Upload
hoangbinh1410
View
216
Download
0
Embed Size (px)
Citation preview
8/13/2019 a3 Hdcs Fibre
1/76
A3. HDCS Fiber SolutionRosenberger AsiaRosenberger Asia--Pacific Sales & Marketing Dept. 2010.Pacific Sales & Marketing Dept. 2010.
8/13/2019 a3 Hdcs Fibre
2/76
8/13/2019 a3 Hdcs Fibre
3/76
1, What is Fiber
2, About SM/MM Fiber
3, HDCS Fiber Solution
4, HDCS Example
Contents
8/13/2019 a3 Hdcs Fibre
4/76
ConsumerElectronics
VideoVideo
TelecomsTelecoms ComputingComputing
Video &Video-
conferencing
CDCD--II
Databases
HDTV
Fax
Virtual reality
Multi-media
INTERNETINTERNET
The application of Fiber
HDCS
Basic-About Fiber
8/13/2019 a3 Hdcs Fibre
5/76
Advantages of Fiber
1. High Bandwidth
2. Low Attenuation
3. No Crosstalk4. No EMI
5. No need for Grounding
6. Safety7. Easy Upgrade
8. Green
HDCS
Basic-About Fiber
8/13/2019 a3 Hdcs Fibre
6/76
What is Fiber? How can light transmit inside?
HDCS
Basic-About Fiber
8/13/2019 a3 Hdcs Fibre
7/76
Total Reflect when n1 sin 1 = n2 sin 2
1 1
n2
n1
incidence
Refracted
reflect Critical Angle Total reflect
2
HDCS
Total Reflect
8/13/2019 a3 Hdcs Fibre
8/76
CORE FunctionTransmitt ing light Materialgermanium-doped sil icaCLADDING
FunctionTotal Reflect MaterialPure Silicon GlassCOATING
FunctionProtect Fiber MaterialPolyacrylates or Silicon
Coating
250/400 um
Core
9/50/62.5/100um
Cladding
125 um
HDCS
Structure of Fiber
8/13/2019 a3 Hdcs Fibre
9/76
8/13/2019 a3 Hdcs Fibre
10/76
8/13/2019 a3 Hdcs Fibre
11/76
MCVDMCVDH2, O2
Reaction Deposition of particleSiO2, GeO2
SiCl4,
GeCl4, O2
Tube Glass Silicon Tube
Waste
gas
Cl2
How to make Fiber
8/13/2019 a3 Hdcs Fibre
12/76
MCVD
How to make Fiber
8/13/2019 a3 Hdcs Fibre
13/76
VADVAD
SiCl4, GeCl4 , H2,
O2
Reaction
Pulling or
Rotating
Wasted
Gas
Glass Club
Fritted Glass
How to make Fiber
8/13/2019 a3 Hdcs Fibre
14/76
VAD
How to make Fiber
8/13/2019 a3 Hdcs Fibre
15/76
Glass ClubHeat To 2000C
Coating
Selection Tray Filling
Tightly
How to make Fiber
Step2. Make Fiber By Dropping
8/13/2019 a3 Hdcs Fibre
16/76
8/13/2019 a3 Hdcs Fibre
17/76
Spring Ceramic
Ferrule
TubeFiber
Top of Ferrule
R5 25 mm
About Fiber Connector
8/13/2019 a3 Hdcs Fibre
18/76
8/9
APC Connector has an angle to let the reflect light out of the fiber,
and improving the return loss performance
About Fiber Connector
8/13/2019 a3 Hdcs Fibre
19/76
About Fiber Connector
What makes a Bad connection
Fiber end faces should be free of any contamination or defects, as shown below:
Common types of contamination and defects include the following:
Dirty Oil Pits and Chips Scratch
8/13/2019 a3 Hdcs Fibre
20/76
8/13/2019 a3 Hdcs Fibre
21/76
125125 mm
50or62.550or62.5 mm
rr
nn
rr
nn
125125 mm
99 mm
Multimode
100X Picture of Fiber
Single Mode
HDCS
Structure of Fiber-SM/MM
8/13/2019 a3 Hdcs Fibre
22/76
( )E z t E z t, sin=
0
2
r
ExAmplitude E0Phase F
Wavelength l
y
x z
Electric FieldE
Magnetic FieldH
HE11/TEM10 ModeSingle Mode
What is LightTransmission Mode
8/13/2019 a3 Hdcs Fibre
23/76
MM 62.5/125um62.5 m Core
125 m Cladding250 m Coating
OM1
SM9.3 m Mode-Field
125 m Cladding250 m Coating
OS1/OS2
Attenuation:
8/13/2019 a3 Hdcs Fibre
24/76
Stepped IndexStepped Index
Stepped Index (SM)Stepped Index (SM)
Graded IndexGraded Index
n1.458
1.462
1.472
Input Pulse Output Pulse
refractive index
Different Index type of Fiber
8/13/2019 a3 Hdcs Fibre
25/76
Light Signal(pulse) travels along many modes or paths.
Pulse Spreading occurs due to Modal Dispesion, Called DMD(Differential Mode Delay) Pulse Spreading Limits BandWidth(Transmission Carrying Capacity)
Modal Dispesion of MM Fiber
MultiMode
Excessive Pulse Spreading=Inter-symbol Interference (ISI)= Bit Errors
8/13/2019 a3 Hdcs Fibre
26/76
8/13/2019 a3 Hdcs Fibre
27/76
Bandwidth of different MM Fiber
FOL BW=Overfilled Lannch
Bandwidth
EMB = Effective ModalBandwidth
(Laser-Optimized)
EMB met by meeting:a) DMD specifications,
b) EMBc
8/13/2019 a3 Hdcs Fibre
28/76
Reach and Bandwidth of MM Fibers
8/13/2019 a3 Hdcs Fibre
29/76
8/13/2019 a3 Hdcs Fibre
30/76
Eliminates modal Dispersion
Takes advantage of lower attenuation at longer wavelengths(1310&1550nm) Enables tremendous transmission capacity over very long distances
Single Mode Fiber
SingleMode
Small Core guides only one mode
8/13/2019 a3 Hdcs Fibre
31/76
500 600 700 850 900 1000 1100 1200 1310 1400 1550
LED / VCSEL LASER DIODE
Wavelength (nm)
Normal OS1 fiber
Attenuation
Attenuation and Wavelength
8/13/2019 a3 Hdcs Fibre
32/76
OS2 Zero/low water Peak
Attenua
tion
500500 600600 700700 850850 900900 10001000 11001100 12001200 13101310 13831383 15501550
LED / VCSELLED / VCSEL LASER DIODELASER DIODE
Wavelength (nm)
Rosenberger OS fiber Eliminate water peak at 1383nm
Attenuation and Wavelength
8/13/2019 a3 Hdcs Fibre
33/76
MultiMode Light Distance Support
8/13/2019 a3 Hdcs Fibre
34/76
8/13/2019 a3 Hdcs Fibre
35/76
1, What is Fiber
2, About SM/MM Fiber
3, HDCS Fiber Solution
4, HDCS Example
Contents
8/13/2019 a3 Hdcs Fibre
36/76
Trunk Cable
9 EIA Fiber Panel
Fiber connector and Pacthcord
FTTD
Fiber Faceplate
Crimp Fiber Connector
Wall Mounted
HDCS Fiber SolutionFTTDAll Fiber Solution
8/13/2019 a3 Hdcs Fibre
37/76
Trunk
FTTD Faceplate
19 Fiber PanelWall Mounted
Campus/backbone/horizontal Fiber Cable
Pigtail andpacth cord
Crimp connector
HDCS Fiber Solution
All Fiber Solution
8/13/2019 a3 Hdcs Fibre
38/76
ESCON
MU MU APC MTP LC/PC LC/APCE-2000
DIN
FC-PCFC-APCFDDI
FSMAMT-RJSC/PC ST
SC-APC
Rosenberger Can provide many types of fiber connector
HDCS Fiber Solution-Products
Fiber Connector and Patchcord
8/13/2019 a3 Hdcs Fibre
39/76
100% Performance test
Interferometer testing, quality guarantee
Follow IEC, EIA, Telcordia / Bellcore standard
SM,MM,OM3 types optional
OFNROFNPLSZH Fire Retardant level
HDCS Fiber Solution-Products
Fiber Patch cord and Pigtail
8/13/2019 a3 Hdcs Fibre
40/76
Features:
SM,MM optional
Plastic / Metal Shell optional
Simplex or Duplex
Hybrid adaptor
HDCS Fiber Solution-Products
Adaptor
8/13/2019 a3 Hdcs Fibre
41/76
Long time installing
Special tools and equipment
Training necessary
Splice Box
Pigtail
Fiber management
Splice tray
Fiber Cable
HDCS Fiber Solution-Products
Traditional Fiber Splicing Solution
8/13/2019 a3 Hdcs Fibre
42/76
Trunk Cable is pre-installing the connectors in Manufactory on both sides
of Fiber cable based on the requirements as what type of connector and
the length of fiber cable. And also add special high strength protection
Accessories
Trunk Cable Protection Tube
indoor / outdoor
HDCS Fiber Solution-Products
Fiber Trunk Cable
8/13/2019 a3 Hdcs Fibre
43/76
8/13/2019 a3 Hdcs Fibre
44/76
Trunk Cable
Prefect protection
Normal Fiber+Splice+Pigtail+Field Testing+Re-Splice+Easy install+Safety+Easy Maintenance
With
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
45/76
Why we need Pre-connect Technology:
1) Saving Investment: Protect the owner's right to know, avoid wasting andinvestment risk2) Easy install, saving time: Plug and Play3) Stable and reliable: 100% Manufactory performance test, only needcontinuity test after installing4) Perfect protection: No splice point and Bare fibre in air, avoid agingproblem5) Easy maintenance: Nice mechanical character, avoid damage Fiber
During maintenance6) Reinstallation: Trunk Cable is easy moving and safety plug and reinstall.
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
46/76
Work effor for established splice soultion:
Cabling laying 100m route, 2 persons 1 hour
Splicing incl.ancillary works and measuring 48
Fibers: 8 hours
Totally 9 Hours
Splicing Preconnector
Work effor for Preconnector trunk:
Cabling laying 100m route, 2 persons 1 hour
Application of plug connectors,installaiton of
disgributor housings and light function test, 2persons: 0.75 hours
Totally: 1.75 Hours
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
47/76
Special Design slot on distribution
Resistance force from pulling and
rotating
Fast installation
Installation of trunk cable onInstallation of trunk cable ondistributiondistribution
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
48/76
Order And Install Trunk CableOrder And Install Trunk Cable
Notes:
Order: Calculate the length of distance between racks and plus the
length of trunk cable in racks (normally 4-8 meters).
Install: Follow normal installing standard, trunk cable can afford 50N
pulling force, care inner size of tube while design.
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
49/76
Features:
Indoor / outdoor design
Mouse proof optional
IP67 for outdoor cable,IP50 for indoor cable
From 6 to 144 cores
Afford 500N pulling force
Easy reinstalling and maintenance
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
50/76
OM1,OM2, OM3, SM
LSZH or PE material coat
Different types of connector based onrequirements as: MT-RJ, MPO, SC, FC, ST,
E2000, LC, MU, DC.etc.
Customer Design length of trunk cable
Features
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
51/76
Trunk cable installing
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
52/76
Fiber Cable
Different types: Indoor/outdoor, FTTD
Following IEC60794-2, IEC60794-3 standard
Performance better than IEC11801, EIA568B and EN50173
requirements
All SM fibers are G.652D low water-peak Fiber
OM3 available
UL Certification
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
53/76
Application: indoor, outdoor, patch cord
Environment: Buried , Pipeline , mouse proof
Fire Retardant (indoor): OFNRRiser), OFNP (Plenum), LSZH
Buffer type (indoor): tight, semitight, loose
Fiber type: 50/125um, 62.5/125um, 9/125um, OM3 50/125um
Bandwidth: OM1(200/500), OM2(500/500), OM3(2000/500)
Mechanical: Pull strength, Bearing force, Bend Radius
Temperature: working/installing temperature
Numbers of cores
How to choice fiber cable
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
54/76
NEC & UL1651 Fire Retardant level for Indoor Fiber Cable
OFNR: Riser Level, prevent the spread of fire from difference floors , follow
UL1666 standard.
OFNP: Plenum level, Fire Retardant and low smoke, normal using in under
floor or ceiling, follow UL 910 standard.
LSZH: Low Smoke Zero Halogen, follow 60332-1/3, 60754-2, 61034-2
standard,
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
55/76
Indoor Fiber patch cord
a) Simplex Fiber
b) Duplex Fiber
c) Multi-core with coat
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
56/76
Indoor Trunk cable
b) Indoor Multi-core turnk cable
inner fiber diameter 2mm
a) Indoor Backbone Trunk cable
inner fiber diameter 0.9mm
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
57/76
Indoor/outdoor common cable
Central tube /Loose Tube Layer Stranded non-metal FRP Central strength enhance
KEVLAR/GLASS
Non-Metal
thermo-plastic loose tube Vertical water resist
Mouse proof
LSZH or PE coat
Max. 12x12 cores
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
58/76
Both for Trunk and Splice solution
Fixed or Drawer design
1HU for 24(48*) cores installation
2HU for 48(96*) cores installation
Different types of panel for Different
adaptors as SC-Duplex, ST, E2000, MT-
RJ, LC-Duplex, MU-Duplex, FC
Accessories for Splice
Fiber distribution
HDCS Fiber Solution-Products
8/13/2019 a3 Hdcs Fibre
59/76
Wall mounted Fiber Distribution
Features: Both for Trunk and Splice solution
SC, FC, ST, LC connector optional
12, 24, 48 core optional
Double Hinge Turing cover design ,easy for
installation
Build in lock for safety
Meet ROHS requirements
HDCS Fiber Solution-Products
HDCS Fib S l ti P d t
8/13/2019 a3 Hdcs Fibre
60/76
FTTD solution---Field Polishing Connector
Advantage: Only need normal fiber connector, low cost
Disadvantage: Special equipment, professional engineer, long time, no
guarantee for installation
HDCS Fiber Solution-Products
HDCS Fib S l ti P d t
8/13/2019 a3 Hdcs Fibre
61/76
FTTD solution---Field Splice
Advantage: Pigtail Splice, guarantee the connection
Disadvantage: Special equipment, professional engineer, long time, weak
of splice connection need special protection
HDCS Fiber Solution-Products
HDCS Fib S l ti P d t
8/13/2019 a3 Hdcs Fibre
62/76
SCSTLCMTRJ, etc. connectors optional
Follow ANSI/TIA/EIA-568-B.3 standard
Fast installing
Low cost, no need for polishing
0.4dB insert loss for SM
0.3dB insert loss for MM
FTTD solution---Field Cramp Connector
HDCS Fiber Solution-Products
HDCS Fiber Sol tion Prod cts
8/13/2019 a3 Hdcs Fibre
63/76
Structure of Field Crimp connector
HDCS Fiber Solution-Products
HDCS Fiber Solution Products
8/13/2019 a3 Hdcs Fibre
64/76
Suitable for SC simplex/duplex,ST, LC Duplex and MTRJconnector
Humanized Design turning dustcover
45Outlet suitable both Fiberadaptor and Copper connector
For standard 86x86 mounted
Outlet of FTTD
HDCS Fiber Solution-Products
HDCS Fiber Solution Products
8/13/2019 a3 Hdcs Fibre
65/76
Indoor armored fiber patch cord
Feature:
1. For FTTD patch cord
2. Metal-armored inside3. anti-
3000N/100mm
4. Bearing force >200N
5. Flexible and stabile
6. LC, SC, etc. connectors
NEW!
HDCS Fiber Solution-Products
Contents
8/13/2019 a3 Hdcs Fibre
66/76
1, What is Fiber
2, About SM/MM Fiber
3, HDCS Fiber Solution
4, HDCS Example
Contents
HDCS Example
8/13/2019 a3 Hdcs Fibre
67/76
Beijing Capital Airport T3
Project:
Cat 6 and OM3 cable
Voice/data point: 12000
FTTD point1500
HDCS Example
HDCS Example
8/13/2019 a3 Hdcs Fibre
68/76
ProjectCat 5E/Cat 6 and SM cableVoice/data point23000
HDCS Example
HDCS Example
8/13/2019 a3 Hdcs Fibre
69/76
HDCS Example
HDCS Example
8/13/2019 a3 Hdcs Fibre
70/76
HDCS Example
HDCS Example
8/13/2019 a3 Hdcs Fibre
71/76
HDCS Example
HDCS Example
8/13/2019 a3 Hdcs Fibre
72/76
HDCS Example
HDCS Example
8/13/2019 a3 Hdcs Fibre
73/76
CS a p e
8/13/2019 a3 Hdcs Fibre
74/76
HDCS Cabling Solution
8/13/2019 a3 Hdcs Fibre
75/76
1. One-Stop Total Solution
2. Quality Guarantee
3. Training and Consulting
4. Quickly and flexible delivery
5. Fast Action
6. Good performance-price ratio
g
8/13/2019 a3 Hdcs Fibre
76/76
Thank You