Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
1AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016FEATURES
For specific product applications,Consult your Kawneer representative.
Features• AATM250 narrow stile has 2-1/2" (62.5) vertical stiles, 2-1/2" (62.5) top rail, and 3-7/8" (98.4)
bottom rail• AATM425 wide stile has 4-1/4" (108) vertical stiles, 4-1/4" (108) top rail, and 6-1/2" (165.1)
bottom rail• Door is 2-1/4" (57.2) deep• Door has 1/8" (3.2) typical wall thickness• Dual welded corner construction• Polyamide thermal break• Single acting• 1" (25.4) insulated glass infill• Offset pivots, butt hinges or continuous geared hinge• MS locks or exit device hardware• Surface mounted or concealed closers• Architects Classic push/pulls• Meeting stile astragal has dual pile weathering with polymeric fin• Polymeric bulb weatherstripping and pile weathering with polymeric fin in door frame• PermanodicTM anodized finishes in seven choices• Painted finishes in standard and custom choices
Optional Features• Variety of top, bottom, and cross rails• Two color finish capability
Product Applications• AATM250 - engineered for thermal efficiency in moderate traffic applications such as offices,
stores, and apartment buildings• AATM425 - engineered for thermal efficiency and added strength for schools, institutions and
other increased traffic applications
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
2 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016BLANK PAGE
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
3AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016INDEX
PICTORIAL VIEW ................................................................................5DOOR TYPES/SECTION DIMENSIONS .............................................6AATM250 THERMAL ENTRANCE CONSTRUCTION DETAILS ..........7TRIFABTM VG 451T CENTER DOOR FRAMES .............................. 8-9ENTRANCE OFFERING ...............................................................10-11PUSH PULL HARDWARE .................................................................12EXIT DEVICES ...................................................................................13OPTIONS AND ACCESSORIES ........................................................14THERMAL CHARTS .................................................................... 15-27
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted.
The following metric (SI ) units are found in these details: m – meter cm – centimeter mm – millimeter s – second Pa – pascal MPa – megapascal
Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
4 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016BLANK PAGE
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
5AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016PICTORIAL VIEW
#1 MECHANICAL FASTENING is accomplished by attaching a 5/16" (7.9) thick extruded aluminum channel clip to the vertical stile with 1/4"-20 heat strengthened bolts and 3/16" thick steel nut plates for a high strength welding base for attachment horizontal member.
#2 SIGMA* DEEP PENETRATION PLUG WELDS are made top and bottom after the horizontal is properly positioned over the channel clip to help provide the strongest door corner joint currently available.
#3 SIGMA* FILLET WELDS along both top and bottom webs of the rail extrusion complete the Dual Welded corner construction.
* An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG).
DUAL MOMENT WELDED CORNER CONSTRUCTION
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
3
2
1
44-5
/16"
(112
5.5)
40-1
3/16
"(1
036.
6) 4 3
2
1
44-5
/16"
(112
5.5)
41-9
/16"
(104
2.0)
1686
= 4
0" (
1016
)
1786
= 4
0" (
1016
)
8600
= 4
1-11
/16"
(10
58.9
)
8400
= 4
0-13
/16"
(10
36.6
)
1690
= 4
0-5/
8" (
1031
.9)
1790
= 4
1-5/
16"
(104
9.3)
4
2
3-7/
8"(9
8.4)
3
2-1/2"(63.5)
9/16"(14.3)
2-1/
4"(5
7.2)
4
2-1/2"(63.5)
12-1/
2"(6
3.5)
9/16
"(1
4.3)
2-1/4"(57.2)
2
6-1/
2"(1
65.1
)
3
4-1/4"(108)
4
4-1/4"(108)
14-1/
4"(1
08)
6 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016DOOR TYPES/SECTION DIMENSIONS
250 MEDIUM STILE 425 WIDE STILE
SCALE 3" = 1' 0"
STANDARDLOCATIONS
STANDARDLOCATIONS
TYPICAL
TYP
ICA
L
TOPATTACHMENT
BOTTOMOF DOOR
OF CYL.CL
TOPATTACHMENT
BOTTOMOF DOOR
PANIC LOCKCYLINDER
CL
STANDARDEXIT DEVICE
OF
CR
AS
H B
AR
FO
R K
AWN
EE
R
STA
ND
AR
D E
XIT
DE
VIC
EC L
TYP
ICA
L
OF
CR
AS
H B
AR
FO
R
AD
AM
S R
ITE
C L
OF
CR
AS
H B
AR
FO
R
FALC
ON
C L
TYPICAL
LOCK STILE LOCK STILEPIVOT STILE PIVOT STILE
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
1
1A 3
5
7 7
5
7
211A
11A
33A
11A
3211A
4 4
7
6 666
7AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016AATM250 THERMAL ENTRANCE CONSTRUCTION DETAILS
5TRANSOM HEAD
6DOOR HEADER/TRANSOM BAR
7*BOTTOM RAIL
*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.
SCALE 3" = 1'-0"
4TRANSOM
INSERT
AATM250 THERMAL ENTRANCE DOORS SINGLE ACTING
TRIFABTM VG 451T CENTER DOOR FRAMES SHOWNNOTE:1. MEDIEM STILE AATM250 THERMAL ENTRANCES ARE DETAILED, WIDE STILE AATM425 THERMAL ENTRANCES ALSO MAY BE USED.2. TRIFABTM VG 451T CENTER, 2" X 4-1/2" (50.8 X 114.3) FRAMING IS DETAILED WITH THE DOORS FOR REFERENCE. OTHER KAWNEER FRAMING SERIES OR CURTAIN WALL SYSTEMS MAY BE USED. REFER TO THE CATALOG INDEX FOR THE APPROPRIATE DETAIL SECTION.
2PAIR OF SINGLE ACTING DOORS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
1/8"
(3.2
)2"
(50.
8)
2"
(50.
8)11
/16"
(17.
5)
1/8"
(3.2
)
1-1/
8"
(28.
6)
2"
(50.
8)
11/1
6"
(17.
5)
3/8"
(9.5
)
8 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016TRIFABTM VG 451T CENTER DOOR FRAMES
SCALE 3" = 1'-0"
TRIFABTM VG 451T CENTER DOOR FRAMES
MA
SO
NR
Y O
PE
NIN
G
FRA
ME
DIM
EN
SIO
N
DO
OR
OP
EN
ING
MA
SO
NR
Y O
PE
NIN
G
FRA
ME
DIM
EN
SIO
N
DO
OR
OP
EN
ING
SINGLE ACTING DOOR WITHOUT TRANSOM
SINGLE ACTING DOOR WITH TRANSOM
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
2"
(50.8)
3/32"
(2.4)
1/4"
(6.4)
2"
(50.8)
3/32"
(2.4)
2"
(50.8)
5/16"
(7.9)
9AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016TRIFABTM VG 451T CENTER DOOR FRAMES
SCALE 3" = 1'-0"
MASONRY OPENING
FRAME DIMENSION
DOOR OPENING
SINGLE ACTING DOOR
MASONRY OPENING
FRAME DIMENSION
DOOR OPENING
CONTINUOUS HINGE JAMB
STANDARD SIZES (TRIFABTM VG 451T CENTER FRAMES)WITHOUT TRANSOM Door Opening Dimension Overall Frame Dimension Masonry Opening Dimension 3' 0" x 7' 0" ( 914 x 2134) 3' 3-1/2" x 7' 1-3/4" (1003 x 2178) 3' 4" x 7' 2" (1016 x 2185)3' 6" x 7' 0" (1067 x 2134) 3' 9-1/2" x 7' 1-3/4" (1156 x 2178) 3' 10" x 7' 2" (1168 x 2185)6' 0" x 7' 0" (1829 x 2134) 6' 3-1/2" x 7' 1-3/4" (1918 x 2178) 6' 4" x 7' 2" (1930 x 2185)
WITH TRANSOMDoor Opening Dimension Overall Frame Dimension Masonry Opening DimensionUnchanged from above. Add 3' 1-3/4" (959) to above heights. Add 3' 1-3/4" (959) to above heights.
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
10 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016ENTRANCE OFFERINGS
STANDARD OPTIONALDoors Narrow stile 250 doors prepared for attachment hardware. Wide stile 425.
Door Sizes Std. Standard sizes shown on page 9. Any size up to 3'-6" x 8'-0" (1067 x 2438).
Glass Stops Square glass stops for 1" (25.4) infill.
Door Frames TrifabTM VG 451T Center - 2" x 4-1/2" (50.8 x 114.3) for double glazing.
Other Kawneer framing system suitable for door frames may be selected, but manufactured per order.
Push-Pulls Single Acting: Architects Classic Hardware "CO-9" Pull and "CP-II" Push Bar.
Architects Classic Hardware "CO-9" Pull and "CP" Push Bar.
Single Acting: Architects Classic Hardware "CO-12" and "CP-II" push bar.
Architects Classic Hardware "CO-12" and "CP" push bar.
Architects Classic Hardware "CO-9"/"CO-9" Pulls.
Architects Classic Hardware "CO-12"/"CO-12" Pulls.
Door Closers Single Acting: Norton 1601 adjustable or 1601 BF adjustable surface closer with back-check and with or without adjustable hold-open.
Single Acting: LCN 1260 adjustable surface closer.
LCN 4040 surface closer with or without adjustable hold-open.
Standard COC with single scting offset arm.
Norton 8100 surface closer with a 50% spring power adjustment (for opening forces of less than 8 pounds). Closer is available with standard back-checks and with or without the hold-open feature.
Falcon SC 60 Surface closer.
Hinging Single Acting: Kawneer top and bottom offset pivots (or) Kawneer top and bottom 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP) (or) Kawneer continuous gear hinge.
Intermediate Pivots/Butts
Single Acting: Kawneer intermediate offset pivot (or) Kawneer 4-1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with non-removable pin (NRP).
Single Acting: Rixson M-19 or IVES #7215-INT intermediate offset pivot.
Power Transfers
Single Acting: Kawneer EL intermediate offset pivot (or) Kawneer EL 4 1/2" x 4" (114.3 x 101.6) ball bearing butt hinge with wire transfer (or) EPT (Electric Power Transfer).
SP-1000X Power Supply: For use with EL exit devices.
Power Supply PS1, PS5-4, and PS5-6 Power Supplies: For use with Kawneer 1686 EL and 1786 EL exit devices only.
SP-1000X Power Supply.
Locks -Active Leaf
Adams-Rite MS 1850A deadlock with two 1-5/32" (29.4) diameter 5 pin cylinders.
Adams-Rite #4510 Latch Lock.Adams-Rite #1850A-500 Short Throw Deadlock.Adams-Rite #1850A-505 Hookbolt Lock.Adams-Rite #4015 Two-point Lock.Adams-Rite #4015 & 4016 three-point lock.Adams-Rite #7130 Electric Strike.Kawneer Cylinder Guard.Kawneer Thumbturn (in lieu of cylinder).
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
11AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016ENTRANCE OFFERINGS
STANDARD OPTIONALLocks -Inactive Leaf
One pair of Kawneer flush bolts in the inactive leaf of a pair of doors.
Thresholds A 1/2" x 4-1/2" (12.7 x 114.3) aluminum mill finish threshold.
Weathering Single Acting: Weathering system in the door and frame consisting of a dense, bulb polymeric material, which remains resilient and retains its weathering ability under temperature extremes. Complete with an optional EPDM blade gasket sweep strip applied to both the interior and exterior of the bottom rail with concealed fasteners.
Exit Device Kawneer 1686 Concealed Rod Exit Device with or without a mortised type cylinder.
Kawneer 1786 Rim Exit Device is a rim type exit device with or without a rim type cylinder.
Kawneer 1686 CD concealed rod exit device available with cylinder dogging.
Kawneer 1786 CD rim exit device available with cylinder dogging.
Kawneer 1686 EL Concealed Rod Exit Device electric modification is available.
Kawneer 1786 EL Rim Exit Device electric modification is available.
Adams-Rite 8600 concealed rod exit device.
Adams-Rite 8400 rim exit device.
Falcon 1690 Concealed Rod Exit Device with or without rim type cylinder.
Falcon 1790 Rim Exit Device rim type exit device with or without a rim type cylinder.
Falcon EL 1690 concealed rod exit device with or without a rim type cylinder. The device is designed for electrified access control and is compatible with most key pad and card reader systems.
Falcon EL 1790 rim type exit device with or without a rim type cylinder. The device is designed for electrified access control and is compatible with most key pad and card reader systems.
Falcon 1990 is a concealed rod exit device with or without a rim type cylinder.
Falcon 2090 is a rim type exit device with or without a rim type cylinder.
Von Duprin 33 concealed rod exit device with or without night latch assembly.
Von Duprin 99 concealed rod exit device with or without night latch assembly.
Exit Device Pulls:Architects Classic style "CO-9" Pull.
Optional Exit Device Pulls:Architects Classic style "CO-12" Pull.
Reference Hardware section for additional information
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
12 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016PUSH-PULL HARDWARE
ARCHITECTS CLASSIC (PUSH PULL SETS)SINGLE ACTING DOORS USE A PULL HANDLE AND PUSH BAR.
Refer to HARDWARE SECTION forcomplete hardware information.
CO-9 / CP-IICO-12 / CP-II
CO-9 / CPCO-12 / CP
CP-II / CP-II CP / CP
CO-9 / CO-9CO-12 / CO-12
ARCHITECTS CLASSIC (COMPONENTS)
"CO-9"PULL
"CO-12"PULL
"CP-II" PUSH BAR "CP" PUSH BAR
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
13AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016
EXIT DEVICES and EXIT DEVICE PULLS
"CO-9"PULL
"CO-12"PULL
CONCEALED ROD EXIT DEVICEFalcon 1990
RIM LATCH EXIT DEVICEFalcon 2090
CONCEALED ROD EXIT DEVICEFalcon 1690
Falcon EL 1690
RIM LATCH EXIT DEVICEFalcon 1790
Falcon EL 1790
CONCEALED ROD EXIT DEVICEKawneer 1686
Kawneer 1686 CDKawneer 1686 EL
RIM LATCH EXIT DEVICEKawneer 1786
Kawneer 1786 CDKawneer 1786 EL
MORTISE EXIT DEVICE Adams-Rite 8400 CONCEALED EXIT DEVICE
Adams-Rite 8600
CONCEALED EXIT DEVICE Von Duprin 3347A CONCEALED EXIT DEVICE
Von Duprin 9947
EXIT DEVICES
LEVER HANDLEKawneer 1686Kawneer 1786
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
10"
(254
.0)
1-3/
8"
(34.
9)
8-1/
4"
(209
.6)
1/2"
(12.7)
1"
(25.
4)
2-15
/32"
(62.
7)
069177
1/2"
(12.7)
11/1
6"
(17.
5)
2-15
/32"
(62.
7)
069154
14 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016
10" BOTTOM RAIL
APPLIED DOOR STOP
APPLIED DOOR STOP
OPTIONS AND ACCESSORIES
1-3/8" CROSSRAIL 8-1/4" CROSSRAIL
SCALE 3" = 1'-0"
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
0.49
66%
0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20
0.70
0.80
0.60
0.50
0.40
0.30
0.2085 80 75 70 65 60
0.75
0.65
0.55
0.45
0.35
0.25
(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)
0.90
0.85
7'-2
"(2
184.
4)
3'-4"(1016.0)
30.125"(765.2)
75.7
5"(1
924.
1)
15AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL CHARTS
Example Glass U-Factor = 0.28 Btu/hr • ft2 • °F
Total Daylight Opening = 30.125" x 75.75" = 15.85 ft2
Total Projected Area = 3'-4" x 7'-2" = 23.9 ft2
Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (15.85 ÷ 23.9)100 = 66%
System U-factor vs Percent of Glass Area
EXAMPLE
NOT FOR DESIGN
COGU-factor
Percent of Glass Area
Based on 66% glass and center of glass (COG) U-factor of 0.28System U-factor is equal to 0.49 Btu/hr • ft2 • °F
Btu
hr •
ft2 • °F
Syst
em U
-fact
or
(DLO)
(DLO
)
(F.W.)
(F.H
.)
Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
0.47 (2.67)0.46 (2.61)0.44 (2.50)0.42 (2.39)0.40 (2.27)0.38 (2.16)0.36 (2.05)0.34 (1.93)0.32 (1.82)0.30 (1.71)0.28 (1.59)0.26 (1.48)0.24 (1.37)
0.22 (1.25)0.20 (1.14)0.18 (1.02)0.16 (0.91)0.14 (0.80)0.12 (0.68)0.10 (0.57)
16 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016
AATM250 (SINGLE DOOR)
System U-factor vs Percent of Glass Area
Syst
em U
-fact
or (B
TU/h
r·ft2 ·o F)
Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)
COGU-factor
Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier.
THERMAL CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
17AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Syst
em S
HG
C
Vision Area / Total Area (%)
COGSHGC
System Visible Transmittance (VT) vs Percent of Vision Area
Syst
em V
T
Vision Area / Total Area (%)
COGVT
AATM250 (SINGLE DOOR)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
18 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL PERFORMANCE MATRIX (NFRC SIZE)
AATM250 (SINGLE DOOR)Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.570.46 0.570.44 0.550.42 0.540.40 0.530.38 0.520.36 0.510.34 0.500.32 0.490.30 0.480.28 0.470.26 0.460.24 0.460.22 0.440.20 0.430.18 0.420.16 0.410.14 0.400.12 0.390.10 0.38
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.450.70 0.420.65 0.390.60 0.360.55 0.340.50 0.310.45 0.280.40 0.250.35 0.220.30 0.190.25 0.160.20 0.130.15 0.110.10 0.080.05 0.05
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.75 0.430.70 0.400.65 0.370.60 0.340.55 0.310.50 0.290.45 0.260.40 0.230.35 0.200.30 0.170.25 0.140.20 0.110.15 0.090.10 0.060.05 0.03
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8").
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
0.47 (2.67)0.46 (2.61)
0.44 (2.50)
0.42 (2.39)
0.40 (2.27)
0.38 (2.16)
0.36 (2.05)
0.34 (1.93)
0.32 (1.82)
0.30 (1.71)
0.28 (1.59)
0.26 (1.48)
0.24 (1.37)
0.22 (1.25)
0.20 (1.14)0.18 (1.02)
0.16 (0.91)
0.14 (0.80)0.12 (0.68)
0.10 (0.57)
19AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016
AATM250 (PAIR OF DOORS)
System U-factor vs Percent of Glass Area
Syst
em U
-fact
or (B
TU/h
r·ft2 ·o F)
Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)
COGU-factor
Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier.
THERMAL CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
20 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Syst
em S
HG
C
Vision Area / Total Area (%)
COGSHGC
System Visible Transmittance (VT) vs Percent of Vision Area
Syst
em V
T
Vision Area / Total Area (%)
COGVT
AATM250 (PAIR OF DOORS)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
21AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL PERFORMANCE MATRIX (NFRC SIZE)
AATM250 (PAIR OF DOORS)Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.560.46 0.550.44 0.540.42 0.530.40 0.520.38 0.510.36 0.500.34 0.490.32 0.480.30 0.460.28 0.450.26 0.440.24 0.430.22 0.420.20 0.410.18 0.390.16 0.380.14 0.370.12 0.360.10 0.35
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.480.70 0.450.65 0.420.60 0.390.55 0.360.50 0.320.45 0.290.40 0.260.35 0.230.30 0.200.25 0.170.20 0.140.15 0.110.10 0.080.05 0.05
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.75 0.460.70 0.430.65 0.400.60 0.370.55 0.340.50 0.310.45 0.280.40 0.250.35 0.210.30 0.180.25 0.150.20 0.120.15 0.090.10 0.060.05 0.03
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8").
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
0.47 (2.67)0.46 (2.61)0.44 (2.50)0.42 (2.39)0.40 (2.27)0.38 (2.16)0.36 (2.05)0.34 (1.93)0.32 (1.82)0.30 (1.71)0.28 (1.59)0.26 (1.48)0.24 (1.37)0.22 (1.25)0.20 (1.14)0.18 (1.02)0.16 (0.91)0.14 (0.80)0.12 (0.68)0.10 (0.57)
22 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016
AATM425 (SINGLE DOOR)
System U-factor vs Percent of Glass Area
Syst
em U
-fact
or (B
TU/h
r·ft2 ·o F)
Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)
COGU-factor
Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier.
THERMAL CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
23AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Syst
em S
HG
C
Vision Area / Total Area (%)
COGSHGC
System Visible Transmittance (VT) vs Percent of Vision Area
Syst
em V
T
Vision Area / Total Area (%)
COGVT
AATM425 (SINGLE DOOR)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
24 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL PERFORMANCE MATRIX (NFRC SIZE)
AATM425 (SINGLE DOOR)Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.580.46 0.580.44 0.570.42 0.560.40 0.550.38 0.540.36 0.530.34 0.520.32 0.510.30 0.510.28 0.500.26 0.490.24 0.480.22 0.470.20 0.460.18 0.440.16 0.430.14 0.430.12 0.420.10 0.41
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.390.70 0.360.65 0.340.60 0.320.55 0.290.50 0.270.45 0.240.40 0.220.35 0.190.30 0.170.25 0.150.20 0.120.15 0.100.10 0.070.05 0.05
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.75 0.360.70 0.340.65 0.320.60 0.290.55 0.270.50 0.240.45 0.220.40 0.190.35 0.170.30 0.150.25 0.120.20 0.100.15 0.070.10 0.050.05 0.02
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 960mm wide by 2090mm high (37-3/4" by 82-3/8").
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
0.47 (2.67)0.46 (2.61)0.44 (2.50)0.42 (2.39)0.40 (2.27)0.38 (2.16)0.36 (2.05)0.34 (1.93)0.32 (1.82)0.30 (1.71)0.28 (1.59)0.26 (1.48)0.24 (1.37)0.22 (1.25)0.20 (1.14)0.18 (1.02)0.16 (0.91)0.14 (0.80)0.12 (0.68)0.10 (0.57)
25AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016
AATM425 (PAIR OF DOORS)
System U-factor vs Percent of Glass Area
Syst
em U
-fact
or (B
TU/h
r·ft2 ·o F)
Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)
COGU-factor
Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values (winter conditions) and are obtained from your glass supplier.
THERMAL CHARTS
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
26 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL CHARTS
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
Syst
em S
HG
C
Vision Area / Total Area (%)
COGSHGC
System Visible Transmittance (VT) vs Percent of Vision Area
Syst
em V
T
Vision Area / Total Area (%)
COGVT
AATM425 (PAIR OF DOORS)
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
27AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016THERMAL PERFORMANCE MATRIX (NFRC SIZE)
AATM425 (PAIR OF DOORS)Thermal Transmittance 1 (BTU/hr • ft 2 • °F)Glass U-Factor 3 Overall U-Factor 4
0.48 0.570.46 0.570.44 0.560.42 0.550.40 0.540.38 0.530.36 0.520.34 0.510.32 0.500.30 0.490.28 0.480.26 0.470.24 0.460.22 0.450.20 0.440.18 0.430.16 0.420.14 0.410.12 0.400.10 0.39
SHGC Matrix 2
Glass SHGC 3 Overall SHGC 4
0.75 0.420.70 0.390.65 0.360.60 0.340.55 0.310.50 0.280.45 0.260.40 0.230.35 0.210.30 0.180.25 0.150.20 0.130.15 0.100.10 0.070.05 0.05
Visible Transmittance 2
Glass VT 3 Overall VT 4
0.75 0.390.70 0.370.65 0.340.60 0.320.55 0.290.50 0.260.45 0.240.40 0.210.35 0.180.30 0.160.25 0.130.20 0.110.15 0.080.10 0.050.05 0.03
NOTE: For glass values that are not listed, linear interpolation is permitted.
1. U-Factors are determined in accordance with NFRC 100.2. SHGC and VT values are determined in accordance with NFRC 200.3. Glass properties are based on center of glass values and are obtained from your glass supplier.4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 1920mm wide by 2090mm high (75-1/2" by 82-3/8").
Law
s an
d bu
ildin
g an
d sa
fety
cod
es g
over
ning
the
desi
gn a
nd u
se o
f gla
zed
entra
nce,
win
dow
, and
cur
tain
wal
l pro
duct
s va
ry w
idel
y. K
awne
er d
oes
not c
ontro
l th
e se
lect
ion
of p
rodu
ct c
onfig
urat
ions
, ope
ratin
g ha
rdw
are,
or g
lazi
ng m
ater
ials
, an
d as
sum
es n
o re
spon
sibi
lity
ther
efor
.
Kaw
neer
rese
rves
the
right
to c
hang
e co
nfigu
ratio
n w
ithou
t prio
r not
ice
whe
n de
emed
nece
ssar
y fo
r pro
duct
impr
ovem
ent.
© K
awne
er C
ompa
ny, I
nc.,
2015
kawneer.com
EC 97911-092
28 AATM250/425 Thermal Entrances
ADMA050EN
MAY, 2016BLANK PAGE