A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"
Page 2: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"
Page 3: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"

Job No.:

Drawn By:

Checked by:

Filename:

Date:

JOB NO.

XXX

XXX

A2.1

Date

A2.1

BRAS

H HO

USE

2x2

ELEV

ATIO

NS

Revisions

# Date Description

*.DWG

AutoCAD SHX Text
A5.1
AutoCAD SHX Text
5
AutoCAD SHX Text
A5.1
AutoCAD SHX Text
4
AutoCAD SHX Text
2
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
REAR ELEVATION 2 BEDROOM MODULE
AutoCAD SHX Text
4
AutoCAD SHX Text
12
AutoCAD SHX Text
18"X24" GABLE VENTS, (4) PER GABLE END OF BUILDING
AutoCAD SHX Text
CONFIRM VENT LOCATION ABOVE BLOWN IN INSULATION
AutoCAD SHX Text
BATH AND LAUNDRY FAN TERMINATION
AutoCAD SHX Text
DRYER EXHAUST
AutoCAD SHX Text
DRYER EXHAUST
AutoCAD SHX Text
BATH AND LAUNDRY FAN TERMINATION
AutoCAD SHX Text
RADON EXHAUST
AutoCAD SHX Text
RADON EXHAUST
AutoCAD SHX Text
RADON EXHAUST
AutoCAD SHX Text
SHINGLE SIDING
AutoCAD SHX Text
COMPOSITE ASPHALT ROOFING
AutoCAD SHX Text
LAP SIDING
AutoCAD SHX Text
BATHROOM SOIL STACK
AutoCAD SHX Text
KITCHEN SOIL STACK
AutoCAD SHX Text
1
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
FRONT ELEVATION 2x2 BEDROOM MODULE
AutoCAD SHX Text
4
AutoCAD SHX Text
12
AutoCAD SHX Text
5/4 X 4 CORNER AND WINDOW/DOOR TRIM
AutoCAD SHX Text
STEEL INSULATED GARAGE DOOR
AutoCAD SHX Text
STEEL INSULATED ENTRY DOOR
AutoCAD SHX Text
12" SQUARE GABLE VENTS, (4) PER GABLE END OF BUILDING
AutoCAD SHX Text
A5.1
AutoCAD SHX Text
10
AutoCAD SHX Text
GUTTER LOCATION ATTACHED TO POST
AutoCAD SHX Text
* IN LOCATIONS WHERE THE ROOF DOES NOT OVERHANG INTO THE 5' SETBACK, SOFFIT VENTS CAN BE USED INSTEAD OF THE GABLE VENTS. GABLE VENTS MAY STILL WANT TO BE USED FOR AESTHETICS. NO SOFFIT VENTS CAN BE INSTALLED ON SOFFITS WITHIN THE 5' SETBACK. SEE DETAIL 4 SHEET A2.1 FOR FIRE RATED EAVE.
AutoCAD SHX Text
GUTTER LOCATION ATTACHED TO POST
AutoCAD SHX Text
BATHROOM SOIL STACK
AutoCAD SHX Text
3
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
SIDE ELEVATION 2 BEDROOM MODULE
AutoCAD SHX Text
KITCHEN SOIL STACK
AutoCAD SHX Text
A5.1
AutoCAD SHX Text
8
AutoCAD SHX Text
A5.1
AutoCAD SHX Text
9
AutoCAD SHX Text
SLIDER LOCATION TO BE DETERMINED BY CONTRACTOR
AutoCAD SHX Text
WATER HEATER EXHAUST, THROUGH ROOF
AutoCAD SHX Text
RANGE HOOD ESHAUST
Page 4: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"
Page 5: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"
Page 6: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"
Page 7: A0.1 Coversheet - Habitat-Spokane...box construction TBD by contractor. Closet shelt material by contractor. Stairs: A minimum headroom clearance for staineays oi not less than "1-8"