P P P P alarm 5 Pot Bain Marie BOXES Sneeze screen DDA Area U/C Drinks fridge Services - water / waste / elec located behind backfitting Services required - water / waste / elec New flooring 30 COVERS TRADE AREA P P STORE WC Extract hood Column Column Ice machine STAIRWELL 5no TV monitors STAIRWELL Retain existing - PROVIDE NEW FINISHES LOBBY New full height partitions & doors to form lobby ELEC Fryer ELEC Fryer Grab freezer Electric induction hobs and ingredients WHB Cup dispense Britvic dispense 5 Pot Bain Marie with Hot Cupboard Trays Till Column Bin Britvic unit connected to dispense over ceiling and down within void. Python for Britvic Stainless Steel Racking New decorations to wall finishes & ceiling. FD30 FD30 New fixed bench New Brand standard Bins Alarm panel to be relocated. Extract Hood Stainless Steel Racking Mop Sink w/ WHB Mop Rack Stainless Steel table Pull Cord P P P P P P Collection point Ingredients VCD 400mmØ KITCHEN EXTRACT DUCTING FIXED TO BRICKWORK AND TERMINATES ABOVE ROOF EAVES LEVEL WITH VERTICAL DISCHARGE TERMINAL. KITCHEN EXTRACT FAN FIXED TO BRICKWORK. 400mmØ KITCHEN EXTRACT DUCTING ROUTED THROUGH STORE TO EXTERNAL LIGHTWELL. DUCT THEN ROUTES AROUND EXTERNAL STAIR AND RISES TO HIGH LEVEL (SEE ABOVE TOR CONTINUATION) 400mmØ KITCHEN EXTRACT DUCTING RISES FROM LOW LEVEL AND OFFSETS TO WALL. 315mmØ KITCHEN EXTRACT DUCTING 315mmØ KITCHEN EXTRACT DUCTING VCD KITCHEN EXTRACT CANOPY 02 BY KITCHEN SPECIALIST KITCHEN EXTRACT CANOPY 01 BY KITCHEN SPECIALIST 400mmØ KITCHEN EXTRACT DUCTING 400mmØ KITCHEN EXTRACT DUCTING 400mmØ KITCHEN EXTRACT DUCTING DROPS THOUGH OPENING 400mmØ KITCHEN EXTRACT DUCTING RISES Indicative Layout Do Not Scale From Drawings Rev Date Description By Chkd NO SPECIFIC RISKS IDENTIFIED Drawing Title Stage Size Date: Scale: CAD: Chkd: Drawing No. HAWTHORNE BOYLE LTD MECHANICAL & ELECTRICAL CONSULTING ENGINEERS Merchant House Watermark Business Park 365 Govan Road Glasgow. G51 2SE Telephone: 0141 420 4448 Fax: 0141 427 2962 Email: [email protected] Website: www.hawthorneboyle.co.uk Project Title Rev. Architect / Client GROUND FLOOR AND REAR EXTERNAL PLANS AS PROPOSED KITCHEN VENTILATION LAYOUT KITCHEN FAN SELECTION MODEL GBD EC500 A T120 (CENT) [BY HELIOS] SUITABLE FOR OPERATING UP TO 120°C FAN TO BE SWITCHED AT BOTH CANOPY LOCATIONS - FAN SPEED CONTROLLER TO BE LOCATED IN CEILING VOID NEAR FAN UNIT. 1 THE INSTALLATION SHALL COMPLY WITH ALL LOCAL AUTHORITY BYELAWS, BRITISH STANDARDS AND THE TECHNICAL STANDARDS (BUILDING REGATION) SCOTLAND. 2 VENTILATION SYSTEMS SHALL BE SUPPLIED, CONSTRUCTED AND COMMISSIONED IN ACCORDANCE WITH THE FOLLOWING STANDARDS: - BS EN 13779:2007 BS EN 12237:2003 BS EN 1507:2006 BS EN 1505:1998 BS EN 1506:2007 BS EN 1886 2207 BS EN 15423:2008 HVCA DW 144 and DW 172 (2018) CIBSE COMMISSIONING CODE A 3 DUCTWORK SHALL BE CONSTRUCTED TO CLASS A - LOW PRESSURE. 4 DUCTWORK JOINTS SHALL BE SEALED WITH THE CORRECT SEALANT GASKETS OR TAPE. THE MATERIALS USED SHOULD BE SUITABLE FOR THE PURPOSE INTENDED AND SATIFY THE SPECIFIED PRESSURE CLASSIFICATION. 5 ALL PLANT AND DUCTWORK SHALL BE INSTALLED IN SUCH A MANNER THAT NO VIBRATION SHALL BE TRANSFERRED FROM THE PLANT TO THE BUILDING STRUCTURE. THIS SHOULD BE ACHIEVED THROUGH THE USE OF PROPRIETARY AV MOUNTS AND HANGERS. 6 TURNING VANES SHALL BE UTILISED ON ALL SQUARE THROAT BENDS WHERE EITHER DUCT DIMENSION IS GREATER THAN 200mm. TURNING VANES SHALL BE DOUBLE SKIN AEROFOIL TYPE. 7 ALL DUCTWORK SHALL BE SECURELY FIXED TO BUILDING STRUCTURE WITH DROP RODS, HANGERS AND/OR OTHER SUITABLE PROPRIETARY SUPPORTS ALL SPACED IN ACCORDANCE WITH TABLE 15 PAGE 44 OF HVCA DW144. ALL EQUIPMENT SHALL BE INSTALLED AND COMMISSIONED IN LINE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. THE CONTRACTOR SHALL CARRY OUT FULL SITE SURVEY TO DETERMINE BOTH EXTENT & NATURE OF WORKS. THE CONTRACTOR SHALL ALLOW FOR THE SUPPLY AND INSTALLATION OF ALL NECESSARY SUPPLEMENTARY FITTINGS, COMPONENTS AND EQUIPMENT TO SUPPORT A FULLY FUNCTIONING SYSTEM AND TO CO-ORDINATE WITH ALL OTHER SERVICES & BUILDING FABRIC/STRUCTURE. INDICATIVE ROUTE OF KITCHEN EXTRACT DUCT AT REAR STAIRWELL (ROUTED TO AVOID EXISTING ARIEL)

A1 Proposed Grd Floor

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: A1 Proposed Grd Floor

P

P

P

P

alarm

5 Po

t Bai

n M

arie

BOXES

Snee

ze sc

reen

DD

AA

reaU/C

Drinks

fridge

Serv

ices

- w

ater

/ w

aste

/ e

lec

loca

ted

beh

ind

bac

kfitt

ing

Serv

ices

requ

ired

- w

ater

/ w

aste

/ e

lec

New

floo

ring

30 COVERSTRADE AREA

P

P

STORE

WC

Extract hood

Column

Column

Ice machine

STAIRWELL

5no

TV m

onito

rs

STAIRWELLRetain existing - PROVIDE NEW FINISHES

LOBBY

New full heightpartitions & doorsto form lobby

ELECFryer

ELECFryer

Grab freezer

Electric induction hobsand ingredients

WHB

CupdispenseBritvicdispense

5 Po

t Bai

n M

arie

with

Hot C

upbo

ard

Tray

s

Till

Column

Bin

Britvic unit connected todispense over ceiling anddown within void.

Pythonfor Britvic

Stai

nles

s Ste

elRa

ckin

g

New decorations towall finishes &ceiling.

FD30 FD30

New fixed bench

New Brandstandard Bins

Alarm panel tobe relocated.

ExtractHood

Stai

nles

s Ste

elRa

ckin

g

Mop Sinkw/ WHB M

op Rack

Stainless Steeltable

Pull Cord

P

P

P

P

P

P

Collection point

Ingr

edie

nts

VCD

400mmØ KITCHEN EXTRACT

DUCTING FIXED TO BRICKWORK

AND TERMINATES ABOVE ROOF

EAVES LEVEL WITH VERTICAL

DISCHARGE TERMINAL.

KITCHEN EXTRACT FAN

FIXED TO BRICKWORK.

400mmØ KITCHEN EXTRACT

DUCTING ROUTED THROUGH

STORE TO EXTERNAL LIGHTWELL.

DUCT THEN ROUTES AROUND

EXTERNAL STAIR AND RISES TO

HIGH LEVEL (SEE ABOVE TOR

CONTINUATION)

400mmØ KITCHEN EXTRACT

DUCTING RISES FROM LOW LEVEL

AND OFFSETS TO WALL.

315mmØ

KITCHEN

EXTRACT

DUCTING

315mmØ

KITCHEN

EXTRACT

DUCTING

VCD

KITCHEN EXTRACT

CANOPY 02 BY

KITCHEN

SPECIALIST

KITCHEN EXTRACT

CANOPY 01 BY

KITCHEN

SPECIALIST

400mmØ

KITCHEN

EXTRACT

DUCTING

400mmØ

KITCHEN

EXTRACT

DUCTING

400mmØ

KITCHEN

EXTRACT

DUCTING

DROPS

THOUGH

OPENING

400mmØ KITCHEN

EXTRACT DUCTING

RISES

Indicative LayoutDo Not Scale FromDrawings

Rev Date Description By Chkd

NO SPECIFIC RISKS IDENTIFIED

Drawing Title

Stage

Size

Date:

Scale:

CAD:

Chkd:

Drawing No.

HAWTHORNE BOYLE LTDMECHANICAL & ELECTRICAL CONSULTING ENGINEERS

Merchant HouseWatermark Business Park365 Govan RoadGlasgow. G51 2SE

Telephone: 0141 420 4448 Fax: 0141 427 2962Email: [email protected]: www.hawthorneboyle.co.uk

Project Title

Rev.

Architect / Client

GROUND FLOOR AND REAR EXTERNAL PLANS AS PROPOSEDKITCHEN VENTILATION LAYOUT

KITCHEN FAN SELECTION

MODEL GBD EC500 A T120 (CENT) [BY HELIOS]

SUITABLE FOR OPERATING UP TO 120°C

FAN TO BE SWITCHED AT BOTH CANOPY LOCATIONS - FAN SPEED

CONTROLLER TO BE LOCATED IN CEILING VOID NEAR FAN UNIT.

1 THE INSTALLATION SHALL COMPLY WITH ALL LOCAL AUTHORITYBYELAWS, BRITISH STANDARDS AND THE TECHNICAL STANDARDS(BUILDING REGATION) SCOTLAND.

2 VENTILATION SYSTEMS SHALL BE SUPPLIED, CONSTRUCTED ANDCOMMISSIONED IN ACCORDANCE WITH THE FOLLOWINGSTANDARDS: -BS EN 13779:2007BS EN 12237:2003BS EN 1507:2006BS EN 1505:1998BS EN 1506:2007BS EN 1886 2207BS EN 15423:2008HVCA DW 144 and DW 172 (2018)CIBSE COMMISSIONING CODE A

3 DUCTWORK SHALL BE CONSTRUCTED TO CLASS A - LOW PRESSURE.4 DUCTWORK JOINTS SHALL BE SEALED WITH THE CORRECT SEALANT

GASKETS OR TAPE. THE MATERIALS USED SHOULD BE SUITABLE FORTHE PURPOSE INTENDED AND SATIFY THE SPECIFIED PRESSURECLASSIFICATION.

5 ALL PLANT AND DUCTWORK SHALL BE INSTALLED IN SUCH AMANNER THAT NO VIBRATION SHALL BE TRANSFERRED FROM THEPLANT TO THE BUILDING STRUCTURE. THIS SHOULD BE ACHIEVEDTHROUGH THE USE OF PROPRIETARY AV MOUNTS AND HANGERS.

6 TURNING VANES SHALL BE UTILISED ON ALL SQUARE THROATBENDS WHERE EITHER DUCT DIMENSION IS GREATER THAN200mm. TURNING VANES SHALL BE DOUBLE SKIN AEROFOIL TYPE.

7 ALL DUCTWORK SHALL BE SECURELY FIXED TO BUILDINGSTRUCTURE WITH DROP RODS, HANGERS AND/OR OTHER SUITABLEPROPRIETARY SUPPORTS ALL SPACED IN ACCORDANCE WITH TABLE15 PAGE 44 OF HVCA DW144.ALL EQUIPMENT SHALL BE INSTALLED AND COMMISSIONED IN LINEWITH THE MANUFACTURERS INSTRUCTIONS ANDRECOMMENDATIONS.THE CONTRACTOR SHALL CARRY OUT FULL SITE SURVEY TODETERMINE BOTH EXTENT & NATURE OF WORKS.THE CONTRACTOR SHALL ALLOW FOR THE SUPPLY ANDINSTALLATION OF ALL NECESSARY SUPPLEMENTARY FITTINGS,COMPONENTS AND EQUIPMENT TO SUPPORT A FULLYFUNCTIONING SYSTEM AND TO CO-ORDINATE WITH ALL OTHERSERVICES & BUILDING FABRIC/STRUCTURE.

INDICATIVE ROUTE OF KITCHEN EXTRACT DUCT AT REAR STAIRWELL

(ROUTED TO AVOID EXISTING ARIEL)