A common wall between the zones
Zone 1 with four walls and four windows
Zone 2 with four walls and four windows
An example of a model with two zones
This is the ORIGINAL wall BLOCK
The common wall between the zones is constructed from an ordinary ’wall block’. Take an ordinary wall block from the library and look behind the block mask – see the
example below
The block should be replaced by one of this kind
NEW BLOCK – a common wall between two zones
INTERIOR WALL CLADDING 1 replaces EXTERIOR WALL CLADDING
Inputs Zone 1 and Radiation 1 replace Geometry
NEW BLOCK
INTERIOR WALL CLADDING 1 is a copy of INTERIOR WALL CLADDING 2, with one new output – Last node.
New Construction output
Last node.
CHANGES IN THE MAIN BLOCK MASK
CHANGES IN THE MAIN BLOCK MASK
Define material 1 in the block mask of INTERIOR WALL CLADDING 1
Go one level below and define surface transfer coefficients alfacin1 and betaPin1 in the block mask of Internal surface node /CTH. Check the names of the parameters with the ones specified in the main block mask (see slide 6)
Do the same for the block INTERIOR WALL CLADDING 2 / Internal surface node /CTH.
Check the names of the parameters with the ones specified in the main block mask (see slide 6)