19
Panel Door Ø48 Ø4.5 Ø12 I II O Ø64 LOAD BREAK SWITCHES LOAD BREAK SWITCHES S Sw wi it tc ch h o on n t to o t th he e b be es st t

Ø64 LOAD BREAK - 3.imimg.com

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ø64 LOAD BREAK - 3.imimg.com

Panel Door

Ø48

Ø4.5 Ø12

I II

O

Ø64LOAD BREAK SWITCHES

LOAD BREAK SWITCHES

SSwwiittcchh oonn

ttoo tthhee bb

eesstt

Page 2: Ø64 LOAD BREAK - 3.imimg.com

GENERAL

LB Series Load Break Switches comply with the latest specifications for modern low voltage devices.

Outstanding electrical characteristics of LB Switches with compact design, contribute to space saving installation and operational convenience.

Basic construction and design of the switch makes it compact, safe and highly reliable.

The switch uses polyamide glass filled material, having excellent track resistance (CTI) for Insulation to prevent flashover between phases in the most severe conditions.

The special contact design and configuration makes the switch highly reliable to withstand high short circuit currents.

FEATURES�Double break contacts.

�Polycarbonate shroud for wired terminal protection is included.

�Excellent switching and high short circuit capacity.

�Compact and reliable.

�Easy installation.

�Different mounting options, i.e. front mounting, rear mounting and enclosure mounting.

�Provision to fix on DIN Rail for rear mounting Switches.

�Quick, simple and convenient,dia. 22.5 mm single hole mountingis offered for 16A/20A switches with padlocking option.

�Open terminals for easy access.

�Finger protection.

�Terminal screws with fixed clamp for easy wiring.

�Add-on main/neutral/auxiliary contacts can be mounted on bothsides of the switch.

4th Pole addition is possible at site.

Contents PageNo.

General

Technical Data 1

Switching Programmes 2

Front Mounting 3

Rear Mounting 5

Plastic Enclosure Mounting 7

Metal Enclosure Mounting 8

Accessories 10

Changeover Switches 13

Enclosure Changeover Switches 15

Product Coding 16

INDEX

®

APPLICATIONS�

�Motor Start and Stop.

�Manual Motor controller as Motor Disconnect.

�Main Switch.

�Emergency ON-OFF.

�Control Switch.

�Changeover Switch.

APPROVALS�For Canada and US.

�For Europe

Please refer to us for updated status on the approvals and listings.

Isolator.

Page 3: Ø64 LOAD BREAK - 3.imimg.com

1

TECHNICAL DATA

CSA STANDARD CAN/CSA-C22.2 N0.14-M91

UL STANDARD UL508

EUROPEAN STANDARD IEC947-1 and 3, EN60947, VDE 0660-107

AC-23A,3 PHASE, 3 POLE

AC-3,3 PHASE, 3 POLE

IEC/EN/VDE

IEC/EN/VDE

DOL

1.5 1.5

RATING Measure LB116 LB120 LB225 LB232 LB240 LB263 LB4080 LB4100

Rated Operational Voltage, Ue

IEC/EN/VDE Volts V 690 690 690 690 690 690 690 690 690

UL/CSA Volts V 600 600 600 600 600 600 600 600 600

Main Switch: Isolating Voltage Upto Volts V 750 750 750 750 750 750 750 750 750

Resistance to Surge PulseVolts kV 6 6 6 6 6 6 6 6 6Voltage, Uimp

Rated Uninterrupted Current, Iu Amp A 16 20 25 32 40 63 80 100 125

Rated Operational Current, Ie

AC22 Amp A 16 20 25 32 40 63 80 100 125

AC-21A IEC/EN/VDE Amp A 16 20 25 32 40 63 80 100 125

AC-1 Amp A 20 25 32 40 63 80 80 100 125

UL/CSA Amp A 16 20 25 32 40 63 80 100 125

Rated Operational Power at 50 to 60Hz (IEC/EN/VDE)220-240V kW 3 4 5.5 7.5 11 15 18.5 22 30

380-440V kW 5.5 7.5 11 15 18.5 30 30 37 45

500-690V kW 7.5 11 11 15 22 30 37 45 55

220-240V kW 2 3 4 5.5 7.5 11 15 18.5 22

380-440V kW 3 5.5 7.5 11 18.5 22 22 30 37

500-690V kW 5.5 7.5 11 11 18.5 22 30 37 45Short Circuit Capacity (IEC/EN/VDE)Max. Fuse Size (Type gL) Amp A 16 25 25 32 40 63 80 100 125Rated fused short circuit current Amp kA 5 5 30 30 30 30 30 30 30

UL/CSA Power Rating: Manual Motor Controller, Suitable as Disconnect

120V HP 3 3 5 7.5 5 7.5 7.5

240V HP 3 3 7.5 7.5 10 15 10 15 15 3 PHASE, 3 POLE480V HP 7.5 7.5 15 20 20 25 30 30 40

600V HP 10 10 20 25 30 30 40 40 50

120V HP 0.5 0.5 1.5 2 3 3 3 3 3 1 PHASE240V HP 1.5 1.5 2 3 4 7.5 7.5 7.5 10

Short Circuit Capacity (UL/CSA)

Max. Fuse Size Amp A 25 25 50 50 70 70 100 100 125

Fuse Rating, J Type Amp A 20 20 45 45 70 70 90 90 90Rated used Short ircuit urrent Amp kA 10 10 10 10 10 10 10 10 10 F C CTerminal Cross Section

2 Min-mm 1.5 1.5 1 1 4 4 6 6 6Single/Multiple Strand Wire 2Max-mm 6 6 10 10 16 16 70 70 70

2 Min-mm 0.5 0.5 0.75 0.75 2.5 2.5 4 4 4Fine-Strand Wire with Sleeve 2Max-mm 6 6 6 6 10 10 50 50 50

American Wire Guage - AWG 12 12 8 8 6 6 1 1 1

Recommended Tightening - Nm 0.8 0.8 1.7 1.7 1.7 1.7 2.5 2.5 2.5Torque

LB4125

Page 4: Ø64 LOAD BREAK - 3.imimg.com

2

SWITCHINGPROGRAMMES

SWITCHING PROGRAMMES

Switches : LB225, LB232, LB240, LB263, 4080, 4100, 4125LB LB LB

3 Pole + 4 Pole +3 Pole 6 Pole 8 Pole1 Main Module 1 Main Module

31300 31400 31500 31600 31800

31309 31409 31509 31609 31809

Switches: LB4080, LB4100, LB4125

31309 31409 31509 31609 31809

31319 31419 31329 31429 31339 31349

31319 31419 31329 31429 31339 31349

3 Pole+ 4 Pole+ 3 Pole+ 4 Pole+ 3 Pole+ 3 Pole+1 Neutral 1 Neutral 1 Auxillary 1 Auxillary 2 Neutral 2 Auxillary Module Module Module Module Modules Modules

31310 31410 31320 31420 31330 31340

Note: 6P and 8P for LB116 and LB120 are under development. Please refer to us

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

7

8

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

7

8

9

10

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

1/L1

2/T1

3/L2

4/T2

5/L3

6/T3

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

3/L2

4/T2

5/L3

6/T3

7

8

7

8

3/L2

4/T2

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

N

N

1/L1 3/L2

2/T1 4/T2

5/L3

6/T3

N

N

7

8

1/L1 3/L2

2/T1 4/T2

5/L3

6/T3

21

22

13

14

1/L1 3/L2

2/T1 4/T2

5/L3

6/T3

7

8

21

22

13

14

1/L1 3/L2

2/T1 4/T2

N

N

N

8

5/L3

6/T3

21

22

13

14

1/L1 3/L2

2/T1 4/T2

5/L3

6/T3

21

22

13

14

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

7

8

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

7

8

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

5/L3

6/T3

3/L2

4/T2

1/L1

2/T1

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

5/L3

4/T2

3/L2

6/T6

3/L2

4/T2

7

8

7

8

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

N

N

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

7

8

N

N

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

21

22

13

14

7

8

21 1/L1

22 2/T1

13

14

5/L3

6/T3

3/L2

4/T2

N

N

N

N

1/L1 3/L2 5/L3

2/T1 4/T2 6/T3

21 1/L1

22 2/T1

13

14

5/L3

6/T3

3/L2

4/T2

21

22

13

14

9

10

Page 5: Ø64 LOAD BREAK - 3.imimg.com

FRONT MOUNTING

3All dimensions in mm.

� Dia 22.5mm, single hole panel mounting.

Front IP55.Degree of protection :

B03 16A-20A

� 4 hole front panel mounting.�

Front IP55.Degree of protection :

��FIFTH POLE CAN BE FITTED ON THE OTHER SIDE OF THE SWITCH

SQ.48

16

57

46 3mm

PANEL GAP

30

36SQ Ø4.5

Ø12

PANEL PLATE

B19 16A-20A

SQ.48

16

46

57

100

31.7

� 4 hole, front panel mounting.

� Switch with padlockable flag knob.

Front IP55.Degree of protection : � Max. 1 padlock.

B40 16A-20A

SQ.48

16

57

46 3mmPANEL GAP

Shackle sizemin. 2mm, max. 6mm

31

36SQ Ø4.5

Ø12

PANEL PLATE

B13

��FIFTH POLE CAN BE FITTED ON THE OTHER SIDE OF THE SWITCH

� 4 hole front panel mounting. �

Front IP55.Degree of protection :

25A-63A

15

72

56

4

3 (MAX)PANEL GAP

3018

SQ.64

Ø12

Ø4.5PANEL PLATE

SQ.48FOURTHPOLE

50 18

Page 6: Ø64 LOAD BREAK - 3.imimg.com

FRONT MOUNTING

B30

B33

��FIFTH POLE CAN BE FITTED ON THE OTHER SIDEOF THE SWITCH

device to prevent from being switched ON by unauthorised personnel.

Max 3 padlocks.�

4 hole front panel mounting.

Degree of protection : Front IP65.

Switch with round padlocking

25A-63A

4 hole front panel mounting.

Degree of protection : Front IP55.

Switch with rectangular

padlocking device to prevent the Switch from being switched ON by unauthorised personnel.

Max 4 padlocks.�

25A-63A

��FIFTH POLE CAN BE FITTED ON THE OTHER SIDEOF THE SWITCH

All dimensions in mm.4

Notes:

B63

4 hole front panel mounting.

Degree of protection : Front IP55.

� Knob operated, keylock, key removable in OFF position. (Other options on request)

25A-63A

��FIFTH POLE CAN BE FITTED ON THE OTHER SIDEOF THE SWITCH

15

72

72

3 (MAX)PANEL GAP

30 50 18

SQ.64FOURTHPOLE

PANEL PLATE

Ø23

SQ.48Ø5.5

Ø12

43.5

SQ.64

15

72

56

3 (MAX)PANEL GAP

30Ø5.5

23

4

7550

18

13.5 FOURTHPOLE

102

Ø12

PANEL PLATE

SQ.48

Page 7: Ø64 LOAD BREAK - 3.imimg.com

REAR MOUNTING

5All dimensions in mm.

B23

25A-63A�

mounting on DIN EN50022 rail (35mm) and operable from thefront (door) - coupled with doormechanism.

Door interlock (Door openable onlyin 0FF position.)

Degree of protection :Front IP55.

2 hole rear mounting or snap

MB42 16A-20A

TO SUIT M4 SCREW

35

36

64

72 57

47

204 3mmPANEL GAP

SQ48

16

MOUNTING RAIL

80A-125A

25A-63A

2 hole rear mounting. Alternately snap mounting on

DIN EN50022 rail (35mm).

Front IP30.Degree of protection :

MOUNTINGRAIL FOURTH POLE

35 65

1572

62.5 2452.5

50 18

46

SUITABLE FORM4 SCREW

94 104

84

35

25

ALARRANGEMENTTERNATE FIXING

LOCK SCREW

M5 SCREWTO SUIT

SQ.64PANEL GAP5(MAX.)

SQ.488

PANEL DOOR

Ø4.5Ø12

338

37.5

I

O

MOUNTINGRAIL

80A-125A

104

84

SQ.48

102 73

36

9435

25

ALARRANGEMENTTERNATE FIXING

M5 SCREWTO SUIT

MOUNTINGRAIL

64

18 50(L) 18

7235 65

355

85

3(Max)37.5

Ø48

Ø4.5 Ø12

OONNOOFFFF

ALTERNATIVE FIXINGARRANGEMENT

MOUNTINGRAIL M4 SCREW

TO SUIT

LOCK SCREW

PANEL GAP

PANEL DOOR

Page 8: Ø64 LOAD BREAK - 3.imimg.com

6All dimensions in mm.

REAR MOUNTING

MB34 16A-20A

25A-63A

80A-125A

mounting on DIN EN50022 rail (35mm) and operable from the front (door) coupled with door mechanism.

Door interlock (door openable only in OFF position).

Degree of protection : Front IP65.

Rigid metal shaft/switch assembly.

Switch with round padlocking device to prevent the Switch frombeing made ON by unauthorisedpersons.

Max.3 padlocks as under.16A-20A: Max. 1 padlock25A-63A: Max. 2 padlocks80A-125A: Max. 3 padlocks

2 hole rear mounting or snap

� Adjustable mounting by cutting the metal shaft to appropriate length, to suit panel height.

be offered on request. Specific Length of shaft can

36SQ Ø4.5

Ø12

PANEL PLATE

MOUNTINGRAIL

TO SUIT M4 SCREW

36

64 72 57

47

204 3mmPANEL GAP

SQ48

16

35

ø12 ø4.5PANEL DOOR

SQ

.36

ALTERNATE FIXING ARRANGEMENT

MOUNTING RAILTO SUIT

M5 SCREW

25

35 104

94

84

LOCK SCREW

77.5

338

3(Max)

PANEL GAP42

SQ

.64

SUITABLE FORM4 SCREW 15

35 65 72

MOUNTINGRAIL

85

355

LOCK SCREW

3 MAXPANEL GAP

32

18 50 18

FOURTH POLE

SQ64

PANEL DOOR

SQ36

ø4.5 ø12

Notes:

Page 9: Ø64 LOAD BREAK - 3.imimg.com

PLASTIC ENCLOSUREMOUNTING

7All dimensions in mm.

Switch mounted in ABS / polycarbonate (optional) enclosure.

Round padlocking device (Max.3 padlocks) to prevent the Switch from being made to ON by unauthorised personnel.

Knob version available on request.

Switch rear mounted for easy connection.

B31SM

Round padlocking device (Max.3 padlocks) to prevent the Switch from being made to ON by unauthorised personnel.

Degree of protection : IP65.

Switch rear mounted for easy connection.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

Enclosure colour : Dark grey baseand light grey cover.

Fourth and Fifth pole can beadded.

� Switch mounted in ABS enclosure,optional in polycarbonate.

B31M 40A-63A

25A-32A

115

SQ.80

KNOCKOUT ( ø16mm)-2 PLACES

KNOCKOUT -M20(4PLACES) SUITABLE FOR M4 SCREW

72 42 100

125

KNOCKOUT -M254PLACES

SUITABLE FOR M4 SCREW

90 42

125

175

105

155

ø4.5

16A-20A

Degree of protection : IP65.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

Enclosure colour : Dark grey base and light grey cover.

Fourth pole can be added.

Switch mounted in ABS / polycarbonate (optional) enclosure.

Padlocking device (Max.3 padlocks)to prevent the Switch from being

made to ON by unauthorisedpersonnel.

Degree of protection : IP65.

Switch rear mounted for easy connection.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

Interlock provided to open the lid only in OFF position.

Enclosure colour : Grey.

Fourth and fifth pole can be added.

B31L 80A-125Aø25-4Nos.(BOTH SIDE)

33 33 130

168

190

280

258

ø6.5

115

SQ.80

KNOCKOUT ( ø16mm)-2 PLACES

KNOCKOUT -M20(4PLACES) SUITABLE FOR M4 SCREW

70 100

125

Page 10: Ø64 LOAD BREAK - 3.imimg.com

METAL ENCLOSUREMOUNTING

8All dimensions in mm.

Enclosure colour : Dark grey base and light grey cover.

Fourth pole can be added.

from being made to ON by unauthorised personnel.

Degree of protection : IP53.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

Switch mounted in aluminiumenclosure.

Round padlocking device (max. 3 padlocks) to prevent the Switch

AB31M

Switch mounted in aluminiumenclosure.

Round padlocking device (max. 3 padlocks) to prevent the Switch

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

Enclosure colour : Dark grey base and light grey cover.

from being made to ON by unauthorised personnel.

Degree of protection : IP53.�

AB31S Upto 25A

4474

Ø20-2 Places

ON

108

92

Suitable for M5 Screw

80

25

Caution : Open the cover only in 'OFF' position

32A-63ASuitable for M4 Screw

120

1"BSP (3Places)

130

44125

ON

160

216

Caution : Open the cover only in 'OFF' position

Switch mounted in Steel enclosure.

Round padlocking device (max. 3 padlocks) to prevent the Switchfrom being made to ON by unauthorised personnel.

� Enclosure colour : Dark grey base and light grey cover.

Degree of protection : IP53.

Knob version available on request.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

SB31S Upto 25A

Caution : Open the cover only in 'OFF' position

4470

120

80

Ø20-2 Holes

Ø6.5-2 Places

ON

147

110

Page 11: Ø64 LOAD BREAK - 3.imimg.com

METAL ENCLOSUREMOUNTING

9All dimensions in mm.

Switch mounted in Steel enclosure.

Round padlocking device (max. 3 padlocks) to prevent the Switchfrom being made to ON by unauthorised personnel.

Enclosure colour : Dark grey base and light grey cover.

Fourth pole can be added.

Degree of protection : IP53.

Knob version available on request.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

SB31M 32A - 63A

Caution : Open the cover only in 'OFF' position

100

180

Ø20-2 Holes

Ø6.5-2 Places

4485

ON

135

220

Switch mounted in Steel enclosure.

Round padlocking device (max. 3 padlocks) to prevent the Switchfrom being made to ON by unauthorised personnel.

Enclosure colour : Dark grey base and light grey cover.

Fourth pole can be added.

Degree of protection : IP53.

Knob version available on request.

RED / YELLOW-handle colour for MAIN / EMERGENCY Switches.

SB31L 80A-125A

Caution : Open the cover only in 'OFF' position

20027

2

Ø20-3 Holes

Ø8-4 Places

50125 245

315

Notes:

Page 12: Ø64 LOAD BREAK - 3.imimg.com

18

28

39

72

58

42

84 22

44.3

All dimensions in mm.

ACCESSORIES

10

ADD ON MAIN POLE(16A-63A)

ForSwitchCode

Code for Front

MountingSwitch

Code for Rear

MountingSwitch

LB116

LB120

ForSwitchCode

Code for Front

MountingSwitch

Code for Rear

MountingSwitch

LB225

LB232

LB240

LB263

33

24.5

57

17.2

5

16

Equivalent switch electrical rating.

Used as 4th/5th pole on eitherside of the switch.

ADD ON MAIN POLE(80A-125A)

FMC20 RMC20 FMC32 RMC32

FMC63 RMC63

For SwitchCode

Code for RearMounting Switch

LB4080 RMC80

LB4100

LB4125RMC125

Equivalent switch electricalrating

Used as 4th/5th pole on eitherside of the switch

18

28

39

72

ADD ON NEUTRAL POLE(16A-63A)

ForSwitchCode

Code for Front

MountingSwitch

Code for Rear

MountingSwitch

LB116

LB120

33

24.5

57

17.2

5

16

FNC20 RNC20

ForSwitchCode

Code for Front

MountingSwitch

Code for Rear

MountingSwitch

LB225

LB232FNC32 RNC32

LB240

LB263FNC63 RNC63

Early make late break contact.

Can be fitted on either side of the switch.

ApplicationsTo be used as Neutral Conductor to the switch.

ApplicationsFor switching action of additionalpole, when mounted with theswitch. The additional pole on

either side of the switch can be used to switch on any singlephase requirements simultaneously.

Page 13: Ø64 LOAD BREAK - 3.imimg.com

ACCESSORIES

11All dimensions in mm.

ADD ON AUXILIARY POLE

1 NO contact early break/latemake + 1 NC contact.

Can be fitted on either side ofthe Switch.

ApplicationsAuxiliary contact module has two contacts, 'NO and NC'. 'NO' contact is early break, late make contact. This is used to trigger

For SwitchCode

Code for Front

MountingSwitch

Code for Rear

MountingSwitch

LB116

LB120

LB225

LB232

LB240

LB263

LB4080 - RAC80

LB4100

LB4125

-

-

RATING

IEC / EN 16A, 500V220-240V 6AAC-15380-440V 4A

TERMINAL CROSS SECTIONmin. mm² 1.0

Single/Multiple strand wiremax. mm² 1.5

American Wire Gauge AWG 16

LB225-LB26326

60

41

18

LB116-LB12019

17.2

524.5

57

34

LB4080-LB4125

21

44.5

72

46.5

RAC125

FAC20 RAC20

FAC32 RAC32

FAC63 RAC63

58

42

84 22

44.3

�Early make late break contact.

Can be fitted on either side of the switch.

ApplicationsTo be used as Neutral Conductor to the switch.

ADD ON NEUTRAL POLE(80A-125A)

For SwitchCode

Code for RearMounting Switch

LB4080 RNC80

LB4100

LB4125 RNC125

Page 14: Ø64 LOAD BREAK - 3.imimg.com

12All dimensions in mm.

ACCESSORIES

LB SWITCHES: KNOB/HANDLE AND MOUNTING OPTIONS

The knobs/handles highlighted in red are standard, others indicates possible options.

MOUNTING LB116 LB120 LB225 LB232 LB240 LB263 LB4080 LB4100 LB41251 1B03 , TD , TD - - - - - - -

1 1 1 1B19 , FL , TD , FL , TD - - - - - - -

B40 - - - - - - -

, , , ,B13 - - - - -PG, BG PG, BG PG, BG PG, BG

B30 - - TD, , FL , FL , FL - - -

B33 - - - - -

B63 - - TD, TD, TD, TD, - - -

B23 - - TD, TD, TD, TD,

SH, , CG SH, , CG SH, , CG SH, , CG SH, , CG SH, , CG SH, , CG MB34LH, RH LH, RH LH, RH LH, RH LH, RH LH, RH LH, RH

MB42 , PG, , PG, , PG, , PG, , PG, , PG, , PG,

AB31S,SB31S - - -

B31SM - - -

B31M,AB31M,SB31M - - - - -

RD, , RD, , RD, ,B31L - - - - - -BG, RH BG, RH BG, RH

1FL

FP FP

FP FP

FL FL FL FL

FL TD TD TD

RD RD RD RD

FL FL FL FL

FL FL FL FL FL FL FL

RD RD RD RD RD RD RDFP FP

1 1FL FL BG BG BG BG BG BG BG

RD RD RD RD RD RD

FP FP RD RD RD RD

RD RD RD RD

LH LH LH

1FL

LB SWITCHES: KNOB/HANDLE, ENCLOSURE MOUNTING OPTIONS

The knobs/handles highlighted in red are standard, others indicates possible options.

ENCLOSURE B31SM B31M SB31S SB31M SB31L AB31S AB31MMOUNTING

, BG, , LH , BG , FL , LHPG, LH BG, PG PG, RD BG, PG BG, PG

B31L

RD RD LH RD RDRD, FP RD RD, LH

A B C D1FL 27 39 24 24

FL 36 50 27 25

A B C D1

TD 27 41 25 21TD 36 52 31 25

CODE TYPE

Tear DropTDKnob

FL Flag Knob

Flag KnobFPPadlockable

Pistol GripPGHandle

Ball GripBGHandle

KNOBS & HANDLES

CODE TYPE

Round Knob,RD Padlockable

Roll Handle,RH Padlockable

Short Handle,SH

Padlockable

LeechLH Handle,

Padlockable

CG CGL Handle,Padlockable

Knob/Handle

REAR MOUNTING

5All dimensions in mm.

B23

25A-63An

n

n

mounting on DIN EN50022 rail (35mm) and operable from thefront (door) - coupled with doormechanism.

Door interlock (Door openable onlyin 0FF position.)

Degree of protection :Front IP55.

2 hole rear mounting or snap

MB42 16A-20A

TO SUIT M4 SCREW

35

36

64

72 57

47

204 3mmPANEL GAP

SQ48

16

MOUNTING RAIL

80A-125A

25A-63A

n

n

2 hole rear mounting. Alternately snap mounting on

DIN EN50022 rail (35mm).

n Front IP30.

Degree of protection :

MOUNTINGRAIL FOURTH POLE

35 65

1572

62.5 2452.5

50 18

46

SUITABLE FORM4 SCREW

94 104

84

35

25

ALARRANGEMENTTERNATE FIXING

LOCK SCREW

M5 SCREWTO SUIT

SQ.64PANEL GAP5(MAX.)

SQ.488

PANEL DOOR

Ø4.5Ø12

338

37.5

I

O

MOUNTINGRAIL

80A-125A

104

84

SQ.48

102 73

36

9435

25

ALARRANGEMENTTERNATE FIXING

M5 SCREWTO SUIT

MOUNTINGRAIL

CMYK

64

18 50(L) 18

7235 65

355

85

3(Max)37.5

Ø48

Ø4.5 Ø12

ONOFF

ALTERNATIVE FIXINGARRANGEMENT

MOUNTINGRAIL M4 SCREW

TO SUIT

LOCK SCREW

PANEL GAP

PANEL DOOR

67 87

36

40

102

71

39

36

24

24

24

27

39

24

27

21

25

41

27

60 51

SQ

.88

Q66

65

45

125

Q66

51

39

17 SQ.64

36

Embedded EPS
There is embedded EPS on this page. Adobe Acrobat does not support the display of this type of object but it will print intact to a PostScript device.
Page 15: Ø64 LOAD BREAK - 3.imimg.com

13All dimensions in mm.

25A-63A, Front Mounting

� 4 hole front panel mounting. �

Front IP55.Degree of protection :

CHANGEOVERSWITCHES

25A - 125A, 3 and 4 Pole, AC 23 duty.

Available with and without SSenclosure.

Features�

Different mounting options.

Excellent switching performance.

High short circuit capacity.

Door interlock and padlockavailable.

Provides adequate space for cabletermination and very convenient forinstallation termination.

SWITCHING PROGRAMMES

CODE : 31153 3 POLE CHANGEOVER

I X X X

OII X X X

O

I II

R Y B R Y B

CODE : 31154 4 POLE CHANGEOVER

I X X X X

O

II X X X X

O

I II

R Y B N R Y B N

B21 25A-63A, Rear Mounting

� 4 hole rear mounting. �

Front IP55.Degree of protection :

B13

80A-125A, Rear Mounting

77

72 I II

O

65

ARRANGEMENT

ALTERNATIVE FIXING

MOUNTINGRAIL

35

50.5

TO SUIT M4 SCREW

Ø64

PANEL DOOR

Ø48

Ø4.5 Ø12

145

35

RAILMOUNTING

94

25

M5 SCREWTO SUIT

ALTERNATE FIXINGARRANGEMENT

146

25

72.5

84104

I

O

II

Page 16: Ø64 LOAD BREAK - 3.imimg.com

14All dimensions in mm.

CHANGEOVERSWITCHES

MB42

80A-125A, Rear Mounting

25A-63A, Rear Mounting

2 hole rear mounting or snap mounting on DIN EN50022 rail (35mm) and operable from the front (door) coupled with door mechanism.

Door interlock (door operable only in OFF position)

Degree of protection : Front IP65.

Rigid metal shaft/Switch assembly.

Switch with round padlocking device to prevent the Switch from being made ON by unauthorised persons.

Max. 3 padlocks.

Adjustable mounting by cutting the metal shaft to appropriate length to suit panel height.

Specific length of shaft can be offered on request.

MB34 25A-63A, Rear Mounting

80A-125A, Rear Mounting

ALTERNATIVE FIXING ARRANGEMENT

MOUNTINGRAIL

TO SUITM4 SCREW

LOCK SCREW 3(Max)PANEL GAP

PANEL DOOR

ø64 ø4.5 ø12

SQ 46

183

50.5

35 65 72 1 2

0

97

TO SUITM4 SCREW

12.5

220

6.5

12.5

2580

LOCK SCREW

104

84

182 3

PANEL GAP

ø17 ø4.5PANEL DOOR

SQ

48

1 2

0

ALTERNATIVE FIXING ARRANGEMENT

MOUNTINGRAIL

TO SUITM4 SCREW

LOCK SCREW 3(Max)PANEL GAP

PANEL DOOR

35 65 72

50.5

97

183

ø64 ø4.5 ø12

SQ36

TO SUITM4 SCREW

6.5

125

220

80

84104

25 182

3PANELGAP

LOCK SCREW

145

ø17 ø4.5 PANELDOOR

SQ

36

Page 17: Ø64 LOAD BREAK - 3.imimg.com

25A - 125A, 4 Pole, AC 23 duty.

Range available : 3 PoleChangeover - 31153, 3 Pole +Neutral Pole Changeover - 31154

� Powder coated steel enclosurewith separate earthing or IP65, ABSenclosure having interlock to open the lead only in OFF position forsafety.

Features

B31L 25A-63A

�Switch mounted in grey ABS/Polycarbonate optional enclosure

with IP65 protection and interlockprovided to open the lid in OFFposition.

All dimensions in mm.

ENCLOSURECHANGEOVER SWITCHES

15

� Colour : Yellow front plate andRed ball grip handle

SB31XL 80A-125A

130

205

185

Ø25-6 Nos. (Both Side)

1

0

250

370

42

Earth

42

� Interlock provided to remove cover only in ‘OFF’ position forsafety.

Powder coated steel enclosure.

Separate earthing provided.

� Colour : Yellow front plate andRed ball grip handle / grey frontplate and Black ball grip handle.

25A-63A

Powder coated steel enclosure.

Interlock provided to remove cover only in ‘OFF’ position for safety.

Separate earthing provided.

Colour : Yellow front plate andRed ball grip handle / grey frontplate and Black ball grip handle.

SB31

ø25-4Nos.(BOTH SIDE)

33 33 130

168

190

280

258

ø6.5

1

0

Page 18: Ø64 LOAD BREAK - 3.imimg.com

16Product improvement is continuous process. Hence, data given in this catalogue is subject tochange without intimation. Please acertain Product Certification and Listing.

PRODUCT CODING

R NC 32

32A

Neutral Module

Rear Mounting

ACCESSORIES

MC-Main Module

NC-Neutral Module

AC-Auxiliary Module

F-Front Mounting

R-Rear Mounting

X XX

2 - A32 - 25A to 32A63 - 40A to 63A80 - 80A125 - 100A to 125A

0 16 to 20A

XXX

LOAD BREAK AND CHANGEOVER SWITCHES

EXAMPLE

LB Switches, 25A, 3P, 9 O'clock, 4 hole front mounting, yellow front plate, red tear drop knob LB 225 31309 B13 TD YR

LB Switches, 63A, 3P, 9 O'clock, 4 hole front mounting, with metal shaft, yellow front plate, red round knob LB 263 31309 MB34 RD YR

LB Switches 40A, 3P, 12 O'clock offin B31SM enclosure, grey front plate, black round knob LB 240 31300 B31SM RD GB

LB Changeover Switch, 63A,3P, metal enclosure with interlock, yellow front plate, red ball grip handle LB 263 31153 SB31 BG YR

LB 263 31309 MB34 RD YRYellow Front Plate/Red Knob64 x 64 Front PlateRound Knob with Padlock (R)Metal Shaft with Round Knob with Padlock and Interlock3Pole 9 O' Clock "OFF"63ALoad Break Switch

LB X X X X X X X X X X X X X X X X X X

Load Switch Programme Code Mounting Options Knob Options Colour Break Rating Switch

CHANGEOVER SWITCHES: KNOB/HANDLE AND MOUNTING OPTIONS

The knobs/handles highlighted in red are standard, others indicates possible options.

MOUNTING LB225 LB232 LB240 LB263 LB4080 LB4100 LB4125

B13 PG, PG, PG, PG, - - -

MB34

MB42 PG, PG, PG, PG, PG, PG, PG,

B21 , PG , PG , PG , PG PG, , PG , PG

SB31 , PG , PG , PG , PG - - -

SB31XL - - - - , PG , PG , PG

B31L RD, RD, RD, , PG RD, , PG - - -

BG BG BG BG

RD RD RD RD RD RD RD

BG BG BG BG BG BG BG

BG BG BG BG BG BG BG

BG BG BG BG

BG BG BG

BG BG BG BG

ENCLOSURECHANGEOVER SWITCHES

Page 19: Ø64 LOAD BREAK - 3.imimg.com

72.5

3(Max)PANEL GAP

72

Changeover Switch

Switch with Roll Handle and Short Handle, both Padlockable

Switch for Single Hole Mountingwith Padlockable Knob

RANGE�

Rated upto 75HP for motor control and upto 125 Ampsfor switching.Optional dia 22.5mm singlehole, panel, base, DIN rail or enclosure mounting.On Load Changeover Switches with mounting options.

FEATURES�

APPROVALS�

Padlock and door interlocking facility.Double break contacts, withADD-ON Blocks.IP 20, touch proof terminals.With shroud for protection.

Conform to IEC, VDE, UL and CSA standards.Carry CE, UL and CSAmarks as applicable.Factory ISO 9001 certified by KPMG, US.

GROUP

Salzer Electronics Limited, Unit-II Chinnamaddampalayam, Bilichi Post,Coimbatore 641019. INDIA Phone : +91-4254-272311/272181/272013Fax : +91-4254-272012Email : [email protected] Website : www.salzergroup.net