AMINE GUARDTM FS PROCESS
GAS PROCESSING
Amine Guard FS process technology combines the highperformance, formulated, UCARSOL® family of sol-vents with the reliable Amine Guard system processtechnology. The thermally regenerated and/or flash-regenerated solvent process removes CO2, H2S andother sulfur components.
Hydrocarbon, H2 and CO losses are minimal in theAmine Guard FS process due to their low solubility in the UCARSOL solvent. The process is capable ofachieving very low product gas specifications, to 1 ppmv of H2S and 50 ppmv of CO2. There are alsoenergy efficient process optimizations available, such asa flash-regenerated flowscheme for bulk CO2 removal.
APPLICATIONS
The Amine Guard FS process can be tailored for eitherbulk, selective, or trace acid gas removal for CO2 andH2S. It is typically used in:
� Synthesis gas treating for CO2 removal in syn-thesis gas plants, such as direct iron ore reduction
� Synthesis gas treating for selective H2S removalin integrated gasification combined cycle(IGCC) plants
� Natural gas treating for selective removal of H2Sand partial removal of CO2 for pipeline specifi-cations
� High CO2 partial pressure service for reducedenergy consumption compared with conventionalamines, such as steamed reformed ammoniaplants.
Design packages ranging from functional process speci-fications through a complete UOP Schedule A areoffered to support this technology. As with all ourprocesses, service is always readily available throughUOP’s worldwide technical service organization.
FEEDSTOCK AND PRODUCTS
Acid gas partial pressure is the key driving force for theAmine Guard FS process. Typical feed conditions rangebetween 150 and 1800 psia total pressure, with acid gascompositions from 5% to 35% by volume. The productspecifications achievable depend on the application andcan be anywhere from ppmv levels of acid gas to a fewpercent of CO2.
EXPERIENCE
The Amine Guard FS technology was introduced 19years ago. As of January, 2000, over 400 units havebeen put into commercial service.
FOR MORE INFORMATION
For more information, contact your local UOP sales officeor UOP’s Gas Processing business in the USA at:
Phone: (713) 744-2860Fax: (713) 744-2802E-mail: [email protected]
UCARSOL® is a registered trademark of Union Carbide Corporation.
©2000 UOP LLC. All rights reservedThis information is not to be taken as a warranty or representation for which UOPassumes legal responsibility nor as permission or recommendation to practice anypatented invention without a license. It is offered solely for your consideration.
UOP 3205-899GP1A
uopTM
UOP LLC25 East Algonquin RoadDes Plaines, IL 60017-5017
Absorber
Stripper
Treated Gas
FlashDrum
Lean/RichExchanger
UntreatedFeed
Acid Gas
CondenserReflux Drum Lean
Cooler
RichGas
RefluxPump
Amine Guard FS ProcessLow Energy CO2 Removal
Make-UpWater
LeanSolutionCooler
AmineAbsorber
AmineStripper
RefluxPump
Acid GasKnock-Out
Drum
Acid GasAcid GasCoolerAcid Gas
Lean SolutionPump
Lean/RichExchanger
AmineReboiler
FeedGas
Amine Guard FS ProcessSelective H2S