SMOKE AND FIRE CURTAINS
Fire Curtain Technologies distributes a wide range of fire and smoke protective curtains to protect every type of building application. Fire and smoke protective curtains provide means of escape and boundary protection to providing a building with a system that offers effective fire and smoke compartmentalization.
Product Name Housing type Max width Max drop Certification ComplianceAutomatic Fire Protective Smoke Curtain Multi unit 13.5 19.5 1 - 3 hours UL 10D, UL 1784
SI-N Single unit 14.5 9
SI-L Single unit 14.5 19.5 / 18
Single unit
Multi unit
Fixed Draft Curtain SM - ST ∞ 49 1 - 2 hours EN 12101-1, EN 1363-1
Automatic Smoke Sealed Curtain SD1 - 3 hours
UL 10D, UL 1784,EN 1634-3
Automatic Smoke Curtain SM51 - 3 hours
EN 12101-1, EN 1363-1EN 13501-1
FIRE CURTAINS
SMOKE CURTAINS
Our fire and smoke protective curtains offer various solutions to architects, engineers, consultants and specifiers providing the ability to design complex buildings that adhere to fire regulations and offer protection against smoke
Product Name Housing type Max width Max drop Certification ComplianceSingle unit 13.5 19.5
Multi unit 58 19.5
Automatic Fire Protective Smoke Curtain Multi unit 13.5 19.5 1 - 3 hours UL 10D, UL 1784
Single unit 16 12 / 18
Multi unit 16 / ∞ 12 / 18
Automatic Fire Protective Curtain FA 1 - 3 hours UL 10D, UL 1634-3
Automatic Fire Curtain FireMaster FM 1 - 3 hoursEN 1634-1, EN 13501-2EN 1363-2, EN 12101-10
Dimensions ( ft )
Dimensions ( ft )
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET |
There are four main components:
1 Head box
2 Roller with fabric
3 Side guides
4 Bottom bar with seal
11
32
44
Fire Curtain Technologies smoke and fire curtains are fully tested and certified to the latest fire regulations and building design technology.Fire Curtain Technologies provides a wide range of options: All system components (headboxes, fabric, bottom bars, drive systems) can be customized.All fire and smoke curtains can operate as an integrated part of a smoke control and fire management scheme, with emergency power units and the facility to interface directly with a fire control panel.Gravity Fail-safe – Unwinds curtain to its operational position without the need for power.Fire curtains are manufactured under the ISO 9001 quality standard by Colt Group International.
FIRE CURTAINS
Seal off an area to contain a fire and to prevent it from spreading.
Automatically deploy upon receipt of a signal from the fire-alarm panel, and automatically retracts when the signal has stopped.
Retain fire integrity in an emergency but allow complete freedom of passage when not in use.
•
•
•
•
•
•
•
•
•
•
•
•
SMOKE CURTAINS
Increase the time available for occupants to escape the building since they reduce the travel distances.Are a cost effective solution to zoning a building.Assist the emergency services by containing or channelling the smoke into predetermined areas.Limit travel and overcooling of smoke, reducing the risk of cold smoke dropping to low level and obscuring vision.
BENEFITS
FEATURES
BENEFITS AND FEATURES
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | UNIVERSAL FEATURES
The head box is made from galvanized steel and comprises stiffening brackets and a movable cover plate. Head boxes are also pre-assembled so to easily accommodate a roller or rollers. The bottom access covers are attached by means of screws on the side of the housing. Depending on the unit height and temperature classes (60 or 180), the housing type is either type N or type L.
SI-x DV-x DH-x
Headbox dimensions (mm)
Width Height Width H eight Width Height
SI-N 155 150 DV-N 155 250 DH-N 250 150
SI-L 180 185 DV-L 180 300 DH-L 300 185
Single headbox Double vertical headbox Double horizontal headboxSI-x DV-x DH-x
Headbox dimensions (mm)
Width Height Width H eight Width Height
SI-N 155 150 DV-N 155 250 DH-N 250 150
SI-L 180 185 DV-L 180 300 DH-L 300 185
Single headbox Double vertical headbox Double horizontal headboxSI-x DV-x DH-x
Headbox dimensions (mm)
Width Height Width H eight Width Height
SI-N 155 150 DV-N 155 250 DH-N 250 150
SI-L 180 185 DV-L 180 300 DH-L 300 185
Single headbox Double vertical headbox Double horizontal headbox
SI-x
Single headbox
DH-x
Double horizontal headbox
G type roller unit Gravity fail safeH type roller unit Gravity fail safe with intermediate stops
Technical information
SI DH DV
SingleDouble horizontalDouble vertical
DV-x
Double vertical headbox
Configuration and sizes:
Where a limited size of barrier is required (e.g. a fire door or shutter)
Where continuous runs with overlapped fabric to form a continuous barrier are required.
Where continuous runs with overlapped fabric to form a continuous barrier are required and where there is a premium on space under the ceiling.
Single (type SI)
Double vertical (type DV)
Double horizontal (type DH)
ROLLER MOTOR
The roller is a essential component of the fire protective curtain and provides, in connection with the controls, a safe function of the fire protective curtain.
Direct current motor
DC motor with planetary reduction gears
HEAD BOX Housing type SI / DH / DV
Housing dimensions (ft)
Width [B] Height [H]SI-N / SD-N 6 6SI-L / SD-L 7 7 1/4
Width [B] Height [H]DH-N 10 6DH-L 12 7 1/4
Width [B] Height [H]DV-N 6 10DV-L 7 12
Width [B] Height [H]SI-N / SD-N 6 6SI-L / SD-L 7 7 1/4
Width [B] Height [H]DH-N 10 6DH-L 12 7 1/4
Width [B] Height [H]DV-N 6 10DV-L 7 12
Width [B] Height [H]SI-N / SD-N 6 6SI-L / SD-L 7 7 1/4
Width [B] Height [H]DH-N 10 6DH-L 12 7 1/4
Width [B] Height [H]DV-N 6 10DV-L 7 12
Cloth
6
7 1⁄4
12
10
12
12
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | UNIVERSAL FEATURES
CLOTH
120 and E180 minute material60 minute material
60minute
120minute
180minute
Heat-stabilized fabric achieving 60 minutes fire integrity.
Heat-stabilized fabric with a stainless steel inlay achieving 120 minutes fire integrity and 30 minutes limitation of the radiation of heat.
Heat-stabilized fabric with a stainless steel inlay, achieving 180 minutes fire integrity and 30 minutes limitation of the radiation of heat.
The fabric is fire-resistant and comprises one of the following options:
Overlap for DH type curtainsSI with no overlap
Type SI Type DH Type DV
Overlap for DV type curtains
OVERLAPS
CORNERS
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | UNIVERSAL FEATURES
Designed for commercial applications, comprising steel angle with an additional aluminium profile connected to a spring in order to accommodate any unevenness in the floor in order to minimize smoke leakage.
UK
Consists of a contoured profile made of galvanized steel sheet. It is attached to the lower end of the cloth using rivets and serves:
As a weight to draw the curtain down to its working positionTo ensure that the curtain remains taut when it is deployedTo ensure there is a seal against the floor.
1 Cloth2 K bottom bar3 Additional weight 4 Spring5 Cover strip
1 Cloth2 U bottom bar 3 Additional weights 4 Round steel Ø10 mm 5 Spring6 Cover strip
•
•
•
K bottom bar profile
UK bottom bar profile
1
23
5
1
2
3 4
5
1
2
3
4
5
6
1
2 64
min.= 1/32 inmax. = 1/2 in
min
. 3 in
min. =1/32 inmax. = 1/2 in
min.= 1/32 inmax. = 1/2 in
min
. 3 in
min. =1/32 inmax. = 1/2 in
min.= 1/32 inmax. = 1/2 in
min
. 3 in
min. =1/32 inmax. = 1/2 in
Roller side guide system With either UK or U bottom bar
Roller side guide system With either UK or U bottom bar
Onto wall Into niche Onto soffit
A side guide system is nearly always fitted and provides a seal between the sides of the curtain fabric and the walls, ensuring that any positive or negative pressures created by a fire will be resisted by the curtain and so that it won’t deflect significantly.
Side guides can be integrated either into or onto a wall / soffit or into a recess / niche. COLT side guide roller system has been designed to ensure that the curtain will move to its closed position easily even when there are significant air velocities around the curtain.
Side guide assembly options
SIDE GUIDE
BOTTOM BAR
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET |
The Fire Protective Curtain is a gravity-deployed
fire barrier that maintains the integrity of a fire-
rated wall in commercial buildings and is used in
place of a fire door. The Fire Protective Curtain
is designed to operate both independently
or interface with a building Fire Alarm Control
Panel (FACP).
APPLICATIONS: Fire protective curtains are used in all industrial and commercial buildings, e.g. shopping centers, office buildings, atria, etc.
The Fire Protective Curtain is certified and labeled to UL 10D
FIRE PROTECTIVE CURTAIN FA AUTOMATIC FIRE CURTAIN
The fire protective curtain consists of a roller covered with a fiberglass fabric which is incorporated into a galvanized steel housing.
The roller unit incorporates a motor, planetary gearbox and internal microprocessor. The microprocessor monitors the rest position and independently regulates the closing speed to a maximum of 0,15m/s (6 in / sec).
Fire resistance 60 / 180 minutes
The housing is equipped with specially developed reinforced brackets, which maintains integrity at high temperatures. The bottom of the housing is closed off with a panel which allows the entire length of the system to be accessed. The system is equipped with side guides. The design ensures that the required compartmentalization is achieved.There are no visible fasteners either on the underside of the housing or on the front of the side guides. At the bottom of the curtain a bottom bar is attached which serves to ensure that the curtain operates as designed and also that it remains stable when unrolled.
The bottom bar makes contact with the floor when the curtain is deployed creating a smoke-tight seal with the floor. There are different bottom bars available for different applications.
The curtain headbox and side guides can be polyester powder coated in all RAL colors. The fabric is silver grey. The unit can be configured with mounting brackets either for wall or ceiling mounting.
Furnace testing in accordance with UL 10D, EN 1634-3
Smoke tightness tests
Materials class: A2-s1, d0
Quality of cloth1800°F Glass fabric2200°F Glass fabric with coating and stainless-steel inlay
Virtually invisible
FS, FR and FD PIN SIDE GUIDESwith integrated seals
Manufactured in accordance withISO 9001:2008
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET |
The SD Smoke Sealed Curtain is designed to restrict the passage of smoke from spreading It operates automatically when connected.
APPLICATIONS:Smoke sealed curtains are used in all industrial and commercial buildings, e.g. shopping centers, office buildings, lift landing lobbies, hospitals, retirement home, atria, etc.
The Smoke Sealed Curtain is
certified and labeled to UL 10D and
EN 1634-3 and further certified to
UL 1784
FIRE PROTECTIVE CURTAINAUTOMATIC SMOKE CURTAIN
Fire resistance + compartmentation60 / 180 minutes
Furnace testing in accordance with
UL 10D, EN 1634-3
Smoke tightness test UL 1784
Materials class: A2-s1, d0
Quality of cloth1800°F Glass fabric2200°F Glass fabric with coating and stainless-steel inlay
Virtually invisible
FS, FR and FD PIN SIDE GUIDESwith integrated seals
Manufactured in accordance withISO 9001:2008
SMOKE SEALED CURTAIN
The Smoke Sealed Curtain consists of a roller covered with a fiberglass fabric which is incorporated into a galvanized steel housing.
The roller unit incorporates a motor, planetary gearbox and controls electronics with a microprocessor. The microprocessor monitors the rest position when rolled up and independently regulates the closing speed to a maximum of 0,15 m/s (6in / sec).
The housing is equipped with specially developed reinforced brackets, which maintains integrity at high temperatures.The bottom of the housing is closed off with a panel which allows the entire length of the system to be accessed. The system is equipped with FD side guides. Their special tight design ensures that the required compartmentalization is achieved.There are no visible fasteners either on the underside of the housing or on the front of the side guides. At the bottom of the curtain a bottom bar is attached which serves to ensure that the curtain operates as designed and also that it remains stable when unrolled.
The bottom bar makes contact with the floor when the curtain is deployed, creating a smoke-tight seal with the building structure. There are different bottom bars available for different applications.
The curtain headbox and side guides can be polyester powder coated in all RAL colors. The fabric is silver grey. The unit can be configured with mounting brackets either for wall or ceiling mounting .
*Also available with Emergency Egress.
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET |
A Fixed Draft Smoke Curtain contains smoke and heat in the case of fire.
Per NFPA 92B, Draft curtains are generally used to channel or contain smoke that is attached to the underside of the ceiling and protrude a limited distance downward.
A fixed smoke curtain consists of several overlapping curtains attached together to provide a continuous run. They are connected together and to the building by means of clamps and angle pieces. The bottom of the cloth is weighted, ensuring that the curtain remains taut and reducing the amount of deflection through air currents.
FIXED SMOKE CURTAIN FIXED DRAFT CURTAIN
The installation angles and the clamping profiles are predrilled to accept rivets. The connecting pieces have a continuous predrilled hole pattern, enabling fast and easy assembly of the curtain fabric. The bottom bar has a loop to accommodate the weight.
SM-ST system can be used to close off a scheme of movable smoke curtains position below it, by clamping directly onto the housing of the movable smoke curtain.
Fixing brackets, clamping profiles and bottom bars are all in galvanized steel.
The curtain overlaps can be attached to one another using a spray adhesive approved by MPA Stuttgart, which seals the flaps tightly to to enhance the appearance of the surface of the curtain.
The SM-ST system is fixed to the building with approved fasteners at intervals of a maximum of 5 feet.
Smoke resistance 60 / 120 minutes
Smoke curtain meets the requirements of EN 12101-1.
Smoke tightness tests
Materials class: A2-s1, d0
Quality of cloth1800°F Glass fabric2200°F Glass fabric with coating and stainless-steel inlay
Manufactured in accordance withISO 9001:2008
Floor level
Coupling piece
Galvanised steel bar 26.9mm dia (3/4”)
Smoke curtain cloth
0.6 fixing anchorW-FA, type 08-15
60/100/2.0 angle
5/10 rivet
10/30/10/1.5 clamp profile
“Duo” adhesive tape
60
75
100
50
Coupling piece
>250
0mm
Hei
ght f
rom
500
mm
to m
ax.
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | UL 10 D
This category covers fire-protective curtains intended for applications in buildings where supplemental fire or smoke protection is desired. These products are intended to provide nonstructural separation only, and are not intended to be employed where structural hourly-rated partitions or protectives requiring hose-stream performance are required by code.
Fire-protective curtains are intended to provide supplemental passive fire protection as part of an engineered fire-protection system. These devices are retained on a motorized retractable coil, which can be controlled through the fire-alarm circuit of the building. The curtains are intended to be deployed on command by the fire-alarm system.
Fire-protective curtains have demonstrated the ability to withstand exposure to a fire-endurance test conducted in accordance with the standard-time temperature curve of ANSI/UL 263, “Fire Tests of Building
Construction and Materials,” under positive pressure, without the development of through openings in the curtain, or flaming of the curtain material on the unexposed side of the assembly, for the duration of the hourly rating. In addition, the following performance criteria is applied:
Vertical through openings between the edge of the curtain and a fixed curtain track (if employed) are limited to 3/8-in. wide maximum.Vertical through openings between the curtain track assembly (if employed) and a partition opening are limited to 3/8-in. wide maximum.Horizontal through openings between the bottom of the curtain and the simulated floor of the test assembly are limited to 3/4-in. high maximum.
The test criteria for fire-protective curtains does not include an impact test (hose-stream test) as it is intended as a supplemental means of fire protection.
GSSN: FIRE PROTECTIVE CURTAINS
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET |
The control panel for automatic smoke and fire curtains operates as sub system to central Fire Alarm System (FAS) or can operate independently.
Electrical Requirements (120VAC, 0.67Amps/ motor)
MODULE FOR ADDITIONAL FUNCTIONS
Additional functions include:
Release via smoke detector / heat detectorRelease via button / hand controlRe-opening of curtain for use by fire-fighters (fire access)Re-opening of curtain in emergency (fire egress)Monitoring of curtain via a safety bottom barLine monitoring for wire-break and short circuit.
SIGNALING MODULE
Signaling outputs include:
The module operates in conjunction with the auxiliary module and is prepared for connection of optional warning devices, e.g. a combined multi-tone siren and/or a strobe light.
CONTROL PANEL
CONTROL PANEL
Optional Uninterruptable Power Supply
MODULE FOR ADDITIONAL FUNCTIONS
NUMBER OFCONTROL GROUPS
SIGNALLING MODULE
NUMBER OF CONTROL GROUPS
Control panels can receive multiple alarm and manual/emergency control inputs to manage multiple zones with immediate full deployment, delayed full deployment, and immediate partial deployment with delayed full deployment. Systems can be fitted to be modified on-site or remotely by certified technicians.
•
••
•
•
•
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET |
Rest position(Curtain up)
Working Position (curtain down)
HWDHold time
Drop 1
FFL
The function of the intermediate position is programmed into the control panel at the factory, onsite, or remotely by a certified technician.
Drop 1 Distance from floor to ntermediate position.Hold Time Curtain remains in the HWD intermediate position before it continues down (Escape Delay).
Item Code: 355876
• Emergency switch to raise smoke or fire
curtains following a fire alarm by any person.
• Flush mounting.
• With hook and screw fixing
• Including RU-E frame
• Stickers supplied separately
• Installed at a height of 35 - 43 ft from FFL
• To accommodate a WF / WN switch Flush mounting.• Cream colour
LT-UP
GA-E housing
EMERGENCY EGRESS
Connected to the connection module.
Sustains normal curtain operation to FAS for locally-required period of time.
* Device may vary depending on system requirements
UPS
DOOR / GATE
EMERGENCYEXIT
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | RELEASE AND CONTROL COMPONENTS
MANUAL CONTROL
Button as the main alarm point with internal button to reset the alarm0.03 in thin break glass to DIN 1249Lockable caseDimensions: 5 in x 5 in x 1in (WxHxD)IP42 IP codeLabel “Close fire curtain”
KEY SWITCH
Key switch for rolling up of smoke or fire curtains following a fire alarm by an authorized person.Flush mounting.Prepared to accommodate a PHZ cylinder lock (in addition). Switching capacity 10A / 250V AC.With hook and screw fixingIncluding RU-E frameCustomizable Label
EMERGENCY SWITCH
Emergency switch to raise smoke or fire curtains following a fire alarm by any person. Flush mounting.With hook and screw fixingIncluding RU-E frameCustomizable LabelInstalled at a height of 35 in - 43 in from FFL
THERMO-DIFFERENTIAL DETECTOR
Alarm indication by red LEDEasy installation with quarter-turn fastenerProtection against theftInsensible to wind and atmospheric pressureNominal temperature 135°F Response class A1R to EN 54-5:Application temperature 77° - 122°FStatic reaction: 129°- 150 ° FVoltage: 9...33V-Operating range from -4°F to 195°F, 10-95% RH100Mm diameter, flat design with base only 2 3/8 in height (standard / relay base)VDS approval no. G 200059
STANDARD BASE
With short spring to facilitate installation and maintenance.Designed to combat incorrect operationSurface or flush cable entryDimensions: H 5/8 in, Ø 4 in
SMOKE AND HEAT SENSORS
CONTROL SWITCH
•••••••••••
•
•
•
••
•
•••••
•
••
•••
•
•••••
SMOKE SENSOR
Photoelectric detection of smoke particlesIn accordance with EN 54-7Optical smoke detector with alarm: clear LED, red when there is an alarmOperating voltage 9 ... 33 VDCCurrent consumption at rest approx 40μA/24VOperating range from -4°F to + 140°F, 10-95% RHDimensions including base: H 2 in, Ø 4 inVDS no. G 200017
•••
•••••
DOOR / GATE
EMERGENCYEXIT
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | SIGNALS AND MONITORING
SIGNALS
MONITORING
Sounder with Xenon strobe light, white plastic housing depending on different wiring even only as strobe light or sounder usable.
Provides protection either for people or for goods.One side has double-sided tape for direct attachment to the bottom bar.The homogeneous, highly insulating material made of PVC is equipped with two internal conductive contact surfaces. In the conductive elastomer there are two copper wires that enable low resistance readings at great lengths.
Consisting of optic sensor for object detection and monitoring of openingsA 24 V to 240 V all-voltage sensor can be operated with either DC or AC voltage. High protection suitable for use in harsh environments.Including reflector and bracket
Multi-tone siren with integrated strobe light in red plastic housing
Knock-outs for cable
Multi-tone siren with integrated strobe light in white plastic housing and orange LED.When activated, makes this announcement between the tones
Sounder with strobe light
KL Contact Safety
RL Optical Safety
Multi-tone siren
Voice announcer
Voltage : 24V DCCurrent: 40 mAProtection class: IP 45Alarm volume level: Adjustable 10 to 109 dBA Dimensions: Ø 4 in x4 in HColoured dome: Orange Operating temperature: 5°F to 104°F
Sectional dimensions: 1/4 in x 1 inLength: 4 in x 2 in Fixing the unit: Double-sided tapeResponse force: min. 4 N Contact travel: < 1/8 inDetection angle: < 122°F
Red LED function display
Shines: When the beam is uninterruptedFlashes: When falling short of the functional reserveOff: When the beam is interrupted
Technical dataVoltage: 24...230V AC/DCNo load current: ≤ 8.5 mAPower consumption: 0,2W at 24V DC
OutputSignal output: Relay, 1 inverterSwitching voltage: 230 volt ACSwitching current: max.2A
General info: Max. operating range: 12mLight source: LEDAmbient light: 90000 Lux
Voltage : 9 - 28V DCCurrent: 20 mAProtection class: IP55Dimensions: Ø 4 in x 3 in HColoured dome: red
Voltage : 20 - 28V DCSound output: 100 dB (A)Language: 95 dB (A)Current: 60 mAProtection class: IP45Alarm volume level: 3 x 3 x 5 in (WxHxD)Dimensions: Ø 4 in x 4 in HOperating temperature: -13°F to 158°F
firecurtaintechnologies.com 585-412-2179 [email protected]
NFPA UL DATA SHEET | INSTALLATION OPTIONSInstallation Options
Fire Curtain Technologies:
Technician visits on site and instructs local team to get the materials unpacked, inventoried and organized.
Get projects started (or finished) with the install and even sign off on the work once completed as time and budget allow.
Fire Curtain Technologies:
Provides installation and technique guides.
Supports outside contractor by email and teleconference.
Fire Curtain Technologies:
Provides installation and technique guides.
Supports customer by email and teleconference.
OnsiteSupervision
1
2
3
OutsideContractor
Self-Perform
Fire Curtain Technologies:
Takes the Installation contract through their Network of Installers.
4
Turn-keyInstallation