66
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved www.huawei.com Internal OWG001102 MSOFTX3000 Hardware System ISSUE 2.2

6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

  • Upload
    krit3

  • View
    928

  • Download
    47

Embed Size (px)

Citation preview

Page 1: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

www.huawei.com

Internal

OWG001102

MSOFTX3000 Hardware

System

ISSUE 2.2

Page 2: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved

� Upon completion of this course, you will

be able to:

�Understand MSOFTX3000 system

structure

�Master MSOFTX3000 board function

�Understand concatenation and cables.

COMPAQ
Note
su ghep noi
Page 3: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

References

� MSOFTX3000 Hardware Description Manual

� MSOFTX3000 Hardware Installation Manual

� MSOFTX3000 Technical Manual System

Description

Page 4: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

Chapter 1 MSOFTX3000 OutlineChapter 1 MSOFTX3000 Outline

Chapter 2 Board FunctionChapter 2 Board Function

Chapter 3 Concatenation and CablesChapter 3 Concatenation and Cables

Page 5: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

Chapter 1 Chapter 1 MSOFTX3000 OutlineMSOFTX3000 Outline

1.1 Device Introduction

1.2 System Structure

Page 6: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

External Interfaces of MSOFTX3000

� Serving as the control component in the UMTS R4 CN, such as Mobile

Switching Center (MSC) Server, Gateway MSC (GMSC) Server and

Tandem Mobile Service Switching Center (TMSC) Server, and providing

Service Switching Point (SSP) function.

MSOFTX3000 MSOFTX3000

SCP

RANAP BSSAP

CAPNc

RNC BSCUMG8900 UMG8900

Nb

Mc Mc

IuUP A

Page 7: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

MSOFTX3000 Cabinet

� MSOFTX3000 adopts N68-22 cabinet

� It includes integrated configuration and

Expansion configuration cabinet

� 600 mm (width)* 800 mm (depth)* 2200

mm (height) ;

� Four frames per cabinet

COMPAQ
Note
co, chap nhan
Page 8: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

Integrated Configuration Cabinet Expansion Configuration Cabinet Expansion Configuration Cabinet

MSOFTX3000 Cabinet

Expansion frame (9U)

Air deflector (2U)

Power distribution frame (2U)

Basic frame (9U)

Air deflector (2U)

Blank panel (2U)

Blank panel (2U)

KVMS(1U)

Cable through (1U)LAN Switch(1U)

LAN Switch(1U)

Cable through (1U)

Hard disk array (3U)

BAM(2U)

IGWB(2U)

IGWB(2U)

Blank panel (2U)

Expansion frame (9U)

Air deflector (2U)

Power distribution frame (2U)

Expansion frame (9U)

Air deflector (2U)

Expansion frame (9U)

Air deflector (2U)

Expansion frame (9U)

Air deflector (2U)

Expansion frame (9U)

Air deflector (2U)

Power distribution frame (2U)

Expansion frame (9U)

Air deflector (2U)

Expansion frame (9U)

Air deflector (2U)

Expansion frame (9U)

Air deflector (2U)

Page 9: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

MSOFTX3000 Frame�The MSC SERVER UNIT frame is designed in conformity with the IEC297

standard and has the following features.

�The frame is 19 inches wide and 8U high.

�The front boards and back boards are plugged into the backplane

of the frame. All cables are led out of the frame from the back.

�The frame accommodates 21 slots. The power boards (UPWR)

occupy four slots.

�The frame enables temperature

detection and fan speed adjustment functions.

COMPAQ
Note
phu hop
Page 10: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

MSOFTX3000 Frame

�Classification

�Basic frame

�The basic frame is configured in the fixed position in the integrated

configuration cabinet, providing clock interface, IP interface and

E1 interface and implementing service processing.

W

CD

B

W

CD

B

0

0 1

W

IF

M

2

W

IF

M

3 4 5 6 7

W

SM

U

8 9 10

W

IF

M

11

W

MG

C

12

W

MG

C

13 14 15

1

WB

FI

2

WB

FI

3

WB

AI

4

WB

AI

5

WS

IU

6

WH

SC

7

MH

SC

9

WS

IU

8 10

WC

KI

11 12 13 14 15

Backplane

Front

boards

Back

boards

WB

FI

WB

FI

W

AF

M

W

AF

M

W

CD

B

W

CD

B

WC

KI

W

SM

U

W

I

F

M

W

AL

U

16

U

PW

R

17 18 19 20

UP

WR

16

UP

WR

17 18 19 20

U

PW

R

Page 11: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

MSOFTX3000 Frame� Expansion frame

� The expansion frame is the service processing frame customized

according to the subscriber capacity, and it coordinates with the

basic frame to implement service processing.

WCS

U

WCS

U

WE

PI

WE

PI

0

0 1

WCS

U

2

WCS

U

3 4 5 6 7

WSM

U

8 9 10

WCC

U

11

WVD

B

12

WVD

B

13 14 15

1

WE

PI

2

WE

PI

3

WE

PI

4

WE

PI

5

WS

IU

6

WH

SC

7

WH

SC

9

WS

IU

8 10 11 12 13 14 15

Backplane

Front

boards

Back

boards

WCS

U

WCS

U

WBS

G

WBS

G

WSM

U

WC

CU

WAL

U

16

UPW

R

17 18 19 20

UP

WR

16

UP

WR

17 18 19 20

UPW

R

Page 12: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

Connection of Different Frames

Frame 0#

Frame 1#

Frame 2#

Frame 9#

LAN Switch in

plane 1

LAN Switch in plane 0

Standby iGWB

FE

GEActive iGWB

BAM

FE

Host Background

To the billing center

WS WS WS

HubTo the network

Management center

FE

To the billing center

Emergency WS

Frame 0#

Frame 1#

Frame 2#

Frame 9#

LAN Switch in

plane 1

LAN Switch in plane 0

Standby iGWB

FE

GEActive iGWB

BAM

FE

Host Background

To the billing center

WS WS WS

HubTo the network

Management center

FE

To the billing center

Emergency WS

Page 13: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

Chapter 1 Chapter 1 MSOFTX3000 OutlineMSOFTX3000 Outline

1.1 Device Introduction

1.2 System Structure

Page 14: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

Logical Structure of the System

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

Page 15: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

Chapter 1 MSOFTX3000 OutlineChapter 1 MSOFTX3000 Outline

Chapter 2 Board FunctionChapter 2 Board Function

Chapter 3 Concatenation and CablesChapter 3 Concatenation and Cables

Page 16: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

Chapter 2 Chapter 2 Board FunctionBoard Function

2.1 System Support Module

2.2 Interface Module

2.3 Low Layer Processing Module

2.4 Service Processing Module

2.5 Other

2.6 Signaling Path

Page 17: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

System Support Module

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

Page 18: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

WSMU�The System Management Unit (WSMU) is the

main control board of the MSC SERVER UNIT

frame Configuring shared resource bus and

managing its status.

�Managing all boards in the frame and get

boards work status and report to the BAM.

�Controlling the indicators on the front

panel of the WALU.

�Loading and managing system programs

and data.

LINK ACT

RST

HUAWEI

COM

ALM RUN

DOMA DOMB

WSMU

Page 19: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

WSMU-Share Resource BUS�WSMU will manage all boards in same frame and help boards

(WIFM/WAFM/WBSG/WSGU/WCCU/WCSU/WCDB/WVDB) to load

relative data and application through Share resource BUS.

W

S

I

U

W

H

S

C

WS

I

U

W

H

S

C

WS

MU

SLOTNUMBER

Shareresource BUS

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

WS

MU

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

FR

ON

T

Page 20: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved

WSMU-Ethernet BUS

� Signaling process unit and service process unit

(WCDB,WVDB,WCCU,WCSU,WIFM,WBSG)will use Ethernet BUS to

transmit signaling and service information.

Page 21: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

WSMU-Serial Port BUS

� The Serial port BUS controls those boards in the frame that are

controlled by CPU but not connected to the shared resource bus, such

as WCKI, WEPI and WALU.

W

S

M

U

W

A

L

U

W

S

I

U

Serial port BUS

W

H

S

C

W

S

I

U

W

H

S

C

W

S

M

U

W

S

M

U

W

A

L

U

W

S

I

U

W

H

S

C

W

S

I

U

W

H

S

C

W

S

M

U

W

S

M

U

W

A

L

U

W

S

I

U

W

H

S

C

W

S

I

U

W

H

S

C

W

S

M

U

BACK

BACK

BACK

BACK

BACK

BACK

BACK

BACK

BACK

BACK

BACK

BACK

Page 22: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

WSIU

� It is fixedly installed in back slots 6 and 8 in each frame

�Providing Ethernet interface to the WSMU. It is

configured correspondingly to the WSMU one by one.

�providing physical interfaces to two asynchronous

serial ports.

�Implementing frame number identification through

setting DIP switch.

HD

10/100BT2

COM3+

COM3

10/100BT1

WS IU

HUAW EI

Page 23: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

WSIU-Frame Number Switch

offononoffonononon9

onononoffonononon8

offoffoffononononon7

onoffoffononononon6

offonoffononononon5

ononoffononononon4

offoffonononononon3

onoffonononononon2

offononononononon1

onononononononon0

12345678Frame Num

Page 24: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

WHSC�The Hot-Swap and Control unit (WHSC) is a back board in the

MSC SERVER UNIT frame

�WHSC is fixedly in back slots 7 and 9 of each frame

�Bridging left and right shared resource buses, for the

purpose of assuring that the WSMUs in slots 6 and 8

can respectively manage the front boards

�Controlling hot-swap of boards,

�Providing two pairs of heartbeat detection interfaces

for the WSMU/WHSC

�Providing a 10M/100M compatible Ethernet

connection between the active WSMU and the standby

one

�Providing six FE ports externally.

�The WHSC is working in 1+1 backup mode.

10/100BT1

DOMA DOMB

10/100BT2

10/100BT3

10/100BT4

10/100BT5

10/100BT6

HUAWEI

WHSC

Page 25: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

WHSC-Ethernet Double Plane Structure

WHSC 0

WSIU 0

W

S

M

U

0

WSIU1

W

S

M

U

1

WHSC 1

External cable

WHSC 0 WHSC 1

WSIU 0 WSIU1

W

S

M

U

0

W

S

M

U

1

intra cableintra cable

LANSwitch 0 LANSwitch 1

intra cable intra cable

External cable

External cable

External cable

intra cableintra cable intra cable intra cable

Page 26: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

Chapter 2 Chapter 2 Board FunctionBoard Function

2.1 System Support Module

2.2 Interface Module

2.3 Low Layer Processing Module

2.4 Service Processing Module

2.5 Other

2.6 Signaling Path

Page 27: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

Interface Module

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

Page 28: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

WIFM/WBFI�WIFM

�The IP Forward Module (WIFM) is used to

receive and transmit IP packets, process Media

Access Control (MAC) layer messages and

distribute IP messages.

�WBFI

�The Back Insert FE Interface Unit (WBFI) is

the back interface board of the WIFM. It is used

to perform FE driving, and provide external

physical interfaces for the WIFM. It is

configured correspondingly to the WIFM one by

one.

�The WBFI works in 1+1 backup mode.

LINK ACT

HUAWEI

COM

ALM RUN

RST

WIFM

10/100BT

HUAWEI

WBFI

Page 29: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

WAFM/WBAI

� WAFM

� Along with the WBAI, provides ATM interface to

perform ATM Adaptation Layer 5 (ATM AAL5)

Segmentation And Reassembly (SAR) processing

� Distribute the packets to the proper WBSG according

to the Permanent Virtual Connection (PVC)

configurations.

� WBAI

� It is used to perform ATM driving and provide ATM

STM-1 physical interfaces.

� The WBAI works in 1+1 backup mode.

TX

RX

MM

HUAWEI

WBAI

LINK ACT

HUAWEI

COM

ALM RUN

RST

WAFM

Page 30: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

WCKI�The WCKI is used to provide stratum-2 and stratum-3 standard

synchronization clocks for system networking purpose and stable and

precise clock signals to the system.

�The WCKI works in 1+1 hot-backup mode.

W

C

K

I

(M)

W

C

K

I

(S)

W

E

P

I

(M)

W

E

P

I

(S)

W

E

P

I

(M)

W

E

P

I

(S)

W

E

P

I

(M)

W

E

P

I

(S)

BITS BITS

8k clock cable 8k clock cable

Basic subrack

Expansion subrack

···

COMPAQ
Note
tang, lop
Page 31: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

WEPI

� WEPI

� Providing narrowband signaling physical interfaces for the WCSU. It is

configured correspondingly to the WCSU one by one.

� Processing MTP1 physical layer messages.

� Transferring system clock signals and providing clock synchronization in

the frame.

�Working with the WCSU to implement active/standby switchover through

H.110 bus.

Page 32: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

WSMU

H.110 bus

WSIU

WHSC

BB

WSIU

WHSC

WSMU

BB

BB

BB

BB

BB

BB

BB

BB

BB

BB

BB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

WSMU

H.110 bus

WSIU

WHSC

BB

WSIU

WHSC

WSMU

BB: Back board

FB: Front board

BB

BB

BB

BB

BB

BB

BB

BB

BB

BB

BB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

FB

WEPI-H.110 Bus

� Realize WCSU active/standby switchover

� Transferring system clock signals for other boards in the same frame

WCSU0

WEPI 0

8×E1

WEPI1

WCSU1

Intra HW bus

Page 33: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

Chapter 2 Chapter 2 Board FunctionBoard Function

2.1 System Support Module

2.2 Interface Module

2.3 Low Layer Processing Module

2.4 Service Processing Module

2.5 Other

2.6 Signaling Path

Page 34: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

Low-layer Signaling Processing Module

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

Page 35: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

WBSG�Mainly used to process IP packets after the WIFM level 1 distribution

� Implement coding/decoding for lower layer signaling transmission

protocols (UDP, TCP, SIGTRAN, MTP3 and MTP3b) and H.248 bearer

control protocol

�Perform level 2 message distribution to corresponding service processing

units for transaction layer/service layer processing.

M3UA

MTP3

SCTP

/TCP

/UDP

SAAL MTP3b H.248

IP Driver

MAC

/IP

ATM Driver

AAL5

SAR

WBSG

WIFM

WAFMWBAI

WBFI

Page 36: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

Chapter 2 Chapter 2 Board FunctionBoard Function

2.1 System Support Module

2.2 Interface Module

2.3 Low Layer Processing Module

2.4 Service Processing Module

2.5 Other

2.6 Signaling Path

Page 37: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

Service Process Module

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

NMS

WEPIWEPI

WSIU/WSMUWSIU/WSMU

WIFMWIFM

WAFMWAFM

WCKIWCKI

CPCCPC

WCCUWCCU

WBSGWBSGWHSC

WMGCWMGC

BUS

iGWBiGWB

BAM

IM SLLPM SPMOMM

LANSwitch

WS

WS

IP

ATM

BITS

E1

BC

0#

9#

SSM

WCDB

WVDB

Page 38: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved

WCCU/WCSU�The Calling Control Unit/Calling Control and Signaling process Unit

(WCCU/WCSU) is responsible for call control and protocol processing of

MTP3, MTP3b, M3UA, ISUP, BSSAP, MAP and CAP.

SCCP

TCAP

I

S

U

P

R

A

N

A

P

B

S

S

A

P

+

M

A

P

C

A

P

MTP3

MTP3b

BICC H.248

M3UA

B

S

S

A

P

MTP2

WEPISCTP

SAALIP

M3UA MTP3b

WBSG

WCSU

WCCU

H.248

SCCP

TCAP

I

S

U

P

R

A

N

A

P

B

S

S

A

P

+

M

A

P

C

A

P

MTP3

MTP3b

BICC H.248

M3UA

B

S

S

A

P

MTP2

WEPISCTP

SAALIP

M3UA MTP3b

WBSG

WCSU

WCCU

H.248

Page 39: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved

WCDB

� It provides UMG resource management, outgoing trunk selection, and

WVDB distribution agent management (MSRN number allocation, WVDB

maintenance command forwarding) functions.

� The WCDB contains global data which can be accessed by all

WCCUs/WCSUs and WVDBs.

� Because the WCDB is an accessed center, its load is relatively large. In

small-capacity configuration mode, its functions can be implemented by

one pair of WCDBs.

� In a large-capacity configuration mode, different functions must be

distributed to different WCDBs.

Page 40: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved

WVDB

� The VLR Database Board (WVDB) is a front board used to store the

subscription data of mobile subscribers.

� In a large-capacity application, multiple pairs of WVDBs are required to

store the subscription data.

� The subscription information of one subscriber is stored in the same pair

of WVDBs.

� The principles for distributing subscriber data on different WVDBs have

been described in the Section about WCDB (also named WVDB

distribution agent function).

� Such distribution is transparent for the WCCU/WCSU service layer.

Page 41: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved

WMGC

� WMGC provides gateway registration, internal link status maintenance,

gateway status and capability auditing, and gateway exception handling

functions.

Page 42: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 42All rights reserved

Chapter 2 Chapter 2 Board FunctionBoard Function

2.1 System Support Module

2.2 Interface Module

2.3 Low Layer Processing Module

2.4 Service Processing Module

2.5 Other

2.6 Signaling Path

Page 43: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 43All rights reserved

WALU&UPWR

�The Alarm Unit (WALU) is a front board installed fixedly in slot 16 in

each MSC SERVER UNIT frame. Its functions are as follows:

�Acting as a slave node, communicating with the master

node (WSMU) through serial port bus, and controlling

indicator under the instructions of the WSMU.

�UPWR

�It is used to provide power supply to the boards in the MSC

SERVER UNIT frames.

�The UPWR works in 2+2 backup mode.

Page 44: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 44All rights reserved

Chapter 2 Chapter 2 Board functionBoard function

2.1 System Support Module

2.2 Interface Module

2.3 Low Layer Processing Module

2.4 Service Processing Module

2.5 Other

2.6 Signaling Path

Page 45: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 45All rights reserved

Signaling Processing Path over TDM

W

S

M

U

W

S

I

U

W

H

S

C

W

E

P

I

W

S

I

U

W

E

P

I

W

C

S

U

W

S

M

U

W

C

S

U

W

C

C

U

W

C

C

U

W

H

S

C

Ethernet BUS

E1

H.110 BUS

Core LAN Switch Core LAN Switch

FE FE

FRAME A

Page 46: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 46All rights reserved

Signaling Processing Path over IP

W

S

M

U

W

S

I

U

W

H

S

C

W

B

F

I

W

S

I

U

W

B

F

I

W

I

F

M

W

S

M

U

W

I

F

M

W

M

G

C

W

M

G

C

W

H

S

C

Ethernet Bus

FE

Shared Resource Bus

Core LAN Switch Core LAN Switch

FE FE

FRAME A

W

B

S

G

W

B

S

G

W

C

C

U

W

C

C

U

FE

Service_change

Other

Message

Page 47: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 47All rights reserved

Signaling Processing Path over ATM

W

S

M

U

W

S

I

U

W

H

S

C

W

B

A

I

W

S

I

U

W

B

A

I

W

A

F

M

W

S

M

U

W

A

F

M

W

M

G

C

W

M

G

C

W

H

S

C

Ethernet Bus

ATM STM-1

Shared Resource Bus

Core LAN Switch Core LAN Switch

FE FE

FRAME A

W

B

S

G

W

B

S

G

W

C

C

U

W

C

C

U

ATM STM-1

Service_change

Other

message

Page 48: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 48All rights reserved

Signaling Process Flow Summary

� TDM:

WEPI→CPC→WCCU

� IP:

WBFI→WIFM→WBSG→WMGC

WBFI→WIFM→WBSG→WCCU

� ATM:

WBAI→WAFM→WBSG→WMGC

WBAI→WAFM→WBSG→WCCU

ReviewReview

Page 49: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 49All rights reserved

MSOFTX3000 Locks Clock Signal of Reference Source

W

C

K

I

W

E

P

I

W

C

K

I

W

E

P

I

E1

Basic frame

B

I

T

S

1

MS¸

H.110 BUS

MS

B

I

S

0

T

Page 50: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 50All rights reserved

Expansion Frame Locks Clock Signal of Basic Frame

W

E

P

I

W

E

P

I

Expansion frame

MS¸

H.110 BUS

W

C

K

I

W

E

P

I

W

C

K

I

W

E

P

IMS¸MS¸

W

E

P

I

W

E

P

IMS¸

Basic frame

Page 51: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 51All rights reserved

Alarm Path

W

S

M

U

S

W

A

L

U

W

S

I

U

Serial Port Bus

W

H

S

C

W

B

A

I

W

S

I

U

W

H

S

C

W

B

F

I

U

P

W

R

U

P

W

R

W

S

M

U

M

U

P

W

R

U

P

W

R

W

A

F

M

W

I

F

M

Shared Resource

Bus B

Shared Resource

Bus B

BAM

Back Board

Back Board

Back Board

Back Board

Back Board

Back Board

Back Board

Back Board

Page 52: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 52All rights reserved

Loading Path

BAM

LANSwitch LANSwitch

WCDB/WVDB/WCC

U/WCSU/WBSG/WM

GC/WAFM/WIFM

W

H

S

C

W

H

S

C

W

S

M

U

W

S

M

U

Share resource BUS

Page 53: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 53All rights reserved

Charging Path

H

S

C

WCCU/WCSU

Host bill pool

WCCU/WCSU

Host bill pool

L

A

NiGWB

Billing Center/

Billing Collector

H

S

C

Page 54: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 54All rights reserved

Questions

� How many boards are there in MSOFTX3000?

� What’s the function of each board?

Page 55: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 55All rights reserved

Chapter 1 MSOFTX3000 OutlineChapter 1 MSOFTX3000 Outline

Chapter 2 Board FunctionChapter 2 Board Function

Chapter 3 Concatenation and CablesChapter 3 Concatenation and Cables

Page 56: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 56All rights reserved

Connection between WHSC and LAN Switch

� The ports labeled 10/100BT6 at the uppermost position of the active and

standby WHSC boards are connected to the active and standby LAN

Switches respectively through straight through network cables

LAN SwitchLAN Switch

Page 57: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 57All rights reserved

Connection between WHSC and WSIU� Straight through network cable is used as FE signal cable to connect

the WHSC and the WSIU.

Page 58: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 58All rights reserved

Server/Switcher Cables

� Server/switcher cables include keyboard cable, mouse cable and display

cable delivered along with the device.

� The connection relations are “BAM-PC1”, ”iGWB0-PC2” and “iGWB1-PC3”.

iGWB0

KVM/LCD switcher

iGWB1

BAM

PC3 PC2PC4 PC1

Page 59: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 59All rights reserved

Clock Cable Distribution of MSOFTX3000

W

C

K

I

(M)

W

C

K

I

(S)

W

E

P

I

(M)

W

E

P

I

(S)

W

E

P

I

(M)

W

E

P

I

(S)

W

E

P

I

(M)

W

E

P

I

(S)

BITS BITS

8k CLOCK CABLE 8k CLOCK CABLE

BASIC FRAME

SERVICE FRAME

···

Page 60: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 60All rights reserved

Installation of External Clock Cable

� The external clock cable is used to connect external BITS clock device

� The 75 ohm SMB connector is adopted as the cable connector

Page 61: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 61All rights reserved

Installation of External Clock Cable

1 2

3 4

5 6

7 8

9 10

11 12

13 14

15 16

BITS1

BITS2

LINE1

LINE2

WCKI

1 2

3 4

5 6

7 8

9 10

11 12

13 14

15 16

BITS1

BITS2

LINE1

LINE2

WCKI BITS1 BITS2

Page 62: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 62All rights reserved

Installation of Intra Clock Cable

� Connection of 2M clock cable

Page 63: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 63All rights reserved

Installation of Intra Clock Cable

� WCKI board provides other frames not configured with clock boards

with 16 channels of 8 kHz clock sources through 8 kHz internal clock

cable,

Page 64: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 64All rights reserved

Installation of Monitoring Cable

� one end of the cable is connected to the serial port socket of

the power distribution monitor board behind the power

distribution frame, and the other end is connected to the

monitor port COM3 of WSIU board.

Page 65: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

HUAWEI TECHNOLOGIES CO., LTD. Page 65All rights reserved

Summary

� Understand MSOFTX3000 system structure

� Master MSOFTX3000 board function

� Understand concatenation and cables

ReviewReview

Page 66: 6913859 Microsoft Power Point 00OWG001102 MSOFTX3000 Hardware System ISSUE22

www.huawei.com