DETTSON ALIZÉ INTERFACE (K03081) QUICK SETUP GUIDE 2016-07-06 X40237 rev. D Simple startup 1. Turn off the breaker of the outdoor unit and the furnace 2. Connect COND1 and COND2 on the interface board to N(1) and 2 at the outdoor unit (See complete manuel included with the unit) 3. Connect the interface board to the furnace: 1. Communicating thermostat: i. Connect the RJ-11 wire (A00443) between the interface and the furnace control board (See complete manuel included with the unit) 2. Legacy thermostat: i. Connect all the thermostat control wires to the interface card and the air handler control board ii. Make sure to connect the heat output W1 out and W2 out of the thermostat to the W1 and W2 inputs of the furnace –OR – W on W2 on a single stage thermostat 4. Turn “ON” the breaker of the outdoor unit 5. Turn “ON” the breaker of the furnace Make sure the unit is working properly 1. The Green LED on the interface board should be blinking once every two seconds 2. The Orange LED on the interface board should be blinking once every two seconds 3. The communicating thermostat will display “Heat_Pump_Found” 4. Set the thermostat to “COOL” mode and adjust the set point to a lower value than the actual room temperature 5. The furnace and the outdoor unit should start within 5 minutes In this configuration, the interface board will gather information from both the outdoor unit and the furnace in order to adjust the fan speed to the capacity of the outdoor unit * Alizé 9/12 kBTU shown. See the Electrical Diagrams section of the Alizé manual for other models. INSTALLATION IN VARIOUS MODULATING FURNACES CHINOOK SUPREME Legacy wiring

(77621 $/,=e ,17(5)$&( . - Dettson | Proud manufacturer of ... FRPPXQLFDWLQJ WKHUPRVWDW 5 3 LV UHTXLUHG &RQQHFW WKH (59 +59 XQLW EHWZHHQ WKH 5 DQG * WHUPLQDOV RQ WKH ,QWHUIDFH %RDUG

  • Upload
    vomien

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: (77621 $/,=e ,17(5)$&( . - Dettson | Proud manufacturer of ... FRPPXQLFDWLQJ WKHUPRVWDW 5 3 LV UHTXLUHG &RQQHFW WKH (59 +59 XQLW EHWZHHQ WKH 5 DQG * WHUPLQDOV RQ WKH ,QWHUIDFH %RDUG

DETTSON ALIZÉ INTERFACE (K03081) QUICK SETUP GUIDE

2016-07-06 X40237 rev. D

Simple startup 1. Turn off the breaker of the outdoor unit and the furnace 2. Connect COND1 and COND2 on the interface board to N(1) and 2 at the outdoor unit (See complete manuel included with the unit) 3. Connect the interface board to the furnace:

1. Communicating thermostat: i. Connect the RJ-11 wire (A00443) between the interface and the furnace control board (See complete manuel included with the unit)

2. Legacy thermostat: i. Connect all the thermostat control wires to the interface card and the air

handler control board ii. Make sure to connect the heat output W1 out and W2 out of the thermostat to the W1 and W2 inputs of the furnace –OR – W on W2 on a single stage thermostat

4. Turn “ON” the breaker of the outdoor unit 5. Turn “ON” the breaker of the furnace Make sure the unit is working properly 1. The Green LED on the interface board should be blinking once every two seconds 2. The Orange LED on the interface board should be blinking once every two seconds 3. The communicating thermostat will display “Heat_Pump_Found” 4. Set the thermostat to “COOL” mode and adjust the set point to a lower value than the

actual room temperature 5. The furnace and the outdoor unit should start within 5 minutes

In this configuration, the interface board will gather information from both the outdoor unit and the furnace in order to adjust the fan speed to the capacity of the outdoor unit

* Alizé 9/12 kBTU shown. See the Electrical Diagrams section of the Alizé manual for other models.

INSTALLATION IN VARIOUS MODULATING FURNACES

CHINOOK SUPREME

Legacy wiring

Page 2: (77621 $/,=e ,17(5)$&( . - Dettson | Proud manufacturer of ... FRPPXQLFDWLQJ WKHUPRVWDW 5 3 LV UHTXLUHG &RQQHFW WKH (59 +59 XQLW EHWZHHQ WKH 5 DQG * WHUPLQDOV RQ WKH ,QWHUIDFH %RDUG

DETTSON ALIZÉ INTERFACE (K03081) QUICK SETUP GUIDE

2016-07-06 X40237 rev. D

Balance point adjustment Communicating thermostat: 1. On the thermostat’s Home Screen Display, touch the Menu key to display additional key choices 2. Touch and hold the Installer Config key for approximately 3 seconds to enter the Thermostat Configuration Menu 3. Touch and hold the Installer Config key for approximately 3 seconds to enter the Advanced Installer Configuration Menu 4. Using the up or down arrows, select “THERMOSTAT” 5. Touch the Installer Config key 6. Using the up or down arrows, select “SETUP” 7. Touch the Installer Config key 8. Using the up or down arrows, select “BALANCE PT” 9. Using the right or left arrows, set the desired balance point 10. Touch the Run Schedule key to return to the Home Screen

Legacy wiring: 1. On the Interface Board, before powering the unit, set the balance point using the dipswitches #2, #3 and #4

DIP2 DIP3 DIP4 Balance Point OFF OFF OFF -15°C (5°F) OFF OFF ON -13°C OFF ON OFF -11°C OFF ON ON -9°C ON OFF OFF -7°C ON OFF ON -5°C ON ON OFF -3°C ON ON ON HP heat only

To run the outdoor unit in “Air Conditioner” mode (no heat), turn ON the dipswitch #1. ERV/HRV wiring The communicating thermostat (R02P029) is required

1. Connect the ERV/HRV unit between the R and G terminals on the Interface Board 2. Connect the RJ-11 wire (A00443) between the interface and the furnace control board (See complete manuel included with the unit)

3. Adjust the desired fan demand for ERV/HRV using the dipswitches #2, #3 and #4 DIP1 DIP2 DIP3 DIP4 Fan Demand

- OFF OFF OFF 20% - OFF OFF ON 25% - OFF ON OFF 30% - OFF ON ON 35% - ON OFF OFF 40% - ON OFF ON 45% - ON ON OFF 50% - ON ON ON 55%

DIP1 Mode OFF AC & HP ON AC Only

Page 3: (77621 $/,=e ,17(5)$&( . - Dettson | Proud manufacturer of ... FRPPXQLFDWLQJ WKHUPRVWDW 5 3 LV UHTXLUHG &RQQHFW WKH (59 +59 XQLW EHWZHHQ WKH 5 DQG * WHUPLQDOV RQ WKH ,QWHUIDFH %RDUG

INTERFACE ALIZÉ DETTSON (K03081) GUIDE D’INSTALLATION RAPIDE

2016-07-06 X40237 rev. D

Démarrage simple 1. Éteindre le disjoncteur de l’unité extérieure et de la fournaise 2. Connecter COND1 et COND2 de la carte d’interface à N(1) et 2 de l’unité extérieure (Voir le manuel complet fourni avec l’unité) 3. Connecter la carte d’interface à la fournaise:

Thermostat communiquant: i. Connecter le fil RJ-11 (A00443) entre l’interface et la carte de contrôle de la fournaise (Voir le manuel complet fourni avec l’unité)

Thermostat « legacy »: i. Connecter tous les fils du thermostat à la carte d’interface et à la carte de

contrôle de l’unité de ventilation ii. S’assurer de connecter les signaux en chauffage, sorties W1 et W2 connectées aux entrées W1 and W2 de la fournaise – OU – W sur W2 pour un thermostat 1 stage 4. Connecter le fil RJ-11 entre l’interface et la carte de contrôle de la fournaise (Voir le

manuel complet fourni avec l’unité) 5. Mettre le disjonteur de l’unité extérieure sur “ON” 6. Mettre le disjoncteur de la fournaise sur “ON” S’assurer que l’unité fonctionne correctement 1. La LED verte de la carte d’interface doit clignoter toutes les deux secondes 2. La LED orange de la carte d’interface doit clignoter toutes les deux secondes 3. Le thermostat communicant doit afficher “Heat_Pump_Found” (« thermopompe

détectée ») 4. Régler le thermostat en mode “COOL” (climatisation) et ajuster le point de consigne

à une valeur inférieure à la température actuelle de la pièce 5. La fournaise et l’unité extérieure devraient démarrer en moins de 5 minutes

Dans cette configuration, la carte d’interface va rassembler en même temps l’information sur l’unité extérieure et sur la fournaise afin d’ajuster la vitesse du ventilateur à la capacité de l’unité extérieure

* Alizé 9/12 kBTU montrée. Voir la section Diagrammes électrique du manuel de l’Alizé pour les autres modèles.

INSTALLATION DANS LES DIFFÉRENTS APPAREILS MODULANTS

CHINOOK SUPREME

Branchement «legacy»

Page 4: (77621 $/,=e ,17(5)$&( . - Dettson | Proud manufacturer of ... FRPPXQLFDWLQJ WKHUPRVWDW 5 3 LV UHTXLUHG &RQQHFW WKH (59 +59 XQLW EHWZHHQ WKH 5 DQG * WHUPLQDOV RQ WKH ,QWHUIDFH %RDUG

INTERFACE ALIZÉ DETTSON (K03081) GUIDE D’INSTALLATION RAPIDE

2016-07-06 X40237 rev. D

Ajustement du point de basculement Thermostat communiquant: 1. Sur l’écran d’accueil du thermostat, appuyer sur Menu pour afficher les options additionnelles 2. Appuyer et maintenir la touche Installer Config environ 3 secondes pour afficher le menu de configuration du thermostat 3. Appuyer et maintenir la touche Installer Config environ 3 secondes pour afficher le menu de configuration installateur

avancé 4. En utilisant les flèches haut et bas, sélectionner « THERMOSTAT » 5. Appuyer sur la touche Installer Config 6. En utilisant les flèches haut et bas, sélectionner « SETUP » 7. Appuyer sur la touche Installer Config 8. En utilisant les flèches haut et bas, sélectionner « BALANCE PT » 9. En utilisant les flèches droite et gauche, ajuster le point de basculement à la valeur désirée 10. Appuyer sur la touche Run Schedule pour revenir à l’écran d’accueil

Branchement « legacy » : 1. Sur la carte d’interface, avant d’alimenter l’unité, ajuster le point de basculement en utilisant les dipswitches #2, #3 et #4

DIP2 DIP3 DIP4 Point de basculement OFF OFF OFF -15°C (5°F) OFF OFF ON -13°C OFF ON OFF -11°C OFF ON ON -9°C ON OFF OFF -7°C ON OFF ON -5°C ON ON OFF -3°C ON ON ON Chauffage thermopompe

uniquement Pour mettre l’unité extérieure en mode climatiseur seulement (pas de chauffage), mettre à ON la dipswitch #1. Branchement ERV/HRV Le thermostat communiquant (R02P029) est requis

1. Brancher l’unité ERV/HRV entre les bornes R et G de la carte d’interface 2. Connecter le fil RJ-11 (A00443) entre l’interface et la carte de contrôle de la fournaise (Voir le manuel complet fourni avec l’unité intérieure)

3. Ajuster la demande de ventilation continue pour ERV/HRV en utilisant les dipswitches #2, #3 et #4 DIP1 DIP2 DIP3 DIP4 Demande de ventilation

- OFF OFF OFF 20% - OFF OFF ON 25% - OFF ON OFF 30% - OFF ON ON 35% - ON OFF OFF 40% - ON OFF ON 45% - ON ON OFF 50% - ON ON ON 55%

DIP1 Mode OFF Climatisation et chauffage ON Climatisation seulement