13
Catalogue 2007 a Nexans company

a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

Embed Size (px)

Citation preview

Page 1: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

Catalogue 2007

a Nexans company

Page 2: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

0�/2

007

EUROMOLDCOMPANY PRESENTATION

While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products

described in this catalogue as standards and technology evolve.

EUROMOLDEuromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of acces-sories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminationsand joints for cables and epoxy bushings for transformers and switch gear, as well as a large range of cold-shrinkable terminations and joints from �2 to 42 kV.Euromold is also the manufac-turer of electrical components for the high voltage accessories of the Nexans group.

ISO 9001 CertificateSince �992, Euromold’s commitment to quality is demonstrated by its ISO 900� certification.

Laboratory accreditationSince June 2000, Euromold’s independent ELAB laboratory obtained the BELTEST accredi-tation no.�92-T-ISO �7025 conform with the European standards for laboratories ISO �7025 for electrical testing of medium voltage cable acces-sories according to the Inter-national standards IEC 6�442 and HD 629.

International standardsAll our products meet the International standards like CENELEC HD 629.�, CENELEC EN 50�80, IEC 60�37, IEEE 386 & 404… or country speci-fications. Official certificates, CESI, KEMA, ATEX… prove the conformity of our products. Long duration tests of existing or new products are con-tinuously performed in our test fields.

Page 3: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

2

0�/2

007

5/8" - 11UNC-2B

Dia. 32 nominal

Dia. 61.5± 0.2

Dia. 39.9± 0.2

31.75± 0.4

1.5 0 - 0.5

25.4min.

103.7± 0.2

Dia. 76.2± 0.2

14.8 min.

SEPARABLE CONNECTORSAND BUSHINGS

INTERFACE E - 5/8"

Table of contents750LR & 775LR - tee connector750S�, 775S� & 775T� - equipment bushingFixings for equipment bushingsAccessoriesPossible arrangements

INTERFACE E - 5/8"Dimensions according to ANSI/IEEE std. 386 (in mm, except where noted).

Page 4: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

3

Connecting possibilities

750CP or 775CPConnecting plug

750BIP or 775BIPBasic insulating plug

750BE or 775BEBushing extender

750DP or 775DPDead-end plug

cable earthing

750LR or 775LRTee connector

775T1Equipment bushing

750SOPStand-off plug

750GPEarthing plug

750BE or 775BE 750CP or 775CP750S1 or 775S1Equipment bushing

cable isolation

Bushing extender Connecting plug

CONNECTIONBUSHINGS /ACCESSORIES

CONNECTORS / ACCESSORIES

dead-ending

of equipment

one cable to

equipment

in-line junction

dead-ending

of connector

connector standingaway from equipment

Equipmentinterface

Page 5: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

4

0�/2

007

Up to 36 kV 800 A & 1250 A

Separable connector

type

VoltageUm(kV)

CurrentIr

(A)

Conductor sizes (mm2)

min. max.

750LR

775LR

36

36

800

�250

35

35

630

630

750LR & 775LRINTERFACE E - 5/8"

TEE CONNECTOR

ApplicationSeparable tee connector (bolted 5/8" type) designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors...).Also connects cable to cable, using the appropriate mating part.

Technical characteristics• A thick conductive EPDM

jacket provides a total safe to touch screen.

• Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.

6/10 (12) kV6.35/11 (12) kV

8.7/15 (17.5) kV12/20 (24) kV

12.7/22 (24) kV18/30 (36) kV

Specifications and standardsThe separable connectors 750LR and 775LR meet the requirements of CENELEC HD 629.�.

DesignSeparable connector comprising: �. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type E interface as described in ANSI/IEEE std. 386. 5. Threaded stud 5/8". 6. Conductor connector. 7. Cable reducer. 8. Dead end plug (with VD point). 9. Conductive rubber cap. �0. Cable adaptor.

295 mm260 mm

355 mm

9

3

1

4

6

10

8

5

7

2

Page 6: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

5

Kit contentsThe complete 750LR or 775LR tee connector kit comprises the following components:

The kit also comprises lubricant, wipers,

installation instructions and crimp chart.

For use withother cable types.

Please contact our representative.

For outdoorapplications.

Order: +MWS.

Components can be ordered individually.

For use withcopper tape

screened cables. Order: Kit MT.

For use with fabric tape (graphite) screened cables.

Order additionalsemi-conductive tape

(type TSC).

+ + + + = 750LR-W-X1+��TL

or

775LR-W-X2+��TL

connector kit

Ordering instructionsSelect the part number which gives the best centring to the cable core insulation diameter.

Example:The copper wire screened cable is 36 kV, 300 mm2 stranded aluminium with a diameter over core insulation of 38.8 mm.Order a 750LR-M-300KM-�0-2+��TL tee connector kit for+��TL tee connector kit for tee connector kit for 800 A application.

Table W

Table X

Ordering partnumber - 800 A

Ordering partnumber - 1250 A

Dia. over core insulation (mm)min. max.

750LR-G-X1+��TL

750LR-H-X1+��TL

750LR-J-X1+��TL

750LR-K-X1+��TL

750LR-L-X1+��TL

750LR-M-X1+��TL

750LR-N-X1+��TL

750LR-P-X1+��TL

750LR-Q-X1+��TL

775LR-G-X2+��TL

775LR-H-X2+��TL

775LR-J-X2+��TL

775LR-K-X2+��TL

775LR-L-X2+��TL

775LR-M-X2+��TL

775LR-N-X2+��TL

775LR-P-X2+��TL

775LR-Q-X2+��TL

�9.3

2�.6

24.9

27.7

30.0

34.8

38.5

43.8

48.3

24.�

26.7

30.0

33.3

37.2

4�.�

45.2

49.�

53.9

Conductorsizes

(mm²)

Table X1: 800 A Table X2: 1250 A

Aluminium conductor Copper conductor Aluminium conductor Copper conductor

DINhexagonal

Deepindent

DINhexagonal

DINhexagonal

Deepindent

DINhexagonal

35507095�20�50�85240300400500630

35(K)M-�0-250(K)M-�0-270(K)M-�0-295(K)M-�0-2�20(K)M-�0-2�50(K)M-�0-2�85(K)M-�0-2240(K)M-�0-2300(K)M-�0-2400(K)M-�0-2500(K)M-�0-2630(K)M-�0-2

35KM-�0-�50(K)M-�0-�70(K)M-�0-�95(K)M-�0-��20(K)M-�0-��50(K)M-�0-��85(K)M-�0-�240(K)M-�0-�300(K)M-�0-�400(K)M-�0-�500(K)M-�0-�630(K)M-�0-�

35(K)M-�450(K)M-�470(K)M-�495(K)M-�4�20(K)M-�4�50(K)M-�4�85(K)M-�4240(K)M-�4300(K)M-�4400(K)M-�4500(K)M-�4630(K)M-�4

35(K)M-�2-250(K)M-�2-270(K)M-�2-295(K)M-�2-2�20(K)M-�2-2�50(K)M-�2-2�85(K)M-�2-2240(K)M-�2-2300(K)M-�2-2400(K)M-�2-2500(K)M-�2-2630(K)M-�2-2

35KM-�2-�50(K)M-�2-�70(K)M-�2-�95(K)M-�2-��20(K)M-�2-��50(K)M-�2-��85(K)M-�2-�240(K)M-�2-�300(K)M-�2-�400(K)M-�2-�500(K)M-�2-�630(K)M-�2-�

35(K)M-��-250(K)M-��-270(K)M-��-295(K)M-��-2�20(K)M-��-2�50(K)M-��-2�85(K)M-��-2240(K)M-��-2300(K)M-��-2400(K)M-��-2500(K)M-��-2630(K)M-��-2

Connector housing

750BLR

Cable

adaptor

��TL

Conductor

contact

TBC-X1or TBC-X2

Dead end plug

+ rubber cap

750DP

or 775DP

Cable reducer

755CA-W

For use with copper wire screened cables.

No earthing device is necessary.

Page 7: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

6

0�/2

007

Up to 36 kV 800 A & 1250 A

750S1, 775S1 & 775T1INTERFACE E - 5/8"

EQUIPMENT BUSHING

ApplicationFor use in equipment insulated with oil fluid, typically for transformers, switch gear, capacitors...

DesignThe equipment bushing is amoulded epoxy insulated part inaccordance with ANSI/IEEE 386std. (5/8" threading system).

Technical characteristics Each bushing is tested forAC withstand and partial discharge prior to leavingthe factory.

Specifications and standardsThe bolted type equipment bushings 750S�, 775S� and 775T� meet the requirements of IEC 60�37.

Ordering instructionsTo order the equipment bushing, specify the type.

In mm, except where noted.

6/10 (12) kV6.35/11 (12) kV

8.7/15 (17.5) kV12/20 (24) kV

12.7/22 (24) kV18/30 (36) kV

Equipmentbushing

type

VoltageUr

(kV)

CurrentIr

(A)

Dimensions (mm)

A B

750S�

775S�

775T�

36

36

36

800

�250

�250

75

75

22�

235

235

378

1.5

A

B

32

stainlesssteel flange

Dia. 76

Dia. 114

Minimumoil level:70 mm

5/8”-11UNC-2A

5/8”-11UNC-2B

Dia.32

Page 8: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

7

0�/2

007

FIXINGS FOR EQUIPMENT BUSHINGS

INTERFACE E - 5/8"

750S1, 775S1 and 775T1 bushings

fixing flangetype : MK 600-1(antimagnetic)

fixing studs andnuts M10

sealing gasket

bushing interface

equipmentconnection

equipment

140

170

60°

60°

10

In mm.

Page 9: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

8

0�/2

007

ACCESSORIESINTERFACE E - 5/8"

Up to 36 kVApplicationFor use with connectors and bushings with an INTERFACE E - 5/8" as described in ANSI/IEEE std. 386.

6/10 (12) kV6.35/11 (12) kV

8.7/15 (17.5) kV12/20 (24) kV

12.7/22 (24) kV18/30 (36) kV

Technical characteristics All these products, except theearthing plug, are tested forAC withstand and partial discharge prior to leavingthe factory.

Ordering instructionsOrder 750DP for 800 A or775DP for �250 Aapplications.

750DP & 775DPDead-end plugActs as a tightening nut for the 750LR and 775LR tee connector kits.The plug contains a voltage detection point.The threaded stud and conductive rubber protecting cap is included.

750CP & 775CPConnecting plugFor connecting two or more connectors with a type E - 5/8" interface together, thus creating a separable cable joint or a multiple cable connection to equipment.

Ordering instructionsOrder 750CP for 800 A or775CP for �250 Aapplications.

750BIP & 775BIPBasic insulating plugActs as a tightening nut for the 750LR and 775LR tee connector kits.The plug contains a voltage detection point.The conductive rubber protecting cap is included.The 750BIP and 775BIP are supplied without threaded stud.

Ordering instructionsOrder 750BIP for 800 A or775BIP for �250 Aapplications.

Page 10: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

9

Kit MTEarthing kit for copper tape screened cablesContains a tinned copper braid (25 mm² - L = 500 mm), a tinned copper wire for cleating and water sealing mastic.

Ordering instructionsOrder Kit MT for 800 A and �250 Aapplications.

Ordering instructionsOrder 750GP for 800 A and �250 Aapplications.

750SOPStand-off plugIs designed to support and 'dead-end' connectors with a type E - 5/8" interface when removed from equipment.

Ordering instructionsOrder 750SOP for 800 A and �250 Aapplications.

750BE & 775BEBushing extenderProvides an extension piece to allow cables to stand away from equipment. Is used in conjunction with the connecting plug (750CP or 775CP).

Ordering instructionsOrder 750BE for 800 A or775BE for �250 Aapplications.

750GPEarthing plugIs designed to support and earth connectors with a type E - 5/8" interface when removed from equipment.

Page 11: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

�0

0�/2

007

POSSIBLE ARRANGEMENTSINTERFACE E - 5/8"

750LR or 775LRSingle cable arrangement.Order 750LR or 775LR for �2 kV, 24 kV or 36 kV applications.

750LR-P2 or 775LR-P2Dual cable arrangement.Order 750LR-P2 or 775LR-P2for �2 kV, 24 kV or 36 kV applications.

750LR-P6 or 775LR-P6Connector standing away from equipment.Order 750LR-P6 or 775LR-P6 for �2 kV, 24 kV or 36 kV applications.

750LR-P3 or 775LR-P3Triple cable arrangement.Order 750LR-P3 or 775LR-P3for �2 kV, 24 kV or 36 kV applications.

295

dead-endplug

130 280

575

connectingplug

dead-endplug

130

130 280 280

855

dead-endplug

connectingplug

connectingplug

410

575

bushingextender

dead-endplug

connectingplug

In mm.

Page 12: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

��

750LR-L1 or 775LR-L1Dead-ending.Order 750LR-L� or 775LR-L� for �2 kV, 24 kV or 36 kV applications.

750LR-L2 or 775LR-L22-way connection.Order 750LR-L2 or 775LR-L2 for �2 kV, 24 kV or 36 kV applications.

750LR-L3 or 775LR-L33-way connection.Order 750LR-L3 or 775LR-L3 for �2 kV, 24 kV or 36 kV applications.

Connector on stand-off plug.

Connector on earthing plug.

330

basicinsulating

plug

dead-endplug

610

basicinsulating

plug

connectingplug

dead-endplug

890

basicinsulating

plug

dead-endplug

connectingplug

connectingplug

stand-offplug

dead-endplug

earthingplug

dead-endplug

In mm.

Page 13: a Nexans company INTERFACE E CONNECTORS.pdf3 Connecting possibilities 750CP or 775CP Connecting plug 750BIP or 775BIP Basic insulating plug 750BE or 775BE Bushing extender 750DP or

Additional catalogue information on power cable accessoriesis available by contacting us at the address below:

Nexans Network Solutions N.V. - Div. Euromold • Zuid III, Industrielaan �2, B-9320 ErembodegemTel.: +32 (0)53 85 02 �� • Fax: +32 (0)53 83 �0 �3 • www.nexans.com • [email protected]

Catalogue also available on CD-ROM

Distributed by:

0�/2

007