13
PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 79 POWER BURNER Series LC/LCE • Large Commercial Boilers - Packaged, Assembled Block or Individual Sections • Forced Draft Venting • Power Burners - Oil, Gas, Gas/Oil • Steam or Hot Water Boilers • Optional Tankless Coils Standard Equipment: • Cast Iron Sections - Factory Tested • Wet Base Design, 50 PSI W.P. Sections • Flex-Seal Gaskets • High Temperature Rope Seal • Insulated Enameled Steel Jacket • Forced Draft Burner (WU, SU Models) • Burner Mounting Plate w/Observation Port • Cerafelt Base Liner and Target Wall • Rear Observation Port • Tankless Coil Cover Plates • Front and Top Cleanout Plates • Integral Cast Iron Flue Collector • Rear Flue Outlet w/Locking Damper on LC • Top Flue Outlet w/Locking Damper on LCE • Steel Channel Rails (Field Assembled Boilers) • Low Water Cut-Off (Packaged Boilers) Water (LC-04 to LC-12): • Operating Limit Control, L4006A • Limit Control, Manual Reset, L4006E • Pressure-Temperature Gage • 30 PSI Safety Relief Valve Steam (LC-04 to LCE-24): • Operating Pressure Control, PA404A • High Limit Pressure Control, Manual Reset, L4079B • Steam Pressure Gage • Gage Glass & Gage Cocks • 15 PSI Safety Valve SERIES LC/LCE BOILER RATINGS Series LC/LCE Boiler Model Oil Input 1 Gas Input, MBH Gross Output, MBH Net Ratings 4 Oil Gas GPH MBH Steam, sqft Steam 3 , MBH Water 2 , MBH Combustion Efficiency 5 , % Thermal Efficiency 5 , % Combustion Efficiency 5 , % Thermal Efficiency 5 , % LC-04 4.75 665 686 547 1,708 410 476 83.7 82.2 81.2 79.8 LC-05R 5.60 784 808 649 2,029 487 564 83.7 82.8 81.2 80.3 LC-05 6.10 854 881 707 2,208 530 615 83.7 82.8 81.2 80.3 LC-06 7.50 1,050 1,077 868 2,713 651 755 83.7 83.1 81.1 80.6 LC-07 8.80 1,232 1,273 1,029 3,217 772 895 83.6 83.3 81.1 80.8 LC-08 10.20 1,428 1,469 1,189 3,717 892 1,034 83.6 83.5 81.1 81.0 LC-09 11.60 1,624 1,664 1,350 4,250 1,020 1,174 83.6 83.6 81.1 81.1 LC-10 12.80 1,792 1,860 1,511 4,804 1,153 1,314 83.6 83.7 81.1 81.2 LC-11 14.20 1,988 2,056 1,672 5,367 1,288 1,454 83.6 83.8 81.1 81.3 LC-12 15.60 2,184 2,252 1,832 5,917 1,420 1,593 83.6 83.9 81.1 81.4 LCE-13 17.00 2,380 2,464 1,966 6,358 1,526 N/A 83.5 82.2 81.0 79.8 LCE-14 18.40 2,576 2,657 2,125 6,875 1,650 N/A 83.5 82.5 81.0 80.0 LCE-15 19.80 2,772 2,850 2,284 7,388 1,773 N/A 83.5 82.6 81.0 80.2 LCE-16 21.00 2,940 3,043 2,444 7,908 1,898 N/A 83.5 82.8 81.0 80.3 LCE-17 22.50 3,150 3,236 2,603 8,421 2,021 N/A 83.5 82.9 81.0 80.4 LCE-18 24.00 3,360 3,429 2,763 8,938 2,145 N/A 83.5 83.1 81.0 80.6 LCE-19 25.00 3,500 3,622 2,922 9,454 2,269 N/A 83.5 83.2 81.0 80.7 LCE-20 26.50 3,710 3,815 3,082 9,971 2,393 N/A 83.5 83.3 81.0 80.8 LCE-21 28.00 3,920 4,027 3,256 10,533 2,528 N/A 83.6 83.3 81.1 80.8 LCE-22 29.50 4,130 4,239 3,430 11,096 2,663 N/A 83.6 83.4 81.1 80.9 LCE-23 31.00 4,340 4,451 3,604 11,658 2,798 N/A 83.7 83.5 81.2 81.0 LCE-24 32.50 4,550 4,663 3,777 12,217 2,932 N/A 83.7 83.5 81.2 81.0 Boiler H.P. Approx. Shipping Weight lbs Less Burner Package Adder Trade Price 16.3 2,104 $7,594 $4,046 19.4 2,483 $8,624 $4,249 21.1 2,483 $8,624 $4,249 25.9 2,862 $10,072 $4,652 30.7 3,241 $11,062 $4,854 35.5 3,620 $12,659 $5,162 40.3 3,999 $14,376 $5,360 45.1 4,378 $15,947 $5,566 50.0 4,757 $17,392 $5,868 54.7 5,136 $18,949 $6,071 58.7 5,515 $20,217 $6,271 63.5 5,894 $21,289 $6,474 68.2 6,273 $22,583 $6,652 73.0 6,652 $23,764 $6,880 77.7 7,031 $24,816 $7,080 82.5 7,410 $26,205 $7,281 87.3 7,789 $27,379 $7,482 92.1 8,168 $28,551 $7,807 97.3 8,547 $30,634 $7,968 102.5 8,926 $31,719 $8,173 107.7 9,305 $32,923 $8,372 112.8 9,684 $34,053 $8,580 1 Burner input based on No. 2 fuel oil with a heating value of 140,000 BTU per gallon. 2 Net water ratings based on allowance of 1.15. 3 Net steam ratings based on an allowance for LC-04 to LC-08=1.333, LC-09=1.323, LC-10=1.310, LC-11=1.298, LC-12=1.290, LCE-13 to LCE-24=1.288. 4 Consult factory before selecting a boiler for installation having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. 5 Combustion and thermal efficiency determined in accordance with BTS 2000 Testing Standard. Visit www.PeerlessBoilers.com for Additional LC/LCE Product Specifications, Warranty and Extended Warranty Information See pages 103-104 for Notes; pages 109-112 for Optional Controls and Components and page 112 for Tankless Water Heater Ratings.

79 lc lce 18€  Limit Control, Manual Reset, L4006E † Pressure-Temperature Gage † 30 PSI Safety Relief Valve Steam (LC-04 to LCE-24): † Operating Pressure Control, PA404A †

Embed Size (px)

Citation preview

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 79

POWER BURNER

Series LC/LCE ™

• Large Commercial Boilers - Packaged, Assembled Block or Individual Sections

• Forced Draft Venting • Power Burners - Oil, Gas, Gas/Oil

• Steam or Hot Water Boilers • Optional Tankless Coils

Standard Equipment:• Cast Iron Sections - Factory Tested

• Wet Base Design, 50 PSI W.P. Sections

• Flex-Seal Gaskets

• High Temperature Rope Seal

• Insulated Enameled Steel Jacket

• Forced Draft Burner (WU, SU Models)

• Burner Mounting Plate w/Observation Port

• Cerafelt Base Liner and Target Wall

• Rear Observation Port

• Tankless Coil Cover Plates

• Front and Top Cleanout Plates

• Integral Cast Iron Flue Collector

• Rear Flue Outlet w/Locking Damper on LC

• Top Flue Outlet w/Locking Damper on LCE

• Steel Channel Rails (Field Assembled Boilers)

• Low Water Cut-Off (Packaged Boilers)

Water (LC-04 to LC-12):• Operating Limit Control, L4006A

• Limit Control, Manual Reset, L4006E

• Pressure-Temperature Gage

• 30 PSI Safety Relief Valve

Steam (LC-04 to LCE-24):• Operating Pressure Control, PA404A

• High Limit Pressure Control, Manual Reset, L4079B

• Steam Pressure Gage

• Gage Glass & Gage Cocks

• 15 PSI Safety Valve

SERIES LC/LCE™ BOILER RATINGS

Series LC/LCE™

BoilerModel

Oil Input1Gas

Input, MBH

GrossOutput,

MBH

Net Ratings4 Oil Gas

GPH MBHSteam,

sqftSteam3,

MBHWater2,

MBHCombustion

Efficiency5, %Thermal

Efficiency5, %Combustion

Efficiency5, %Thermal

Efficiency5, %

LC-04 4.75 665 686 547 1,708 410 476 83.7 82.2 81.2 79.8

LC-05R 5.60 784 808 649 2,029 487 564 83.7 82.8 81.2 80.3

LC-05 6.10 854 881 707 2,208 530 615 83.7 82.8 81.2 80.3

LC-06 7.50 1,050 1,077 868 2,713 651 755 83.7 83.1 81.1 80.6

LC-07 8.80 1,232 1,273 1,029 3,217 772 895 83.6 83.3 81.1 80.8

LC-08 10.20 1,428 1,469 1,189 3,717 892 1,034 83.6 83.5 81.1 81.0

LC-09 11.60 1,624 1,664 1,350 4,250 1,020 1,174 83.6 83.6 81.1 81.1

LC-10 12.80 1,792 1,860 1,511 4,804 1,153 1,314 83.6 83.7 81.1 81.2

LC-11 14.20 1,988 2,056 1,672 5,367 1,288 1,454 83.6 83.8 81.1 81.3

LC-12 15.60 2,184 2,252 1,832 5,917 1,420 1,593 83.6 83.9 81.1 81.4

LCE-13 17.00 2,380 2,464 1,966 6,358 1,526 N/A 83.5 82.2 81.0 79.8

LCE-14 18.40 2,576 2,657 2,125 6,875 1,650 N/A 83.5 82.5 81.0 80.0

LCE-15 19.80 2,772 2,850 2,284 7,388 1,773 N/A 83.5 82.6 81.0 80.2

LCE-16 21.00 2,940 3,043 2,444 7,908 1,898 N/A 83.5 82.8 81.0 80.3

LCE-17 22.50 3,150 3,236 2,603 8,421 2,021 N/A 83.5 82.9 81.0 80.4

LCE-18 24.00 3,360 3,429 2,763 8,938 2,145 N/A 83.5 83.1 81.0 80.6

LCE-19 25.00 3,500 3,622 2,922 9,454 2,269 N/A 83.5 83.2 81.0 80.7

LCE-20 26.50 3,710 3,815 3,082 9,971 2,393 N/A 83.5 83.3 81.0 80.8

LCE-21 28.00 3,920 4,027 3,256 10,533 2,528 N/A 83.6 83.3 81.1 80.8

LCE-22 29.50 4,130 4,239 3,430 11,096 2,663 N/A 83.6 83.4 81.1 80.9

LCE-23 31.00 4,340 4,451 3,604 11,658 2,798 N/A 83.7 83.5 81.2 81.0

LCE-24 32.50 4,550 4,663 3,777 12,217 2,932 N/A 83.7 83.5 81.2 81.0

BoilerH.P.

Approx.ShippingWeight

lbs

Less Burner

PackageAdder

TradePrice

16.3 2,104 $7,594 $4,046

19.4 2,483 $8,624 $4,249

21.1 2,483 $8,624 $4,249

25.9 2,862 $10,072 $4,652

30.7 3,241 $11,062 $4,854

35.5 3,620 $12,659 $5,162

40.3 3,999 $14,376 $5,360

45.1 4,378 $15,947 $5,566

50.0 4,757 $17,392 $5,868

54.7 5,136 $18,949 $6,071

58.7 5,515 $20,217 $6,271

63.5 5,894 $21,289 $6,474

68.2 6,273 $22,583 $6,652

73.0 6,652 $23,764 $6,880

77.7 7,031 $24,816 $7,080

82.5 7,410 $26,205 $7,281

87.3 7,789 $27,379 $7,482

92.1 8,168 $28,551 $7,807

97.3 8,547 $30,634 $7,968

102.5 8,926 $31,719 $8,173

107.7 9,305 $32,923 $8,372

112.8 9,684 $34,053 $8,580

1 Burner input based on No. 2 fuel oil with a heating value of 140,000 BTU per gallon.2 Net water ratings based on allowance of 1.15.3 Net steam ratings based on an allowance for LC-04 to LC-08=1.333, LC-09=1.323, LC-10=1.310, LC-11=1.298, LC-12=1.290, LCE-13 to LCE-24=1.288. 4 Consult factory before selecting a boiler for installation having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.5 Combustion and thermal efficiency determined in accordance with BTS 2000 Testing Standard.

Visit www.PeerlessBoilers.com for Additional LC/LCE™ Product Specifications, Warranty and Extended Warranty Information See pages 103-104 for Notes; pages 109-112 for Optional Controls and Components and

page 112 for Tankless Water Heater Ratings.

80 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018

Series LC/LCE ™

Ordering Information:Example:

O – LC/LCE – 06 – WU –STD – 30PSI

Sects. STD, FMSeries 15 PSI Steam (STD)

30 PSI Water (STD)Blank = No Burner 50 PSI O = Oil 80 PSI G = Gas WATER STEAMGO = Gas/Oil W S = Less Burner (KD)

WU SU = w/ Burners & Contr. (KD)WUP SUP = Pkg. w/Burn. &

ControlsWP SP = Pkg. Less Burner

OPTIONAL EQUIPMENT TRADE PRICESAdd to Trade Price

Description Trade Price

80 PSI Working Pressure Sections (water only)*50 PSI Relief Valve (in lieu of standard)

$87 Per SectionNo Charge

Factory Assembled Sections $168 Per Section

1-1/2″ Inspection Tappings(Two per section / RH side)

w/brass plugw/nipple & cap

$113 Per Section$134 Per Section

Mounting of Optional Controls on Packaged Boilers $132 Per Control

Factory Fire Test of Packaged Boilers (Nat. Gas or #2 Oil)Functional w/o Combustion ReportComprehensive w/Combustion Report

$499$993

Barometric Draft Dampers Code No.

LC-04 thru LC-05 9″ 50255LC-06 thru LC-08 10″ 90391LC-09 thru LC-12 12″ 90394LCE-13 thru LCE-1714″ 91198LCE-18 thru LCE-2416″ 90396Thermal Switch for Draft Damper 50702

$219$282$351$501$614$176

*30 PSI relief valve furnished unless otherwise specified on order

DOMESTIC WATER COILSCode No. Capacity, gal/min.

200 Boiler Water❖PressureDrop-PSI

Inlet/OutletTapping

ShippingWeight Lbs.

TradePrice

90534 X-1020 3 3 3/4" 25 $294

90537 X-1021 6 5 3/4" 33 $631

90539 X-1022 6.5 12 3/4" 33 $921

❖Intermittent draw 100°F average rise

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 81

Series LC/LCE ™

82 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018

Series LC/LCE ™

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 83

Series LC/LCE ™

84 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018

Series LC/LCE ™

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 85

Series LC/LCE ™

86 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018

Series LC/LCE ™

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 87

Series LC/LCE ™

88 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018

Series LC/LCE ™

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 89

Series LC/LCE ™

Series LC/LCE ™

90 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018

PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 91

CRATE DIMENSIONSBoilerModel Length Width Height

LC-04LC-05RLC-05

78″83″83″

58″58″58″

75″75″75″

LC-06LC-07LC-08

88″93″102″

58″58″58″

75″75″75″

LC-09LC-10LC-11

107″112″117″

58″58″58″

75″75″75″

LC-12LCE-13LCE-14

122″127″132″

58″58″58″

75″75″75″

LCE-15LCE-16LCE-17

137″142″151″

58″58″58″

75″75″75″

LCE-18LCE-19LCE-20

156″161″166″

58″58″58″

75″75″75″

LCE-21LCE-22LCE-23LCE-24

171″171″182″187″

58″58″58″58″

75″75″75″75″

Series LC/LCE ™

Visit www.PeerlessBoilers.com for Additional LC/LCE™

Product Specifications, Warranty and ExtendedWarranty Information See pages 103-104 for Notes; pages 109-112 for Optional Controls and

Components and page 112 for Tankless Water Heater Ratings.