ATLANTIC 2000 - boilerplant sales ACM ATLANTIC - commissioning and maintenance ATLANTIC 4422 – spares Atlanc 2000 Registered in England Company No: 1477687 Vat Reg No: 306 0653 89 PO BOX 11, ASHTON UNDER LYNE, OL6 7TR T: 0161 621 5960 E: [email protected] www.atlancboilers.com A-YO SERIES ELECTRIC STEAM BOILER OPERATING & MAINTENANCE MANUAL ALL MODELS

A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6

ATLANTIC 2000 - boilerplant sales ACM ATLANTIC - commissioning and maintenance ATLANTIC 4422 – spares

Atlantic 2000 Registered in England Company No: 1477687 Vat Reg No: 306 0653 89

PO BOX 11, ASHTON UNDER LYNE, OL6 7TR T: 0161 621 5960 E: [email protected] www.atlanticboilers.com

A-YO SERIESELECTRIC STEAM BOILER

OPERATING & MAINTENANCE MANUALALL MODELS

Page 2: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6

Index

Performance ………………….. 2

Boiler drawings ………….. 3

Installation …………………… 8

Operation …………………….. 10

Setting the time control … 15

Daily maintenance ………….. 16

Fault finding ……………………. 18

Typical installation …………. 20

Typical electrical wiring … 21

Page 3: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
Page 4: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
BARSg
catalyst
Typewritten Text
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
7 to 10
catalyst
Typewritten Text
8 to 10
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
8 to 10
catalyst
Typewritten Text
8 to 10
catalyst
Typewritten Text
8 to 10
catalyst
Typewritten Text
catalyst
Typewritten Text
415/240
catalyst
Typewritten Text
415/240
catalyst
Typewritten Text
415/240
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
415
catalyst
Typewritten Text
Boiler front elevation
catalyst
Typewritten Text
1. Boiler pressure guage 2. System controller (pp 12 – 15) 3. Brake wheels
catalyst
Typewritten Text
Page 5: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
1 Safety valve 2. Output steam control valve 3. Feed water tank overflow 4. Feed water tank ball valve 5. Feed water tank drain 6. Housing cover plate 7. Boiler drain valve 8. Power supply inlet 9. Water supply inlet 10. Feed water tank 11. Frost protection water drain
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Boiler rear elevation
catalyst
Typewritten Text
catalyst
Typewritten Text
Boiler front inner elevation
catalyst
Typewritten Text
1. Electric control panel 2. Live, neutral & earth terminals 3. Electric leakage protection 4. Feed water pump fuse 5. Heating elements contactor 6. Feed water pump air bleed 7. Feed water pump 8. Heating elements fuse 9. Steam heating elements 10. Check valve stops reverse flow 11. Feed water pump motor
Page 6: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
Right side boiler elevation
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Boiler view from above
catalyst
Typewritten Text
1. Product rating plate 2. Feed water level sensor 3. Glass level tube with valves 4. Glass tube with flushing valve 5. Feed water levelling pipe
catalyst
Typewritten Text
1. High/low levelling of feed water 2. Low level limit stops heating 3. On/off pressure control 4. Pressure gauge 5. Pressure sensing pipe 6. Robust earth connection
Page 7: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Connect water supply, insert an isolating valve; ensure feed water is blow 50°C We recommend the installation of a water-softening plant.
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Connect the steam boiler output through a non-return valve to a distribution system
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Connect 3 x L’s to three live supply wires 1 x N to neutral supply 1 x PE to robust earth
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Connect safety valve outlet and frost valve outlet to sump. Avoid scalding of installer and operators on these pipe runs
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Page 8: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Check that the feed water tank is clean and free of all debris. Open valve and allow water into the Feed Water tank. Flow will stop when the tank is full and the ball valve is satisfied.
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Open the steam valve and close the drain outlet valve. Purge all air from the steam drum
catalyst
Typewritten Text
Open air screw on the feed water pump and check all air is removed. Switch on pump for 60 seconds and repeat air test until only water appears
catalyst
Typewritten Text
Switch on the power supply and the controller lights up. Check all terminals
Page 9: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
Press the ‘POWER’ button Full screen lights up Boiler indicates ‘lack of water’
catalyst
Typewritten Text
catalyst
Typewritten Text
Press ‘ON/OFF’ button Feed water added automatically And the high water mark reached and the feed water pump stopped plus the pump symbol disappears. Water is entering the steam drum If the feed water tank remains full, the Pump may be jammed – press ‘+’ for more than 5 seconds otherwise repeat the exercise of step three.
catalyst
Typewritten Text
Press ‘ON/OFF’ on controller Boiler is in ‘RUN’ condition and everything will operate. Display ‘P-L’, boiler will commence heating – turn on steam valve and cycle of heat/water feed will proceed
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
IMPORTANT NOTICE Boilers (3kW-15kW) have only one heating tube The remainder have two tubes, used in alternative lead order Symbols on the controller ‘M’ water level between ‘H’ and ‘L’ ‘L’ feed water pump on ‘H’ feed water pump off
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Page 10: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
Open the steam valve slowly to encourage dry steam at stable pressure To stop the boiler 1. Press ‘POWER’ button – controller display disappears 2. Turn of main electrical power 3. After 15seconds and pressure drops to 1BARg, open drain outlet
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
WARNING Do not open the drain immediately after stopping the boiler 1. Boiler can be damaged 2. Potential scalding of people close by
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Setting the time control
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
The steam boiler must be under the control of a qualified operator The operator must be in attendance during time setting
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Page 11: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
Regular Maintenace
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
After boiler is switched off, allowed to cool for 15minutes, and pressure falls to 1BARg Then drain valve is opened to release condensate
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
do not open drain valve too soon – there will be damage to the boiler
catalyst
Typewritten Text
Daily Maintenance
catalyst
Typewritten Text
Monthly Safety Valve Test
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Under pressure conditions, manually test the safety valve handle for blow-down conditions
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
If there is no blow-down, replace or service the safety valve
catalyst
Typewritten Text
Monthly Electrical Terminals Check
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Turn off the main power supply – check all terminal screws and bolts
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Three Monthly check heating tubes and boiler for scale
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
The heating tubes need to be withdrawn and, together with the boiler shell, cleaned of scale The amount of water treatment can be adjusted a s the amount of scale is recorded
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Page 12: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6

Fault Finding

ERROR POSSIBLE FAULT LIKELY REPAIR

LCD controller – no display Fuse failure Change fuse

Low voltage Check voltage

Wire(s) loose Check circuits

LCD faulty Replace LCD

LCD lights up – button F no go High or low voltage Check voltage

Button F faulty Replace LCD

Feed water pump not operating Pump seized Press ‘+’ to rotate pump

at low water boiler conditions No LCD message Replace LCD

Fuse burnt out Replace fuse

Wiring loose Check connections

Pump burnt out Replace pump

Pump rotating, no water flow Air in the pump Release the air

Check valve blocked Clean check valve

Water pump jammed Switch off boiler/open housing/release jamming

Water pump impeller worn Replace pump

Feed water full, pump continues Scale on high level water probe Check the HL water probe & clean if possible

HL probe connection loose Check the HL probe circuit

Water level control not correct Check the HL/LL control levels

Heat Contactor operates Circuit breaker not operating Open the circuit breaker

reduced or no output Circuit breaker has failed Replace the circuit breaker

AC contactor has failed Replace the AC contactor

Heating tube has failed Replace the heating tube

Power circuit has failed Fit new power wiring

Water level sensor failure Build-up of scale on sensor Clean or replace sensor

Sensor wire is faulty Check the circuit

Sensor housing is scaled up Clean the housing

Page 13: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6

ERROR POSSIBLE FAULT LIKELY REPAIR

Pressure gauge mis-reading Pressure gauge broken Replace gauge

Brass housing blocked Clean or replace housing

Water overspill from boiler Ball valve blocked in open tank Open tank lid and repair

Ball valve broken Replace ball valve

Open tank filled with hot water Back-feed from check valve Clean or replace check valve

Circuit breaker fails in OFF position Reset button in ‘OFF’ position Press re-set button

Heating tube has failed Replace heating tube

Circuit breaker has failed Replace circuit breaker

Circuit breaker circuit is faulty Check the circuit

Boiler over-rides working pressure Pressure controller faulty Replace pressure controller

Pressure control circuit faulty Check the circuit

Safety valve exhausts at low setting Safety valve is at faulty setting Test for behaviouror safety valve has alternate faulty steam/water cycle Safety valve has failed Replace with certificated safety valve

Safety valve exhausts too much water Incorrect action of feed water pump Drain boiler of water & re-start cycle

Water level sensor over-cycling Clean & wash the water level sensor

LCD Panel displays – contactor inert LCD controller is faulty Replace LCD controller

AC contactor is faulty Replace AC contactor

AC contactor circuit faulty Check the circuit

AC contactor vibrates in circuit Dust in the contactor Air pressure clean or replace

Voltage unstable Check voltage

Air leak in sight glass Lock ring faulty Replace lock ring

Fault Finding

Page 14: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
Feed Water
catalyst
Typewritten Text
catalyst
Typewritten Text
Feed water to boiler
catalyst
Typewritten Text
Water Treatment Samples
catalyst
Typewritten Text
Drain
catalyst
Typewritten Text
catalyst
Typewritten Text
Trapped Steam Header
catalyst
Typewritten Text
Steam Trap
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
A-YO
catalyst
Typewritten Text
catalyst
Typewritten Text
100kW electric steam boilers & typical circuit diagram
catalyst
Typewritten Text
catalyst
Typewritten Text
catalyst
Typewritten Text
voltage 240V/50Hz A-YO 3-9kW
catalyst
Typewritten Text
Page 15: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
voltage 415V/50Hz A-YO 3 – 15kW
catalyst
Typewritten Text
voltage 415V/50Hz A-YO 18 – 50kW
Page 16: A-YO SERIES - Atlantic Boilers · 1 Safety valve\r2. Output steam control valve\r3. Feed water tank overflow\r4. Feed water tank ball valve\r5. Feed water tank drain\r6
catalyst
Typewritten Text
catalyst
Typewritten Text
voltage 415V/50Hz A-YO 60 – 100kW
catalyst
Typewritten Text
catalyst
Typewritten Text