Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Catalogue 2007
a Nexans company
�
0�/2
007
EUROMOLDCOMPANY PRESENTATION
While every care is taken to ensure that the information contained in this publication is correct, no legal responsibility can be accepted for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold reserves the right to alter or modify the characteristics of its products
described in this catalogue as standards and technology evolve.
EUROMOLDEuromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution. Euromold provides a complete range of acces-sories for underground cables: pre-moulded EPDM or silicone rubber connectors, terminationsand joints for cables and epoxy bushings for transformers and switch gear, as well as a large range of cold-shrinkable terminations and joints from �2 to 42 kV.Euromold is also the manufac-turer of electrical components for the high voltage accessories of the Nexans group.
ISO 9001 CertificateSince �992, Euromold’s commitment to quality is demonstrated by its ISO 900� certification.
Laboratory accreditationSince June 2000, Euromold’s independent ELAB laboratory obtained the BELTEST accredi-tation no.�92-T-ISO �7025 conform with the European standards for laboratories ISO �7025 for electrical testing of medium voltage cable acces-sories according to the Inter-national standards IEC 6�442 and HD 629.
International standardsAll our products meet the International standards like CENELEC HD 629.�, CENELEC EN 50�80, IEC �37, IEEE 386 & 404… or country specifica-tions. Official certificates, CESI, KEMA, ATEX… prove the con-formity of our products. Long duration tests of existing or new products are continuously performed in our test fields.
2
0�/2
007
SEPARABLE CONNECTORSAND BUSHINGS
INTERFACE C
Interface CDimensions according to European CENELEC EN 50�80 and 50�8� (in mm).
M16 x 2 - 6H
11 min.
Dia. 56± 0,2
Dia. 46± 0,2
Dia. 22min.
1,5 0 - 0,5
29min.
90± 0,2
Dia. 70± 0,2
Table of contents400LB - elbow connector430TB-630A - tee connector400TB - tee connector440TB - tee connector300PB-630A - coupling connector400AR-3 - equipment bushing400A-24B - in-air bushingFixings for equipment bushings400PB-XSA - surge arrester400TR & 400TR-LB - test rod400TK-400SW installation toolsAccessoriesPossible arrangements
3
Connecting possibilities
BUSHINGS /ACCESSORIES
CONNECTION CONNECTORS /ACCESSORIES
cable
earthing
tap-off
630/250A
cable
isolation
in-line
junction
one cable to
equipment
dead-ending
of equipment (K)(M)400DR-BDead-end receptacle
in-line
junction
(K)430TB-630ATee connector
(K)400LBElbow connector
(K)(M)(P)400TB/GTee connector
(K)(M)440TB/GTee connector
Equipmentinterface
400GP-BEarthing plug
(K)400RTPAReducing tap plug
(K)(M)400SOP-BStand-off plug
(K)(M)440CPConnecting plug
(K)(M)400AR-3Equipment bushing
400A-24BIn-air bushing
(K)(M)400CP-SCConnecting plug
6
0�/2
007
ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors, ...).Also connects cable to cable when using the appropriate mating parts.
Technical characteristics• A thick conductive EPDM
jacket provides a total safe to touch screen.
• Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.
Specifications and standardsThe separable connector 430TB-630A meets the requirements of CENELEC HD 629.�.
Up to 24 kV - 630 A
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor sizes (mm2)
min. max.430TB-630A
K430TB-630A
�2
24
630
630
35
35
300
300
Design �. Type C - 630 A interface as described by CENELEC EN 50�80 and 50�8�. 2. Clamping screw. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive rubber cap. 7. Basic insulating plug (standard version without voltage detection point). 8. Conductor connector 9. Cable reducer. �0. Earthing lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
430TB-630AINTERFACE C
TEE CONNECTOR
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV
183 mm
Non-size sensitive:290 mm
Size sensitive:350 mm
3
4
5
7
6
8
9
2
1
10
7
Kit contentsThe complete (K)430TB-630A tee connector kit comprises 3 x the following components:
The kit also comprises lubricant, wipers, water sealing mastic, installation rod, installation instructions and crimp chart.
Ordering instructionsTo order the tee connector, use the tables beside to substitute for W1/W2 and X in the formulas.
�. From table W1 or W2: select the symbol which gives the best centring of your core insulation diameter.
2. From table X: according to your conductor size and type, select the designation which completes the part number.
Example:The cable is 24 kV, �50 mm2 compact stranded copper with a diameter over core insulation of 27.5 mm.Order 3 x K430TB-�8-95.240-�4-5 for a non-size sensitive application or 3 x K430TB-22-�50(K)M-��-2 for a size sensitive application.
Clamping screw
430TCS
Basic insu-lating plug + rubber
cap 300BIPRConnector housing
430BT-630A
Cable reducer430CA-W1
Cable reducer4��CA-W2
Conductorcontact TMBC-X
Conductor contact TBC-X
+ + +
+
+
= 3 x (K)430TB-W1-X connector kit for non-size sensitive
application
3 x (K)430TB-W2-X connector kit for
size sensitiveapplication
=
non-sizesensitive
sizesensitive
Table W1 Table W2
Dia. over coreinsulation (mm) W2
min. max.
�2.0
�6.0
20.0
23.5
26.5
28.5
�7.5
22.0
26.5
3�.0
32.5
37.5
��
�5
�9
22
25
27
For use witheasy strip semi-conductive screened cables. Order: Field control mastic
(type MFC).
Basic insulating plug also available with a voltage
detection point.Order : - /VD.
Table X
For use withother cable types.
Please contact our representative.
For outdoorapplications.
Order: +MWS.
For use withcopper tape
screened cables. Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact our representative.
VoltageUm (kV) Non-size sensitive Size sensitive
�2
243 x 430TB-W1-X
3 x K430TB-W1-X3 x 430TB-W2-X
3 x K430TB-W2-X
Dia. over coreinsulation (mm) W1
min. max.
�2.0
�7.0
�9.0
�7.5
23.5
32.6
��
�6
�8
Conduc-tor sizes (mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
BoltedDIN
hexagonalBolted
35
50
70
95
�20
�50
�85
240
300
35(K)M-�0-2
50(K)M-�0-2
70(K)M-�0-2
95(K)M-�0-2
�20(K)M-�0-2
�50(K)M-�0-2
�85(K)M-�0-2
240(K)M-�0-2
300(K)M-�0-2
35KM-�0-�
50(K)M-�0-�
70(K)M-�0-�
95(K)M-�0-�
�20(K)M-�0-�
�50(K)M-�0-�
�85(K)M-�0-�
240(K)M-�0-�
–
35(K)M-��-2
50(K)M-��-2
70(K)M-��-2
95(K)M-��-2
�20(K)M-��-2
�50(K)M-��-2
�85(K)M-��-2
240(K)M-��-2
300(K)M-��-2– –
8
0�/2
007
Up to 41.5 kV - 630 A
400TBINTERFACE C
TEE CONNECTOR
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV18/30 (36) kV19/33 (36) kV
20.8/36 (41.5) kV
Technical characteristics • The thick conductive EPDM
jacket provides a total safe to touch screen which ensures safety for personnel.
• Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.
Separable connector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor size (mm2)
min. max.
400TB/G
K400TB/G
M400TB/G
P400TB/G
�2
24
36
4�.5
630
630
630
630
35
35
35
35
300
300
240
240
ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors, ...).Also connects cable to cable when using the appropriate mating parts.
DesignSeparable connector comprising: �. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer. 4. Type C - 630 A interface as described by CENELEC EN 50�80 and 50�8�. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw. �0. Earthing lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
Specifications and standardsThe separable connector 400TB meets the requirements of CENELEC HD 629.� S�.
255 mm
220 mm
390 mm
3
2
1
4
56
7
8
10
9
9
For use withother cable types.
Please contact our representative.
For outdoorapplications.
Order: +MWS.
Components can be ordered individually.
For use withcopper tape
screened cables. Order: Kit MT.
For use with Alupe orC 33-226 cables.
Please contact our representative.
For use in potentially explosive atmospheres
(for �2 kV max.). Order: -/ATEX.
Kit contentsThe complete (K)(M)(P)400TB/G tee connector kit comprises the following components:
The kit also comprises lubricant, wipers,
installation instructions and crimp chart.
Ordering instructionsTo order the tee connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV, an 'M' for use up to 36 kV or add a 'P' for use up to 4�.5 kV.
Orderingpart number
Dia. over core insulation (mm)
min. max.
400TB/G-��-X400TB/G-�5-X400TB/G-�9-X400TB/G-22-X400TB/G-25-X400TB/G-27-X
�2.0
�6.0
20.0
23.5
26.5
28.5
�7.5
22.0
26.5
3�.0
32.5
37.5
Example:The copper wire screened cable is 36 kV, �50 mm2 stranded copper with a diameter over core insulation of 32.5 mm.Order a M400TB/G-27-�50(K)M-��-2 tee connector kit.
Connector housing
(K)(M)(P)400BT/G
Clamping
screw
400TCS
Conductor
contact
TBC-X
Basic insulating
plug +
rubber cap
(K)(M)(P)400BIPA
Cable reducer
4��CA-W
(K)(M)(P)400TB/G-W-Xconnector kit
Table W
Table X
Conductor size (mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
DINhexagonal
35
50
70
95
�20
�50
�85
240
300
35(K)M-�2-2
50(K)M-�2-2
70(K)M-�2-2
95(K)M-�2-2
�20(K)M-�2-2
�50(K)M-�2-2
�85(K)M-�2-2
240(K)M-�2-2
300(K)M-�2-2
35KM-�2-�
50KM-�2-�
70KM-�2-�
95KM-�2-�
�20KM-�2-�
�50KM-�2-�
�85KM-�2-�
240KM-�2-�
300KM-�2-�
35(K)M-��-2
50(K)M-��-2
70(K)M-��-2
95(K)M-��-2
�20(K)M-��-2
�50(K)M-��-2
�85(K)M-��-2
240(K)M-��-2
300(K)M-��-2
+ + + + =
�0
0�/2
007
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV18/30 (36) kV
Up to 36 kV - 630 A
440TBINTERFACE C
TEE CONNECTOR
Technical characteristics • The thick conductive EPDM
jacket provides a total safe to touch screen which ensures safety for personnel.
• Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.
ApplicationSeparable tee shape connector (bolted type) designed to connect polymeric insulated cable to equipment (transformers, switch gear, motors, ...).Also connects cable to cable when using the appropriate mating parts.
DesignSeparable connector comprising: �. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type C - 630 A interface as described by CENELEC EN 50�80 and 50�8�. 5. Conductor connector. 6. Basic insulating plug (with VD point). 7. Cable reducer. 8. Conductive rubber cap. 9. Clamping screw. �0. Earthing lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
Specifications and standardsThe separable connector 440TB meets the requirements of CENELEC HD 629.�.
Separable connector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor sizes (mm2)
min. max.440TB/G
K440TB/G
M440TB/G
�2
24
36
630
630
630
�85
�85
�85
630
630
630
400 mm
3
2
1
4
5
7
6 8
10
9
255 mm220 mm
��
Kit contentsThe complete (K)(M)440TB/G tee connector kit comprises the following components:
The kit also comprises lubricant, wipers,
installation instructions and crimp chart.
Ordering instructionsTo order the tee connector, select the ordering part number which gives you the best centring of your core insula-tion diameter and substitute X using table X, according to your conductor size and type.Add a 'K' for use up to 24 kV and add an 'M' for use up to 36 kV.
Orderingpart number
Dia. over core insulation (mm)
min. max.
440TB/G-22-X440TB/G-27-X440TB/G-32-X440TB/G-37-X440TB/G-43-X
23.5
28.5
34.0
39.0
45.5
3�.0
37.5
42.5
48.5
56.0
Example:The copper wire screened cable is 36 kV, 240 mm2 stranded aluminium with a diameter over core insulation of 37.0 mm.Order a M440TB/G-32-240(K)M-�2-2 tee connector kit.
When installed on an appropriate equipment
bushing: �250 A continuously
For use withcopper tape
screened cables. Order: Kit MT.
+ + +
Connector housing
(K)(M)440BT/G
Clamping
screw
400TCS
Conductor
contact
TBC-X
Basic
insulating
plug +
rubber cap
(K)(M)400BIPA
+
Cable reducer
6��CA-W
= (K)(M)440TB/G-W-Xconnector kit
Table W
Table X
Conductor sizes (mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
DINhexagonal
�85
240
300
400
500
630
�85(K)M-�2-2
240(K)M-�2-2
300(K)M-�2-2
400(K)M-�2-2
500(K)M-�2-2–
�85KM-�2-�
240KM-�2-�
300KM-�2-�
400KM-�2-�
500KM-�2-�
630KM-�2-�
�85(K)M-��-2
240(K)M-��-2
300(K)M-��-2
400(K)M-��-2
500(K)M-��-2
630(K)M-��-2
For use withother cable types.
Please contact our representative.
For outdoorapplications.
Order: +MWS.
Components can be ordered individually.
For use in potentially explosive atmospheres
(for �2 kV max.). Order: -/ATEX.
�2
0�/2
007
ApplicationSeparable coupling connector (bolted type) for dual cable arrangement. It has been designed to be used with separable Tee connector 430TB-630A. Total maximum current is 630 A.
Technical characteristics• A thick conductive EPDM
jacket provides a total safe to touch screen.
• Each separable connector is tested for AC withstand and partial discharge prior to leaving the factory.
Up to 24 kV - 630 A
300PB-630ACOUPLING CONNECTOR
FOR 430TB-630A
Separableconnector
type
VoltageUm(kV)
CurrentIr
(A)
Conductor sizes (mm2)
min. max.300PB-630A
K300PB-630A
�2
24
630
630
35
35
300
300
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV
3
2
1
4
5
7
8
10
9
Non-size sensitive:290 mm
Size sensitive:350 mm
105 mm
290 mm
11
6
Specifications and standardsThe 300PB-630A coupling connector meets the requirements of CENELEC HD 629.� for �0 and 20 kV levels.
Design �. Interface designed to fit 430TB-630A connector. 2. Bus for 300PB. 3. Conductive EPDM insert. 4. Insulating EPDM layer moulded between the insert and the jacket. 5. Conductive EPDM jacket. 6. Conductive EPDM cap. 7. Basic insulating plug. 8. Conductor connector (hexagonal crimping, deep indent crimping or bolted). 9. Cable reducer. �0. Clamping screw. ��. Earth lead.
The screen break designenables cable outer sheathtesting without removing ordismantling the connector.
�3
Kit contentsThe complete (K)300PB-630Acoupling connector kit comprises 3 x the following components:
The kit also comprises silicone grease,
water sealing mastic, installation rod,
installation instructions and crimp chart.
Ordering instructionsTo order the Tee connector, use the tables beside to substitute for W1/W2 and X in the formulas.
�. From table W1 or W2: select the symbol which gives the best centring of your core insulation diameter.
2. From table X: according to your conductor size and type, select the designation which completes the part number.
Example:The cable is 24 kV, �50 mm2 compact stranded copper with a diameter over core insulation of 27.5 mm.Order 3 x K300PB-�8-95.240-�4-5 for a non-size sensitive application or 3 x K300PB-22-�50(K)M-��-2 for a size sensitive application.
Clamping screw
300PB-CS
Connector housing300BPB-630A
+
For use withcopper tape
screened cables. Order: Kit MT.
For use witheasy strip semi-conductive screened cables. Order: Field control mastic
(type MFC).
For use with copperwire screened cables.
No earthingdevice is
necessary.
For use withother cable types.
Please contact our representative.
For outdoorapplications.
Order: +MWS.
Cable reducer430CA-W1
Cable reducer4��CA-W2
Conductorcontact TMBC-X
Conductor contact TBC-X
+
+
+
= 3 x (K)300PB-W1-X connector kit for non-size sensitive
application
3 x (K)300PB-W2-X connector kit for
size sensitiveapplication
=
non-sizesensitive
sizesensitive
For use with fabric tape (graphite) screened cables.
Order additionalsemi-conductive tape
(type TSC).
VoltageUm (kV) Non-size sensitive Size sensitive
�2
243 x 300PB-W1-X
3 x K300PB-W1-X3 x 300PB-W2-X
3 x K300PB-W2-X
Table W1 Table W2
Dia. over coreinsulation (mm) W2
min. max.
�2.0
�6.0
20.0
23.5
26.5
28.5
�7.5
22.0
26.5
3�.0
32.5
37.5
��
�5
�9
22
25
27
Table X
Dia. over coreinsulation (mm) W1
min. max.
�2.0
�7.0
�9.0
�7.5
23.5
32.6
��
�6
�8
Conduc-tor sizes (mm2)
Aluminium conductor Copper conductor
DINhexagonal
Deepindent
BoltedDIN
hexagonalBolted
35
50
70
95
�20
�50
�85
240
300
35(K)M-�0-2
50(K)M-�0-2
70(K)M-�0-2
95(K)M-�0-2
�20(K)M-�0-2
�50(K)M-�0-2
�85(K)M-�0-2
240(K)M-�0-2
300(K)M-�0-2
35KM-�0-�
50(K)M-�0-�
70(K)M-�0-�
95(K)M-�0-�
�20(K)M-�0-�
�50(K)M-�0-�
�85(K)M-�0-�
240(K)M-�0-�
–
35(K)M-��-2
50(K)M-��-2
70(K)M-��-2
95(K)M-��-2
�20(K)M-��-2
�50(K)M-��-2
�85(K)M-��-2
240(K)M-��-2
300(K)M-��-2– –
�8
0�/2
007
ApplicationSurge arrester designed to protect �2 and 24 kV class components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching.
Up to 36 kV
400PB-XSAINTERFACE C
SURGE ARRESTER
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV18/30 (36) kV
Technical characteristics • This surge arrester is a metal
oxide varistor surge arrester in an elbow configuration.
• Each arrester is tested for AC withstand and partial discharge prior to leaving the factory.
Surgearrester
type
Nominal discharge
currentIn (kA)
Rated voltage
Ur(kV)
Max. continuousoperatingvoltageUc (kV)
Steep currentresidual
voltage @ 5 kA[1/20 µs] (kV)
Lightning currentresidual
voltage @ 5 kA[8/20 µs] (kV)
High currentimpulse
withstand(kA)
Dimensions(mm)
L1 L2
400PB-5SA-�5L400PB-5SA-�8L400PB-5SA-22L400PB-5SA-24L400PB-5SA-30L
400PB-�0SA-�5N400PB-�0SA-�8N400PB-�0SA-22N400PB-�0SA-24N400PB-�0SA-30N400PB-�0SA-36N400PB-�0SA-45N
55555�0�0�0�0�0�0�0
�5�8222430�5�82224303645
�2.0�4.4�7.6�9.224.0�2.0�4.0�7.6�9.224.028.836.0
42.452.765.770.087.346.256.068.974.492.7���.��38.2
40.048.059.064.080.040.248.659.864.580.496.4�20.0
6565656565�00�00�00�00�00�00�00
250250350350350250250350350350350450
290290390390390290290390390390390490
DesignSurge arrester comprising:�. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer moulded between the insert and the jacket.4. Contact rod.5. Earth lead.6. Earth connection.7. Steel cap.8. Metal oxide valve elements.9. Type C - 630 A interface as described by CENELEC EN 50�80 and 50�8�.
6
9
5
4
3
2
1
252 mm
L2L1
150 mm
Dia.80 mm
7
Dia.70 mm
8
�9
Typical application anddimensions
Ordering instructionsTo order the surge arrester, specify the surge arrester type, as described on previous page.
Example:For a maximum continuous operating voltage (rms) of 24 kV and a nominal discharge current of �0 kA.Order a 400PB-�0SA-24N surge arrester.
410 mm
220 mm 185 mm
Type 400PB-5SAor 400PB-10SAsurge arrester
Type 400TB/Gor K400TB/Gtee connector
355 mm
150 mm 202 mm
Type 400LBor K400LB
elbow connector
Type 400PB-5SAor 400PB-10SAsurge arrester
335 mm
150 mm 183 mm
Type 430TBor K430TBtee connector
Type 400PB-5SAor 400PB-10SAsurge arrester
20
0�/2
007
400TR and 400TR-LBINTERFACE C
TEST RODS
Application• The test rod can be used for: - cable fault location - cable testing - phasing checks, etc.• Connections may be made
with a cable lug, a 4 mm plug or spring clips.
InstallationThe test rod is mounted onto the clamping screw in the type C interface tee and coupling connectors. The test cable is connected to the threaded stem and the insulating shroud moved to its final position over the end of the test rod.
Design�. Insulating shroud.2. Threaded rod for test connection.3. Two nuts M�2.4. Insulation.5. Copper test rod stem.6. Wing nut.
An insulating shroud isprovided to allow theapplication of test voltageswhen bushings are closelyspaced.
Test rod type
Maximum A.C.test voltage
(50 Hz - 1 min.)
Maximum D.C.test voltage
(8 x U0 - 30 min.)
Impulse voltage (1.2 x 50 µs)
min.
400TR
400TR-LB
36 kV
36 kV
96 kV
96 kV
95 kV
95 kV
Technical characteristics • The 400TR test rod can
be used with 400TE, 430TB, 400TB and 440TB connectors.
• The 400TR-LB is for use with the 400LB connector.
480
4
5
2
288
40
1
3
M12
In mm.
400TR 400TR-LB
370
60
1
5
6
2
Dia.25
M10
4
Ordering instructionsSimply specify:400TR or 400TR-LB test rod.
22
0�/2
007
ACCESSORIESINTERFACE C
Up to 36 kVApplicationFor use with connectors and bushings with an interface C as described by CENELEC EN 50�80 and 50�8�.
Technical characteristics All these products, except theearthing plugs, are tested forAC withstand and partial discharge prior to leavingthe factory.
6/10 (12) kV6.35/11 (12) kV
8.7/15 (17.5) kV12/20 (24) kV
12.7/22 (24) kV18/30 (36) kV
400SOP-BStand-off plugIs designed to support and 'dead-end' connectors with a type C interface when removed from equipment.
Ordering instructionsOrder 400SOP-B for �2 kV,K400SOP-B for 24 kV orM400SOP-B for 36 kVapplications.
400GP-BEarthing plugIs designed to support and earth connectors with a type C interface when removed from equipment.
Ordering instructionsOrder 400GP-B for �2, 24 or 36 kV applications.
300GP-BEarthing plugIs designed to earth the 430TB-630A connectors when it is fixed-mounted to the equipment (maintenance earthing).
Ordering instructionsOrder 300GP-B for �2 or 24 kVapplications.
400DR-BDead-end receptacleFits over a bushing with a type C interface to provide 'dead-end' facility.
Ordering instructionsOrder 400DR-B for �2 kV,K400DR-B for 24 kV orM400DR-B for 36 kVapplications.The dead-end receptacle canbe supplied with an earth lead.Order: -/G.E.g. K400DR-B/G.
23
Kit MTEarthing kit for copper tape screened cablesContains a tinned copper braid (25 mm² - L = 500 mm), a tinned copper wire for cleating and some water sealing mastic.
Ordering instructionsOrder Kit MT for �2 kV, 24 kV 36 kV or 4�.5 kV applications.
440CPConnecting plugFor connecting two or more 440TB connectors, thus creating a separable cable joint or a multiple cable connection to equipment.For use up to �250 A.Only for use with 440TB.
400RTPAReducing tap plugProvides a type A interface to connectors with a type C interface.A 'C' spanner, 600SW, is used to tighten the reducing tap plug on to its mating part.
Ordering instructionsOrder 400RTPA for �2 kV or K400RTPA for 24 applications.Order 600SW for the 'C'spanner.
400CP-SCConnecting plugFor connecting two or more connectors with a type C interface together, thus creating a separable cable joint or a multiple cable connection to equipment.
Ordering instructionsOrder 400CP-SC for �2 kV, K400CP-SC for 24 kV orM400CP-SC for 36 kVapplications.
400BIPABasic insulating plugActs as a tightening nut for the 400TB and 440TB tee connector kits.The plug contains a voltage detection point.The conductive rubber protection cap is included.
Ordering instructionsOrder 400BIPA for �2 kV, K400BIPA for 24 kV orM400BIPA for 36 kVapplications.
Ordering instructionsOrder 440CP for �2 kV, K440CP for 24 kV orM440CP for 36 kVapplications.Order: -/ATEX for use in potentially explosive atmospheres (for �2 kV max.).
24
0�/2
007
POSSIBLE ARRANGEMENTSINTERFACE C
430TBSingle cable arrangement.Order 430TB for �2 kV or K430TB for 24 kV applications.
430TB+300PBDual cable arrangement.Order 430TB+300PB for �2 kV or K430TB+K300PB for 24 kV applications.
400TB/GSingle cable arrangement.Order 400TB/G for �2 kV, K400TB/G for 24 kV,M400TB/G for 36 kV or P400TB/G for 4�.5 kV applications.
In mm.
183
110
teeconnector
basicinsulatingplug
250
110
teeconnector
basicinsulatingplug
290
110 105
teeconnector
couplingconnector
basicinsulatingplug
400TB/G-P2Dual cable arrangement.Order 400TB/G-P2 for �2 kV, K400TB/G-P2 for 24 kV or M400TB/G-P2 for 36 kV applications.
connectingplug
500
110 245
basicinsulating
plug
25
In mm.
400TB/G-L4Disconnectable tap-off.Order 400TB/G-L4 for �2 kV, K400TB/G-L4 for 24 kV or M400TB/G-L4 for 36 kV applications.
1020
basicinsulating
plug
connectingplug
connectingplugs
basicinsulating
plug
400TB/G-L22-way connection.Order 400TB/G-L2 for �2 kV, K400TB/G-L2 for 24 kV or M400TB/G-L2 for 36 kV applications.
400TB/G-L52-way connection with tap-off.Order 400TB/G-L5 for �2 kV or K400TB/G-L5 for 24 kV applications.
connecting plug
530
basicinsulating
plug
basicinsulating
plug
505
type Aseparableconnector
reducingtap plugbasic
insulatingplug
400TB/G-L33-way connection.Order 400TB/G-L3 for �2 kV, K400TB/G-L3 for 24 kV or M400TB/G-L3 for 36 kV applications.
775
basicinsulating
plug
basicinsulating
plug
connectingplug
connectingplug
26
Connector on earthing plugOrder 400GP-B for �2 kV, 24 kV and 36 kV applications.
earthingplug
basicinsulating
plug
Earthing plug on connectorOrder 300GP-B for �2 kV and24 kV applications.
430TB teeconnector
300GPB earthing plug
Connector on stand-off plugOrder 400SOP-B for �2 kV, K400SOP-B for 24 kV or M400SOP-B for 36 kV applications.
stand-offplug
basicinsulating
plug
27
In mm.
110
600
insulatingshroud
400TRtest rod
400TB or 440TBtee connector
110
430TB teeconnector
600
insulatingshroud
400TRtest rod
Cable and equipment testing.
125
400LB elbowconnector
515
insulatingshroud
400TR-LBtest rod
Additional catalogue information on power cable accessoriesis available by contacting us at the address below:
Nexans Network Solutions N.V. - Div. Euromold • Zuid III, Industrielaan �2, B-9320 ErembodegemTel.: +32 (0)53 85 02 �� • Fax: +32 (0)53 83 �0 �3 • www.nexans.com • [email protected]
Catalogue also available on CD-ROM
Distributed by:
0�/2
007