© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013) Page 1 of 11 Dell EqualLogic PS Series Firmware Version 6.0.7 Note: Items that have the potential for significant impact on system availability or data integrity are identified with the [CRITICAL] flag. Issues Corrected in Version 6.0.7 PS Series Firmware version 6.0.7 includes all bug fixes that were incorporated into versions 6.0 or earlier. Hardware The SSH key for a member was not retained between controllers, and required user to remove the old key and re-add the new one every time a controller fai over occurred. The reset command failed because the driver was stuck in "Checking for SED Drives" state. If user detached and reattached the same NAS node, the attach successfully completed, but the following warning was generated in the event log: unknown event: 223,084,583. During an array restart, the following health status error was not cleared: TIME_OF_DAY_CLOCK_BATTERY_LOW_CONDITION. The following hardware events were changed from warnings to major events: FailedConnectToLocalIPMI FailedConnectToPeerIPMI CPUTooHot differentCpuModelOnNode differentNumberOfCpuCores differentCpuModel differentTotalMemory allInterfacesAreDown temperatureSensorStatusError failedToReachPowerSupplies powerSupplyStatusError failedToReachBps NoLinkInEthOnController

6.0.7_FixList

Embed Size (px)

Citation preview

Page 1: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 1 of 11

Dell EqualLogic PS Series Firmware Version 6.0.7

Note: Items that have the potential for significant impact on system availability or data integrity are identified with the [CRITICAL] flag.

Issues Corrected in Version 6.0.7 PS Series Firmware version 6.0.7 includes all bug fixes that were incorporated into versions 6.0 or earlier.

Hardware • The SSH key for a member was not retained between controllers, and required user to remove the

old key and re-add the new one every time a controller fai over occurred.

• The reset command failed because the driver was stuck in "Checking for SED Drives" state.

• If user detached and reattached the same NAS node, the attach successfully completed, but the following warning was generated in the event log: unknown event: 223,084,583.

• During an array restart, the following health status error was not cleared: TIME_OF_DAY_CLOCK_BATTERY_LOW_CONDITION.

• The following hardware events were changed from warnings to major events: – FailedConnectToLocalIPMI – FailedConnectToPeerIPMI – CPUTooHot – differentCpuModelOnNode – differentNumberOfCpuCores – differentCpuModel – differentTotalMemory – allInterfacesAreDown – temperatureSensorStatusError – failedToReachPowerSupplies – powerSupplyStatusError – failedToReachBps – NoLinkInEthOnController

Page 2: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 2 of 11

Networking • When ports needed for replication were blocked by a firewall, if a user attempted to configure a

NAS container for replication, the following error was generated in the event log: Could not get the necessary information from the remote host. When this error occurs, the event log now displays a more descriptive message. Note: You must be running PS Series Array firmware version 6.0.7 or later along with FS Series Appliances version 2.0.7630 to see these improved messages.

• The CLI erroneously allowed non-ASCII characters in the SMTP read-only community name.

Replication • After restarting some members of the group, SyncRep-enabled volumes became out of sync.

Volumes • On occasion, a restart of a member in a multimember group took longer to come up.

• In a group with PS6500/PS6510 arrays, volumes were not balanced across members appropriately.

• On some array members, disabling legacy crypto caused inconsistencies across group members which led to IPsec not functioning correctly.

• In very rare cases, pages were moved to a vacating member, resulting in the page being lost.

Issues Corrected in Version 6.0.6-H2 Dell™ EqualLogic® PS Series Firmware version 6.0.6-H2 includes all bug fixes that were incorporated into versions 6.0 or earlier.

[CRITICAL] In rare circumstances, an error handling routine was not properly executed. Currently, this issue has only been observed in VMware environments, where a VMFS datastore might experience heartbeat metadata corruption, impacting the ability to perform operations on virtual machines (VMs). However, a small risk exists that a similar issue could be observed in non-VMware environments as well, so Dell recommends that all customers upgrade to this release.

Issues Corrected in Version 6.0.6 PS Series Firmware version 6.0.6 includes all bug fixes that were incorporated into versions 6.0 or earlier.

Hardware • After removing the array that previously was the group lead, the group could no longer send

syslog messages. [Tracking #: 562098]

• Some PS41x0 and PS61x0 arrays incorrectly reported that the control module clock battery had a low charge by issuing the following error message: Time-of-day clock battery voltage is low. [Tracking #s: 301264, 297744, 311890, 332643, 328593, 410414, and 412124]

• While using EqualLogic PS-M4110 blade storage arrays, fans randomly may have revved up to a high RPM rate and then went back down to normal. The getfanreqinfo section of the CMC logs showed normal fan request percentages, but the airflow messages indicated one of the arrays requested 82 or 100 percent.

Page 3: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 3 of 11

Volumes • When running SyncRep and doing a switchover between SyncActive and SyncAlternate pools,

the system sometimes became unresponsive for an undetermined amount of time. This condition was linked to volume renames after a switchover and then a switchback. This issue also occurred with SyncRep pool switches with lower block size I/O.

• Several fixes and improvements have been made in relation to conditions that might have determined a volume to become unavailable due to SyncRep after enabling/disabling SyncRep on a collection, or after attempting switching to SyncAlternate pool. [Tracking #: 746454]

• One member of a multimember group was down to 1% free space, whereas the others had at least 15% available due to a stuck page move process.

• An internal algorithm was improved to achieve more evenly distribution of connections across the members in the same pool. [Tracking #: 687370]

• An array with a 3-member group, 24 (sync-rep) volumes, and approximately 1200 snapshots reported that the mclpool limit had been reached.

Issues Corrected in Version 6.0.5 PS Series Firmware version 6.0.5 includes all bug fixes that were incorporated into versions 6.0 or earlier.

Firmware Update Issues • During firmware upgrade to patched revisions of firmware (-Lx), the active controller may have

failed to load the specific patch, thus the update may have only been applied to the passive controller. [Tracking # 782219]

Hardware In certain conditions, a fan failure warning event may have been displayed at various intervals with the following message: Fan speed is outside operating limits. Condition may then have cleared itself seconds later.

• On PS41x0 / PS61x0 platforms, controller modules may have reported invalid sensors reading as sensor temperature below the operating limit. [Tracking #s: 420027 and 549161]

• An issue that may have determined a passive controller to reboot spontaneously has been corrected to resolve the temporary effect on array redundancy. [Tracking #: 749774]

• [CRITICAL] On very rare occasions, during controller bootup, new RAID labels may have been written to the drives, resulting in data loss. [Tracking #s: 719252 and 725264]

• In very rare circumstances, certain use of IP payload compression may have generated an inappropriate response at the targets which may have resulted in an unexpected controller failover. [Tracking #: 706460]

• In rare occasions when using OffloadDataTransfers (ODX) with Windows 2012 initiators, a specific WriteUsingToken command could have generated an inappropriate response at the target that may have resulted in a controller failover. (See T10 specifications regarding WriteUsingToken command.) [Tracking #: 762035]

• An improvement has been made when an array would be operating in high-altitude installations to eliminate a cosmetic power supply fan speed error message in such circumstances. [Tracking #: 687218]

Page 4: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 4 of 11

• Legacy platforms to include controller modules Type 2 and Type 5 may have experienced unnecessary copy-to-spare of valid drives, if user was using SanAssist or ran diagnostics. [Tracking #: 758190]

• CPU erratas have been reviewed for PS(M)41x0, PS61x0, PS65x0, and PS60x0 platforms to prevent a watchdog reset that would have triggered an unexpected controller failover.

• After a copy-to-spare process for a SMART tripped drive, a replacement drive may have been displayed as "history of failure" instead of becoming hot-spare. [Tracking #s: 796873 and 749774]

Replication • If SyncRep was in use but had been paused on a volume for a long time, it could have resulted in

either resource exhaustion on the controller or in an unexpected controller failover.

• When using snap replication, the behavior of the unmanaged flag for the temporary promotion, temporary promotion with failback and permanent promotion has been revised to fix issue when such flag was inadvertently not removed. [Tracking #s: 424189, 619340, and 292232]

Volumes • A condition has been corrected that may have triggered unnecessary redistribution of the iSCSI

sessions to the same array member when volume distribution had not changed. [Tracking #s: 634504, 667173, 673207, 742967, and 777614]

• In certain scenarios, user actions of disable/enable, pause/resume of SyncRep-enabled volumes may have resulted in volume transition to an invalid internal state, requiring support intervention to restore availability of the volume to the initiators.

• [CRITICAL] In very rare circumstances and after a failover in multiple RAID LUN arrays, an internal log may have been inadequately committed, affecting volume page consistency. [Tracking #s: 694268 and 261429]

Other Issues • APagedPool resource allocation method was revised to prevent resource exhaustion in certain

scenarios. [Tracking #s: 797010, 700072, and 796918]

• In very large Active Directory implementations with the EqualLogic FS7xx0 and one or more PS Series arrays, repeated user / group list enumeration requests may have caused CIFS authentication failures and disconnects. A CLI support option was introduced to turn on/off the enumeration. [Tracking #s: 793483 and 814123]

Issues Corrected in Version 6.0.4 PS Series Firmware version 6.0.4 includes all bug fixes that were incorporated into versions 6.0 or earlier.

Firmware Update Issues • During a firmware upgrade on a group using sync-rep which was out of sync, the restart caused

errors, but did not generate a warning message.

• Disk firmware updates from KD08 to KD0A started on controller types 1, 2, and 5 but failed. Code was modified to no longer run firmware updates on these controller types. [Tracking #: 533460]

Page 5: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 5 of 11

• Following a firmware upgrade to version 6.0.1, when user converted from RAID 10 to RAID 50, the following error was displayed: Warning health conditions currently exist. Correct these conditions before they affect array operation. More spare drives are expected. [Tracking #: 552574]

• Following a firmware upgrade, user was unable to restart the array (from the GUI nor the CLI) after installing the Japanese language pack. [Tracking #: PSE006855]

• [CRITICAL] During a firmware update, while moving members into the maintenance pool, a volume appeared to be deleted with no user action. [Tracking #s: 679493, 705682, 659222, 635094, 410289, 202488, and 630792]

Hardware • An issue occurred with Self-Encrypting Drives (SED) where the array incorrectly marked the

spare drive as failed and needing replacement. [Tracking #: 656506]

• When using Host Integration Tools 4.5, after upgrading to firmware version 6.0.x, a controller restarted. [Tracking #s: 714079, 679484, 705740, 732366, 760900, 760896, and 764987]

• On a PS6110 or PS4110 array, a vertical failover followed by a passive controller failure or reboot may have caused the entire array to go offline.

• [CRITICAL] While processing a preemptive drive removal request, RAID incorrectly attempted to process more than one drive failure request, and generated a failure event and possible outages. [Tracking #s: 606292, 650187, 689710, 689806, 724011, 695665, 720342, and 753459]

Networking • A PS6110/PS4110 array with Data Center Bridging (DCB) enabled, in a correctly configured

DCB network, could take up to three or four minutes to fail over as a result of a network switch failure.

• LDAP Active Directory user name and group name are now limited to 63 ASCII characters. Prior to this release, ad-user/ad-group entries were limited to 26 characters.

• When settings negotiated with a DCB switch that was incorrectly configured resulted in there being no Ethernet flow control, the error message returned was not clear. Improved the GUI DCB flow control warning message to provide better guidance on what switch changes are necessary.

Replication • Under certain conditions, a retry request involving the automatic balancing functionality and

replication resulted in an unexpected controller failover. [Tracking #: 738935]

• User was unable to rerun replication. For current volumes, the process stopped with a status of in-progress. For new volumes, the following error was displayed: Bad password or partner name specified. Check the spelling and case of the group name and password.

• If user paused syncrep for prolonged periods of time (more than 24 hours), even on a single volume, the array became unresponsive.

• Under certain conditions, after promoting and demoting replicas, the following was displayed: Replica set with the same name already exists on the partner. Remove it on the partner. However, the phantom replica set could not be deleted. [Tracking #: 60746]

• In certain conditions when using EqualLogic Storage Replication Adapter for VMware® Site Recovery Manager® (SRM), a re-protect operation failed due to an orphan MIB entry.

Page 6: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 6 of 11

• When promoting a replica of a promoted replica, the volume ID of the second promoted replica did not match the volume ID of the original volume. Instead it matched the actual volume ID of the first promoted replica.

• If user restarted MgmtExec on the source array while replication was in progress, a Kernel exception occurred.

User Interface • The default value displayed in the web interface and Remote Setup Wizard was RAID 50, which

is different than the Dell-recommended RAID 6 policy.

• The Add Pair operation was not permitted while a node was detached. The following message was displayed: NAS controller {0} is detached. You must attach the controller to perform this operation.

Volumes • Intermittently, volume was getting stuck in "out of sync" state on switching to syncAlternate pool

while one of the members of that pool was vacating.

• A snapshot of a volume with multihost access enabled displayed the following error if multiple hosts attempted to simultaneously access the snapshot: Initiator cannot access this target because an iSCSI session from another initiator already exists and multihost access is not enabled for this target. [Tracking #: 635738]

• If SyncRep was enabled on template volumes that had "in use" pages, when user clicked on the Failover to SyncAlternate link, volume went out of sync.

Other Issues • After enabling the EMhome functionality, the following INFO message was displayed in the

event log every two minutes: E-Mail Home notification has been enabled. [Tracking #: 32985]

• In arrays running versions 6.0.0 through 6.0.3 firmware, an unauthenticated user could have potentially traversed the directory and accessed a file that contains encrypted password information for the Dell EqualLogic storage array. No user data was exposed by this vulnerability. A copy of the encrypted passwords does not offer a useful path to attacking the system. Users could not modify or upload system files via this vulnerability. [Tracking #: 691433]

Issue Corrected in Version 6.0.2-H2 PS Series Firmware version 6.0.2-H2 includes all bug fixes that were incorporated into versions 6.0 or earlier.

• An issue occurred with Self-Encrypting Drives (SED) where the array incorrectly marked the spare drive as failed and needing replacement. [Tracking #: 656506]

• A PS6110/PS4110 array with Data Center Bridging (DCB) enabled, in a correctly configured DCB network, could take up to three or four minutes to fail over as a result of a network switch failure.

Page 7: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 7 of 11

Issue Corrected in Version 6.0.2 PS Series Firmware version 6.0.2 includes all bug fixes that were incorporated into versions 6.0 or earlier.

Firmware Update Issues • After updating all members in a group to version 6.0.1 (from version 6.0.0), the GUI did not

allow the language packs to be installed on the members; the update wizard displayed the following: Member is not compatible with selected language pack.

• The firmware update script did not check suitability of all language kits before copying them. This resulted in missing language kits after the upgrade.

Hardware • Non-hardware drive errors on SATA drives led to preemptive drive removal. This issue impacted

controller types 7, 8, and 10 only, which were shipped on PS4000E, PS6000E, PS6010E, PS6500E and PS6510 arrays. [Tracking #s: 383341, 380686, 358418, 391004, 344726, 374075]

• Under rare conditions on a PS-M4110 array, while the OS was booting or transitioning to active from passive, a NULL pointer in the status page address caused a controller to restart out of sequence.

• If an array with SED drives was not set up correctly, and a reboot was performed during the setup process, SED keysharing was disrupted with a failed health condition of sed_unresolved.

Replication • When synchronous replication was enabled, if user paused the synchronous replication for a long

time while continuing to write to the volume, the secondary controller may have restarted.

• When the following operation was performed, one or more volumes were changed to state “unavailable due to SyncRep”. Once this state was reached, the volumes were stuck and could not be deleted.

- User added and removed volumes to an existing SyncRep collection, then a SyncRep switch occurred.

- User then removed a volume from the SyncRep collection.

Other Issues • If a MAC address was not resolved, the packets were put in the ARP hold queue until a response

to the ARP request was generated.

• An attempt to create a share directory with space in the name failed with the following error: " Character "" is not allowed.

• Under rare circumstances, a drive mirror operation caused the array to become unresponsive.

• If you were in the Replication section of the graphical user interface (GUI) and selected an individual outbound replica container, the help button in the upper right corner of the screen did not contain the correct information.

• An intra-group connection failure on a PS-M4110 in a DCB network caused volumes to go offline and become inaccessible. After about 4 or 5 minutes, the connection resumed and volumes were online again.

Page 8: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 8 of 11

Issue Corrected in Version 6.0.1-L1 Version 6.0.1-L1 contains some key diagnostic command enhancements that will provide support technicians with additional data on the health of the drives in an array.

Issue Corrected in Version 6.0 PS Series Firmware version 6.0 includes all bug fixes that were incorporated into versions 5.2.5 or earlier.

Firmware Update Issues • The firmware update script did not trigger emhome e-mails according to the email home policy.

[Tracking #: 17940]

• Users did not always pause in-progress replications during the firmware update process. Failure to pause in-progress replications can lead to replications not being fully functional after the update. Code was modified to display a warning message, reminding users to pause all replications prior to a firmware update.

• Users inadvertently initiated a restart before a CEMI firmware update completed. A restart during a CEMI firmware update can corrupt the flash card code on both controllers. The following warning is now displayed informing users not to restart until the firmware update completes: A CEMI firmware update is in progress. The array cannot be rebooted or halted in this state. Wait for the firmware update to complete, then retry the operation. [Tracking #: 75210]

• Under rare circumstances, a PS6x10 array would not restart after a disk drive replacement. [Tracking #s: 193506, 225473, 141950, 146411, 154775]

• During a firmware upgrade, before users issued a restart command, I/O performance dropped significantly. [Tracking #: 23320]

• Following a firmware update, the secondary controller in a PS61xx array erroneously reported a power supply fan failure every few hours. [Tracking #: 356374]

Group Security • The OpenSSH has been updated to “OpenSSH_5.0 NetBSD_Secure_Shell-20080403+, OpenSSL

0.9.9-dev 09 May 2008, sha2 fix (NetBSD-SA2009-012) applied” in order to correct security vulnerability issues. [Tracking #: 79575]

Initiator Connections • Disrupted iSCSI connections may not have been recovered immediately in groups with large

numbers of iSCSI initiator connections attempting to connect simultaneously.

• Even though a dedicated management network port was defined, NTP traffic traveled over Ethernet ports used for iSCSI traffic. [Tracking #: 122433]

• Users were seeing excessive warnings for connection limits. [Tracking #: 121385]

• Replication performance was degraded when using high-latency WAN links. [Tracking #: 334970]

• In SAN environments using the Host Integration Tools, iSCSI connections to the group were dropped when an internal process unexpectedly restarted. [Tracking #s: 301700, 315785, 400833]

Page 9: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 9 of 11

User Interface • The CLI command account show active was corrected to display remote and local IP

addresses.

• The GUI's Ethernet interface error status was not cleared until the member was rebooted. [Tracking #s: 107065, 97610, 97465, 96996, 94501, 75048, 93895, 93517, 93135, 88161]

• Users with read-only accounts could not change their own passwords. [Tracking #: 134062]

• If a pool movement failed, the GUI continued to report the movement's status as "in-progress."

• User was able to delete a member of a group that was offline, which caused a loss of data. The process to delete an offline member of a group has been changed to require interaction with the Dell® EqualLogic™ customer support team in an effort to prevent data loss. [Tracking #: 151373]

• In rare instances, after a firmware upgrade, grpadmin could not manage pools using the CLI. The following error was returned: Administrator grpadmin is not allowed access to pool defaults. [Tracking #: 155201]

• In rare instances, a resource used by the network management process could be exhausted, causing slow GUI response. [Tracking #s: 155970, 326406, 121237, 172614, 154843]

• The Group Manager GUI allowed the "Thin Provisioned Volume" option to be set when cloning a volume that was not thin provisioned. The resulting clone was not thin provisioned, but was listed as such in the GUI. This option is no longer available. You must first clone, and then thin provision a volume. [Tracking #s: 359992, 316424, 318855, 23490, 153934, 176714, 218976]

• Using the GUI to perform a pool move and a change from normal to thin-provisioned volume at the same time resulted in the volume having 0% volume reserve, and 0% for snap reserve. [Tracking #s: 176955, 298161, 191887]

• The Group Manager GUI could not display information about a storage pool, and indefinitely displayed a Retrieving data status message when merging pools or deleting them from the group.

• In rare instances, the Group Manager GUI displayed snapshots associated with previous replication operations that had been interrupted. [Tracking #s: 195934, 139176]

• The Group Manger GUI erroneously displayed the following error message while running diagnostics from the GUI while a CLI session was left open: Unknown error 13 returned by the server. [Tracking #s: 177329, 215508, 311220]

• User could not log in to the Group Manager GUI. [Tracking #: 187466]

• The Group Manager GUI and CLI incorrectly indicated that the construction of a RAID set remained at 0%, even after the operation had completed. [Tracking #: 332409]

Hardware • Under rare conditions, a read error on a disk caused it to go offline. [Tracking #s: 290764,

301337, 433799, 263746]

• Under rare conditions, the array panicked during a power cycle. When this occurred, the following message was displayed: Panic recovery from CPU0 with reason 'added invalid SAS address. [Tracking #: 336304]

• The PS65xx arrays did not always reset the amber drive warning light after a bad disk drive was replaced. [Tracking #s: 271703, 270105, 271189, 267520, 290665, 300213, 307085, 323951]

Page 10: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 10 of 11

• Under certain conditions, a PS65x0 channel card failure did not fail over to the secondary channel card. [Tracking #: 405829]

• After a hardware fault, the PS6100 primary active controller sometimes hung and did not fail over. [Tracking #s: 429293, 391583, 411766, 483775]

Replication • If replication was paused and the size was changed on the primary group, a restart of the

replication failed after a failback of the original volume from secondary to primary group. [Tracking #: 233412]

• Volume description did not replicate with volume name. [Tracking #: 840561086]

• If a VMware SRM volume was replicated and promoted, user could not connect to the replica.

Volumes • If a volume move operation failed due to a source pool space problem, it did not resume even

when the free space issue was resolved. [Tracking #: 32356]

• User could not cancel a volume move operation that was in-progress but not working correctly. [Tracking #: 327549]

• Space balancing when free space was low was not always effective. I/O errors and/or volume disconnects occurred when the pool approached 0 free space. [Tracking #: 150830, 162772, 150830, 179068, 200269, 202159, 150830, 228707, 241119]

• Volume replication became stuck “in-progress” while trying to replicate a volume containing lost blocks. [Tracking #: 401773]

• If a reset command was invoked for an array, users were not provided with a warning of what data was to be destroyed (the array name, the IP addresses, and any volumes on its member). Note that Dell strongly recommends that users not reset a running array. Use the delete member command instead, which moves data from the array to other arrays and automatically resets the array. [Tracking #: 249528]

• Using CLI, users could create a volume using 0% thin-growth-max, which is below the allowed minimum of 10%. [Tracking #: 268307]

• When the array attempted to automatically balance a 30MB volume across two members, it failed. Volumes larger than 30MB were not affected. [Tracking #: 294635]

• In rare circumstances, volumes went offline during a member update. When this occurred, notifications were generated, but not sent to the user. [Tracking #: 356009]

• In rare circumstances, during inter-array network problems with multiple volume moves, the GUI became unresponsive and volume moves could not continue. [Tracking #: 375991]

• Under certain instances, volumes marked with lost blocks, but still online, did not allow new iSCSI initiator logins after the lost blocks were cleared. [Tracking #: 378045]

• Free space balancing sometimes did not occur after a firmware update. [Tracking #: 338059]

• During firmware upgrade procedures, while migrating members into a maintenance pool, acknowledgments on cancelling tasks were not requested from participating members. This resulted in overlapping page movement tasks and ultimately in unexpected controller failovers. [Tracking #: 416721]

Page 11: 6.0.7_FixList

© Copyright 2012-2013 PS Series Firmware: FixList Version 6.0.7 (October 2013)

Page 11 of 11

Other Issues • Under a rare condition, such as an extremely heavy workload on the group, or an extremely poor

network environment, the iSCSI connection count could get out of sync. [Tracking #: 80616]

• The UNIX® Secure Copy (SCP) command failed to transfer large segments of diagnostics. [Tracking #: 86317]

• Free space and provisioning warning messages were reported too often during normal array operations. [Tracking #s: 160843, 78575, 295963, 348799]

• When applying a config.cli (from the CLI save-config command) to a fresh configuration, the following error was generated: Error: Bad command.

• When a volume was thin provisioned, then immediately moved to another pool, the volume’s snapshot reserve showed 0%. [Tracking #: 176955]

• A single-member group became unresponsive when communications with a RADIUS server were disrupted. [Tracking #: 211274]

• The crypto-legacy-protocols were being saved incorrectly with save-config.

• A network resource issue occurred during times of severe ARP flooding. [Tracking #: 191806]

• When a dedicated management port was enabled, bringing down eth0 caused sessions to disconnect on the management network. [Tracking #: 347770]

• In certain situations, volumes which had lost blocks cleared in the past were taken offline and incorrectly marked as having lost blocks. [Tracking #s: 348142, 217145, 373054, 442742]

• A timing issue caused RADIUS authentication to fail when there was a large number of volumes on the SAN. [Tracking #: 343065]

• The Remote Setup Wizard displayed incorrect serial number for PS4100 and PS6100 arrays.