7/30/2019 900 Series Ins
1/23
Model: 9008 / 9008S / 9012
9013 / 9040ImportantPlease check your model against theamendments at the back of this booklet before aempng
Installaon
Assembly & Fing Instrucons
For the latest fing instrucons please visitwww.insigniarange.co.uk
Contents
Introducon 3
Electrical Requirements 5
Tools Required 6
Whats in the boxes 7
Staring the Installaon 11
Connecng The Shower Accessories 23
Electric Connecons 26
Water Connecons 27
Product Tesng 33
Tesng for Leaks 38
Safety 39
Warranty Informaon 40
Spare Part 41
Troubleshoong, Help & FAQs 42
AmendmentsImportant 43
7/30/2019 900 Series Ins
2/23
For the latest fing instrucons please visitwww.insigniarange.co.uk
ASSEMBLY AND SIMPLE PLUMBING
THIS PRODUCT BUILD IS RATED SUITABLE FOR DIY PURPOSESPROVIDING THE CUSTOMER IS OF ABOVE AVERAGE SKILLS AND
FEELS CONFIDENT IN THEIR ABILTY. ONLY YOU THE CUSTOMER
WILL KNOW THIS SO BEFORE ANY ATTEMPT IS MADE TO ASSEMBLY
READ THROUGH THE FOLLOWING PAGES IN DETAIL THEN DECIDE.
IF YOU HAVE ANY DOUBT USE THE SERVICES OF A PROFESSIONAL.
IN PICKING SUCH, ALLOW THEM TO DECIDE IF THEY ARE CAPABLE
OF BUILD BY FIRST SHOWING THESE INSTRUCTIONS TO THEM. AL-
WAYS GET THREE QUOTES.
REMEMBER THE BEST IS NOT ALWAYS THE CHEAPEST!
REMEMBER PLUMBERS PLUMB! 90% OF THIS JOB IS NOT
PLUMBING!
ELECTRICAL CONNECTION TO HOUSE MAINS
WHEN YOUR ITEM IS ASSEMBLED ALWAYS USE THE SERVICES OF AFULLY QUALIFIED ELECTRICAL COMPANY TO COMPLETE CONNEC-
TION FROM SHOWER TO HOUSE SUPPLY. LAWS DEMAND IN MANY
CASES YOU DO THIS AND YOUR WARRANTY IS VOID REGARDS
ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN.
YOURS AND OTHERS SAFETY IS PARAMOUNT. NEVER ATTEMPT
THIS YOURSELF.
DUE TO THE NATURE OF THIS PRODUCT WE HIGHLY ADVISE THE
PURCHASE AND FITTING OF A WATER SOFTENER
For the latest fing instrucons please visitwww.insigniarange.co.uk
Thank you for your recent purchase of an Insignia steam shower.
Please read this booklet with great care to ensure you get the
best out of your build and have a shower that will last for manyyears to come!
Like everything, in order to obtain a first class product that will
serve you well for many years, the effort and correctness put into
the assembly will reflect in the quality of your finish. First remem-
ber what you need from your new item then remember this as
you build. The result will only be as good as the assembly!
OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY
BASED ON
CLIENT FEEDBACK
1 Badge = Very easy
2 Badges = Easy
3 Badges = Moderate4 Badges = Harder than average
5 Badges = Professional skills required
This shower is rated 3 Badges
3 4
7/30/2019 900 Series Ins
3/23
7/30/2019 900 Series Ins
4/23
Whats In The Boxes?
Please check with pictures, some of the items have been assem-
bled by ourselves in order for ease of recognion as to what they
are and can be used as reference in later construcon
1. Shower tray2. Roof secon
3. Shower waste (part of fing kit if purchased)
4. Overhead shower head fied (loosely)
5. Shower hand held
6. Ozone box
7. 2 x screw packs
8. Foot Spa9. Glass shelf pack
10. Extractor fan (fied)
11. Brass nut
12. Hand shower riser bar
13. Shower hose
14. Foot Spa flexi hose
15. Operaons handbook (not required all contained in write up)
16. 90 degree elbow for hand shower feed
Note: Protecve film should be removed
Before starng the installaon!
For the latest fing instrucons please visitwww.insigniarange.co.uk For the latest fing instrucons please visitwww.insigniarange.co.uk7 8
7/30/2019 900 Series Ins
5/23
For the latest fing instrucons please visitwww.insigniarange.co.uk
Glass pack
2 x curved doors1 x door handle pack
Lengths of glass seal trim
2 x magnet trim
2 x front upright columns
2 x corner columns
2 x door seals
For the latest fing instrucons please visitwww.insigniarange.co.uk
Rear glasses x2 and 2 x top and boom curve supports
9 10
Centre control column,
grab handle and back
seat rest.
7/30/2019 900 Series Ins
6/23
For the latest fing instrucons please visitwww.insigniarange.co.uk For the latest fing instrucons please visitwww.insigniarange.co.uk
VERY IMPORTANT
Have you got everything? If not please contact your supplying deal-er now. Remember NEVERbook your tradesman unl everything
has arrived, been checked and is present. No replacement / miss-
ing parts can obtained free of charge during or aer build only
within the mescale permied (48 hours aer delivery) and always
BEFORE build.
GOT EVERYTHING AS YOU SHOULD?
GREAT NOW FOR BUILD PLEASE READ ON!
TO START.
Make sure you have a clear space, remember when finished and in
place you need access to check your build and able to pull the
shower out should you need to replace anything!
Take the shower tray remove all protecve wrapping and fit waste.If you purchased the fing kit it is possible this could have been
already been fied in the tray hole but please note it will only have
been for transport and will need sealing correctly and alignment
for your house waste. In the side of the waste supplied in the op-
onal fing kit you will noce a spigot not seen on an ordinary
waste. In most cases this is blanked, you need to gently drill this
out now. NOTE: IF YOU PURCHASED A NON STEAM VERSIONSUCH AS 9013 MODEL DO NOT DRILL THIS OUT. This item is for
the steam generator waste and will be connected in instrucons
later.
Now on the surface the shower is to finally rest take the tray and
place accordingly. Level tray with water run off slightly towards the
drain. This is done by adjusng the feet fied underside
11 12
Check Levels both
Note 4 x water run
offs (model varies)
Tray Feet
7/30/2019 900 Series Ins
7/23
When you are happy the tray is set up correctly you can now move
this out to a beer working posion.
Taking now the le hand (as you look from the front) rear wall, it
will have LEFT wrien on it and this will be at the top. Also take
the centre column with appliances aached to it and place on the
shower tray. Now using screws provided aach the centre column
to the le hand wall 4x screws. Having completed this place a fur-
ther 2 x screws through the rear of boom le hand panel into the
tray. Please note slots are cut into channel should you need slight
adjustment. When complete repeat this operaon taking the right
hand panel again marked as the le was and repeat procedure you
have just undertaken. You now have the tray, centre column and
both back walls aached
For the latest fing instrucons please visitwww.insigniarange.co.uk
2 x screws placed through boom of glass frame into shower trayTaking
For the latest fing instrucons please visitwww.insigniarange.co.uk13 14
ABOVE: Applying sealer to inner trim to be stuck to glass section
Screw through pre-cut holesYour shower will now look
like this
7/30/2019 900 Series Ins
8/23
Moving on to the top and boom curved rails and the two upright
aluminium columns. Columns fit on each end of the exposed rear
panel glasses and will form the front part of the shower support.
Take one column (each are marked TOP) and the boom curved
rail, at the boom of each upright you will see two slots, screw the
upright to the curve with screws supplied through slots. Taking the
second column screw this to the opposite end of the curve. NOTE
curve will have the seal built into the frame at the boom. You will
now have two upright columns aached to one curved rail.
For the latest fitting instructions please visitwww.insigniarange.co.uk
Column showing UP
Now offer your assembly onto the front of the shower tray (as pic-
ture 2nd
up) The columns will now fit snug to the end of the glass
rear panels. Note screw holes pre-drilled. Taking appropriatescrews screw the column to the glass panel frame. Repeat this at
the other end.
For the latest fitting instructions please visitwww.insigniarange.co.uk
15 16
Screw column to curve rail not as picture but before it is placed on
tray as the second hole will not be assessable otherwise.
With columns and boom curved rail in place you now need to fit
the side glasses. Taking one glass place seals on them as picture
shows.
7/30/2019 900 Series Ins
9/23
NOTE: 2 x seals press onto glass
When you have placed the seals correctly over glass edges offer
one up to the upright column you have just fixed to the rear glass
frame. Now firmly press into the channel found on the front.
For the latest fing instrucons please visitwww.insigniarange.co.uk
When this stage is complete repeat the same assembly with the
second glass and again firmly press into the other channel.
Now take the 2 x front columns with grey plasc clips aached.
Press one into the opposite end of the glass panel you have just
fixed and over the seal. NOTE. Make sure this is firmly home with
seal in place. When you are sure the front column is correct and
seal fully in place, you now need to fix the top curved rail. Place in
posion carefully insert the top grey clips very carefully so as not
to break them and screw both ends to the top of the end columns
as you did with the boom curved rail.
For the latest fing instrucons please visitwww.insigniarange.co.uk17 18
Column seal and glass press
into channel (shown in red)
Upright front columns now fied before fing top rail
7/30/2019 900 Series Ins
10/23
Offering up the top rail to slot into clips
For the latest fing instrucons please visitwww.insigniarange.co.uk
You now need to fix the two front columns into place. Align the pre
drilled holes and screw into place as the picture below shows:
Picture shows top fixing repeat both sides and at the boom aswell
Now your assembly is almost complete. Just the doors and roof
need fing. Take one door, now fix wheels on this top and boom
but leave all four loose. Fit door handle also. On the leading edge
fit 1 x magnet strip. On trailing edge fit L shaped steam retaining
seal. When complete offer the door into the channel runners andnote the wheels are on cams adjust each unl the door runs
smoothly. Repeat the same procedure on the second door. NOTE
get magnet round the correct way the two doors need to aract
not repel! NOTE. Any gap between the doors can now be adjusted
to close perfectly by adjusng the second door wheel cams to
align.
For the latest fing instrucons please visitwww.insigniarange.co.uk19 20
Screwing top curved rail
into place
Shower top curve
secon will now look like
this
7/30/2019 900 Series Ins
11/23
For the latest fing instrucons please visitwww.insigniarange.co.uk
Top door wheels in place note cam adjustment
Now taking the complete roof secon make sure the overhead rain
shower is ght and offer over the structure to fit inside frame sup-
port. When in place screw through pre drilled holes.
For the latest fing instrucons please visitwww.insigniarange.co.uk21 22
2 x boom wheels in runner
Magnets fied to doors to aract each otherPlace over shower frame
7/30/2019 900 Series Ins
12/23
For the latest fing instrucons please visitwww.insigniarange.co.uk For the latest fing instrucons please visitwww.insigniarange.co.uk23 24
Align in place for snug fit
Screw into place
You now need to fit all internal items supplied inside the show-
er cabin. These are for 9040, 9008, 9012, 9013 models
Hand shower riser bar,
flexi hose and actual hand shower
Handle grab
Press rear seat back rest on knobs supplied (NOTE: 9040 model
has no seat or back rest)
Foot spa and hose
Assemble chrome rack
All of which are self explanatory but picture below can be used
again to check locaon.
Congratulaons nearly finished, you are now ready to couple wa-
ter hoses!
7/30/2019 900 Series Ins
13/23
Seal where shown in red on assembly!
- Not aer
For the latest fing instrucons please visitwww.insigniarange.co.uk
Electric Connecons.
At this stage you will need to connect the following. These are all12V and considered safe for DIY connecon as each is labelled
and low voltage.
NEVER CONNECT TO MAINS AT THIS STAGE
Overhead light * Led rear panel lights* Ozone (if fied) * Speaker *
fan * Aerial (unfold if fied) * C.D Telephone (if required most do
not bother!) external jacks if required NOTE! If you purchased the
oponal shower tray skirt lights these join to the rear internal led
light connecon.
Idenfy these connecons and snap together with connector
blocks on the end of each. Telephone will need hard wiring from
another socket point in your house
If you have purchased the 9013 model then simply plug in the 12volt adapter aer all the connecons have been made.
For the latest fitting instructions please visitwww.insigniarange.co.uk
25 26
Also run a bead of silicone up the inside rear of the column
7/30/2019 900 Series Ins
14/23
Shower Water Connecons
Going to the rear of the shower, you now have hoses coming fromthe water diverter valve, these are marked as to their locaon.
Connect each to their respecve posions. NOTE Check each con-
necon has a seal in before ghtening fully. Please note overhead
shower shows arrow to le, in fact this goes vercal.
For the latest fing instrucons please visitwww.insigniarange.co.uk For the latest fing instrucons please visitwww.insigniarange.co.uk27 28
Now remove plasc protecon cover and check all jets are ght.
These are only placed in posion for transport. NOTE: Do not over
ghten! Now check ALLhose clips these will be loose as well, ght-
en unl hose cannot move. Now remove the 3x flexi braided hoses
(Only two if non steam 9013 model!!) and check clear neoprene
washers are in place if all good ghten in posion. At the boom of
the column check the steam pod and ghten this in posion.
Leave plasc protecon cover off.
Check hose clips and ghten all of them. Dont forget braided hos-
es as well!
Double assurance! Silicone behind each jet nut before
ghtening
7/30/2019 900 Series Ins
15/23
What Should I Know About Steam Room Safety?
Please visit the following link:hp://www.insigniarange.co.uk/instrucons/
Steam_Safety_Please_Read.pdf
For the latest fing instrucons please visitwww.insigniarange.co.uk For the latest fing instrucons please visitwww.insigniarange.co.uk29 30
Connecng the steam generator
Fied at the boom of the shower rear panel (NOT APPLICABLE
TO 9013 NON STEAM MODELS) you will find the steam generator
which will look similar to the picture below. Connect white insu-
lated hose to the shower steam pod. This is located below the
seat in the cabin and connecon is at the rear for ease. Check
now by picture or words wrien on the generator box, Water In
This will connect to the middle braided hose found coupled to the
rear of the water valve you just ghten connecons to. Finally if
the fing kit was purchased couple the last connecon which is
Steam Generator water waste This goes from the generator to
the shower tray spigot menoned at the earliest stage
(Remember? You drilled this out!). If no waste purchased you will
need to make your own arrangements to connect somewhere
else into the house waste or call 0844 800 3069 to order the spe-
cial waste. Remember to ghten all connecons
See typical set up overleaf..
Checked neoprene seals are in
posion?
Water In
Drain/Water Out
Steam Out
Important!
Never use the steam
generator with the vent
holes poinng towards
the shower wall or a
person.
Never use the steamoutlet in the closed posi-
on. This excessive heat
will damage your tub
and this is NOT covered
under your warranty
terms.
7/30/2019 900 Series Ins
16/23
7/30/2019 900 Series Ins
17/23
TESTING PRODUCT.
With the shower sll not fully posioned as you will require it.
Complete the following tests:
Electrical. Switch unit on and test all features contained. Lights,
Ozone if fied, radio, TV, underwater light, fan. Below is a copy of
the control panel and what each feature operates
For the latest fing instrucons please visitwww.insigniarange.co.uk
1. On/Off Switch
2. Radio frequency
3. Volume seng
4. Steam Unit operaonPress this buon to acve the steam
funcon. If no water is present the unit will not funcon for safety
reasons.
5. Light Operaon
6. Telephone answerPress to answer the phone if connected.
7. Volume/tune up
8. Panic Alarmpress to acve, then turn the unit off by buon 1
to turn it off.9. Staon memory. Press this to select your preset staons be-
tween 1-10. If you are turning your radio, once you have the sta-
on selected press Mem to assign a preset staon. Keep pressing
the Mem buon unl you have selected the required present
staon number. Now leave it to stop flashing to preset the staon.
10. LockThe lock will turn on automacally. To disable hold
buon for 3/4 seconds and the padlock display will change to anopen icon.
11. SetSwitches between tune and volume
12. Switches between the radio and the CD player (if fied) or
turns both off.
13. Ozone acvaon (If Fied) Run this feature for 10-15 minutes
to clean the shower cabin.
14. Fan operaon
15. Control panel lock icon on/off
16. Room Temperature sensor
17. Light display icon
For the latest fing instrucons please visitwww.insigniarange.co.uk33 34
9
7/30/2019 900 Series Ins
18/23
CONTROL PANEL FOR NON STEAM 9013 MODEL
For the latest fing instrucons please visitwww.insigniarange.co.uk
1. On/Off Switch
2. Light On/Off
3. Rear internal Led lights and tray lights if fied
4. Fan Operaon
5. Radio Operaon
6. Volume Up
7. Volume Down
8. Reset The radio
9. Tune
10. Telephone Answer
For the latest fing instrucons please visitwww.insigniarange.co.uk35 36
12
34
5
6
7
8
9
10
7/30/2019 900 Series Ins
19/23
Your completed shower should now look like this:
For the latest fitting instructions please visitwww.insigniarange.co.uk
TESTING FOR WATER LEAKS
LEAVING SHOWER 24 HOURS AFTER BUILD ALLOWING SEALENT TO
CURE HAVE YOU BUILT THIS CORRECTLY? FIND OUT NOW.
With all connecons ght, the waste and hoses checked, jets fully
sealed, your shower sll around18 inches from its designated final
resng point and the silicone sealer fully cured (hence leaving for
24 hours at min) Switch on the overhead shower NOT massage jets
remember these will fire water out at you and are not suitable forchecking leaks as they would normally only operate when a person
is fully in front of them. Just use COLD water seng as hot will
make cabin misty and condensate thus the inspecon becomes
very difficult. Now on the OUTSIDE inspect each joint, factory seal,
hose, clip, jet, from one side going round to the back and then oth-
er side finishing at the front. If you have a small leak (normally
caused through insufficient sealer or air bubble on assemble. Dryarea thoroughly and reseal on the OUTSIDE. Again remember
where you see water may not be exactly where the leak is, it could
have run round to a low point. Never seal anything inside unless
you feel it necessary and make sure it is thin and neat, remember
you will see this for the life of your shower! Leave to cure again
and check. If all good now check shower funcons, Jets for back
massage, foot massage, (if you have one) and finally hand shower,
check your joints to these funcons at the rear again. Never use
the shower unl all checks have been made and the installer is
100% happy in the knowledge no leaks are present. All good? Now
push your shower FROM THE BASE NEVER GLASS OR FRAME into
its final resng posion. Now you can shower in the knowledge
that you have no leaks a job done well and long product life.
For the latest fitting instructions please visitwww.insigniarange.co.uk37 38
9008 / 9008S / 9012 / 9013 9040
7/30/2019 900 Series Ins
20/23
7/30/2019 900 Series Ins
21/23
7/30/2019 900 Series Ins
22/23
7/30/2019 900 Series Ins
23/23
For the latest fitting instructions please visitwww.insigniarange.co.uk For the latest fitting instructions please visitwww.insigniarange.co.uk43 44
Amendments
It may be apparent that you have the latest model which is a click
clack style build. It is important to recognise this as when it comes
to building the shower, once you have the tray in place you need
to build the front glass frame first than click the rear panels in to
place followed by the column last. If you fail to follow this instruc-
on your build will be incorrect and you will have to start again!
To recognise if you have the correct model please check the follow-
ing:
Does your metal up-
rights have a grove on
the framework as
shown below? If so
then you Must follow
the instrucons above
in connecon with thebooklet. if you do not
have this grove then
please follow the
booklet from the be-
ginning ignoring this
amendment.