FINAL ASSEMBLY 8910/20 7818E010 PLATE,I-COMM 1 65000550 7804M205 1 17200012 CONTACT, N.O. 2 17200013 CONTACT, N.C. 1 LABEL, PORTUGUESE, ELECTRICAL SET, 8900 7818M330 53850511 3 2 51000001 FUSE,.5AMP,600V,TIME DELAY + 4 1 51000002 FUSE,1AMP,250V,TIME DELAY 5 1 51000003 FUSE HOLDER,2POLE,600V,30A + 6 2 51000004 FUSE HOLDER,1POLE,300V,12A + 7 1 51000005 FUSE,2AMP,250V,TIME DELAY 9 12 13 14 15 1 73100019 TERMINAL,END BAR,FUSE HOLDER 16 2 73100024 TERMINAL,END STOP,SCREWLESS 17 30 73250004 TIE,CABLE,NYLON,4",18# 18 1 73550029 XFMR,100VA,208/230/460V:24/115 19 4 74100004 WSHR,LOCK,INT/EXT,#10,ZNC 20 2 73100087 TERMINAL,WA,CAGE,20A,3HOLE,GND 21 1 73100086 TERMINAL,WA,CAGE,20A,3HOLE,BAR 22 1 73100082 TERMINAL,WA,CAGE,20A,JUMP,3P 23 11 73100085 TERMINAL,WA,CAGE,20A,3HOLE 24 1 65100022 9999E050 CONTROLLER, I-COMM 25 1 65700006 POWER SUPPLY,DIN,24VDC,18W 26 4 71300005 STANDOFF,NYLON,PCB,3/16X1 27 1 51950067 9999M028 DISPLAY,LCD,2-LINE,W/ CONN 28 1 38120006 DIN RAIL,LOW-PROFILE,6-1/2" 29 2 71300009 STANDOFF,NYLON,PCB,0.1"X7/16 30 1 52000031 HARN,WIRE KIT,CBOX,8900 1 31 32 1 12200068 7804M204 BACKPANEL,PNCH,14X16,W/FLNG 1 53850492 9999M027 LABEL, I-COMM TERMINALS OR 2 51000023 FUSE,1AMP,600V,CC,TIME DELAY 400-575V 200-240V 8 67850015 SCR,PHLP,DR/TP,#8X1/2 10 2 67850065 SCR,FHWH,#8X9/16BLK K-LATH 11 SOCKET, RELAY, 1-POLE, 250VAC, 10AMP *DIN RAIL,LOW-PROFILE,3-1/2" (ALSO FOR WIRELESS OPTION) ALARM, AUDIBLE, 24AC/DC , 22.5MM (NOT SHOWN) LABEL, AREA DETECTOR, ALARM (NOT SHOWN) HARN, KIT, I-ZONE (NOT SHOWN) HARN,WIRE KIT,WARN DVC RLY,ICM WARNING DEVICE RELAY I-ZONE OPTIONAL OPTIONAL RADIO CONTROL OPTIONAL LOOP CONTROLLER 56 AND 54 AND 52 AND 53 55 51 1 1 1 1 1 1 1 17500010 52000035 11050007 53850402 70350002 66450014 38120029 52000036 1 59 58 60 2" 2" 1" 74000014 74000019 74000020 RLY,SPDT,24VDC,10AMP CTRLR,IND LOOP,DUAL,12/24V 9999M011 VELCRO, PSA, LOOP,BLACK, 1" VELCRO, PSA, LOOP, BLACK, 2" VELCRO, PSA, HOOK, BLACK, 2" 81 81 1 *TERMINAL,END STOP,SCREWLESS (ALSO FOR WIRELESS OPTION) AND 2 73100024 DWG. NO. 1 1 17000015 CONTACTOR, REVERSING 9-AMP W/ INTERLOCK 2 1 16660017 RELAY, OVERLOAD 1.8-2.6A OR 1 16660016 RELAY, OVERLOAD 2.6-3.7A OR 1 16660019 RELAY, OVERLOAD 3.8-5.5A OR 1 16660018 RELAY, OVERLOAD 1.2-1.8A CONTACTOR, REVERSING 12-AMP W/ INTERLOCK OR 1 17000016 OR 1 16660020 RELAY, OVERLOAD 5.5-8.0A LABEL, ENGLISH, ELECTRICAL SET, 8900 7818M329 53850502 LABEL, SPANISH, ELECTRICAL SET, 8900 1 53850507 7818M331 81 1 1 38120027 DIN RAIL,LOW-PROFILE,5.25"LONG OR 1 73550030 XFMR,100VA,380/415/575V:24/115 208-240, 460-480V 400, 415 & 575V 33 34 35 36 37 SWITCH, E-STOP SWITCH, PB, FLUSH, BLACK SWITCH, PB, FLUSH, GREEN 1 1 1 72700085 72700006 72700104 LABEL, NAMEPLATE 1 53850430 8804M598 ENCLOSURE, MACHINED 16x14x8, WITH WINDOW 1 43750129 7818M325 82 82 82 53850508 7818M328 LABEL, CBOX, 8900, ENCLOSURE 1 53850500 7818M326 LABEL, CBOX, 8900, ENCLOSURE 1 53850510 7818M327 LABEL, PORTUGUESE, CBOX, 8900, ENCLOSURE 1 38 CONNECTOR, CONDUIT, 1", LIQUID TIGHT 1 16960001 7818-E-021 REV. G PRIOR PART # MODEL NUMBER REV SHEET DWG NO DATE ISSUED C BY APPROVED DATE ECN DESCRIPTION REVISION HISTORY REV 1 A C B D A B C D 2 3 4 5 6 7 8 8 7 6 5 4 3 1 REV DWG NO TITLE SIZE D SHEET SCALE DO NOT SCALE DRAWING DATE DATE DATE CHECKED BY APPROVED BY DRAWN BY REF INITIAL ECN OVER 0 INCH TOLERANCES UP TO 0.125 5 1.25 40 80 15 0.25 1.25 15 40 5 FINISH +/- 1 DEG 80 ANGLES 0.125 0.25 0.010 0.040 0.060 0.100 0.125 0.020 0.030 + / - 0.005 MM-DD-YY NEXT ASSEMBLY PARTS LIST / MATERIAL ITEM PART NO. QTY DESCRIPTION RITE-HITE DOORS INC. 7818E032 7818E032 1"=1" H H TRAKLINE - ROLL & FOLD CONTROL BOX LAYOUT UNIVERSAL CONTROLLER 8910/8920/8920PL 1740 RPB 12/27/2005 4994 2/20/2006 2005 G ADD ACTIVATION OPTIONS 6825 1/22/2014 TAH H BEA RADIO CONTROLS 6893 7/15/2014 TAH F MULTIPLE BUTTON TRANSMITTERS 6520 6/14/2012 TAH RCVR,BEA,433,12-24V,1FN TRANS,BEA,433,3BTN OR A/R 73750079 A/R 73750078 OR 57 A/R 1 73750080 66250020 TRANS,BEA,433,2BTN TRANS,BEA,433,1BTN HARN,DUAL LOOP CTRLR,UNIV AND 1 52000067 9999M042 WIRELESS ACTIVATION OPTION CTRLR,WIRELESS ACT,BTR,12-24V AND 61 1 17500025 *SEE INDUCTION LOOP OPTION BELOW OR 1 65700007 POWER SUPPLY,DIN,24VDC,30W,CG DC POWER CONSUMPTION > 22W DC POWER CONSUMPTION <= 22W AND 1 52000068 HARN,WIRELESS HOST,ICOMMII 9999M043 39 SCR,GROUND,#10-32X3/8 1 67850177 40 LABEL,GROUND 1 53850048

8 7 6 5 4 3 1 H - Rite-Hite

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 8 7 6 5 4 3 1 H - Rite-Hite

FINAL ASSEMBLY

8910/207818E010

PLATE,I-COMM1 65000550 7804M205

1 17200012 CONTACT, N.O.

2 17200013 CONTACT, N.C.

1 LABEL, PORTUGUESE, ELECTRICAL SET, 89007818M33053850511

3 2 51000001 FUSE,.5AMP,600V,TIME DELAY +

4 1 51000002 FUSE,1AMP,250V,TIME DELAY

5 1 51000003 FUSE HOLDER,2POLE,600V,30A +

6 2 51000004 FUSE HOLDER,1POLE,300V,12A +

7 1 51000005 FUSE,2AMP,250V,TIME DELAY

9

12

13

14

15 1 73100019 TERMINAL,END BAR,FUSE HOLDER

16 2 73100024 TERMINAL,END STOP,SCREWLESS

17 30 73250004 TIE,CABLE,NYLON,4",18#

18 1 73550029 XFMR,100VA,208/230/460V:24/115

19 4 74100004 WSHR,LOCK,INT/EXT,#10,ZNC

20 2 73100087 TERMINAL,WA,CAGE,20A,3HOLE,GND

21 1 73100086 TERMINAL,WA,CAGE,20A,3HOLE,BAR

22 1 73100082 TERMINAL,WA,CAGE,20A,JUMP,3P

23 11 73100085 TERMINAL,WA,CAGE,20A,3HOLE

24 1 65100022 9999E050 CONTROLLER, I-COMM

25 1 65700006 POWER SUPPLY,DIN,24VDC,18W

26 4 71300005 STANDOFF,NYLON,PCB,3/16X1

27 1 51950067 9999M028 DISPLAY,LCD,2-LINE,W/ CONN

28 1 38120006 DIN RAIL,LOW-PROFILE,6-1/2"

29 2 71300009 STANDOFF,NYLON,PCB,0.1"X7/16

30 1 52000031 HARN,WIRE KIT,CBOX,89001

31

32

1 12200068 7804M204 BACKPANEL,PNCH,14X16,W/FLNG

1 53850492 9999M027 LABEL, I-COMM TERMINALS

OR 2 51000023 FUSE,1AMP,600V,CC,TIME DELAY

400-575V

200-240V

8 67850015 SCR,PHLP,DR/TP,#8X1/2

10 2 67850065 SCR,FHWH,#8X9/16BLK K-LATH

11

� �

SOCKET, RELAY, 1-POLE, 250VAC, 10AMP

*DIN RAIL,LOW-PROFILE,3-1/2" (ALSO FOR WIRELESS OPTION)

ALARM, AUDIBLE, 24AC/DC , 22.5MM (NOT SHOWN)

LABEL, AREA DETECTOR, ALARM (NOT SHOWN)

HARN, KIT, I-ZONE (NOT SHOWN)

HARN,WIRE KIT,WARN DVC RLY,ICM

� �

WARNING DEVICE RELAY

I-ZONE OPTIONAL

OPTIONAL RADIO CONTROL

OPTIONAL LOOP CONTROLLER

56

AND

54

AND

52

AND

53

55

51

1

1

1

1

1

1

1 17500010

52000035

11050007

53850402

70350002

66450014

38120029

520000361

59

58

60

2"

2"

1" 74000014

74000019

74000020

RLY,SPDT,24VDC,10AMP

CTRLR,IND LOOP,DUAL,12/24V

9999M011

VELCRO, PSA, LOOP,BLACK, 1"

VELCRO, PSA, LOOP, BLACK, 2"

VELCRO, PSA, HOOK, BLACK, 2"

81

81 1

*TERMINAL,END STOP,SCREWLESS (ALSO FOR WIRELESS OPTION)AND 2 73100024

DWG. NO.

1 1 17000015 CONTACTOR, REVERSING 9-AMP W/ INTERLOCK

2 1 16660017 RELAY, OVERLOAD 1.8-2.6A

OR 1 16660016 RELAY, OVERLOAD 2.6-3.7A

OR 1 16660019 RELAY, OVERLOAD 3.8-5.5A

OR 1 16660018 RELAY, OVERLOAD 1.2-1.8A

CONTACTOR, REVERSING 12-AMP W/ INTERLOCKOR 1 17000016

OR 1 16660020 RELAY, OVERLOAD 5.5-8.0A

LABEL, ENGLISH, ELECTRICAL SET, 89007818M32953850502

LABEL, SPANISH, ELECTRICAL SET, 89001 53850507 7818M331

81 1

1 38120027 DIN RAIL,LOW-PROFILE,5.25"LONG

OR 1 73550030 XFMR,100VA,380/415/575V:24/115

208-240, 460-480V

400, 415 & 575V

33

34

35

36

37

SWITCH, E-STOP

SWITCH, PB, FLUSH, BLACK

SWITCH, PB, FLUSH, GREEN1

1

1

72700085

72700006

72700104

LABEL, NAMEPLATE1 53850430 8804M598

ENCLOSURE, MACHINED 16x14x8, WITH WINDOW1 43750129 7818M325

82

82

82 53850508 7818M328 LABEL, CBOX, 8900, ENCLOSURE1

53850500 7818M326 LABEL, CBOX, 8900, ENCLOSURE1

53850510 7818M327 LABEL, PORTUGUESE, CBOX, 8900, ENCLOSURE1

38 CONNECTOR, CONDUIT, 1", LIQUID TIGHT1 16960001

7818-E-021 REV. GPRIOR

PART #

MODEL NUMBER

REVSHEETDWG NO

DATE ISSUED

R

C

BY APPROVEDDATEECNDESCRIPTION

REVISION HISTORY

REV

1

A

C

B

D

A

B

C

D

2345678

8 7 6 5 4 3 1

REVDWG NO

TITLE

SIZE

DSHEETSCALE

DO NOT SCALE DRAWING

DATE

DATE

DATE

CHECKED BY

APPROVED BY

DRAWN BY

REF

INITIAL ECN

OVER

0

INCH TOLERANCES

UP TO

0.125

5

1.25

40

80

15

0.25

1.25

15

40

5

FINISH

+/- 1 DEG

80

ANGLES

0.125 0.25 0.010

0.040

0.060

0.100

0.125

0.020

0.030

+ / -

0.005MM-DD-YY

NEXT ASSEMBLY

PARTS LIST / MATERIAL

ITEM PART NO.QTY DESCRIPTION

RITE-HITE DOORS INC.

7818E032

7818E032

1"=1"

H

H

TRAKLINE - ROLL & FOLD

CONTROL BOX LAYOUT

UNIVERSAL CONTROLLER

8910/8920/8920PL

1740

RPB 12/27/2005

4994

2/20/20062005

G ADD ACTIVATION OPTIONS 6825 1/22/2014 TAH

H BEA RADIO CONTROLS 6893 7/15/2014 TAH

F MULTIPLE BUTTON TRANSMITTERS 6520 6/14/2012 TAH

RCVR,BEA,433,12-24V,1FN

TRANS,BEA,433,3BTN

OR A/R 73750079

A/R 73750078

OR

57

A/R

1

73750080

66250020

TRANS,BEA,433,2BTN

TRANS,BEA,433,1BTN

HARN,DUAL LOOP CTRLR,UNIVAND 1 52000067 9999M042

WIRELESS ACTIVATION OPTION

CTRLR,WIRELESS ACT,BTR,12-24V

AND

61 1 17500025

*SEE INDUCTION LOOP OPTION BELOW

OR 1 65700007 POWER SUPPLY,DIN,24VDC,30W,CGDC POWER CONSUMPTION > 22W

DC POWER CONSUMPTION <= 22W

AND 1 52000068 HARN,WIRELESS HOST,ICOMMII9999M043

39 SCR,GROUND,#10-32X3/81 67850177

40 LABEL,GROUND1 53850048

Page 2: 8 7 6 5 4 3 1 H - Rite-Hite

TORQUE INSTRUCTIONS:

1. TIGHTEN TO RECOMMENDED MIN TORQUE SETTING.

2. PULL TEST ALL WIRES.3. IF WIRE PULLS OUT, TORQUE AGAIN TO MINIMUM VALUE, GENTLY HAND TIGHTEN UNTIL

WIRE CANNOT BE PULLED LOOSE.

SCREW TERMINAL MIN TORQUE SETTING

INSTALLED OPTIONAL COMPONENTS

� WIRELESS ACTIVATION HOST

� INDUCTION LOOP CONTROLLER

� INTERLOCK WIRING

� RADIO CONTROL

� ANNOUNCE OPTION (K8)

� I-Zone

RHC# _______________

SERIAL# _______________

NOTE: OPTIONAL DEVICES WILL ONLY

BE CHECKED ON THE WIRING DIAGRAM

INCLUDED WITH THE CONTROL BOX.

NOTE: ALL D.C. CONTROL (24 VOLTS) WIRES

ARE BLUE. ALL A.C. (24 VAC) CONTROL

WIRES ARE RED. ALL CONTROL CIRCUITS

ARE GROUND REFERENCED.

ALL WIRE IS 18 AWG UNLESS NOTED.

WIRE HARNESS SHOULD MEET THE FOLLOWING

SPECIFICATIONS:

UL R/C (AVLV2) / CSA CERT.

AWM/MTW, 18 GAGE MIN. UNLESS NOTED.

80°C MIN. 600V

ABOVE FOR PROPER TAPS.SEE TRANSFORMER SETTINGS

102.372.10380-415(1 HP)

8920(1 HP OR

1.5 HP)

(2 HP)

8920PL

575

440-480

380-415

230-240

2.45

3.17

6.33

3.64

2.62

3.40

3.90

6.77

15

15

15

15

> 144 SQ. FT.

575

208

440-480

230-240

380-415

1.83

1.50

6.33

2.10

3.65

=< 144 SQ. FT.208 SIZE

208 SIZE

575

440-480

3.65

4.20

1.83

1.50

2.05

1.68

6.81

4.09

2.37

10

10

15

10

10

4.13

4.68

2.05

1.68

10

10

10

10

BACKPANEL P/N: 1226.XXXX

CONTROL BOX P/N: 1731.XXXX (OPTIONAL)

F4

CB1

8910

(1 HP)

8920

8910

MODEL

MODEL

1.5 HP)

(1 HP OR

(2 HP)

8920PL

USE ONLY RECOMMENDED SETTING

TORQUE

COIL OHMS

COIL VOLTAGE

6.9 AMPS208

SUPPLIED BY THE END USER AND COMPLY

BE BASED ON INTERMITTENT DUTY.

CODES. SIZING FOR PROTECTIVE DEVICES MAY

WITH ALL NATIONAL AND LOCAL ELECTRICAL

NOTE: BRANCH CIRCUIT PROTECTION MUST BE

VOLTAGE

208

230-240

3.65

3.65

F.L.A.MOTOR SERVICE

AMPS

4.13

4.09

F.L.A.TOTAL

10

10

6.3 AMPS

3.6 AMPS

2.5 AMPS

3.2 AMPS

10 Nm

BRANCH CIRCUIT PROTECTION

BRAKE RATINGS

328 OHMS

7.5 FT LB

105 VDC

575

440-480

230-240

380-415

FROM END USER

SUPPLIED DISCONNECT(SEE TABLE)

USE COPPER CONDUCTORS RATED AT 60°C OR HIGHER

INCOMING POWER

L2

L1

L3

PE PE

L3BK

BK

BK

L1

L2

#14 AWG

2.1 AMPS380-415

1.8 AMPS

1.5 AMPS

3.8 AMPS

3.7 AMPS

2.1 AMPS

1.5 AMPS

1.8 AMPS

4.2 AMPS> 144 SQ. FT.

575

440-480

230-240

380-415

=< 144 SQ. FT.208 SIZE

208 SIZE

575

440-480

SETTING

3.8 AMPS

3.7 AMPS

OVERLOAD RELAY SETTING

208

230-240

VOLTAGE

380-415

208-240

380-575

1 AMP

.5 AMP CC

1 AMP CC

BU

34

OPEN/RESET P.B. (X12)

MC1 = COMPONENT NAME9695MC2

VERIFY THAT THIS DRAWING HAS NOT BEEN SUPERCEDED BY NEWER REVISION. ABOVE APPLIES ONLY WHEN DRAWING IS CURRENT.

7818-E-010 REV. K

THIS DRAWING COVERS DOORS CONFIGURED AFTER 2-20-006

#14 AWG#14 AWG

BK

BK

GN/YE

BKV

MOTOR GND

MOTOR Ø1U

X1

T1

MOTOR Ø3

MOTOR Ø2W

T2

T3

14

PRIOR

SCOPE

OVERLOAD RELAY13O/L 1

T1 L1

T3

T2

L3

L2

= ASSIGNED TERMINATION NUMBER

= LOCAL TERMINATION NUMBER

= OPPOSITE END OF WIRE

= BOLD LINE = A.C. COMMON

= DASHED LINE = OPTIONAL EQUIPMENT

ALL BLACK WIRES ARE AT POTENTIALLYCAUTION:

T2T3 T1

L3 L1L2

T3

L3

LETHAL VOLTAGES.

T1T2

L1L2

5

35

35

A1

#14 AWG

GN/YEF4

0.1 KVA

TRANSFORMER

MC1

WH

BRAKE

BRAKEB1

B2

COMMON (OPT.)N

NX1

BK

B1

14

BK

BK

F3H4

T1 H3

H2

X2

X3

13

F1

A2

MC1A2

OPEN

CLOSE

MC2

FUSED 24VAC

FUSED 120VAC

H1

F1

F2

BK

N

RD

X1 WH

BK

RD

BK

BK

ELECTRICAL KEY:

= TERMINAL JUMPER

= TERMINAL BLOCK

MC1 MC2

5

A1

208

380

415

575

F1

F2

F3

USE ONLY RECOMMENDED VALUES

DEVICE

LINE VOLTAGE

220-240

440-480

LINE VOLTAGE

STANDARD TRANSFORMER SETTINGS

OPTIONAL TRANSFORMER SETTINGS

CURRENT RATING

380-575

208-240

-

.5 AMP CC

1 AMP CC

2 AMP

FOR REPLACEMENT

CONTROL BOX FUSING

VOLTAGE

- 1 AMP

H1-H2

H1-H3

H1-H4

TAPS

H1-H2

H1-H4

H1-H3

TAPS

CONTACTORDISCONNECT

INTERLOCKINVERTEROVERLOADTRANSFORMER

TERMINALSRELAYS

PLC (RH/AB)

COMPONENT

6

66666

55

4/2

20

2020202020

1212

10/5

(IN-LBS)

TORQUE SETTING

DRIVER

BU J3-3 J3-4

I-ZONE ALARM

(OPTIONAL)

La N J3-2 BU

POWER SUPPLY

PS1 +24V

0V

L

N

PE

IS2 2 1

RD

JOG P.B.

E-STOP

RD

96 1 AC2

RD

X0-

OP

EN

L/S

X1-

CLO

SE

L/S

X2-

AC

TIV

AT

ION

X3-

AC

TIV

AT

ION

X4-

NO

T U

SE

D

X5-

TO

GG

LE IN

PU

T

X6-

AC

TIV

AT

ION

X7-

AC

TIV

AT

ION

X8-

I-Z

ON

E 1

X9-

I-Z

ON

E 2

X10

-PH

OT

OE

YE

1

X11

-PH

OT

OE

YE

2

DC

-24V

DC

OV

-0V

DC

LP2-LOOP WIRE

LP1-LOOP WIRE

YDC3-DC OUTPUT

YDC2-DC OUTPUT

YDC1-DC OUTPUT

YDC0-DC OUTPUT

IR-INTERRUPT

AC-24V AC

N-NEUTRAL

N-NEUTRAL

AC-24V AC

AC-24V AC

K3N-K3 COMMON

IS1-FAULT/JOG SRC

IS2-FAULT/JOG RTN

K2-RELAY K2 OUT

K2N-K2 COMMON

K3-RELAY K3 OUT

J4-3

J4-2

J4-4

J4-5

J4-6

J4-7

J4-8

PART #

MODEL NUMBER

REVSHEETDWG NO

DATE ISSUED

R

C

BY APPROVEDDATEECNDESCRIPTION

REVISION HISTORY

REV

1

A

C

B

D

A

B

C

D

2345678

8 7 6 5 4 3 1

REVDWG NO

TITLE

SIZE

DSHEETSCALE

DO NOT SCALE DRAWING

DATE

DATE

DATE

CHECKED BY

APPROVED BY

DRAWN BY

REF

INITIAL ECN

OVER

0

INCH TOLERANCES

UP TO

0.125

5

1.25

40

80

15

0.25

1.25

15

40

5

FINISH

+/- 1 DEG

80

ANGLES

0.125 0.25 0.010

0.040

0.060

0.100

0.125

0.020

0.030

+ / -

0.005MM-DD-YY

NEXT ASSEMBLY

PARTS LIST / MATERIAL

ITEM PART NO.QTY DESCRIPTION

RITE-HITE DOORS INC.

7818E030

7818E030

1 of 1

1 of 1

9"=1'

C

C

TRAKLINE - ROLL & FOLD

WIRING DIAGRAM

i-COMM

8910/8920/8920PL

SEE ABOVE

RPB 10/13/2005

4994

2/20/20062005

A CORRECT J3 ER. DEPICTION 5065 7/21/2006 NCN

B switch push button 3, 4 6166 9/8/2010 MDB

C ADD ACTIVATION OPTIONS 6825 1/22/2014 TAH

JP1-JUMPER 1-2 & 3-4

USE SHUNTS PROVIDED

CONNECTOR TABLE

THIS TABLE SHOWS THE FUNCTION OF EACH OF

THE CONNECTORS ON THE UNIVERSAL CONTROLLER. THE VOLTAGES LISTED FOR EACH PIN ASSUME THAT EITHER THE INPUT OR OUTPUT

IS ACTIVATED.

CONN. PIN # FUNCTION VOLTAGE

J3

1 UNUSED OUTPUT 0 VDC

2 I-ZONE ALARM OUT 0 VDC

3 DC POWER OUT 24 VDC

4 RESET INPUT (X12) 24 VDC

J4

1 UNUSED

2 DC COMMON INPUT 0 VDC

3 DC POWER INPUT 24 VDC

4 24V AC INPUT 24 VAC

5 24V AC COMMON (N) 24 VAC

6 OPEN/CLOSE COMMON N

7 CLOSE OUTPUT (K1) 24 VAC

8 OPEN OUTPUT (K0) 24 VAC

J5

1 LOOP INPUT 2

2 LOOP INPUT 1

3 DC POWER OUT 24 VDC

4 DC COMMON OUT 24 VDC

5 DC POWER OUT 24 VDC

6 LOOP INPUT (X13) 24 VDC

K65 1

ANNOUNCE

(DC RLY.) OPTIONAL

GN/YE

ANNOUNCE STROBE (OPT.)

STB120VAC (OPT.)

4 3

K6

COMMON (OPT.)

5 TWISTS/FT. MIN

IND

UC

TION

LOO

PC

ON

TR

OLLE

R1

32

54

76

108

9

GN/YE 11

INDUCTION

LOOP A

INDUCTIONLOOP B

LPA

LPB

J5-3

J5-4

24VDC IN

0VDC IN

RELAY 1 (DC)

RELAY 1 (X13)

J5-5

J5-6

RD

BK

VT

GN

OPTIONAL WIRELESS ACTIVATION

0V

DC

X6

6

24

V

70V

8

CL

SG

9RE

10

BK

WY

OP

EN

2

CL

S

3

ST

OP

4

O/C

5

CO

M

AC

TIV

ATO

R

PO

WE

RS

AFE

TY

RF Com

Fault

Rem

otePairing

WIR

ELE

SS

HO

ST

SEE 7818E035 FOR PAIRING INSTRUCTIONS

12

34

5

67

89

10

Page 3: 8 7 6 5 4 3 1 H - Rite-Hite

WH

GN

BK

=< 144 SQ. FT.

> 144 SQ. FT.

440-480

8920PL

(2 HP)440-480

380-415

575

230-240

208

575

1.5 HP)

(1 HP OR8920

380-415

230-240

208 SIZE

208 SIZE

575

1.83

3.17

3.64

2.45

1.50

6.33

6.33

4.20

2.10

3.65

1.50

3.65

NOTE: BRANCH CIRCUIT PROTECTION

MUST BE SUPPLIED BY THE END USER

BRANCH CIRCUIT PROTECTION

LOCAL ELECTRICAL CODES. SIZING FOR

PROTECTIVE DEVICES MAY BE BASED

AND COMPLY WITH ALL NATIONAL AND

ON INTERMITTENT DUTY.

(1 HP)

8910

MODEL

230-240

380-415

440-480

VOLTAGE

208

MOTOR

3.65

2.10

1.83

3.65

F.L.A.

GNYE

BLK #3

BLK #1

BLK #2

BRAKE

OPEN LIMIT

BLK #4

BLK #5

UPPER REVERSING

OPTIONAL - THRU-BEAM

STANDARD - RETROREFECTIVE

OPTIONAL - THRU-BEAM

STANDARD - RETROREFECTIVE

ARE SET TO "LIGHT OPERATE".NOTE: ALL REVERSING PHOTOEYES

PHOTO-EYE

LOWER REVERSING

BK

CLOSE LIMIT

BU 1BU 1 BU

OG

BR

PHOTO-EYE

OG 4

3

2

BR

BK

4 WH

2

3 BR

OG

3BR

2

1BU

BK

4OG

BR3

2

1 BU

BK

4 WH

GN11 GN

3ø INCOMING POWER FROM END

USER SUPPLIED DISCONNECT.

USE COPPER CONDUCTORS RATED

AT 60°C OR HIGHER

NOTE:

USE ONLY FACTORY SUPPLIED CABLE

FOR MOTOR, PHOTOEYES, & LIMIT

SWITCHES. CLIP

4

3

1

2

4

3

1

2

GNYE

BLK #3

BLK #2

BLK #1

16 GA. / 7 CONDUCTOR SHIELDED CABLE

1

2

1

2

BLK #4

BLK #5

GNYE

BLK #3

BLK #4

BLK #2

BLK #1

BLK #6

BLK #5

L1

B2 ** NOTE: THE RD & BK

WIRES IN TERMINALS W & V

MAY BE REVERSED TO

CHANGE MOTOR ROTATION.

N EUROPEAN ONLY

L2

L3

PE

V

U

**W

B1

(LESS THAN 30 VOLTS)

LOW VOLTAGE TERMINALS

HIGH VOLTAGE TERMINALS

(GREATER THAN 100 VOLTS)

18 GA. / 2 CONDUCTOR CABLE

BU

BR

22 GA. / 5 CONDUCTOR CABLE

18 GA. / 3 CONDUCTOR CABLE

3

2

3

2

WH

BK

WH

BK

BU

1

2

1

2

WH

BR

OG

BK

2

1

2

1

WH OR RD

BK

BU

BR

1

2

BK1

WH2

LOWER REVERSING PHOTO-EYE

THRU-BEAM EMITTER OPTIONAL

UPPER REVERSING PHOTO-EYE

THRU-BEAM EMITTER OPTIONAL

AC* 24 VAC

N* AC COMMON

X10* P.E. INPUT

X11* P.E. INPUT

N* AC COMMON

AC* 24 VAC

DC* DC POWER

DC* DC POWER

X0* OPEN L.S.

X1* CLOSE L.S.

* NOTE: TERMINALS MARKED

WITH AN (*) ARE LOACTED

ON THE i-COMM

CONTROLLER.

PART #

MODEL NUMBER

REVSHEETDWG NO

DATE ISSUED

R

C

BY APPROVEDDATEECNDESCRIPTION

REVISION HISTORY

REV

1

A

C

B

D

A

B

C

D

2345678

8 7 6 5 4 3 1

REVDWG NO

TITLE

SIZE

DSHEETSCALE

DO NOT SCALE DRAWING

DATE

DATE

DATE

CHECKED BY

APPROVED BY

DRAWN BY

REF

INITIAL ECN

OVER

0

INCH TOLERANCES

UP TO

0.125

5

1.25

40

80

15

0.25

1.25

15

40

5

FINISH

+/- 1 DEG

80

ANGLES

0.125 0.25 0.010

0.040

0.060

0.100

0.125

0.020

0.030

+ / -

0.005MM-DD-YY

NEXT ASSEMBLY

PARTS LIST / MATERIAL

ITEM PART NO.QTY DESCRIPTION

RITE-HITE DOORS INC.

7818E034

7818E034

9"=1'

B

B

TRAKLINE - ROLL & FOLD-ENCLOSURE

EXTERNAL FIELD WIRING DIAGRAM

i-COMM CONTROLS

8910/8920/8920PL

RPB 1/9/2006

4994

2/20/20062006

A ADDED SHIELDED MOTOR CABLE 6828 2/18/2014 JJS

B ADDED RING CONNECTOR 6887 6/27/2014 JJS

VERIFY THAT THIS DRAWING HAS NOT BEEN SUPERCEDED BY NEWER REVISION. ABOVE APPLIES

ONLY WHEN DRAWING IS CURRENT.

7818-E-009 REV. KPRIOR

THIS DRAWING COVERS DOORS CONFIGURED AFTER 2-20-2006

SCOPE

TRIM FOIL SHEATH

DRN/BRD DRN/BRD DRN/BRD TERMINATED

ON BACK PANEL

Page 4: 8 7 6 5 4 3 1 H - Rite-Hite

PART #

MODEL NUMBER

REVSHEETDWG NO

DATE ISSUED

R

C

R

BY APPROVEDDATEECNDESCRIPTION

REVISION HISTORY

REV

1

A

C

B

D

A

B

C

D

2345678

8 7 6 5 4 3 1

REVDWG NO

TITLE

SIZE

DSHEETSCALE

DO NOT SCALE DRAWING

DATE

DATE

DATE

CHECKED BY

APPROVED BY

DRAWN BY

REF

INITIAL ECN

OVER

0

INCH TOLERANCES

UP TO

0.125

5

1.25

40

80

15

0.25

1.25

15

40

5

FINISH

+/- 1 DEG

80

ANGLES

0.125 0.25 0.010

0.040

0.060

0.100

0.125

0.020

0.030

+ / -

0.005MM-DD-YY

NEXT ASSEMBLY

PARTS LIST / MATERIAL

ITEM PART NO.QTY DESCRIPTION

RITE-HITE DOORS INC.

7818E035

7818E035

RITE-HITEDOORS INC.

9"=1'

A

A

TRAKLINE SERIES

ACTIVATION WIRING

8900

TAH 1/22/2014

6825

1/22/20142014

A BEA RADIO CONTROLS 6893 7/15/2014 TAH

FINAL ASSEMBLY

NOTES

This drawing assumes input functions are set to factory defaults. Consult i-Comm manual for details. WARNING - never connect motion sensors to a toggle input.

Terminals "X6", "X7" are automatic reclose.

Terminal X7 on the motor terminal strip can be used for activation devices such as motion sensors and pull cords.

Terminals "DC" are DC common for inputs.

**For true toggle operation use terminal "X5".

(Pull cords, push button or radio controls only.)

***For Reverse hold open connect sensors to UNUSED input.

(i.e. X3, X6, or X7 and assign that input a function of "6" in the i-COMM menu. Multiple sensors can be connected in parallel.

Consult i-COMM manual and/or Door manual for additional instructions.

Control Box

Warning Device Strobe

120VAC U.L. Listed .30 Amp Max

Additonal Relay Required

N

STB

Wire

Beacon/Strobe

Wire

BEA Motion Sensors

Presence Sensor

X6***

DC

X3***

DC

Control Box

Control Box

Wire Each device as shown.

Control Box

WH

GN

X6**

DC

STB

Switch

SW

SW

N

DC

N

AC

Wire

Wire

Alarm

Photoeye

BK

BU

BN

BEA MATRIXINDUCTION LOOP

PHOTOEYESPUSHBUTTONS & PULL-CORDS

120V STROBE 120VAC ALARM

Warning Device Strobe

120VAC U.L. Listed .30 Amp Max

Additonal Relay Required

X6***

DC

BEA IS40 Motion/Presence Sensor

4-GN

3-WH

5-YE

X3***

DC

GRN/BLK

YE/BLK

Presence Sensor

DC

X3***

BN

BU GN

WH

YE

Set X3 to a value of 6-Reverse

IS-40 Hold OpenSet X3 to a value of (6-Reverse)

WH/BLK

not used

not usedSet X3 to a value of 6-Reverse

BN

BU

not used

not used

not used

CONTROL BOX WIRING

PREANNOUNCE RELAY

STB3

CR31

4

5DC YDC_

F1 or L

See X7 noteSee X7 note

See X7 note

See X7 note

Control Box Control Box

0V

DC

0V

DC

Sensor

BK

RD

BEA - Falcon, Eagle,

MS08 BEA - DK-12US Control Box

0V

DC

BEA - IS-40

2-BK

1-RD

Control Box

0V

DC

Sensor

BK

RD

BEA - IRIS

BK

RD

Retroreflective or Thru Beam Receiver

Control Box

Thru Beam Emitter

AC

N

X6*

Photoeye

BN

BU

OG

PHOTOEYES

Standard configuration is combined mode with DIP switches #1-9 in the OFF position and DIP switch #10 in the ON position. For independent mode and other DIP switch settings, consult the

BEA Matrix D12-24 User Manual.

X3

DC

LZR-i30 Presence Sensor

WH

ORG

BLK/WH

GRN/WH

GRN

not used

Control Box

0V

DC

BEA - LZR-i30

BK

RD

ORG/BLKnot used

BU

WH/BU

DC

0V

Sensor Sensor

WARNING DEVICE RELAY

BEA ACTIVATION

MISCELLANEOUS

ACTIVATION

PREANNOUNCE

DEVICES

Pairing:

WIRELESS

PUSHBUTTONS & PULL-CORDS

Control Box

X6**

DC

DC

0V

Host (Receiver)

6

4

5

7

To pair with a wireless device, first remove the plastic strip under the batteries in the remote unit to energize the device. On the Host (Receiver)

press "Remote Pairing". The "RF Com" LED will begin to flash. Next press the pair button on the remote unit. The units will then pair. Activate the door to test. Repeat procedure if necessary.

1 2 3 4 5

6 7 8 9 10

6

24V

7

0V

8

CLSG

9

RE

10

BKWY

1

OPEN

2

CLS

3

STOP

4

O/C

5

COM

ACTIVATOR

POWER SAFETY

RF Com

F aul t

RemotePairing

2.4GHz Wireless Activation

WIRELESS HOST

not used

not used

Set the input to 6 - Reverse N/C.

5 TWISTS/FT. MIN

IND

UC

TION

LOO

PC

ON

TR

OLLE

R

13

25

47

610

89

GN/YE 11

INDUCTIONLOOP A

INDUCTION

LOOP B

LPA

LPB

J5-3

J5-4

24VDC IN

0VDC IN

RELAY 1 (DC)

RELAY 1 (X13)

J5-5

J5-6

RD

BK

VT

GN

gray cable.

Sensor is connected by 4-conductor

X8

X9

DC

0V

GN

CLR

RD

BK

I-ZONEControl Box Sensor

I-ZONE 8900 w/

CONTROL BOX

gray cables. Green wire is not used.

Sensor is connected by 4-conductor

Sensor

SensorControl Box I-ZONE

Control Box

X9

0V

DC

0V

X8

DC

I-ZONE

CLR

BK

RD

BK

CLR

RD

I-ZONE 8900 w/ SIDEFRAME

CONTROLSINTERLOCKS

Relay Air Curtain

AIR CURTAIN INTERLOCK (120V)

11(4)

14(3)

Output Com

Ouput

A2(1)

A1(5)

i-COMM

YDC_

DC

Note: Consult i-COMM manual for

available output functions. Connect

relay contact to Air Curtain control.

Change YDC_ to 1 (on when door

not closed). Separate relay must be

used for isolation with 120VAC.

INSTALL SPDT RELAY IN CBOX

11(4)

DC COILA2(1)A1(5)

14(3)

Control Box Air Curtain

AIR CURTAIN INTERLOCK (24V)

YK3N

YK3

Output Com

Ouput

Note: Consult i-COMM manual for

available output functions. Connect

YK3 & YK3N to Air Curtain control.

Change YK3 to 1 (on when door not

closed).Note: Consult i-COMM manual to

see which inputs can be assigned

interlock in function. Connect YK3

to whichever input is selected to

become interlock in. No other devices should be connected to

this input. Terminal must be

assigned to Interlock through

i-COMM menu on both doors. (i.e.

If X3 is to be assigned a function of

Interlock Input, the menu ("Input

Func X3") should be set to a value

of "0")

Output YK3 (K3 relay) should

remain at the default setting of "0"

on both doors.

2 Door Non-Sequential Interlock

DC

YK3N

X?

YK3

Door1

YK3N

Door2

DC

X?

YK3

NON-SEQUENTIAL2 DOOR INTERLOCK

433MHz Radio Control

Control Box

X6**

DC

0V

DC

Receiver

BK

GN

RD

WH

RADIO CONTROL

1. SET DIP SWITCHES 1&2 TO OFF.2. PRESS LEARN W/NO DELAY.

3. PRESS TRANSMITTER BUTTON REPEATEDLY UNTIL BLUE LED ON RECEIVER ILLUMINATES.