Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
65285
S U M M A R Y
1. OPTICAL FIBRE CABLES
Aerial installation cylindrical LOOSE TUBE cable (( layer of flat FRP armour))
4, 6, 12,24 single mode fibres
- see data sheet of the cable ref 65285/1
Aerial installation cylindrical LOOSE TUBE cable (( layer of flat FRP armour))
48 single mode fibres
see data sheet of the cable ref 65285/2
2. PARTICULAR SHEET FOR OPTICAL FIBRE Particular sheet of the optical fibre G 652D
3. IDENTIFICATION
4. DELIVERY CONDITIONS
5 . TABLE OF TEST
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
Réf : 65285/1
DATA SHEET
AERIAL LOOSE TUBE WATERTIGHT CABLE
4,612,24 SINGLE MODE FIBRES
Approximate outer diameter : 16mm
Approximate weight : 195 kg/km
CONSTITUTION
- Non metallic central strength member
- Assembly of 1(2 or 4)tube(s)1.6/2.5mm with 4,6,12 fibres, filled with waterblocking compound+fillers
- Swellable powder in assembly
- Polyethylene inner sheath
- Dielectric armour (FRP)
- Polyethylene outer sheath
MECHANICAL CHARACTERISTICS - BENDING (IEC and EN 60794-1-2 E10 & E11) :
- Minimum kink radius : 205 mm*
- Minimum static bend radius : 205mm*
- TENSILE PERFORMANCE (IEC and EN 60794-1-2 E1) : For aerial installation
- Nominal installation tractive force (span 200 m) : see next sheet*
For underground installation - Maximum admissible tractive force : 1900 daN*
- CRUSH PERFORMANCE (IEC and EN 60794-1-2 E3) : - Maximum load : 40 daN/cm*
- IMPACT PERFORMANCE (IEC and EN 60794-1-2 E4) : - Energy : 20 N.m*
TEMPERATURE RANGE
- Storage -40°C/+70°C
- Installation -5°C/+40°C**
- Operating -30°C/+60°C 0.1 dB/km at 1,55 µm) * : Reversible attenuation
** maximum tensile load during operation (permanent) : 770daN(20°C)
*** : Between -5°C and +5°C, 24 hours storage at 20°C before uncoiling is recommended
PACKING
Delivery length : 4100m , type of drum GV
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
Réf : 65285/1
SPECIFIC CLIMATIC CONDITIONS FOR AERIAL CABLE
2 ) O.F AERIAL OPTICAL FIBRE CABLE
For span = 200 m. (initial sag at 15°C 1.75 %)
Installation Winter 1 Winter 2 Summer 1 Wind
Temperature, °C 15 -10* -30 70 15
Wind, m/s
km/h
0 16.7
60
0
0
0
26.67
96
Frost - 10 10 0 0
Tensile load, daN 314 802 718 262 635
sag, m 3.5 6.78 5.99 4.2 6.1
*Extreme condition
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
Réf : 65285/2
DATA SHEET
AERIAL LOOSE TUBE WATERTIGHT CABLE
48 SINGLE MODE FIBRES
Approximate outer diameter : 17mm
Approximate weight : 265 kg/km
CONSTITUTION
- Non metallic central strength member -
Assembly of 8tubes1.6/2.5mm with 6fibres, filled with waterblocking compound
- Swellable powder in assembly
- Polyethylene inner sheath
- Dielectric armour (FRP)
- Polyethylene outer sheath
MECHANICAL CHARACTERISTICS - BENDING (IEC and EN 60794-1-2 E10 & E11) :
- Minimum kink radius : 205 mm*
- Minimum static bend radius : 205mm*
- TENSILE PERFORMANCE (IEC and EN 60794-1-2 E1) : For aerial installation
- Nominal installation tractive force (span 200 m) : see next sheet*
For underground installation - Maximum admissible tractive force : 2170 daN*
- CRUSH PERFORMANCE (IEC and EN 60794-1-2 E3) : - Maximum load : 40 daN/cm*
- IMPACT PERFORMANCE (IEC and EN 60794-1-2 E4) : - Energy : 20 N.m*
TEMPERATURE RANGE
- Storage -40°C/+70°C
- Installation -5°C/+40°C**
- Operating -30°C/+60°C 0.1 dB/km at 1,55 µm) * : Reversible attenuation
** maximum tensile load during operation (permanent) : 860daN(20°C)
*** : Between -5°C and +5°C, 24 hours storage at 20°C before uncoiling is recommended
PACKING
Delivery length : 4100m , type of drum GV
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
Réf : 65285/2
SPECIFIC CLIMATIC CONDITIONS FOR AERIAL CABLE
2 ) O.F AERIAL OPTICAL FIBRE CABLE
For span = 200 m. (initial sag at 15°C 1.75 %)
Installation Winter 1 Winter 2 Summer 1 Wind
Temperature, °C 15 -10* -30* 70 15
Wind, m/s
km/h
0 16.7
60
0
0
0
26.67
96
Frost - 10 10 0 0
Tensile load, daN 378 904 910 304 787
sag, m 3.5 5.53 5.21 4.35 5.47
*Extreme condition
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
65285
PARTICULAR SHEET FOR OPTICAL FIBRE
REDUCED-WATER-PEAK SINGLE MODE OPTICAL FIBRE (G652D)
NOMENCLATURE
UNIT SPECIFICATION
TECHNOLOGY Coating
EPOXY - ACRYLATE
GEOMETRICAL CHARACTERISTICS
- wavelength
- mode field diameter
- cladding diameter
- coating diameter
- cladding non circularity
- coating/cladding concentricity error
- core/cladding concentricity error
nm
µm
µm
µm
%
µm
µm
1310
9.1 + 0.5
125 + 1
245 + 10
< 1
< 10
< 0.6
TRANSMISSION CHARACTERISTICS
- cabled cut-off wavelength
- attenuation at 1310 nm (1),
at 1383 nm,
at 1550 nm (1),
at 1625 nm
- transmission curve regularity at 1550 nm
- chromatic dispersion between 1285-1330 nm
- chromatic dispersion at 1550 nm
- PMD (value for fibre in cable)
nm
dB/km
dB/km
dB/km
dB/km
dB
ps/nm.km
ps/nm.km
ps/km 1/2
cc < 1260
< 0.36 (1)
< 0.35
< 0.22 (1)
< 0.26
< 0.1
< 3.5
< 18
< 0.2
STANDARD
ITU-T Recommendation
G652 D
(1) : 10 % of the fibres (in cable) presented in reception can have an attenuation :
< 0.38 dB/km at 1310 nm
< 0.23 dB/km at 1550 nm
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
Réf : 65285
IDENTIFICATION
1. MARKING.
Hot foil marking every meter on cable outer sheath.
We propose the following marking
" Week Year number of fibre OF SM G652D SILEC " + metric marking
Metric marking will be expressed in meters.
2 .IDENTIFICATION.
Colour-coding of tube and fibres in each tube :
Fibre colour code :
red, blue, green, yellow, violet, white , orange , grey, brown, black, aquamarine, pink.
Tube colour code
red, blue, green, yellow, violet, white , orange , grey
3. DRUM IDENTIFICATION
The following information are included on a plate or label fixed on the drum:
- Cable description,
- Cable code,
- Length and weight of drum,
- Drum number,
- Order number,
- Year of manufacture,
- SILEC CABLE
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
65285
DELIVERY CONDITIONS
1. CABLE LENGTHS.
Standard delivery lengths: L ± 3 % (value of L: refer to cable particular sheet)
Provisions for irregular lengths:
- up to 10% of the total order length (with a minimum of one L length) may be split in two equal L/2 lengths
- up to 10% of the total order length (with a minimum of one length) may be delivered in irregular lengths
1000m
2. SEALING OF ENDS.
Each cable end is sealed with an heat-shrinkable cap.
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
65285
1/2
TABLE OF TESTS
1 / ROUTINE TESTS
We propose routine tests according to the following table.
Tests
Reference
Sampling
SILEC
CABLE
Acceptance
(*)
Dimensional
- outer diameter
- thickness of the sheath
- identification
Optical and transmission
- attenuation (1) in the
specified window(s)
- regularity of attenuation
at 1550 nm(SM) or 850
nm(MM)
Mechanical on the outer sheath
- tensile strength
- elongation at break
Environment
- water penetration (2)
IEC 60811-1-1
IEC 60793-1-40-C
back-scattering
Method
IEC 60811-1-
EN 50290-2-24 (PE)
IEC 60794.1.2-F5B
1 cable (a)
"
"
100 %
100 %
1 cable (b)
"
1 cable (c)
1 cable
"
"
10 % of cable
(10 % of OF)
"
1 cable
"
1 cable
(*) Acceptance test program to be agreed between customer and SILEC at the time of ordering.
Nota : (a) : 1 test/design of cable / week
(b) :1 test per period/ type of outer sheath/ manufacture line
Period = 1 month if PE sheath
(c) : 1 test/design of cable /month
(1) attenuation :
Backscattering measurements performed from one cable end (1.55 µm for SM OF / 0.85/1.3 µm for MM OF)
+ optical continuity for all fibres.
In case of limit values, the measurement will perform from both ends and the attenuation is the average of the
both values. In case of doubt, the attenuation will be determined by the cut-back reference method (IEC
60793-1-40-A).
Attenuation value is significant only for cable length 1 km
For cable length < 1km, only the regularity of transmission at 1550 nm (SM) or 850 nm (MM) will be
controlled.
Exclusive property of SILEC CABLE. No copy or diffusion without the written consent of SILEC CABLE. SILEC trademark is a registered trademark.
65285
2/2
TABLE OF TESTS
(Following)
(2) Water penetration test
Applicable to the whole cable or only to watertight parts, according to cable design and specifications.
Conditions : sample length : 3 meters; water height: 1 m; duration: 24 hours
2 / TYPE TESTS (not included in cable’s price) :
We perform ISO 9001 certified Quality Assurance system and internal test procedures ensuring that the
cables supplied meet the requirements of customer.
In this framework, type tests are carried out when initially designing/developing the given cable type,
and are not intended to be repeated on every order or manufactured cable length.
However, on customer's request, the renewal of some type tests may be considered as part of the order
acceptance program, providing an agreement has been reached between the customer and SILEC at the time
of ordering, including, if any, the specific conditions applicable to the implementation of the tests.
Alternatively, certificates of conformity or test reports, relating to previous supplies and/or qualification
programs of same or similar cable type, can be provided as part of the technical documentation pertaining to
the order.
For information, the following table shows the main type tests relevant to the proposed type of cable and
supporting the characteristics stated in the cable particular data sheet.
Reference
IEC 60794.1.2-
EN 60794.1.2
- tensile resistance
- crush resistance
- impact resistance
- kink resistance
- bending resistance
- temperature cycling
E1
E3
E4
E10
E11
F1