, out of the way, in any position.

• 2 connections: plant air in, amplified air out. (Pilot air connection is optional for start-stop control with a PCV valve or solenoid valve and pressure switch.)

• Can replace a dedicated air compressor: 10 HP size in a typical large plant spot requirement for 100 PSI when only 80 PSI is available. (Model 5A-DS-2)

• Replace bottled nitrogen: up to 700 PSI (48.3 BAR) for air testing, lab or production. (Model 5A-DS-5 & 7A-DS-8)

TYPICAL APPLICATIONS

• Valve actuators • Air starters • Bin vibrators • Pneumatic drill

motors • Air clamps • Air brakes • Off road tires

• Pneumatic nailers, staplers, strapping machines

• Air/oil hoists • Air presses

FEATURES • BENEFITS • APPLICATIONS

AA500C

Hydraulics International air driven air pressure amplifiers operate using the

principle of differential areas. Like any air tool,they operate from a single shop air

connection for most applications. The air used for cycling exhausts through the muffler provided, or

may be piped out of the area. The rest of the air is compressed to a higher pressure output.

When output demand stops, the unit will stall in a force balanced condition consuming no power nor

generating any heat. When output demand resumes, the unit automatically responds and cycles at the rate

needed to meet that demand, up to the units capacity.

Output Flow Reaches Maximum as the amplifier’s output pressure approaches the plant air input pressure. Output

Flow Drops to Zero as the unit reaches theoretical stall. This value is estimated by multiplying input pressure x the

last digit of the model number, e.g. model 5A-DS-5 with 100 PSI (6.9 BAR) plant air input will stall at approximately 500 PSI,

model 5A-DS-2 at approximately 200 PSI (13.8 BAR). In practice however, controlling the maximum pressure desired is usually

done with an external control.

AIR DRIVENAIR PRESSURE

AMPLIFIERS

(818) 407 - 3400 1(818) 407 - 3400

got pressure?HII

INSTALLATION AND CONTROLSAlthough there are a number of options for controlling these units, a final recommendation will be based on how the high pressure output air is to be used. Perhaps the most common type of control is that similar to a conventional air compressor:

1. Amplify the air into a receiver tank, ASME coded if permanently mounted.

2. Provide a safety relief valve at maximum rated tank pressure.

3. Provide a pressure switch* set to stop the air amplifier unit at about 95% of safety relief valve setting.

4. Provide an air or gas regulator (reducing valve) on the tank output set at the minimum usable amplified air pressure for the application.

* The pressure switch need not be electrical. Instead, the HII series of PCV valves performs this function in one simple unit with no electrical input required.

Hydr

aulic

s In

tern

atio

nal,

Inc.

STANDARD SYSTEMS

Description: The air pressure amplifier unit includes model 5A-DS-2 and it is a complete pneumatic system designed to provide double the available plant air pressure and momentary high flow. Tank is 15-gallon, 200-PSI (13.8 BAR) ASME code. The regulator on the tank outlet is provided to control the output pressure and flow. Tank relief valve is set at 200-PSI (13.8 BAR).

Primary Applications: Assist air powered tools and machines in large plants with marginal central air pressure systems. Ideal to boost plant air pressure in tools for operation of automatic clamps, cylinders and other equipment.

Approximate Dimensions:

40” L x 17” D x 26” H(1016 x 432 x 660) mm

Description: This compact air pressure amplifier unit includes model 3A-SS-2.5 or 3A-SS-4 and it is a complete pneumatic system designed to provide 2.5x or 4x the available plant air pressure. Tank is approximately 1-gallon, D.O.T. code steel bottle. The inlet drive air regulator is provided to control the output pressure up to 675-PSI (46.6 BAR).

Primary Applications: Assist smaller air powered tools and machines with marginal shop air pressure. Ideal for light duty, miscellaneous testing, and boosting into tight spaces.

Approximate Dimensions:

11” L x 11” D x 17” H(279 x 279 x 432) mm

Description: This air pressure amplifier unit includes model 5A-DS-5 and it is a complete pneumatic system designed to provide 5x the available plant air pressure and momentary high low. Tank is 5-gallon, 600-PSI (41.4 BAR) ASME code. The regulator on the tank outlet is provided to control the output pressure and flow. Tank relief valve is set at 600-PSI (41.4 BAR).

Primary Applications: Pressure testing with plant compressed air up to 5x air in up to 500 PSI (34.5 BAR) with moderate flow or special devices. Ideal to boost plant air pressure in tools for operation of automatic clamps cylinders and other equipment.

Approximate Dimensions:

17” L x 15” D x 23” H(432 x 381 x 584) mm

Model HIS-10001

Model HIHP-10044 or HIHP-10045

Model HIS-10002

Model HIS-10003Dual Air Amplifier System

Description: This dual air amplifier system provides increased efficiency, flow and pressure. It consists of a model 5A-DS-2X piped into model 5A-DS-5X for a 2-stage configuration. Tank is 15-gallon, 400-PSI (27.6 BAR) ASME code. Tank pressure is controlled with a pilot cutoff valve (PVC), and is rated for a maximum pressure of 390-PSI (26.9 BAR). This system is assembled, completely tested for maximum flow and pressure, and mounted on a rigid fork-lift-able steel frame with control panel.

Primary Applications: Pressure testing, purging, clamping with plant compressed air up 390-PSI (26.9 BAR) with high flow.

Approximate Dimensions:

28” L x 30” D x 43” H(711 x 762 x 1092) mm

2 (818) 407 - 3400

(0.28) (0.57) (0.85) (1.13) (1.42) (1.70) (1.98) (2.27) (2.55) (2.83) (3.12) (3.40)

(82.8)

(62.1)

(41.4)

(20.7)

1200

900

600

300

OUTLET FLOW - SCFM (M3/M)

(BAR)

200 (13.8)

150 (10.3)

100 (6.9)

75 (5.2)

50 (3.5)

800 (55.2)

APPROXIMATE AIRDRIVE PRESSURE = 95 PSI (6.6 BAR)

MAXIMUM CYCLE RATE130 CPM APPROX

performance

(13.8)(13.1)(12.4)(11.7)(11.0)(10.3)(9.7)(9.0)(8.3)(7.6)(6.9)(6.2)(5.5)(4.8)(4.1)(3.5)(2.8)(2.1)(1.4)(0.7)

200190180170160150140130120110100908070605040302010

25 50 75 100 125 (0.71) (1.42) (2.12) (2.83) (3.54)

OUTLET FLOW - SCFM (M3/M)

100 (6.9)95 (6.6)

90 (6.2)85 (5.9)

80 (5.5)

75 (5.2)

70 (4.8)65 (4.5)

MAXIMUM CYCLERATE 70 CPMAPPROX.

INLET PRESSURES,PSI (BAR) TO THE UNITBOTH DRIVE ANDBOOST SECTIONS

performance

OU

TLET

PR

ESSU

RE

- PSI

(BA

R)

2.50 5 7.5 10

A

BC

AIR INLET, PSI (BAR)400

300

200

100

(27.6)

(20.7)

(13.8)

(6.9)

(0) (0.07) (0.14) (0.21) (0.28)

3A-SS-2.5 3A-SS-4

1.50 3 4.5 6

AB

C

AIR INLET, PSI (BAR)150 (10.3)

125 (18.6)

100 (6.9)

75 (5.2)

50 (3.5)

100

200

300

400

500

600 (41.3)

(34.5)

(27.6)

(20.7)

(13.8)

(6.9)

(0) (0.04) (0.08) (0.13) (0.17)

OUTLET FLOW - SCFM (M3/M)

150 (10.3)

125 (18.6)

100 (6.9)

75 (5.2)

50 (3.5)

installation 3A-SS-2.5 and 3A-SS-4

installation 5A-DS-5

Note: 1 The 3A Series is recommended for lower flow, intermittent duty and, due to its compact size, is suitable for OEM installations (with a small receiver) to ensure proper machine operation where the air supply may be marginal.

installation 5A-DS-2

performance

BASIC DATA

(818) 407 - 3400 3(818) 407 - 3400

Boost DisplacementPer Cycle

Maximum Pressure

Model No.Weight Drive Section Boost Section

LBS KG IN3 CM3 PSI BAR PSI BAR3A-SS-2.51 7 3.2 2.66 43.6 150 10.3 400 27.6

3A-SS-41 7 3.2 1.60 26.2 150 10.3 675 46.6

5A-DS-2 36 16.4 202.8 3323.3 150 10.3 300 20.7

5A-DS-5 30 13.6 24.1 394.9 150 10.3 1250 86.2

7A-DS-8 50 22.7 41.4 678 150 10.3 1250 86.2

AIR DRIVEN GAS BOOSTERS■ Boosts pressure from 50 PSI (3.4 BAR) to 30,000 PSI (2068 BAR)■ Airline lubrication not required■ Lightweight, one-man portable■ Corrosion resistant including offshore environment■ Self-cooling using own exhaust air■ No electrical connections needed■ Wide range of models: single acting, double acting, two stage and double air drive configuration

AIR DRIVEN LIQUID PUMPS■ Self lubricating■ No electrical power needed■ Portable, lightweight and economical■ Wide range of models in 3”, 5 3/4” and 7” drive sizes■ Pressures up to 80,000 PSI■ All models are rated for plain water or oil■ Ideal for OEM applications

QUICK REFERENCE: INTERNATIONAL EQUIVALENTSVOLUME1 LITRE = 61 IN3 = .26 U.S. GAL1 NM3 = 35.3 SCF

WEIGHT1 Kg = 2.2 LBSLENGTH1 IN = 25.4 mm

PRESSURE1 BAR = 14.5 PSI = 1.02 Kg/cm2 = 100 Kpa = .986 ABSOLUTE ATM1 Mpa = 10 BAR = 1000 Kpa1 ABSOLUTE ATM = 14.7 PSIA = 0 PSIG

OTHER HII QUALITY PRODUCTS Our products are designed, sourced & manufactured in the USA.

© HYDRAULICS INTERNATIONAL, INC. 2015

www.hiigroup.com

performanceinstallation 7A-DS-8

5L-SD -60 THRU -600 & 5L-ST -900

1

21.34”1 18.60”2

ALL OTHER DIMENSIONS REMAIN AS ILLUSTRATED.

5L -ST -900 ONLY

2

OUTLET FLOW - SCFM (M3/M)

OU

TLET

PR

ESSU

RE

- PSI

(BA

R)

3AA B C

5 SCFM 10 SCFM 15 SCFM

0.14 M3/M 0.28 M3/M 0.42 M3/M

5A-DS-2A B C

40 SCFM 60 SCFM 75 SCFM

1.13 M3/M 1.7 M3/M 2.12 M3/M

7AA B C

45 SCFM 105 SCFM 165 SCFM

1.27 M3/M 2.9 M3/M 4.6 M3/M

5A-DS-5A B C D

15 SCFM 30 SCFM 50 SCFM 75 SCFM

0.42 M3/M 0.84 M3/M 1.41 M3/M 2.12 M3/M

■ How the Pump Works, Advantages of the HII Pumps, How to Select Air Driven Pumps .........................................................2

■ Typical Applications .............................................................................3

■ Model Selection Table ..........................................................................4

■ Type of Materials in Contact with Fluid, Liquid Compatibility and Operating Temperature Limits .....................................................5

■ Dimensional Data, Port Details .......................................................6, 7

CONTENTS

LP500D

AIR DRIVEN AIR DRIVEN LIQUID PUMPSLIQUID PUMPS

HIIHy

drau

lics

Inte

rnat

iona

l, In

c.

■ Performance Curves ............................................................8, 9, 10, 11

■ Compressibility of Water ...................................................................11

■ Standard Modifications .....................................................................12

■ HII Power Units .................................................................................13

■ Other HII Quality Products .................................................................14

■ Hydraulics International, Inc. - Overview .........................................15

• Principle of Operation, Benefits, Features, Typical Gas Booster Applications 2• Why Use Air Driven Gas Boosters?, International Equivalents 3• How Do Buyers Choose Between Gas Booster Models? 3, 4• Determining the Proper Gas Booster Model—Examples 4, 5• Gas Booster Selection Table and Notes 6, 7, 8• How to Use the Performance Curves 9• Performance Curves 10, 11, 12• Installation Dimensions, Weights 13, 14 • Standard Modifications 15 • Hydraulics International, Inc. Overview 15• Other HII Products 16

CONTENTS:

Chatsworth, California, USA

AIR DRIVENAIR DRIVENGAS BOOSTERS

GB500C

got pressure?HII

9201 Independence Avenue, Chatsworth, CA 91311 USATel: (818) 407-3400 | Fax: (818) 407-3428 | Email: [email protected]

AIR DRIVE CONSUMPTION

7A-DS-8