Upload
andik-manchesterunited
View
45
Download
3
Embed Size (px)
DESCRIPTION
NOKI
Citation preview
NOKIA BSC3i (BSCC, BSCD) Commands
For all Modules status/Names
ZUSI: COMP; enter GSM.EXGA (TRX) ERGA (Duplexer) DCS..EXDA (TRX) ERDA (Duplexer)For any site status
ZEEI; Enter
For any particular (BCSU card) BSC Card status
ZUSC: BCSU, 0 enter
For any BSC Card change state or replacement of Card, for example BCSU Card
Extraction or Lock of card/Enable or Disable of Card
From working to Disable
ZUSC: BCSU, 1: WO Enter (working)ZUSC: BCSU, 1: SP Enter (spare)ZUSC: BCSU, 1: TE Enter (Test)ZUSC: BCSU, 1: SE Enter (separate, out of service)ZUSC: BCSU, 1: SE Enter (No Hardware)
From Disable to Working
Will apply in reverse order the above commands
ZUSC: BCSU, 1: SE Enter (No Hardware)ZUSC: BCSU, 1: SE Enter (separate, out of service)ZUSC: BCSU, 1: TE Enter (Test)ZUDU: BCSU, 1ZUDH: BCSU, 1; FOR DIAGNOSTICZUDQ; FOR STATUS CHECK either diagnostic run r not, in case of run there would be unit okZUSC: BCSU, 1: SP Enter (spare)ZUSC: BCSU, 1: WO Enter (working)
For Clock status (Two clocks Internal & External)
ZDRI; OR DRI; Enter
For site Lock unlock
ZEFS: 15: U; (for lock L)
For particular site status with certain BCF
ZEEI: BCF=15;
ZEOL:: NR=7706; [ TO CHECK CURRENT SITE DOWN ALARMS]
ZEOL::NR=7995; [ TO CHECK CURRENT INTELLIGENT SHUTDOWN ALARMS]
ZEOL::NR=7704; [ TO CHECK CURRENT ET DOWN ALARMS]
ZEOL::NR=7767; [ TO CHECK CURRENT SECTOR DOWN ALARMS]
ZUSI:TCSM; [ TO CHECK ATER STATUS]
ZNET; [TO CHECK BSC SS7 LINKS STATUS]
ZEEL; [TO CHECK BSC TRAFFIC]
To find BCF of any site
ZEEI: SEGNAME: MAA0011; (any sector number);
For Site Alarms Status
ZEOL: BCF; ENTER
ET Loop Test
ZYEF: ET, 86;
ISD Feature implemented on site or not
ZEFO: (BCF) 92;
ISD Implementation Procedure
1-Polarity change command
ZEFX: 92: INBR=3: POL=OPEN;
FOR Closed
ZEFX: 92: INBR=3: POL=CLOSED;
2-Rout Change command
ZEFX: BCF# (ONLY NO):INBR=3: ROU=MAINS;
3. For Battery Backup Timer
ZEFM:16:BBU=NONE;
4. For Non BCCH Shut Down Command
ZEFM: BCF#NTIM=10;
5. For BCCH Shut Down Command
ZEFM: BCF#BTIM=25;
For Polarity check of any alarm
ZEFX: 16: INBR=3: POL=;
To Disable the ISD on a Specific Site.
1. ZEFX:19:INBR=3:ROU=ACT;
2. ZEFM:16:BBU=ALL;
3. ZEFM: BCF#NTIM=0;
4. ZEFM: BCF#BTIM=0;