6390 Electrical Block Diagram

Embed Size (px)

Citation preview

  • Revision Date

    ProjectApp'd

    Stage

    Order Number

    Date

    of

    Initials

    Page

    Check 1

    D

    C

    A

    BCUSTOMER IS RESPONIBLE FOR INSTALLING ADEQUATE SAFETY DEVICES AND GUARDS FOR THE PROTECTION OF PERSONNEL AND MACHINERY.

    By: Notes:

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    14

    15

    16

    17

    18

    01

    02

    COMPONENTS THAT APPEAR IN A DASHED BOX ARECUSTOMER SUPPLIED COMPONENTS.

    Check 2

    00

    C1

    C2

    D3

    G3

    F1F2F3F4

    E1E2E3E4G4

    B1B2B3B4D4

    G1G2D1D2

    R

    CASE GROUND NOT INTERNALLY TIED

    D

    I

    V

    I

    D

    E

    R

    D

    I

    V

    I

    D

    E

    R

    D

    I

    V

    I

    D

    E

    R

    A

    A

    A

    B

    B

    B

    A

    A

    A

    B

    B

    B

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    2

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    3

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    4

    A+A-B+B-

    A+A-B+B-

    A+A-B+B-

    A+A-B+B-

    GND

    GND

    +24VDC

    24 VDC COM

    C3A1A2A3A4C4

    A

    B

    A

    B

    GND

    A+

    A-

    B+B-

    5VDC

    RG

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    1

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    5

    T

    R

    A

    N

    S

    I

    S

    T

    O

    R

    O

    U

    T

    P

    U

    T

    H1H2H3H4

    RCB7/16/2007

    Preliminary6390 Splitter Interface

    AMS Controls1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    2KLL

    1

    I/O +24 VDC

    I/O COM

    GND

    GND

    6390

    SPL3

    SWITCH SETTINGSENCODER 3 ENCODER 4 ENCODER 5

    2 , 3 , 4 / DIV 5 , 6 , 7 / DIV 8 , 9 , 10 / DIV0 0 0

    0 00 0

    0000

    0

    11

    1 1111

    1 11 1 1

    1234681224

    0 0 00 0

    0 00

    000

    0

    11

    1 1111

    1 11 1 1

    1248163264128

    0 0 00 0

    0 00

    000

    0

    11

    1 1111

    1 11 1 1

    248163264128

    1

    * IF SWITCH #1 IS OFF = ENCODER #2 IS ONE TO ONE OUTPUT* IF SWITCH #1 IS ON = ENCODER #2 IS AN INPUT

    ENCODER 1 INPUT

    NOT USED ENCODER 2 OUTPUTONE TO ONE

    ENCODER 3 OUTPUT

    ENCODER 4 OUTPUT

    ENCODER 5 OUTPUTCAN BE USED FOR 24 VDC / 50 Hz / 50 MA

    6390 PASSTHROUGH SPLITTER

  • Revision Date

    ProjectApp'd

    Stage

    Order Number

    Date

    of

    Initials

    Page

    Check 1

    D

    C

    A

    BCUSTOMER IS RESPONIBLE FOR INSTALLING ADEQUATE SAFETY DEVICES AND GUARDS FOR THE PROTECTION OF PERSONNEL AND MACHINERY.

    By: Notes:

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    14

    15

    16

    17

    18

    01

    02

    COMPONENTS THAT APPEAR IN A DASHED BOX ARECUSTOMER SUPPLIED COMPONENTS.

    Check 2

    00

    C1E1E2E3E4G4

    B1B2B3B4D4

    G1G2D1D2

    D

    I

    V

    I

    D

    E

    R

    D

    I

    V

    I

    D

    E

    R

    D

    I

    V

    I

    D

    E

    R

    A

    A

    A

    B

    B

    B

    A

    A

    A

    B

    B

    B

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    3

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    4

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    5

    T

    R

    A

    N

    S

    I

    S

    T

    O

    R

    O

    U

    T

    P

    U

    T

    A+A-B+B-

    A+A-B+B-

    A+A-B+B-

    GND

    GND

    C2

    H3H4

    D3G3

    C3A1A2A3A4

    H2F1F2F3F4H1

    C4

    R

    Y

    CASE GROUND NOT

    A

    B

    A

    B

    A

    B

    +24 VDC

    24 VDC COM

    INPUT +24

    INPUT COM

    GND

    GND

    A+

    A-

    B+B-

    5VDC

    A+

    A-

    B+B-

    5VDC

    RG

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    2

    I

    S

    O

    L

    A

    T

    E

    D

    E

    N

    C

    O

    D

    E

    R

    1

    I

    S

    O

    L

    A

    T

    E

    D

    I

    N

    P

    U

    T

    INTERNALLY TIED

    RCB7/17/2007

    Preliminary6390 Splitter Interface

    AMS Controls2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2

    2KLL

    2

    6390

    SPL4I/O +24 VDC

    I/O COM

    GND

    GND

    INPUT +24 VDC

    INPUT COM

    SWITCH SETTINGSENCODER 3 ENCODER 4 ENCODER 5

    2 , 3 , 4 / DIV 5 , 6 , 7 / DIV 8 , 9 , 10 / DIV0 0 0

    0 00 0

    0000

    0

    11

    1 1111

    1 11 1 1

    1234681224

    0 0 00 0

    0 00

    000

    0

    11

    1 1111

    1 11 1 1

    1248163264128

    0 0 00 0

    0 00

    000

    0

    11

    1 1111

    1 11 1 1

    248163264128

    1

    * IF SWITCH #1 IS OFF = ENCODER #2 IS ONE TO ONE OUTPUT

    * IF SWITCH #1 IS ON = ENCODER #2 IS AN INPUT NO POWER ON H3 AND H4 = ENCODER #1 (INPUT) SELECTEDPOWER APPLIED TO H3 AND H4 = ENCODER #2 (INPUT) SELECTED

    ENCODER 1 INPUT

    ENCODER 2 INPUT

    ENCODER 3 OUTPUT

    ENCODER 4 OUTPUT

    ENCODER 5 OUTPUTCAN BE USE FOR 24 VDC / 50 Hz / 50 MA

    6390 SWITCHED SPLITTER