© 2004 Eaton Corporation. All rights reserved.
Powerware 9390 Parallel Applications
Agenda
Paralleling the Powerware 9390 wayDifferences from other Powerware productsHow it worksPowerware 9390 paralleling requirementsOperation and controlKey selling features
Paralleling the 9390 Way
HotSync ® paralleling technologyUp to eight (8) modules can be paralleled for capacity or redundancyUp to four (4) modules can be paralleled without a central bypassFour-module system can be ordered for full capacity or redundancy (4 x 80 kVA UPMs / 320 kVA)All parallel systems need a tie pointCAN Bus communication“Pull chain” back-up control
9390 Paralleling: Key Differences
Common battery not currently supportedNo central bypass needed for four (4) modules or lessNo intelligence in tie cabinet for four (4) modules or lessTie cabinet is breaker based with options for a main output breaker, central maintenance bypass and kirk key interlocks Tie cabinets with “system” bypass available with “OK to Bypass” indicator lampNo individual lamps for each UPS disconnect Currently no UPS with IDC 480/208 paralleling
How it Works
Patented HotSync TM Paralleling technologyEach unit is a “peer”, no master/slave relationships Modules synchronize with bypass sourceCAN bus sends unit information between systemsThe “pull chain” ensures bypass control even if the CAN bus is lostFirmware code is very close to Powerware 9330 parallel code, except no central bypass requirement for less than four (4) units
9390 Paralleling Requirements
9390 Paralleling Requirements
Parallel cardIn each UPM
9390 Paralleling Requirements
CAN Bus wiring between UPMs
“Pull chain” wirebetween units
System Operation
If total system is redundant (N+1), failure of any one system does not affect critical bus
Protected AC from inverters
System Operation
If system is full capacity, failure of any one system forces all units to static bypass
AC through static bypass
System Controls
System Functionality
System-levelcontrol
Individual Unit Functionality
Each unit can be shut down individually for maintenance
Unit Display
System View
Total system meters or any individual unit can be displayed from the front panel of any UPM
Total System Display
Individual System Display
Installation Rule
UPM 2
Battery
Bypass inputs to UPMs
UPM 1
Battery
UPM 3
Battery
UPM 4
Battery
Outputs from UPMs
1A
2A
3A
4A
1B
2B
3B
4B
(Total length of 1A + 1B) ≅
(Total length of 2A + 2B) ≅
(Total length of 3A + 3B) ≅
(Total length of 4A + 4B)
Maximum variance of combined input and output
wire lengths = 10%
This is a requirement to ensure approximately equal current
sharing when in static bypass mode.
Main output Breaker(MOB Optional)
UPS module outputBreakers
(Maintenance disconnects)Bypass Breaker(MBP optional)
9390 Module tie cabinet (non-matching)
Chris Loeffler
6/2/2004
Updated 9/17/2004
SIZE FSCM NO DWG NO REV
A 9390INST-0105 P5
SCALE NS SHEET 1 OF 1
*
K1
K5
9390 UPS
K3
E6 / E7 / E8E1 / E2 / E3
E4 / E
5
Single feedjumper
(remove fordual feed)
E9/ E
10/ E11
D
BA
* *
K1
K5
9390 UPS
K3
E6 / E7 / E8E1 / E2 / E3
E4 / E
5
Single feedjumper
(remove fordual feed)
E9/ E
10/ E11
D
BA
* *
K1
K5
9390 UPS
K3
E6 / E7 / E8E1 / E2 / E3
E4 / E
5
Single feedjumper
(remove fordual feed)
E9/ E
10/ E11
D
BA
* *
K1
K5
9390 UPS
K3
E6 / E7 / E8E1 / E2 / E3
E4 / E
5
Single feedjumper
(remove fordual feed)
E9/ E
10/ E11
D
BA
*
9390 Module Tie Cabinet
A
BC
System Output
Bypass Input
Rectifier Input(For dual feedapplications)
Optional Bypass Input(Same source as UPS
bypass inputs)
Provided by othersOver current Protection
Provided by others*
9390 Module tie cabinet (non-matching)
6/2/2004
Chris LoefflerSIZE FSCM NO DWG NO REV
A P5
SCALE N/S SHEET 1 OF 1
9390INST-0105
9390 Module Tie Cabinet
Main output Breaker(MOB optional)
UPM output Breakers
Bypass Breaker(MBP optional)
System Output
"Solenoid Key Unit"
KR
Optional
9390 UPM #1 9390 UPM #2 9390 UPM #3 9390 UPM #4
Bui
ldin
g A
larm
#1
Bui
ldin
g A
larm
#1
Bui
ldin
g A
larm
#1
Bui
ldin
g A
larm
#1
Bui
ldin
g A
larm
#2
Sta
tic B
ypas
sR
edun
dant
Lin
k
Bui
ldin
g A
larm
#2
Sta
tic B
ypas
sR
edun
dant
Lin
k
Bui
ldin
g A
larm
#2
Sta
tic B
ypas
sR
edun
dant
Lin
k
Bui
ldin
g A
larm
#2
Sta
tic B
ypas
sR
edun
dant
Lin
k
X-Slot Card(Parallel Card)
CAN Bus
OK to close MBP Relay
Building alarm2 replacement
X-Slot Card(Parallel Card)
CAN Bus
OK to close MBP Relay
Building alarm2 replacement
X-Slot Card(Parallel Card)
CAN Bus
OK to close MBP Relay
Building alarm2 replacement
X-Slot Card(Parallel Card)
CAN Bus
OK to close MBP Relay
Building alarm2 replacement
Parallel installation could use up to 3 building alarms. If customer requires extra’s order CEO option.
Things to Remember
• Parallel installation can use up to three (3) building alarms; order Communication Expansion option if customer requires extra alarm inputs
• Each unit comes with a Web/SNMP card and EMP, so there are two (2) building inputs available for use with each EM; these alarm inputs only work with Powerware monitoring/management software, (LanSafe, PowerVision)
Preferred software application is new release of PowerVision, which will be released later this year (mid 4th qtr); PowerVisioncan monitor all UPS power modules as a system and coordinate server shutdown
CTO ConfigurationsDigit
1 2 3 & 4 5 6 7 8 9 10 11 12 13 14 15
9390 Family
Parallel Tie
Cabinet UPS Rating
Number of UPS Modules
(UPMs)Cabinet
ConfigurationVoltage Rating
Breaker kAIC Ratings
Main Output Breaker (MOB)
selection
Maintenance Bypass Breaker
(MBP) selection* Transformer
Options (Future) Options Language
Matching design
T P 03=30kVA 1 = Not used 1 = N+1 0 = Not Used 1 = 35kAIC 0 = No 0 = No 0 = None 0 = None 0 = Aux 2A/2B 1 = English 0 = No
04=40kVA 2 = 2 2 = Capacity 1 = 208V 2 = 65kAIC 1 = Yes 1 = Yes 1 = K4
1 = Aux 2A/2B and Shunt trips 2 = French 1 = Yes
05=50kVA 3 = 3 2 = 480V 3 = 100kAIC 2 = K13
2 = 2A/2B, & lamp "OK to Bypass" 3 = German
06=60kVA 4 = 4 3 = 400V 3 = K20
3 = 2A/2B, Shunt trips & lamp "OK to Bypass" 4 = Italian
08=80kVA 4 = Not used
4 = 2A/2B & Solenoid with KK locks 5 = Spanish
10=100kVA 5 = 480/208V
5 = 2A/2B, Shunt trips & Solenoid with KK locks 6 = Japanese
12=120kVA 7 = Mandarin16=160kVA 8 = Russian
* Requires Main Output Device (MOB)Shunt trips 120VAC
Possible future requirements
9390 Parallel Configure to Order (CTO) Chart
Key Selling FeaturesPatented HotSync ® Paralleling technology
Field-proven through thousands of customer installations
Scalability for future growth capabilityNo need for customer to buy excess capacity today
Redundancy with capability to expand capacityCustomers requiring redundancy can now increase the load by adding more UPS power modules to keep the redundancy (previously only available above 200 kVA or below 40 kVA )
Service support from the best in the industry