Light sensitive switchesOut of darkness comes light!
�UT0003�_03-2007_EN
Presentation 2
Choicetable IC�00, IC200, IC2000, IC2000P+, IC Astro 4
Technicaldatas IC�00, IC200 5 IC2000 6IC2000P+ 8 IC Astro ��
ConnectionandcataloguenumberIC�00, IC200, IC2000 7 IC2000P+ 9 IC Astro �2
PracticaladviceIC2000P+ �0 IC Astro �3
DimensionsIC�00, IC200, IC2000, IC2000P+, IC Astro �4
Summary
2
Light sensitive switches
UT0003�_03-2007_EN
IC light-sensitive switches automatically control lighting, roller blinds, etc. according to brightness and/or the time of the day.
Energy savingsWhatever the type of building or infrastructure, it is important nowadays to optimize your energy costs.With the IC light-sensitive switches range’s wide diversity and time and geographic programming, you can optimize your lighting and avoid pointless consumption.
Convenient useIC light-sensitive switches are used to manage and control lighting whenever and however you wish. Self-contained and automatic, they provide you with light, simply and at the right time.
Increased securityProtection against vandalism is provided by lighting up dark areas.
Lighting of public building
Public lighting
PresentationOut of darkness comes light!
Easy installationExtremely simple to implement and install, the switches fit all electrical and modular enclosures. IC 2000 is equipped with screw-less terminals for fast, easy connection.
Lighting of a car park
3UT0003�_03-2007_EN
IC100Adjustable from 2 to �00 lux. It comes with a wall-mounted cell.
P83
235-
42
P83
237-
38
IC2000Adjustable from 2 to 2000 lux. It comes with a wall-mounted cell.
P93
585
P93
367
IC2000P+It has 3 customisable pre-set programs and 3 setting ranges from 2 to 2100 lux. Its 4 keys and large screen facilitate its programming. It comes with a wall-mounted cell.
P83
236-
40
P83
237-
38
IC AstroIt operates without photoelectric cell and calculates sunrise and sunset times according to its geographic position. it can be customised by using its programmation function.
PB
�002
07-4
0
DB
�092
�7
IC200Adjustable from 2 to 200 lux. It comes with a switchboard cell.
P94
774
4
Light sensitive switches
UT0003�_03-2007_EN
IC100 IC200 IC2000 IC2000P+ ICAstroCataloguenumbers 15482 15284 CCT15368 15483 15223 15224Control by brightness detection b b b b Coupling with weekly programming b b b Control by calculation of sunrise/sunset times
b b
TechnicaldataVoltage (+�0 %, -�5 %) 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V ACFrequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 HzAdjustable brightness threshold
2 to �00 lx 2 to 200 lx 2 to 2000 lx 2 to 50 lx 60 to 300 lx 350 to 2�00 lx
Consumption 6 VA 3 VA 6 VA 3 VA 4 VA 4 VASwitching capacity (cos j = �) �6 A �0 A �6 A �6 A �6 A �6 AMonitoring indicator light, not time delayed lit when brightness is less than the threshold
Red b Red
Contact switching indicator light Green GreenLCD liquid crystal display Back-lit Back-lit Back-litProgram saving by lithium battery b b b Operating reserve 5-6 years 6 years 6 yearsOperating temperature -20 to +50 °C -�0 to +50 °C -25 to +55 °C -20 to +50 °C -20 to +50 °C -20 to +50 °CSimplified leaflet incorporated in the “leaflet holder” slot under the swivel cover
b b b b b
Width (9 mm modules) 2 5 5 5 5 5� screw connection per pole for cables up to 6 mm²
b b b b b
2 screw-less connection per pole for cables up to 2.5 mm²
b
Mechanical compatibility with electrical distribution comb busbars
b
Cabling test function with a push-button on front face
b
Languages fr, gb, es, it, de, pt, se, dk/no, fi, nl
fr, gb, es, it, de, pt
fr, gb, se, dk/no, fi, nl
Delivered with wall-mounted cell cat. no. �5268
b b
Delivered with wall-mounted cell, cat. no. CCT�5268
b
Delivered with switchboard cell cat. no. �528�
b
CellchoicetableforsparepartsSparecell Cat.no.Switchboard cell, IP65 �528�Wall-mounted cell, IP54 ( compatible with all products) CCT�5268
ChoicetableIC�00, IC200, IC2000, IC2000P+, IC Astro
Switchboard cell cat. no. �528�
Wall-mounted cell cat. no. �5268
Wall-mounted cell cat. no. CCT�5268
P83
237-
38
DB
�092
�7
P93
585
5UT0003�_03-2007_EN
TechnicaldataIC�00, IC200
FunctionThe light sensitive switch controls closing of a contact when brightness decreases and drops below the selected threshold. It controls opening of a contact when brightness increases and rises above the selected threshold.
TechnicaldataIC100b Adjustable brightness threshold: 2 to �00 lux.b Time delay: on closing: 20 s, on contact breaking: 80 s.b Contact opening: < 3 mm.b Insulation class: class II.b Degree of protection: IP20B.b Compatible with electrical distribution comb busbars.b Delivered with wall-mounted cell and its fixing device.b Contact rating: v �6 A under 250 V AC (cos j = �), v �0 A under 250 V AC (cos j = 0.6). b IC�00 load table:Typeoflighting Max.power230 V incandescent and halogen lamps 2300 WNon-corrected/ serial-corrected/ dual mounted fluorescent tubes with conventional ballast
2300 VA
Fluocompact lamps with conventional ballast �500 VA
Non-corrected/ serial-corrected mercury and sodium vapour lamps
�000 VA
Parallel-corrected mercury/ sodium vapour lamps and parallel-corrected fluorescent tubes with conventional ballast
400 VA
Fluorescent tubes/ dual mounted with electronic ballast 300 VAFluocompact lamps with electronic ballast 9 x 7 W, 7 x �� W, 7 x �5 W, 7 x 20 W,
7 x 23 W
IC200b Brightness threshold: adjustable from 2 to 200 lux.b Time delay on contact closing and breaking: ≥ 40 s.b Delivered with switchboard front face cell.b Contact rating: v �6 A under 250 V AC (cos j = �), v �0 A under 250 V AC (cos j = 0.6). b IC200 load table:Typeoflighting Max.power230 V incandescent, halogen lamps and fluocompact lamp with conventional ballast
2300 W
Non-corrected/ serial-corrected fluorescent tubeswith conventional ballast
46 x 36 W, 23 x 58 W, �4 x �00 W
Parallel-corrected fluorescent tubes with conventional ballast
�0 x 36 W, 6 x 58 W, 2 x �00 W
Dual-mounted fluorescent tubes with conventional ballast
�� x (2 x 58 W), 6 x (2 x �00 W)
Fluorescent tubes with electronic ballast 9 x 36 W, 7 x 58 WDual-mounted fluorescent tubes with electronic ballast 5 x (2 x 36 W), 4 x (2 x 58 W)Fluocompact lamps with electronic ballast 6 x 7 W, 8 x �� W, 6 x �5 W, 6 x 20 WParallel-corrected mercury and sodium vapour lamps 250 W
Wall-mountedcell-cat.no.15268(delivered with product and its fixing device)b Cell connection: by double insulation 2-conductor cable, not to be laid next to mains cables or water ducts, maximum length: 25 m for IC�00,b Degree of protection: IP54, IK05.b Operating temperature: -40°C to +70°C.
Switchboardcell(delivered with product and its fixing device)b Delivered with � m cable.b Degree of protection: IP65.b Operating temperature: -40°C to +70°C.
P83
235-
42
IC�00 Wall-mounted cell
IC200 Switchboard cell
P94
774
P83
237-
38
DB
�092
�7
6
Light sensitive switches
UT0003�_03-2007_EN
FunctionThe light sensitive switch controls closing of a contact when brightness decreases and drops below the selected threshold. It controls opening of a contact when brightness increases and rises above the selected threshold.
Technicaldatab Adjustable brightness threshold: 2 to 2000 lx.b Time delay on contact closing and breaking: 60 s.b Cabling test function with a push-button on front face.b Contact opening: < 3 mm.b Insulation class: class II.b Degree of protection: IP20B.b Delivered with wall-mounted cell and its fixing device.b Contact rating: v �6 A under 250 V AC (cos j = �), v �0 A under 250 V AC (cos j = 0.6). b Load table:Typeoflighting Max.power230 V incandescent and halogen lamps 2300 WNon-corrected/ serial-corrected/ dual mounted fluorescent tubes with conventional ballast
2300 VA
Fluocompact lamps with conventional ballast �500 VANon-corrected/ serial-corrected mercury and sodium vapour lamps
�000 VA
Parallel-corrected mercury/ sodium vapour lamps and parallel-corrected fluorescent tubes with conventional ballast
400 VA
Fluorescent / dual-mounted fluorescent tubes with electronic ballast
300 VA
Fluocompact lamps with electronic ballast 9 x 7 W, 7 x �� W, 7 x �5 W, 7 x 20 W, 7 x 23 W
Wall-mountedcell,cat.no.CCT15268(delivered with product and its fixing device)b Cell connection: by double insulation 2-conductor cable, not to be laid next to mains cables or water ducts, maximum length: �00 m.b Horizontally orientable (90 °). b Degree of protection: IP54, IK05.b Operating temperature: -40°C to +70°C.
TechnicaldataIC2000
P93
367
IC2000
P93
585
Wall-mounted cell
7UT0003�_03-2007_EN
ConnectionIC100,IC200,IC2000b Connection terminals: v � screw connection per pole for cables up to 6 mm² for IC�00 and IC200, v 2 screw-less connection per pole for cables up to 2.5 mm² for IC 2000.
IC�00 IC200 IC2000
IC100b To guarantee safety of people, it is essential to comply with positioning of the power supply (L and N terminal). Reversal of these two terminals is forbidden.b Determination of ratings according to the power of the load(s).v Power ≤ �6 A, Cos j = � (Fig. �).v Power > �6 A, Cos j = � (Fig. 2): you must relay with a contactor.
IC200,IC2000b Determination of ratings according to the power of the load(s). v Power ≤ �0 A, Cos j = 1 (fig. 3). v Power > �0 A, Cos j = 1 (fig. 4): you must relay with a contactor. b To facilitate threshold setting, mount the resistor (47 kW) supplied in place of the cell (terminals 3-5). Act on the threshold setting potentiometer until the red LED lights up.
CataloguenumbersType Cat.no.IC�00 15482IC200 15284IC2000 CCT15368
DB
�092
�2
DB
�092
�5
DB
�092
��
Fig.3
DB
�093
45
DB
�093
46
Fig.4
(1) Determination of ratings according to the power of the load(s).
DB
�090
03
Fig.2
DB
�090
02
Fig.�
ConnectionandcataloguenumberIC�00, IC200, IC2000
8
Light sensitive switches
UT0003�_03-2007_EN
FunctionThe IC2000P+ controls lighting according to brightness and time. If brightness drops below the set threshold (light sensitive function: IC) and if the time program allows relay closing (time switch function), then the lighting circuit is activated.
DescriptionThe IC2000P+ uses its time programming to define lighting On and Off periods:b According to three pre-set time programs:v “DAYPROG”: On time programming from 7 am to 8 pm a validation of the IC function from 7 am to 8 pm,v “NIGHTPROG”: On time programming from 5 am to 8 am and from 6 pm to �� pm a validation of the IC function on these two operating periods,v “EMPTYPROG”: Off time programming throughout the day a no validation of the IC function. These programs can be modified if necessary.b According to a customised operating period, with possibility of copying to the other days.It is equipped with the following functions:v consideration of periods of absence (holidays),v temporary or permanent On or Off override,v remote control of lighting override by NO external contact,v consideration of change to “summer/winter” time, automatic or manual,v permanent liquid crystal display: of time and minutes, of day of the week, of the contact output status and current program.
Technicaldatab Adjustable brightness threshold over 3 ranges: v range �: 2 to 50 lx, v range 2: 60 to 300 lx, v range 3: 350 to 2�00 lx. b Time delay on contact closing and breaking: separate setting between 20 s and �40 s (80 s by default). b Contact: potential free. b Time base: quartz. b Operating accuracy: < ± � s / day at 20°C. b Number of separate switching operations: 42. b Minimum switching: � min. b Switching accuracy: � s. b Insulation class: class II. b Degree of protection: IP20B. b Contact rating: v �6 A under 250 V AC (cos j = �), v �0 A under 250 V AC (cos j = 0.6). b Load table:Typeoflighting Max.power230 V incandescent and halogen lamps 2300 WNon corrected/serial corrected fluorescent tubeswith conventional ballast
26 x 36 W, 20 x 58 W, �0 x �00 W
Parallel corrected fluorescent tubes with conventional ballast
�0 x 36 W, 6 x 58 W, 2 x �00 W
Dual-mounted fluorescent tubes with conventional ballast
�0 x (2 x 58 W), 5 x (2 x �00 W)
Fluorescent tubes with electronic ballast 9 x 36 W, 6 x 58 WDual-mounted fluorescent tubes with electronic ballast 5 x (2 x 36 W), 3 x (2 x 58 W)Fluocompact lamps with electronic ballast 9 x 7 W, 7 x �� W, 7 x �5 W, 7 x 20 WParallel-corrected mercury and sodium vapour lamps 250 W
Wall-mountedcell(delivered with product and its fixing device)b Photoresistance, connection by 2-wire cable, �00 m max. Do not install parallel to mains cables.b Degree of protection: IP54, IK05.b Operating temperature: -40°C to +70°C.Externalinputb Voltage: 230 V AC, +�0 %, -�5 %. b Frequency: 50/60 Hz. b Input current: max. 2.5 mA. b Consumption: max. 0.4 mW. b Cable length: max. �00 m.
TechnicaldataIC2000P+
P83
236-
40
P83
237-
38
IC2000P+
Wall-mounted cell
9UT0003�_03-2007_EN
Connectionb Connection terminals: � screw connection per pole for cables up to 6 mm² .
CataloguenumbersType Cat.no.IC2000P+ �5483
DB
�092
�3
On override external contact
ConnectionandcataloguenumberIC2000P+
�0
Light sensitive switches
UT0003�_03-2007_EN
1
0
14h 23h
0
DB
�092
22Fig. �
DB
�090
7�
Fig. 2
Time switch function
ThresholdBrightness
IC2000P+ output
ON override external contact
Applicationexample(Fig. �)Lighting of a shop window, in the evening, at a time variable according to brightness and switch-off at a set time (e.g. �� pm). Then in the morning, lighting at a set time (e.g. 4 am) and switch-off at a time variable according to brightness.
ConfigurationThis consists of recording in the memory:b The languageb The year, month, day and timeb One of the 3 pre-set programs:v “DAYPROG”: “On” time programming from 7 am to 8 pm a validation of the IC function from 7 am to 8 pm,v “NIGHTPROG”: “On” time programming from 5 am to 8 am and from 6 pm to �� pm a validation of the IC function on these two operating periods,“EMPTYPROG”: “Off” time programming throughout the day a no validation of the IC function. These programs can be modified.b The brightness threshold. Once this phase is over, your IC2000P+ operates in AUTO mode according to the items you have chosen.
ProgrammingTheIC2000P+isusedtomanagetimeprograms.Itallows:b Creation of a new program with the possibility of copying to the other days,b Viewing programs in memory,b Modification of a program in memory, of the time, date, summer/winter time,b Partial or total deletion of the program (date, time and language are kept),b Modification of the brightness threshold,b Separate setting of the time delay on switch-on and switch-off.
MovetoOn/Offoverride (Fig. 3)b Press briefly (< 2 s) and simultaneously the 2 keys “-”, “+” (value setting and navigation keys) on the front face to move to “MAN ON” or “MAN OFF”.b Press the keys for more than 2 s to move to “PERM ON” or “PERM OFF”.b Supply of terminal 1 overrides the IC2000P+ output to the “On” position. This external override takes priority over the product On/Off override function.
Fig. 3
1
0
1
0
1
0
1
0
1
0 1
L
DB
�090
72
External input (On override)
Time switch function
BrightnessThreshold
IC function
IC2000P+ output
IC2000P+ output
PracticleadvicesIC2000P+
��UT0003�_03-2007_EN
TechnicaldataIC Astro
PB
�002
07-4
0 FunctionThe IC Astro astronomic programmable light sensitive switch is used to start and stop an electric load (e.g. lighting) according to sunrise and sunset times, without a brightness detector.Sunrise and sunset times are calculated automatically by the IC Astro according to the geographic parameters configured by the user.
DescriptionThe IC Astro is configured according to the place of installation.b The place of installation of the IC Astro can be configured:v either by selecting a country and a town,v or by its geographic coordinates (latitude, longitude).b The IC Astro allows:v addition or deletion of a switch-off/switch-on switching operation (Off-On) between the sunset and sunrise times,v different programmes each day,v difference in sunset and/or sunrise times, adjustable separately by ± �20 min. according to local constraints (mountains, buildings, etc.),v consideration of periods of absence (holidays), remote control of lighting override by a NO contact,v re-initialisation of programmes,v automatic switching to “summer-winter” time,v permanent display by liquid crystals: hours and minutes, day of the week, contact output status, and current programme,v manual waiver of the lighting On/Off programme, permanently or temporarily (up to the next switching operation).
Technicaldatab Memory: �4 switching operations (not including sunrise/sunset).b Minimum time between 2 switching operations: � min..b Switching accuracy: � s.b Time accuracy: ± � s /day.b Programming longitude: -�80° (East) to +�80° (West) in steps of �°.b Programming latitude: -90° (South) to +90° (North) in steps of �°.b Operating temperature: -20°C to +50°C.b Degree of protection: IP 20B.b Consumption: override input: < 0.5 mA.b Contact rating: v �6 A under 250 V AC (cos j = �), v �0 A under 250 V AC (cos j = 0.6). b Load table:Typeoflighting Max.power230 V incandescent and halogen lamps 2300 WNon-corrected/ serial-corrected fluorescent tubeswith conventional ballast
26 x 36 W, 20 x 58 W, �0 x �00 W
Parallel corrected fluorescent tubes with conventional ballast
�0 x 36 W, 6 x 58 W, 2 x �00 W
Dual-mounted fluorescent tubes with conventional ballast
�0 x (2 x 58 W), 5 x (2 x �00 W)
Fluorescent tubes with electronic ballast 9 x 36 W, 6 x 58 WDual-mounted fluorescent tubes with electronic ballast
5 x (2 x 36 W), 3 x (2 x 58 W)
Fluocompact lamps with electronic ballast 9 x 7 W, 7 x �� W, 7 x �5 W, 7 x 20 WParallel-corrected mercury and sodium vapour lamps 250 W
IC Astro
�2
Light sensitive switches
UT0003�_03-2007_EN
Connectionb Connection terminals: � screw connection per pole for cables up to 6 mm².
CataloguenumbersType Languages Cat.no.
IC Astro fr, gb, es, it, de, pt �5223fr, gb, se, dk/no, fi, nl �5224
DB
�092
�4
ConnectionandcataloguenumberIC Astro
On override external contact
�3UT0003�_03-2007_EN
ConfigurationThis consists of writing in the memory:b The languageb The place of installation, either:v by its position (Argentina, China, etc.) and by the closest town,v by its geographic coordinates (latitude, longitude, time difference with respect to GMT) (a map is provided with the product).b The year, month, day and time.
Once this phase is complete, your IC Astro will calculate the sunrise and sunset times and propose a default programme (operation from sunset to sunrise), for example:
Paris, 20th June, sunset �0 pm and sunrise 6 am.
ProgramminganOffperiodThe IC Astro offers the possibility of adding an “Off” period (programmed switch-off and switch-on) inside the programme, between the sunrise and sunset times (by default it is proposed from �� pm to 5 am), for example:
Modifying programming and configurationThe light sensitive switch allows:b Creation of a new customised programme with possibility of copying onto the other days,b Display of programmes in memory,b Deletion, modification or addition of an automatic or programmed switching operation, b Partial or total deletion of the programme (date, time and language are kept),b Modification of time, date, summer/winter time,b Temporary cancellation of the “On” periods by configuring start and end dates and Times of absence (holidays),b Adjustment of difference in sunset and/or sunrise times by ± �20 min. according to local constraints (mountains, buildings, etc.), for example:
MovetoOn/Offoverrideb Briefly press (< 2s) at the same time on the 2 keys “-”, “+”: (value setting and navigation keys) on the front face to move to “ON TEMP” or “OFF TEMP”.b Hold down (> 2s) the keys to move to “ON PERM” or “OFF PERM”.b The supply of input 5 forces the IC Astro output to the “ON” position. This override takes priority over the product On/Off override function.
DB
�000
48
PracticleadvicesIC Astro
DB
�000
50
DB
�000
5�
DB
�026
5�
DB
�000
49
�4
Light sensitive switches
UT0003�_03-2007_EN
DimensionsIC�00, IC200, IC2000, IC2000P+, IC Astro
Fixed externally in vertical position by 2 ø 4 mm screws
135-0601
Switchboardcell
135-0601
Wall-mountedcell,cat.no.15268 Wall-mountedcell,cat.no.CCT15268
94
3643.5
ø9
20ø9
Ø9
25
P93
868
015-0400
IC200
P93
87�
054-0601
IC100
P93
870
187-1003
IC2000P+,ICAstro
P93
873
P93
872IC2000
E�5
639-
BE
�564
0-B
�35-060�
Schneider Electric Industries SAS89, boulevard Franklin RooseveltF-92506 Rueil-Malmaison CedexTel: +33 (0)� 4� 29 85 00www.schneider-electric.com
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.