1
Side 2 16 Install Rack Mount Kit (Optional) If you intend to configure your server as a pedestal system, disregard this step and proceed to Step 17. If you intend to configure your server as a rack-mount system, go to the instructions that came with your Rack Mount Kit to complete your server assembly. 15 Install Feet 1 2 Note: Repeat above steps until all four feet are installed. Secure foot by inserting pin through the rubber foot. Insert rubber foot into chassis hole. 1 2 Note: This step applies to the pedestal version only. If you plan to configure your chassis as a rack mount system, go to Step 16. 10 Install Hot-Swap Drive Cage Kit (Optional) If you intend to configure your server with SATA/SAS hot swap hard drives, go to the instructions that came with your drive cage upgrade kit to install the drive cage and hot-swap drives. 9b Install Tool-less Fixed Hard Drives (If installing a hot-swap drive cage, go to Step 10) 7 Install power and data cables to each of the installed drives. The cables route through the oval opening at the bottom of the drive cage. 7 8 Re-attach drive cage EMI shield to chassis. 9 Tighten thumb screw. 8 9 Accessories and Order Codes 6-Drive SAS/SATA Hot Swap Cage without expander 6-Drive SAS/SATA Hot Swap Cage with expander Intel ® Server Chassis Rack Mount Kit IIntel ® Server System SC5650BCDP Product Maintenance Kit AXX6DRV3GR 1 AXX6DRV3GEXP 1 APP3RACKIT APPTPMKIT Hot Swap Conversion Kit APPTHSDBKIT 1 Requires a Hot Swap Conversion Kit to integrate into the Intel ® Server System SC5650BCDP. A complete list of accessories and spares can be found at: http://support.intel.com Document Type Available Documents Technical Product Specification Spares and Configuration Guide Software and Drivers Content In-depth technical information Supported accessories and spares list Up-to-date firmware, driver and utility information Additional Reference Documents available at: http://support.intel.com 18 Close System 2 1 1 Replace screws. 2 Slide the side cover on chassis and latch securely. CAUTION: This chassis must be operated with the SIDE COVER installed to ensure proper cooling. 14 Remove Filler Panels Remove the bezel filler panels for each drive you have installed. Release plastic tabs located at back side of bezel and pull out filler panels from front. 8 Install Tool-less CD-ROM or DVD-ROM Drive 1 2 3 2 1 Remove EMI shield from 5.25-inch device drive bay. Make sure latch is in "unlock" position. Line up holes in CD-ROM or DVD-ROM drive with holes in chassis. Connect power (P5 or P6) cables and data cables to rear of the CD-ROM or DVD-ROM Move latch to "lock" position. Insert CD-ROM or DVD-ROM drive into device drive bay. An additional 4-pin IDE male-to-SATA 15 pin power cable adapter may be needed if the CD-ROM or DVD-ROM does not have a 4-pin power connector. 6 5 4 Data cables are included with the Intel ® Server Board. 3 5 4 6 Data Power 17 Install Front Bezel Assembly Engage three clips at right edge of chassis. Rotate left side of bezel assembly toward chassis. Snap two bezel tabs into corresponding recesses at left edge of chassis front panel. 1 3 2 3 1 1 1 2 3 Chassis Features and Components A. Front Panel B. 5.25-inch Device Drive Bays (2) C. Hard Drive Cage Access Door D. Door Lock E. USB Ports (2) F. Fan Duct and System Fan (DP/WS/BRP configuration shown) G. Hard Drive Cage Retention Mechanism H. Alternate external SCSI Knockout I. Fixed Hard Drive Fan J. SC5650BCDP Mother Board K. Padlock Loop L. PCI Card Guide M. External SCSI Knockout N. Serial B port Knockout O. Power Supply (fixed illustrated) P. A/C Power In Q. I/O Shield R. PCI Add-in Board Slots H J K M N O P R Q L I A C B D E G F 12 Install PCI Card Guide 1 Insert tabs on left side of PCI card guide into slots in chassis. 2 Swing PCI card guide into chassis until right-side blue tabs snap into place. 1 2 9a Install Tool-less Fixed Hard Drives (If installing a hot-swap drive cage, go to Step 10) (Continued...) Insert fixed drive cage into chassis. 1 1 2 Route power and data cables through cable routing area at the bottom of the fixed drive cage. 3 Pull the drive latch forward for the drive bay you want to install a hard drive in. Drive slots 1, 3, and 5 MUST be populated first. Failure to do so could result in thermal issues within chassis. 3 1 2 4 3 5 6 4 Insert fixed hard drive into drive bay until it stops. Ensure that the power and data connector end of the hard drive is facing forward. 4 5 Push drive latch in to lock hard drive into drive bay. Install additional drives as necessary. 6 5 Server Board S5500BC Component Layout See your Intel ® Server System S5500BCDP User's Guide for expanded component and connection information. ICH10 Note: Refer to the Technical Product Specification for Diagnostic LED decoder list. Diagnostic LEDs DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 DIMM_E1 DIMM_E2 DIMM_D1 DIMM_D2 CPU 1 Socket CPU 2 Socket Slot 7 (PCI Express* x8) Slot 6 (PCI Express* x8, Riser Card) Slot 5 (PCI Express* x4) Slot 4 (PCI 32/33) RMM3 Slot 3 (PCI Express* x4) NIC 2 USB 9 USB 8 NIC 1 USB 7 USB 6 VGA Serial A SYS FAN 3 SYS FAN 2 SATA 4 USB 2-3 USB 0-1 SATA 5 Serial B HSBP_A Main Power CPU Power BIT1 LSB DIMM Fault LEDs Front Panel Header CPU 1 FAN SYS FAN 1 CPU 2 FAN DIMM Fault LEDs IOH P/S AUX SATA RAID Key Status LED ID LED BIT3 BIT2 BIT6 MSB BIT4 BIT5 BMC SATA 0 SATA 1 SATA 3 SATA 2 Battery IPMB_1 SATA SGPIO 13 Install PCI Add-in Boards While holding the PCI add-in board by its top edge or upper corners, firmly press the add-in board into the expansion slot. 3 Close the back panel PCI add-in board retention device. 4 4 From inside of chassis, press open the back panel PCI add-in board retention device. 1 1 Remove the PCI slot shield by pressing the shield out from the inside of the chassis. 2 2 3 Front Panel Controls and Indicators A. Power/Sleep LED B. Power/Sleep Button C. NMI Button D. Reset Button E. NIC 1 Activity LED F. NIC 2 Activity LED G. Hard Drive Activity LED H. Status LED A C F H B D E G Reference 19 Finishing Up 1. See your Intel ® Server Board Quick Start User's Guide to connect your keyboard, mouse, video and other I/O cables. 2. Connect the AC power cable last. CAUTION: Power supply requires a 16-gauge power cord. 20 Install Software BIOS, Drivers, and Operating System Install A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://support.intel.com/support/motherboards/server/S5500BC/ If new versions are available, update the BIOS on your server. See the User Guide on the Intel ® Server Deployment Toolkit CD for update instructions. B. Configure your RAID Controller: Use the instructions provided with the RAID controller. C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft* Windows*operating system, the Express Installer will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. 11 Complete Server Board Connections See your Intel ® Server Board Quick Start User's Guide or the User Guide for server board cable connections. Fan Connection Fan Header Used Notes System Fan 1 PCI Zone Chassis Fan System Fan 2 HDD Cage Fan System Fan 3 Rear Chassis Fan

8 Side 2 Install Tool-less CD-ROM or DVD-ROM Drive · Side 2 16 Install Rack Mount Kit (Optional) If you intend to configure your server as ... 3 2 1 Remove EMI shield from 5.25-inch

Embed Size (px)

Citation preview

Side

2

16 Install Rack Mount Kit(Optional)

If you intend to configure your server as a pedestal system, disregard this step and proceed to Step 17.

If you intend to configure your server as a rack-mount system, go to the instructions that came with your Rack Mount Kit to complete your server assembly.

15 Install Feet

12

Note: Repeat above steps until all four feet are installed.Secure foot by inserting pin through the rubber foot.

Insert rubber foot into chassis hole.12

Note: This step applies to the pedestal version only. If you plan to configure your chassis as a rack mount system, go to Step 16.

10 Install Hot-SwapDrive Cage Kit(Optional)

If you intend to configure yourserver with SATA/SAS hot swaphard drives, go to the instructionsthat came with your drive cageupgrade kit to install the drive cage and hot-swap drives.

9b Install Tool-less Fixed Hard Drives(If installing a hot-swap drive cage,go to Step 10)

7 Install power and data cables to eachof the installed drives. The cablesroute through the oval opening atthe bottom of the drive cage.

7

8 Re-attach drive cage EMI shieldto chassis.

9 Tighten thumb screw.

8 9

Accessories and Order Codes

6-Drive SAS/SATA Hot Swap Cage without expander

6-Drive SAS/SATA Hot Swap Cagewith expander

Intel® Server Chassis Rack Mount Kit

IIntel® Server System SC5650BCDPProduct Maintenance Kit

AXX6DRV3GR1

AXX6DRV3GEXP1

APP3RACKIT

APPTPMKIT

Hot Swap Conversion Kit APPTHSDBKIT

1 Requires a Hot Swap Conversion Kit to integrate into the Intel® Server System SC5650BCDP.A complete list of accessories and spares can be found at: http://support.intel.com

Document TypeAvailable Documents

Technical Product SpecificationSpares and Configuration GuideSoftware and Drivers

ContentIn-depth technical informationSupported accessories and spares listUp-to-date firmware, driver and utility information

Additional Reference Documents available at: http://support.intel.com

18 Close System

2

1

1

Replace screws.2

Slide the side cover on chassis andlatch securely.

CAUTION: This chassis must be operated with the SIDE COVER installed to ensure proper cooling.

14 Remove Filler Panels

Remove the bezel filler panels for each drive you have installed. Release plastic tabs located at back side of bezel and pull out filler panels from front.

8 Install Tool-less CD-ROM or DVD-ROM Drive

1

2

321 Remove EMI shield from 5.25-inch device drive bay.

Make sure latch is in "unlock" position.

Line up holes in CD-ROM or DVD-ROM drive with holes in chassis.

Connect power (P5 or P6) cables and data cablesto rear of the CD-ROM or DVD-ROM

Move latch to "lock" position.

Insert CD-ROM or DVD-ROM drive into device drive bay.

An additional 4-pin IDE male-to-SATA 15 pin power cable adapter may be needed if the CD-ROM or DVD-ROM does not have a 4-pin power connector.

65

4

Data cables are included with the Intel® Server Board.

35

4

6DataPower

17 Install Front Bezel Assembly

Engage three clipsat right edge of chassis.

Rotate left sideof bezel assembly toward chassis.Snap two bezel tabsinto corresponding recesses at left edgeof chassis front panel.

1

3

2

3

1

1

1

2

3

Chassis Features and Components

A. Front PanelB. 5.25-inch Device Drive Bays (2)C. Hard Drive Cage Access DoorD. Door LockE. USB Ports (2)F. Fan Duct and System Fan (DP/WS/BRP configuration shown)G. Hard Drive Cage Retention Mechanism

H. Alternate external SCSI KnockoutI. Fixed Hard Drive Fan J. SC5650BCDP Mother BoardK. Padlock LoopL. PCI Card GuideM. External SCSI KnockoutN. Serial B port KnockoutO. Power Supply (fixed illustrated)P. A/C Power InQ. I/O ShieldR. PCI Add-in Board Slots

H

J

K

M

N

OP

R

Q

L

I

A

C

B

D

E

G

F

12 Install PCI Card Guide

1 Insert tabs on left side of PCI card guide into slots in chassis.

2 Swing PCI card guide into chassis until right-side blue tabs snap into place.

12

9a Install Tool-less Fixed Hard Drives (If installing a hot-swap drive cage, go to Step 10) (Continued...)

Insert fixed drive cage into chassis.1

1

2 Route power and data cablesthrough cable routing area at thebottom of the fixed drive cage.

3 Pull the drive latch forward for the drive bay you want to install a hard drive in.

Drive slots 1, 3, and 5 MUST be populated first. Failure to do socould result in thermal issueswithin chassis.

31

2

4

3

5

6

4 Insert fixed hard drive into drive bayuntil it stops. Ensure that the powerand data connector end of the hard driveis facing forward.

4

5 Push drive latch in to lock hard driveinto drive bay.

Install additional drives as necessary.6

5

Server Board S5500BCComponent Layout

See your Intel® ServerSystem S5500BCDP User's Guide for expanded component and connection information.

ICH10

Note: Refer to theTechnical ProductSpecification forDiagnostic LED

decoder list.

Diagnostic LEDs

DIM

M_A

2

DIM

M_A

1

DIM

M_B

2

DIM

M_B

1

DIM

M_E

1

DIM

M_E

2

DIM

M_D

1

DIM

M_D

2 CPU 1 Socket

CPU 2 Socket

Slot

7 (P

CI E

xpre

ss* x

8)

Slot

6 (P

CI E

xpre

ss* x

8, R

iser

Car

d)

Slot

5 (P

CI E

xpre

ss* x

4)

Slot

4 (P

CI 3

2/33

) RM

M3

Slot

3 (P

CI E

xpre

ss* x

4)NIC 2USB 9USB 8

NIC 1USB 7USB 6

VGA

Serial A

SYS FAN 3

SYS FAN 2

SATA 4

USB 2-3

USB 0-1

SATA 5

Serial B

HSBP_A

Main Power

CPU Power

BIT1LSB

DIMM FaultLEDs

Fron

t Pan

el H

eade

r

CPU 1 FAN

SYS FAN 1 CPU 2 FAN

DIMM Fault LEDs

IOH

P/S AUX

SATA RAIDKey

Status LEDID LED

BIT3BIT2

BIT6MSB

BIT4BIT5

BMC

SATA 0

SATA 1

SATA 3

SATA 2 BatteryIPMB_1

SATA SGPIO

13 Install PCI Add-in Boards

While holding the PCI add-inboard by its top edge or uppercorners, firmly press the add-inboard into the expansion slot.

3

Close the back panel PCI add-in board retention device.

4

4

From inside of chassis, press open the back panel PCI add-in boardretention device.

1

1

Remove the PCI slot shield bypressing the shield out fromthe inside of the chassis.

2

23

Front Panel Controls and Indicators

A. Power/Sleep LEDB. Power/Sleep ButtonC. NMI ButtonD. Reset ButtonE. NIC 1 Activity LEDF. NIC 2 Activity LEDG. Hard Drive Activity LEDH. Status LED

A

C

F

H

B

D

E

G

Reference19 Finishing Up

1. See your Intel® Server Board Quick Start User's Guide to connect your keyboard, mouse, video and other I/O cables.

2. Connect the AC power cable last.

CAUTION: Power supply requires a 16-gauge power cord.

20 Install SoftwareBIOS, Drivers, and OperatingSystem Install

A. Confirm BIOS Version: Look on theServer/System Management screen in the BIOSSetup Utility to determine the installed BIOSversion. Compare this to the versions at: http://support.intel.com/support/motherboards/server/S5500BC/If new versions are available, update the BIOSon your server. See the User Guide on theIntel® Server Deployment Toolkit CD forupdate instructions.B. Configure your RAID Controller: Use the instructions provided with theRAID controller.C. Install your Operating System: Use the instructions provided with the RAIDcontroller and with the operating system.

D. Install Operating System Drivers: With the operating system running, insert theIntel® Server Deployment Toolkit CD. If usinga Microsoft* Windows*operating system,the Express Installer will autorun and allowyou to select the appropriate drivers to install.On other operating systems, browse the CDfolders to locate and install the driver files.

11 Complete Server Board Connections

See your Intel® Server Board Quick Start User's Guide or the User Guide for server board cable connections.

Fan Connection Fan Header Used Notes System Fan 1 PCI Zone Chassis Fan System Fan 2 HDD Cage Fan System Fan 3 Rear Chassis Fan