BLAST ALL Inc. Industrial Coating • Structural Maintenance • Abrasive Blasting
14
8 M
ill R
ock
Ro
ad E
ast
•
P.O
. Bo
x 7
75
•
O
ld S
ayb
roo
k, C
T 0
64
75
•
Te
l (8
60
) 3
88
-54
64
/ F
ax (
86
0)
38
8-4
64
4
Equal Opportunity Employer
TOWN OF LEE, EMERGENCY REPAIR OF BRIDGE L-05-044 VARIOUS LOCATIONS, 607545-92992
961.67: Containment
• Methods and equipment to be used for precleaning (washing) and surface preparation
- See attached HSP pressure washer for precleaning. • Location of equipment and impact on traffic
- See attached Drawing Sheet 5 of 12 for equipment location • Engineering Calculations: Load-bearing capacity, Wind load and Ventilation
- Containment system shall be a suspended platform constructed by a pre-engineered scaffolding system. See attached ventilation calculations.
• Connection Details - Reference Engineering Drawing # S – 4 & 5.
• Lighting Plan and Placement - Explosion Proof Lighting shall be utilized, hand held, head mounted see attached data
sheets. Also abrasive blasting hose are fixed with lights. See attached data sheet. 30 ft Candles shall be maintained at steel surfaces during inspections.
• Drawings and Plans for installing, moving, and removing the containment. - See attached drawings of the platform system BAI intends to utilize.
• Provisions for Emergency breakdown of containment. - Containment will be disassembled at a moment’s notice by unclamping tarping and securing
in a safe location. 30 mins or less start to finish. • Provisions for moving the containment out of navigation lanes when working over active waterways.
- NA • Provisions for the containment of debris that might escape when working over land, streams, rivers, lakes, or other bodies of water.
- Per SSPC Method 22 • Descriptions and product data or cut sheets for all containment system materials and all equipment to be used
- See attached • Confirmation that appropriate notification and coordination with other organizations or agencies such as the Coast Guard and Railroad have been accomplished with regard to right of ways, containment clearances, and other project restrictions.
- Per prime contractor’s notifications.
BLAST ALL Inc. Industrial Coating • Structural Maintenance • Abrasive Blasting
14
8 M
ill R
ock
Ro
ad E
ast
•
P.O
. Bo
x 7
75
•
O
ld S
ayb
roo
k, C
T 0
64
75
•
Te
l (8
60
) 3
88
-54
64
/ F
ax (
86
0)
38
8-4
64
4
Equal Opportunity Employer
TOWN OF LEE, EMERGENCY REPAIR OF BRIDGE L-05-044 VARIOUS LOCATIONS, 607545-92992
961.67 Confirmation and Notification with Organizations
Appropriate notifications and coordination has been made with personnel within the town of Freetown. They are aware of the scope of construction operation to take place on site and how that will impact their daily activities with regards to clearances, right of ways and restrictions.
BLAST ALL Inc. Industrial Coating • Structural Maintenance • Abrasive Blasting
40 ≤ 400 OK
Quantity1
OK
Q (cfm) DV (fpm) IA (ft²)4000 600 7
DA= ᴫr² 0.785 ft²
Q= 4000 V=Q/DA 50964,000 ≤ 5096 OK
Min
imum
Ve
ntila
tions
Re
quire
d
Vent
ilatio
n Pr
ovid
ed
Design Parameters Suspended PlatformLength, L (ft) 102
Area, A (ft²) = W x H 40
SSPC Guide 6 - Class 1A Cross Draft CalculationVelocity, V (ft/min) = 100
Q = V x A (cfm) Q = V x AVolume Required, Q (cfm)
Containment Design Schedule
Width, W (ft) 8Height, H (ft) 5
4000Dust Collector Model
P20 Dust Collector
Air I
nlet
Des
ign
All air inlets and access openings shall be baffled or so arranged that by the combination of inward air flow and baffling the escape of abrasive or dust particles
into an adjacent area will be minimized and visible spurts of dust will not be observed.
Dim
ensio
ns (f
t)
Maximum Cross Per Spec = 400 SF
148
Mill
Roc
k Ro
ad E
ast
•
P.O
. Box
775
•
Old
Say
broo
k, C
T 06
475
•
Tel (
860)
388
-546
4 /
Fax
(860
) 388
-464
4
20,000 ≥ 4,00020,000
Design Velocity, DV (fpm)
Max Inlet Area, IA = Q/V
Provide Maximum of 7 SF of inlet area. Inlet area may need to be reduced for field conditions to maintain negative air within containment enclosure.
600
Total Ventilation Provided (cfm)Total Provided ≥ Required
Volume, Q (cfm)20,000
V MIN = 4,000 Ft/Min12
1
Exha
ust D
ucts
Ducting Exhaust Velocity CriteriaDucting Diameter (inches)
Single Duct Area (DA)No. of Ducts Provided
Exhaust Velosity at Ducts (Ft/Min)Design Check
Entrance/Exit
*see footnote1
Air lock Area
Entrance/Exit
*see footnote 1
Footnotes
1. May be doors or
overlapping tarps.
2. Not drawn to scale.
Page: 1
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
Explosion Proof LED Flashlight - 4 Watt - Push Button Switch - MADE IN THE USAPart #: EXP-LED-F4W
Buy American Made
The Larson Electronics EXP-LED-F4W intrinsically safe LED flashlight has a 4 watt LED that produces a very tight, well focused pencil
beam of light. Unlike many LED flashlights which produce a wide beam spread, this unit produces a tight round spot beam with clearly
defined edges, giving it excellent range and intensity. The specially designed grip pattern provides secure handling, even in wet, oily
and slippery conditions. Weatherproof and intrinsically safe, this light produces a light beam that at 100 feet has a spread of only 9
feet.
This LED flashlight features a deep dish reflector that focuses the light from the high output LED into a tight round beam. An ergonomic tactical
design adds great versatility and durability, allowing this light to be used in industrial or professional applications with equal effectiveness. A
rubber push button switch provides easy operation while a knurled body design allows for maximum grip and control. Constructed of highly
durable nylon, this unit is watertight and able to withstand the rigors of aggressive and heavy duty use and applications. Power for this light is
provided by 3 AA-cell alkaline batteries which give this unit a runtime of 80 hrs. The high intensity LED in this light produces 90 lumens, almost 3
times that of halogen incandescent D cell flashlights, and has a lifetime of 30,000 hours, compared to the 50 hour average for an incandescent
flashlight bulb.
This Led flashlight was tested by W. Thomas Smith on a 36 hour outing with the U.S. Counterterrorism Advisory Team. The results of this field
testing led Mr. Thomas to call this LED flashlight: “perhaps the most-superbly designed flashlight I’ve ever owned, certainly the best all-weather,
weapons-mountable, waterproof, explosion-proof, reasonably priced .... hard-plastic flashlight I’ve ever tested.” You can view Mr. Thomas’ review
here.
Page: 2
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
The EXP-LED-F4W LED beam is intense, high
quality, and tight even when hitting the back
wall of this 40' container.
This particular snapshot shows the comparable
Larson Electronics LE-224 Halogen flashlight.
Notice the halogen is less bright and more
yellowish.
Illumination of the EXP-LED-F4W at 225 feet.
This LED flashlight meets the highest safety
ratings for hazardous locations at a price below
$50. However, this flashlight still delivers a
strong beam to 250 feet.
Click Photo to Enlarge Click Photo to Enlarge Click Photo to Enlarge
Click Photo to Enlarge Click Photo to Enlarge Click Photo to Enlarge
Page: 3
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
Part #: EXP-LED-F4W (1649)
Specifications / Additional Information
EXP-LED-F4W Approvals
Lamp Type: LED Intrinsically Safe - Zone Zero Rating
Dimensions: 7.125 "-L 1.75 "-W 2"-H ATEX II1GD Exia IIC T4 iaD T135C
Watts: 4 Class 1, Division 1 Groups A,B,C,D
LED Life Expectancy: 30,000 hours Class II, Division 1 Groups E,F,G
Lumens: 90 T4 temperature rating
Lighting Configuration: Spot
Materials: Nylon Housing Watertight
Weight: 7 oz. Hazardous Location Classifications
LUX: At 10 ft: 599
LUX: At the lens: 145,400 Special Orders- Requirements
Burn Time: 80 hrs Contact us for special requirements
Toll Free: 1-800-369-6671
Intl: 1-903-498-3363
E-mail: [email protected]
Same Day Shipping Available!! Scroll Down to Purchase-
Page: 1
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
Explosion Proof Dual Function Headlight- Class 1 Division 1 Headlamp - High/Low Spot BeamsPart #: EXP-LED-HL-DFX
Page: 2
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
Buy American Compliant
The EXP-LED-HL-DFX Explosion Proof Dual Function Headlight is ideal for a wide variety of uses including Industrial Safety, Public
Works & Utilities, Law Enforcement, Hardware/Tool, Automotive, Marine, Sporting Goods and Consumer applications. A single high
intensity Luxeon LED emitter mounted within a lightweight housing provides up to 13.5 hours of useable light and can be either worn
on the head or attached to a hard hat with the included elastic or rubber straps.
The EXP-LED-HL-DFX explosion proof dual function LED headlight from Larson Electronics produces an intense light beam while providing up to
13.5 hours of illumination. A single CREE® high intensity LED mounted within an impact resistant housing is powered by 3 AAA batteries to
produce a long lived spot beam of up to 120 lumens in high mode and 70 lumens in low mode. Included with this explosion proof headlight are an
elastic headstrap and a rubber hard hat strap to allow users to either wear the unit directly or mount it to their hard hats for ease of operation.
Click to Enlarge Click to Enlarge
Featuring a housing constructed of impact resistant engineering resin that has been drop test verified, an unbreakable polycarbonate lens, and a
single CREE® high intensity LED rated at 50,000 hours of operating life, this headlight provides users with a highly convenient and safe light
source that leaves their hands free for work operations. Rubber O-ring sealed and weather resistant, this headlight has a rubber dome push
button switch that allows easy operation even when wearing gloves.
ETL Listed intrinsically safe for use in Class I, Division 1 and 2, Groups A, B, C, D, Class II, Divisions 1 and 2, Groups E, F, G, and Class III
Temperature Code: T3, this light safe for use in environments containing gases, vapors and various dusts. This unit will operate for up to 13.5
hours on a fresh set of AAA batteries.
Page: 3
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
Part #: EXP-LED-HL-DFX (68715)
Specifications / Additional Information
EXP-LED-HL-DFX Dual Function LED Headlight ETL Listed
Lamp Type: CREE® LED Class 1, Division 1 & 2, Groups A, B, C, D
Dimensions: 2.4"-W x 1.9"-H x 1.8"-D Class 2 Division 1 & 2, Groups E, F, G
Weight: 3.5oz Class III Temperature Code: T3
Mounting: Elastic Head strap or Rubber Hard Hat Strap Class 1 Zone 0
Lumens: 120 Intrinsically Safe
Runtime: 13.5 Hours (low), 4.5 Hours (high) ETL Listed United Stated & Canada
LED Life Expectancy: 50,000+ hours AEx ia IIIC T 165C Da
Materials: Impact Resistant Resin Housing, Polycarbonate Lens Ex ai IIC T3 GA, Zone 20
Power: BATTERY: Three (3) “AAA” size alkaline cells Explosion Proof Light Design Description
Light Temperature Rating Table
Hazardous Location Classifications
Special Orders- Requirements
Contact us for special requirements
Toll Free: 1-800-369-6671
Intl: 1-903-498-3363
E-mail: [email protected]
CE Certified
Limited Lifetime warranty .
Scroll Down to Purchase-
Page: 4
Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 Phone: 903.498.3363 Fax: 903.498.3364 Email: [email protected]
Links (Click on the below items to view):
- Manual
- Hi-Res Image 1 -
- Hi-Res Image 2 -
BLAST ALL Inc. Industrial Coating • Structural Maintenance • Abrasive Blasting
14
8 M
ill R
ock
Ro
ad E
ast
•
P.O
. Bo
x 7
75
•
O
ld S
ayb
roo
k, C
T 0
64
75
•
Te
l (8
60
) 3
88
-54
64
/ F
ax (
86
0)
38
8-4
64
4
Equal Opportunity Employer
HEATING PROCEDURES
In reference to the use of heat for coating application purposes during low temperatures, Blast All Inc. proposes to use Frost Fighter indirect fired space heaters to provide required temperature conditions per coating manufacturer’s specifications.
Indirect heating units will be connected to existing containment. Units will be placed in a secure location and will channel heated air into the containment during operations. Additionally, each indirect heating unit will be accompanied by a fire extinguisher and shall be kept away from obstructions and flammable materials. Operation of indirect heating units will strictly abide to the operator’s manual and recommendations.
Personnel will monitor heating units during work operations to ensure safety and effectiveness.
Please reference data sheets for equipment specifications.
If there any questions regarding this matter or if further information is required, please contact our main office.
IDF 200, 350 & IDF 500Features:
• ConstruCtion
• industry
• Mining
• AviAtion
• AgriCulture
• MilitAry
•Stainlesssteelheatexchanger•Easyballvalveswitchoverfrompropanetonaturalgas•InternationalETLapproval•Highefficiencyburner&heatexchanger
•Quietoperation•Easymobility-16"wheels•Fullyinsulatedforincreasedefficiency•Liftingbracketwithboltpackage
PORTABLE HEATERSPORTABLE HEATERS
1500NotreDameWinnipeg,MBR3E0P9ToLLFREE:18887920374DIREcT:(204)7758252Fax:(204)7836794WEB:www.frost-fighter.comcoRPoRaTE:www.ice-ww.com
temporary Heating equipment since 1965
Clean, safe, economical, High Capacity Heating anywhere you want it!• Clean burning flame retention
burner.• vented burning for safe use
in confined areas.• independent fan and combustion
air feeds ensure quick winter starts. no heated air led off for combustion or lost up the flue.
• service is a breeze.• Fast parts supply.
Unlikeadirect-firedheater,theFrostFighterprovidescleanair,freefrommoistureandcontaminatedfumes.
Quickconnectductsattachtothefrontcapoutletsandenabletheusertodisbursetheheatedairoveralargearea,withanoptionalremotethermostatcontrolformaintainingdesiredtemperaturelevels.
TheFrostFighterisportableandsimpletooperate–allpartshaveeasyaccessforquickserviceandroutinemaintenance.
Withover35yearsofprovenreliabilityandruggeddurabilityeveninextremeclimates,theFrostFightercontinuestobealeaderfortemporaryheatingneeds.
*No.1fueloilorkeroseneisrecommendedwhentheambienttemperatureislessthan8ºF(-10ºc)Dischargetemperature(@50ºFambient).Specificationsaresubjecttochangewithoutpriornotice.
idF 350-11 oil idF 500 oil idF 350 lP/ng idF 500 lP/ng
coDENUMBER 47003 47004 47005 47006
MaxcaPacITy 320,000BTUs 500,000BTUs 350,000BTUs 420,000BTUs
HEaTEDaIR(W/oUTDUcT) 2,800cFM 3,100cFM 2,800cFM 3,100cFM
DIScHaRgETEMP.200ºFwithductcreating0.4"staticpressure
180ºFwithductcreating0.5"staticpressure
220ºFwithductcreating0.4"staticpressure
220ºFwithductcreating0.5"staticpressure
FUEL Fueloil* Fueloil*Propane/Naturalgas
Propane/Naturalgas
TaNkcaPacITy
35Imperial–approx.40U.S.gallons(18Hours)
35Imperial–approx40U.S.gallons(14Hours)
- -
NozzLESIzE/PRESSURE2.0U.S.gPH@125psi
2.5U.S.gPH@145psi
LP/Ng-1.8"w.c. LP/Ng-2.8"w.c.
BURNERMoToR(115V,60cycLE)
1/3HP,3450RPM
1/3HP,3450RPM
1/3HP,3450RPM
1/3HP,3450RPM
NETWEIgHT(aPPRox.) 520lbs 520lbs 520lbs 520lbs
SHIPPINgWEIgHT(aPPRox.) 570lbs 570lbs 550lbs 550lbs
FINISH Powdercoat Powdercoat Powdercoat Powdercoat
aIRoUTLETS-oPTIoNaLoNE16"DIaMETER
Standard-Two12"diameter
Standard-Two12"diameter
Standard-Two12"diameter
Standard-Two12"diameter
DIMENSIoNScRaTED(LxWxH)
70"x35"x50"83"x37"x52"
70"x35"x50"83"x37"x52"
70"x36"x50"83"x37"x52"
70"x36"x50"83"x37"x52"
aPPRoVaL cSa cSa ETL ETL
yourdealer/distributoris:
LP/NgFeatures: •Quickballchangevalvechangeoverfrompropanetonaturalgas •3trialsforignition
oILFeatures: •Polytankwithguage&environmentalspillcontainment
Meets osHA standardsspecifications