25
© 2013 IBM Corporation This document is for IBM and IBM Business Partner use only Client Technical Specialist IBM System Storage IBM Storwize V3700 Revisão: 19/02/2013

9 - BtS 2013 V3700 V1

Embed Size (px)

Citation preview

Page 1: 9 - BtS 2013 V3700 V1

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Client Technical SpecialistIBM System Storage

IBM Storwize V3700

Revisão: 19/02/2013

Page 2: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only2

Agenda

Posicionamento no PortfolioV3700 HardwareV3700 Funcionalidades

Page 3: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

IBM Smarter Storage PortfolioEntry/Midrange

Storage Systems

• Storwize Family

• DS Family• DS5000• DS3000

Enterprise Storage Systems

• DS8000 Family • DS8700• DS8800• XIV Family• XIV Gen2 • XIV Gen3

Efficiency “Enhancers”

File Storage Systems

Data ProtectionAnd Retention

• Scale-Out NAS (SONAS)

• V7000 Unified• B&F I/O• N Series• N7000• N6000• N3000

• TS Family • TS7000• TS3000• TS2000• TS1000• ProtecTIER

Deduplication• Information

Archive

• Real-Time Compression

• Easy Tier• SAN Volume

Controller (SVC)

• Active Cloud Engine

Storage Management

SoftwareTivoli Productivity

Center (TPC)Tivoli Storage

Manager (TSM)Tivoli Key Lifecycle

Manager FlashCopy Manager

(FCM)

Page 4: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only44

Storwize V3500(China only)

Storwize V7000

Storwize V7000 Unified

Storwize V3700

Flex System V7000

SAN Volume Controller

• One code base on all platforms• One set of functions (selectively licensed)

• One user interface• One CLI

Meet The Storwize Family

A comprehensive range of fully virtualized storage systems

Page 5: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only5

Virtual Storage Center

IBM Smart Analytics

Solutions (ISAS)

Integrated Solutions

ForEnterprise Workloads

XIV SONASDS8000

For Midrange& Entry

Workloads

For Data Protection

and Retention

Optimized Storage Systems

N seriesStorwize family DS3500

V7000 Unified

V7000 Unified

V7000 Unified

V7000 Unified

Tivoli Storage Productivity Center

Tivoli Storage FlashCopy Manager

Tivoli Storage Manager

Tivoli Key Lifecycle Manager

Storage Management

Software

Built-inInnovation

Storage Virtualization SW and SVC

Real-time Compression

Deduplication

Easy Tier

IBM Active Cloud EngineTM

Linear Tape File System

(LTFS)

IBM Storage Portfolio

Enterprise Tape Virtualization

Tape LibrariesTape drivesProtecTIER

Systems

Page 6: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only6

– Easy-to-use, embedded graphical user interface – Thin provisioning capabilities: allocate the exact amount of

space needed at the time it is required– Non-disruptive migration from existing FC storage helps

speed implementation and minimize disruption– Sophisticated data protection with FlashCopy technology– Multi-protocol support (iSCSI, FC and FCoE and SAS1),

provides consolidation flexibility– Full interoperability: extensive suite of Microsoft and

VMware solutions supported

Advanced software features

Helps manage, deploy and administer SMB IT environments:

1 Statement of Direction. IBM Plans are subject to change without notice

Page 7: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only7

Efficient Entry Storwize System

Enclosures– 12 LFF (3.5”) or 24 SFF (2.5”) drives in just 2U

Control enclosure: dual active-active controllers and drives– 8GB Cache (4GB per controller) standard; optional upgrade to 16GB

– 1Gb iSCSI host ports standard plus optional 8Gb FC or 10Gb iSCSI/FCoE or SAS1 host interface upgrades

Expansion enclosure:– Up to four expansion enclosures attach to one control enclosure

– Up to 120 SFF or 60 LFF drives for up to 180TB raw capacity

– Mix drive sizes and HDD/SSD in enclosure

– Dual-active expansion canisters

RAID levels 0, 1, 5, 6, and 10 Redundant, hot-swappable components (i.e., power supplies and fans) AC power (110 to 240 V) Optional Software1: Easy Tier, Remote Mirroring, FlashCopy upgrade (2048 targets)

1 Statement of Direction. IBM Plans are subject to change without notice

Page 8: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Storwize V3700 Drive Options

Small form-factor (2.5 inch) HDD(max. 24 per enclosure)

15,000 RPM 146GB, 300GB SAS

10,000 RPM 300GB, 600GB, 900GB SAS

7,200 RPM 500GB, 1TB Nearline SAS

Small form-factor (2.5 inch) SSD(max. 24 per enclosure)

200GB, 400GB E-MLC SAS

Large form-factor (3.5 inch) HDD(max. 12 per enclosure)

7,200 RPM 2TB, 3TB Nearline SAS

Drives of same form-factor may be freely intermixed without limitation in an enclosure

Page 9: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Functionality and models

9

Function Feature

Virtualization of internal storage Standard

Thin provisioning Standard

Data migration (one-way) Standard

FlashCopy (up to 64 targets) Standard

Interoperability Same as SVC / Storwize V7000 in 3Q’2012

Code license IBM Agreement for Licensed Machine Code

Warranty 3 years (9x5 NBD with CRUs)

Offering availability Worldwide

Part Number Nomanclature2072-12C V3700 control enclosure 12 x 3.5”

drives2072-24C V3700 control enclosure 24 x 2.5”

drives2072-12E V3700 expansion enclosure 12 x 3.5”

drives2072-24E V3700 expansion enclosure 24 x 2.5”

drives

Page 10: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only10

Control Enclosure

• Rear of the Enclosure:• There are two power supply slots along the bottom of the unit, each taking up

half of 1U. The left hand slot is power supply 1, the right hand slot is power supply 2. The power supplies are inserted the same way up.

• There are two canister slots along the top of the unit, again taking up half of 1U The left slot is canister 1, the right slot is canister 2. The canisters are inserted the same way up.

• Fans are contained within the PSU, replacement requires a new PSU• Fan speed is variable and under system control• Fans continue to operate in a PSU which has failed or lost AC power

2U 19 inch rack mount enclosureFour enclosure modelsControl/Expansion and/or 12/24 drivesNo controls on the enclosure

Page 11: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Node Canister

USB 1GbE ports(2)- Management(1)- iSCSI

6Gb SAS portsOptional HIC- 4x 8Gb FC- 4x 1GbE (iSCSI)- 2x 10GbE iSCSI/FCoE

• Four 6 Gb/s SAS ports – only 1 used in R1 ( port 4 ) for additional enclosure connections• Two USB 2.0 ports (one port used during install)• Two 1Gb Ethernet ports. Usage of port 1 is required, port 2 is optional• Optional Host Interface Cards

• 4 x 1Gb/s Ethernet ports ( iSCSI )• 2 x 10Gb/s Ethernet ports ( iSCSI/FCoE )• 4 x 8Gb/s Fibre Channel ports ( FC )

Page 12: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Node Canister – Battery Backup Unit ( BBU )

Any power loss will trigger: I/O to stop, backup of hardened data, fire hose dump and node shutdown.

Storwize V3700 requires battery backup to save node metadata in the event of both power inputs failing

Battery Backup Unit ( BBU ) inside each node canister The BBU only needs 1 second of testing every 3 months rather than the full discharge &

recharge cycle needed for the Storwize V7000 batteries.

The Battery test is performed while the node is online It is only performed if the other node in the control enclosure is online if the battery fails the test, the node will go offline immediately. The battery is automatically tested every time the operating system is powered up

Page 13: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Expansion Canister

2 x 6Gb/s SAS ports, usage of port 1 is mandatory Only V3700 canisters are supported in the chain

Page 14: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

SAS Cabling• V3700 node canister has a single SAS chain• V3700 supports up to 4 expansion enclosures• Node canisters use SAS port 4 for expansion

connection

In release 1, SAS ports 1-3 are unusedOnly “Top down” cabling is supported

Diagnostics ensure proper cabling

Page 15: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

New mini SAS HD connectors

DS3500 and Storewize V7000 use the SFF-8088 ( mini SAS )

V3700 uses the SFF-8644 ( mini SAS HD )

15

Mini SAS

Mini SAS HD

V7000 / DS3500

V3700

New Expansion Enclosure Attachment Cables0.6m SAS Cable (mSAS HD)

Feature ACTA SEO/PN 00Y2465

1.5m SAS Cable (mSAS HD)

Feature ACTA SEO/PN 00Y2467

3m SAS Cable (mSAS HD)

Feature ACTA SEO/PN 00Y2469

Page 16: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Replaceable Parts

Customer Replaceable Units (CRU)- PSU ( containing Fans )- Node / Expansion canisters- Battery Backup Unit (BBU)- Cache memory- Host Interface Card (HIC)- All Disk Drives

Field Replaceable Units (FRU)- Enclosure midplane

Enclosure metalwork not replaceable

16

PSU

Canister

HIC

MemoryBBU

Page 17: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Resumo do software do V3700 em Dez/2012

IBM Statement Of Direction (**):– Suportar SAS Host Attachment– Easy Tier– Remote Mirroring– Suporte de até 2040 Flashcopy target volumes

Não suporta compressão de dados Não suporta virtualização externa

– Suporta Image Mode para migração

– ** Note: IBM's statements regarding its plans, directions, and intent are subject to change or withdrawal without notice at IBM's sole discretion. Information regarding potential future products is intended to outline our general product direction and it should not be relied on in making a purchasing decision. The information mentioned regarding potential future products is not a commitment, promise, or legal obligation to deliver any material, code, or functionality. Information about potential future products may not be incorporated into any contract. The development, release, and timing of any future features or functionality described for our products remains at our sole discretion.

17

Page 18: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Outras questões

Suporta DAS Fiber Channel para alguns hosts– Consultar IBM System Storage Interoperation Center (SSIC)

V3700 roda um 'Licensed Machine Code' – Não é software como o V7000– Não é necessário fazer licenciamento como é o V7000

18

Page 19: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

1 Statement of Direction; planed to release in 2013. IBM plans are subject to change.

Comparing Storwize V3700 and Storwize V7000Storwize V3700 Storwize V7000

Management SW Storwize V3700 machine code Storwize V7000 software

GUI Easy to use, innovative and intuitive user interface Easy to use, innovative and intuitive user interface

Capacity Up to 120 drives per control enclosure (up to 4 expansions)

Up to 240 drives per control enclosure; 960 per clustered system

Standard Host Ports 1Gb iSCSI, 6Gb SAS1 1Gb iSCSI, FC

Optional Host Ports iSCSI 10Gbps, FC, FCoE iSCSI 10Gbps, FCoE

Cache (dual controller) 8GB upgradeable to 16GB 16GB per dual controller, up to 64GB per clustered

system

Integrated Features

FlashCopy (64 images per system),Internal virtualization, Thin provisioning, Data

Migration,

FlashCopy (4,096 images), Internal virtualization, Thin provisioning, Data Migration, Easy Tier,

System Clustering

Optional Features Statement of Direction: FlashCopy (2040 images)1

Remote Mirroring1, Easy Tier1 Remote Mirroring, Real Time Compression,

External Virtualization

External Virtualization No Yes, Optional

Unified Support No NAS connectivity supported with Storwize V7000 Unified; IBM Active Cloud Engine integrated

Page 20: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use onlyFor IBM and IBM Business Partner staff information only. Not intended for--or distribution to--customers or other third parties

Comparing Storwize V3700 and DS3500

1 Statement of Direction; planed to release in 2013. IBM plans are subject to change.2 Equivalent of DS3500 host kits and partitions included as standard with Storwize V3700

Storwize V3700 DS3500

Management SW Storwize V3700 machine code DS Storage Manager

GUI Easy to use, intuitive user interface based on innovative Storwize V7000 GUI

Robust functionality with easy-to-understand GUI and wizards

Capacity Up to 120 drives (up to 4 expansions) Up to 192 drives (up to 7 expansions)

Standard Host Ports 1Gb iSCSI, 6Gb SAS1 6 Gb SAS

Optional Host Ports iSCSI 10Gbps, FC, FCoE iSCSI (1Gbps and 10Gbps), FC

Cache (dual controller) 8GB upgradeable to 16GB 2GB upgradeable to 4GB

Integrated FeaturesFlashCopy (64 images per system),

Internal virtualization, Thin provisioning, Data Migration, Integrated Server Support2

FlashCopy (2 images per system), Thin provisioning, Dynamic Disk Pooling

Optional Features Statement of Direction: FlashCopy (2040 images)1

Remote Mirroring1, Easy Tier1

FlashCopy (512 images), Remote Mirroring, Turbo Performance, Full Disk Encryption (SED), Host

kits and Partitioning2

Telco Industry Standard No NEBS / ETSI compliance

Page 21: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

Storwize V3700: Competitive advantagesPricing Advantage and Competitive Differentiators vs WW Storage Vendors

1 Basic configuration includes dual controller, 3.6 TB SAS raw and basic SW (with typical discounts)2 Calculation based on VNXe3100 price

Source: Ideas Competitive Profiles, CompeteLine Collateral and External Webpages of each competitor

ProductTypical Street Price (USD)

Basic configuration1Differentiators (included in base price)

IBM Storwize V3700 ~$11,000 Ease to use GUI, Thin Provisioning, FlashCopy and Data

Migration included in base price

HP P2000 ~$12,800 Spin Down drives, Snapshots included

DELL PS4100, MD3x00PS4100: ~$18,400MD3x00: ~$13,300

PS4100: Scale-out systems (dual clustering), Thin Provisioning, Snapshots and Application-specific copies included

MD3x00: Snapshots (limited)

EMC VNXe3x00VNX5100VNXe3150: ~$9,8002

VNX5100: ~$11,800

VNXe: Block (IP) & File access, Thin Provisioning, Snapshots, Deduplication included

VNX5100: Snapshots and Thin provisioning included

Page 22: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

V3700 e concorrentes

IBM Host Connectivity: V3700 supports iSCSI, FC and FCoE Software: V3700 includes Thin Provision, data migration, Flashcopy, Management in basic price Administration: Free GUI is based on the award winning XIV GUI

Dell Host Connectivity: Supports FC , iSCSI and SAS - But not on all models. EqualLogic don’t support FC – only iSCSI. If

customers requires NAS support a gateway with a separate management interface is needed. Software: No Thin Provision and data migration support. Administration: Uses Modular disk storage manager.

EMC Host connectivity: Supports FC or iSCSI or iSCSI/NAS Software: Includes Thin Provision and data migration as a mandatoIry option adding to the price of the solution Administration: EMC is using Unisphere Manager

22

IBM Dell EMC HP Huawei Netapp HDS

V3700 MD32XX/36XX PS4100/6100

VNXe3150/3300 VNX5100/5300

P2000G3 P4000 S2200TS2 600T FAS2200 HUS110

Page 23: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

V3700 e concorrentes

HP Host Connectivity: HP P2000 supports FC, iSCSI, SAS and FCoE. but on different models. P4000 only supports iSCSI. If

customers requires NAS support on P2000 or P4000 a gateway with a separate management interface is needed. Software: HP don’t support Thin Provision and data migration on P2000. P4000 supports Thin Provision. Administration: HP is using P2000 Manager or SAN/iQ Centralized Management Console for P4000 LeftHand.

Huawei Host Connectivity: Huawei supports FC, iSCSI. If customers requires NAS support a gateway with a separate management

interface is needed. Software: Huawei don’t offer Data migration. Administration: Huawei use OceanStor ISM management

Netapp Host Connectivity: Netapp FAS2200 supports FC, iSCSI, FCoE and NAS Software: Netapp don’t offer Data migration Administration: Netapp is using System Manager

23

IBM Dell EMC HP Huawei Netapp HDS

V3700 MD32XX/36XX PS4100/6100

VNXe3150/3300 VNX5100/5300

P2000G3 P4000 S2200TS2 600T FAS2200 HUS110

Page 24: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only

V3700 e concorrentes

HDS

Connectivity: HDS supports FC, iSCSI and NAS. Software: HDS do not have Datamigration. Administration: HDS is using SNM2 and Device Manager for management as a part of the chargable BOS E operating

system on HUS 110 only.

24

IBM Dell EMC HP Huawei Netapp HDS

V3700 MD32XX/36XX PS4100/6100

VNXe3150/3300 VNX5100/5300

P2000G3 P4000 S2200TS2 600T FAS2200 HUS110

Page 25: 9 - BtS 2013 V3700 V1

IBM System Storage

© 2013 IBM CorporationThis document is for IBM and IBM Business Partner use only25

Fim