Upload
buitruc
View
216
Download
0
Embed Size (px)
Citation preview
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
AN
SI D
8
64
mm
x 5
59
mm
Printed on ___% Post-Consumer
Recycled Content Paper
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\G
\6
05
08
94
4-S
HT
-G
-0
00
0.D
WG
CIT
Y O
F P
OR
TA
GE
L
A P
RA
IR
IE
IS
SU
ED
F
OR
T
EN
DE
R
2010 C
urrie B
ou
levard
B
ran
do
n, M
an
ito
ba
605
08
94
4
PH
AS
E 1
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
U
PG
RA
DE
S
Th
e M
an
ito
ba
W
ate
r S
erv
ic
es
B
oa
rd
__
__
__
__
__
__
__
_
DRAWING INDEX
GENERAL
00-G000 GENERAL GENERAL COVER SHEET & DRAWING INDEX
00-G001 GENERAL CIVIL OVERALL SITE PLAN
DIAGRAMS & SCHEMATICS
00-N001 DIAGRAMS & SCHEMATICS INSTRUMENTATION LEGEND & ABBREVIATIONS
00-N002 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL LEGEND & ABBREVIATIONS
00-N100 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL EXISTING PRE-TREATMENT P&ID
00-N101 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL ACTIFLO JET FLASH MIXING UPGRADE P&ID
00-N200 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL EXISTING CLARIFIER P&ID
00-N201 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL OZONE CONTACTOR UPGRADES P&ID
00-N300 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL EXISTING LIME FEED SYSTEM P&ID
00-N301 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL LIME CONVEYANCE SYSTEM UPGRADES P&ID
00-N400 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL EXISTING FLUORIDE & PHOSPHORIC ACID P&ID
00-N500 DIAGRAMS & SCHEMATICS PROCESS MECHANICAL EXISTING McKAY RESERVOIR P&ID
PROCESS
02-D101 PRE-TREATMENT BUILDING PROCESS MECHANICAL ACTIFLO JET FLASH MIXING PIPING LAYOUT
02-D301 PRE-TREATMENT BUILDING PROCESS MECHANICAL ACTIFLO JET FLASH MIXING SECTIONS & DETAILS
03-D101 MAIN BUILDING PROCESS MECHANICAL FLOW MANAGEMENT PLANS & DETAILS
03-D102 MAIN BUILDING PROCESS MECHANICAL OZONE QUENCHING PLAN
03-D103 MAIN BUILDING PROCESS MECHANICAL CHLORINATION BASEMENT PLAN
03-D104 MAIN BUILDING PROCESS MECHANICAL GAC BUILDING PLANS & SECTIONS
03-D301 MAIN BUILDING PROCESS MECHANICAL OZONE QUENCHING SECTIONS & DETAILS
MECHANICAL
03-H001 MAIN BUILDING MECHANICAL LEGENDS, DESIGN NOTES AND CONTROL SEQUENCES
03-H101 MAIN BUILDING MECHANICAL MAIN FLOOR FILTERS EXHAUST MODIFCATIONS
03-H102 MAIN BUILDING MECHANICAL CHEMICAL ROOM EXHAUST MODIFICATIONS
03-H103 MAIN BUILDING MECHANICAL SECOND FLOOR FILTERS EXHAUST MODIFICATIONS
03-H401 MAIN BUILDING MECHANICAL DETAILS
ELECTRICAL
02-E101 PRE-TREATMENT BUILDING ELECTRICAL PRE-TREATMENT PLAN
03-E101 MAIN BUILDING ELECTRICAL MAIN FLOOR PLAN
05-E101 MCKAY RESERVOIR ELECTRICAL MAIN FLOOR PLAN
05-E201 MCKAY RESERVOIR ELECTRICAL EXISTING MCC ELEVATION & SINGLE LINE DIAGRAM
The Manitoba Water
Services Board
00 - G 000
PROCESS AREA
00 GENERAL & SITEWORKS
02 PRETREATMENT BUILDING
03 MAIN BUILDING
04 RESERVOIR AND PUMP HOUSE
05 McKAY RESERVOIR
DISCIPLINE
G GENERAL
N PROCESS & INSTRUMENTATION DIAGRAMS
D PROCESS MECHANICAL
H PLUMBING & HVAC
E ELECTRICAL
DRAWING NUMBER
SEQUENTIAL DRAWING NUMBER
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
GENERAL
CIVIL
OVERALL SITE PLAN
SHEET NUMBER
00-G001
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\G
\6
05
08
94
4-S
HT
-G
-0
00
1.D
WG
N
PRE-TREATMENT BUILDING - PROCESS AREA 02
ACTIFLO JET FLASHING MIXING
MAIN BUILDING - PROCESS AREA 03
FLOW MANAGEMENT AFTER PRE-TREATMENT
OZONE ROOM LEAK DETECTION & SPACE VENTILATION
OZONE MONITORING EQUIPMENT
OZONE QUENCHING SYSTEM CALCIUM THIOSULPHATE
CHLORINATION MODIFICATIONS
LIME BATCH ALTERATIONS
LIME CONVEYANCE SYSTEM UPGRADES
VENTILATION UPGRADES
SUMMARY OF UPGRADES
McKAY RESERVOIR - PROCESS AREA 05
McKAY RESERVOIR VFD UPGRADES
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
RESERVOIR AND
PUMP HOUSE
PROCESS AREA 04
GRANULAR MEDIA
FILTER BUILDING
PORTAGE LA PRAIRIE
WATER TREATMENT PLANT
MAIN BUILDING
PROCESS AREA 03
PRE-TREATMENT
BUILDING
PROCESS AREA 02
FILTER BACKWASH
WASTE STORAGE
WELL
QUICKLIME SILO
SLUDGE LIFT STATION
ME
TE
R
CH
AM
BE
R
MAINTENANCE
SHED
PR
OP
ER
TY
N
OT
OW
NE
D B
Y C
IT
Y
ENLARGED SITE PLAN
NTS
CITY OF PORTAGE LA PRAIRIE
NTS
N
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
WATER TREATMENT
PLANT PROCESS
AREAS 02 AND 03
McKAY RESERVOIR
PROCESS AREA 05
D
C
I
FIELD DEVICE NAMING CONVENTION
POSITION: N - 9 9 9 - A B C D - 1 2 3 4 - X
PLANT CODE
(OPTIONAL)
PROCESS AREA INSTRUMENT IDENTIFICATION CODE
- UP TO FOUR CHARACTERS
- REFER TO TABLE 1
LOOP OR DEVICE NUMBER
ALPHA SUFFIX
NOTE: HYPHENS ARE OPTIONAL
FIELD DEVICE IDENTIFICATION
INSTRUMENT IDENTIFICATION CODE
- UP TO FOUR CHARACTERS
- REFER TO TABLE 1
OPERATING FUNCTION
- OPTIONAL
- REFER TO TABLE 2
PROCESS AREA
LOOP OR DEVICE NUMBER
POINT TAG NAMING CONVENTION
POINT NAMING CONVENTION
POSITION: N - 9 9 9 - A B C D - 1 2 3 4 - X
PLANT CODE
(OPTIONAL)
PROCESS AREA FUNCTIONAL IDENTIFICATION CODE
OR INTERNAL FUNCTIONAL CODE
- UP TO FOUR CHARACTERS
- REFER TO TABLE 1
LOOP OR DEVICE NUMBER
ALPHA SUFFIX
NOTE: HYPHENS ARE OPTIONAL
POINT IDENTIFICATION
I / O OR COMMUNICATION TYPEPROCESS AREA
LOOP OR DEVICE NUMBER
FUNCTIONAL DESCRIPTION
FUNCTIONAL IDENTIFICATION CODE
- UP TO FOUR CHARACTERS
- REFER TO TABLE 1
INSTRUMENT & FUNCTION SYMBOLS
NOTE: INSTRUMENTS & DEVICES NOT NORMALLY ACCESSIBLE TO THE OPERATOR
OR BEHIND-THE-PANEL DEVICES OR FUNCTIONS MAY BE DEPICTED BY USING
THE SAME SYMBOLS BUT WITH DASHED HORIZONTAL BARS, I.E. :
DISCRETE INSTRUMENTS
FIELD OR LOCALLY MOUNTED
NOT PANEL OR CABINET MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR
DISCRETE INSTRUMENTS
CENTRAL OR MAIN CONTROL ROOM
FRONT OF MAIN PANEL MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR
DISCRETE INSTRUMENTS
SECONDARY OR LOCAL CONTROL ROOM
FIELD OR LOCAL CONTROL PANEL MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR
ANNUNCIATOR POINT
FIELD OR LOCALLY MOUNTED
NOT PANEL OR CABINET MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR
ANNUNCIATOR POINT
FIELD OR LOCAL CONTROL PANEL
PANEL MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR
ANNUNCIATOR POINT
CENTRAL OR MAIN CONTROL ROOM
MAIN PANEL MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR
SHARED DISPLAY OR CONTROL
DEDICATED SINGLE FUNCTION DEVICE
FIELD OR LOCALLY MOUNTED
NORMALLY ACCESSIBLE TO THE OPERATOR AT DEVICE
SHARED DISPLAY OR CONTROL
SECONDARY OR LOCAL CONSOLE
FIELD OR LOCAL CONTROL PANEL
VISIBLE ON VIDEO DISPLAY
NORMALLY ACCESSIBLE TO AN OPERATOR AT CONSOLE
SHARED DISPLAY OR CONTROL
CENTRAL OR MAIN CONSOLE
VISIBLE ON VIDEO DISPLAY
NORMALLY ACCESSIBLE TO AN OPERATOR AT CONSOLE
PROGRAMMABLE LOGIC CONTROL
FIELD OR LOCALLY MOUNTED
NOT PANEL OR CABINET MOUNTED
NORMALLY ACCESSIBLE TO AN OPERATOR AT DEVICE
PROGRAMMABLE LOGIC CONTROL
SECONDARY OR LOCAL CONSOLE
FIELD OR LOCAL CONTROL PANEL
VISIBLE ON VIDEO DISPLAY
ACCESSIBLE TO AN OPERATOR AT CONSOLE
PROGRAMMABLE LOGIC CONTROL
CENTRAL OR MAIN CONSOLE
VISIBLE ON VIDEO DISPLAY
NORMALLY ACCESSIBLE TO AN OPERATOR AT CONSOLE
COMPUTER FUNCTIONS
FIELD OR LOCALLY MOUNTED
COMPUTER FUNCTIONS
SECONDARY OR LOCAL COMPUTER
VISIBLE ON VIDEO DISPLAY
NORMALLY ACCESSIBLE TO AN OPERATOR AT TERMINAL
COMPUTER FUNCTIONS
CENTRAL OR MAIN COMPUTER
VISIBLE ON VIDEO DISPLAY
NORMALLY ACCESSIBLE TO AN OPERATOR AT TERMINAL
DISCRETE INSTRUMENTS
SHARING COMMON HOUSING
COMMUNICATION INTERFACE
COMMUNICATES TO AN ADDRESSABLE DEVICE
(i.e. DB=DEVICEBUS, MB=MODBUS, E=ETHERNET
IY=CURRENT-FIELDBUS, FB=FIELDBUS, PB=PROFIBUS)
CDACS (COMPUTER DATA ACQUISITION & CONTROL SYSTEM)
INPUT, OUTPUT, OR FUNCTION
ACCESSIBLE
EG. DCS OR SCADA
STANDARD ABBREVIATIONS
TABLE 1 - INSTRUMENT IDENTIFICATION
ACK ACKNOWLEDGE (ALARM)
ALOH AUTO-LOCAL-OFF-HAND
A/M AUTO/MANUAL
CLS CLOSE
COB COMPUTER-OFF-BYPASS
COH COMPUTER-OFF-HAND
ESD EMERGENCY SHUTDOWN DEVICE
F/S FAST-SLOW SELECTION
FOR FORWARD-OFF-REVERSE
FWD FORWARD SELECTION
HA HAND-AUTO SELECTION
HOA HAND-OFF-AUTO SELECTION
L/L LEAD-LAG SELECTION
LOR LOCAL-OFF-REMOTE
LOS LOCK-OFF-STOP
L/R LOCAL-REMOTE SELECTION
M/A MANUAL-AUTO SELECTION
MAN MANUAL REG.
O/C OPEN/CLOSE
O/O ON-OFF SELECTION
OCA OPEN-CLOSE-AUTO SELECTION
OPN OPEN
OSC OPEN-STOP-CLOSE SELECTION
OVR INTERLOCK OVERRIDE SWITCH
P/M POSITIONER/MANUAL
P/R PANEL/REMOTE
POT POTENTIOMETER
R/B RUN/BYPASS
R/L RAISE-LOWER
REV REVERSE SELECTION
RST RESET
SEL SELECTOR SWITCH
S/S START-STOP
SP SET POINT
SWITCHING FUNCTIONS
TABLE 2 - OPERATING FUNCTIONS
CH4 METHANE
Cl2 CHLORINE
CO CARBON MONOXIDE
COMB COMBUSTIBLE GAS
DO DISSOLVED OXYGEN
HC HYDROCARBONS
H2S HYDROGEN SULFIDE
HUM HUMIDITY
LEL LOWER EXPLOSIVE LIMIT
MLSS MIXED LIQUOR SUSPENDED SOLIDS
NH4 AMMONIA GAS
NO NITRIC OXIDE
NO2 NITROGEN DIOXIDE NITRATE NO3
O2 OXYGEN
ORP OXIDATION REDUCTION POTENTIAL
OUR OXYGEN UPTAKE RATE
pH pH
PO4 PHOSPHORUS
SO2 SULPHUR DIOXIDE
SS SUSPENDED SOLIDS (DENSITY)
TSS TOTAL SUSPENDED SOLIDS
TURB TURBITY
VIB VIBRATION
ANALYTICAL FUNCTIONSINSTRUMENT OR DEVICE IDENTIFIERS
AE ANALYSIS ELEMENT
AIT ANALYSIS INDICATING TRANSMITTER
(ANALYTIC INST.)
AK ANALYSIS (SAMPLER) CONTROL STATION
ASH ANALYSIS SWITCH - HIGH
ASHH ANALYSIS SWITCH - HIGH-HIGH
AT ANALYSIS TRANSMITTER (ANALYTIC INST.)
DE DENSITY ELEMENT
DT DENSITY TRANSMITTER
EE VOLTAGE ELEMENT/TRANSFORMER
EI VOLTAGE INDICATOR
ET VOLTAGE TRANSMITTER
FE FLOW ELEMENT
FG FLOW METER ULTRASONIC GENERATOR
FI FLOW INDICATOR
FIC FLOW INDICATING CONTROLLER
FIT FLOW INDICATING TRANSMITTER
FQI FLOW TOTALIZING INDICATOR
FQY FLOW TOTALIZING / INTEGRATING RELAY
FSH FLOW SWITCH HIGH
FSL FLOW SWITCH LOW
FT FLOW TRANSMITTER
HK HAND CONTROL STATION
HS HAND SWITCH
IS CURRENT SWITCH
IE CURRENT ELEMENT/TRANSFORMER
II CURRENT INDICATOR
IY CURRENT RELAY
IT CURRENT TRANSMITTER
KY TIMER RELAY
LE LEVEL ELEMENT
LI LEVEL INDICATOR
LIC LEVEL INDICATING CONTROLLER
LIT LEVEL INDICATING TRANSMITTER
LSL LEVEL SWITCH LOW
LSH LEVEL SWITCH HIGH
LSLL LEVEL SWITCH LOW LOW
LSHH LEVEL SWITCH HIGH HIGH
NS MOISTURE SWITCH
PDI PRESSURE DIFFERENTIAL INDICATOR
PE PRESSURE ELEMENT
PG PRESSURE GAUGE
PI PRESSURE INDICATOR
PIT PRESSURE INDICATING TRANSMITTER
PS PRESSURE SWITCH
PSH PRESSURE SWITCH HIGH
PSHH PRESSURE SWITCH HIGH HIGH
PSL PRESSURE SWITCH LOW
PSLL PRESSURE SWITCH LOW LOW
PT PRESSURE TRANSMITTER
INSTRUMENT SIGNAL IDENTIFIERS
AAH ANALYSIS ALARM - HIGH DIGITAL INPUT
AAHH ANALYSIS ALARM - HIGH-HIGH DIGITAL INPUT
AI ANALYTICAL INDICATION ANALOG INPUT
AF ANALYSIS (SAMPLER) FAIL DIGITAL INPUT
AM ANALYSIS (SAMPLER) ON/OFF DIGITAL INPUT
AN ANALYSIS (SAMPLER) START DIGITAL OUTPUT
FAL FLOW ALARM LOW DIGITAL INPUT
FAH FLOW ALARM HIGH DIGITAL INPUT
FI FLOW INDICATION ANALOG INPUT
FF FLOW RATE FAIL DIGITAL INPUT
FQ FLOW TOTALIZER DIGITAL INPUT
LAH LEVEL ALARM HIGH DIGITAL INPUT
LAL LEVEL ALARM LOW DIGITAL INPUT
LC LEVEL CONTROL (SETPOINT) ANALOG OUTPUT
LDI LEVEL DIFFERENTIAL INDICATION DIGITAL INPUT
LF LEVEL FAIL DIGITAL INPUT
LI LEVEL INDICATION ANALOG INPUT
MF MOTOR FAILURE DIGITAL INPUT
MM MOTOR RUN STATUS DIGITAL INPUT
MMF MOTOR RUN STATUS FORWARD DIGITAL INPUT
MMR MOTOR RUN STATUS REVERSE DIGITAL INPUT
MN MOTOR START/STOP DIGITAL OUTPUT
MQ MOTOR RUN HOURS DIGITAL INPUT
MX MOTOR UNCLASSIFIED (X = RESET) DIGITAL INPUT
OAH TORQUE ALARM HIGH DIGITAL INPUT
PAH PRESSURE ALARM HIGH DIGITAL INPUT
PAL PRESSURE ALARM LOW DIGITAL INPUT
PI PRESSURE INDICATION ANALOG INPUT
QA COMMON ALARM (OR TROUBLE) DIGITAL INPUT
QF COMMON FAIL ALARM DIGITAL INPUT
GENERAL
AI ANALOG INPUT
AO ANALOG OUTPUT
CCTV CLOSED CIRCUIT TELEVISION
DB DEVICE BUS
DCS DISTRIBUTED CONTROL SYSTEM
DI DIGITAL INPUT
DO DIGITAL OUTPUT
D/P DIFFERENTIAL PRESSURE
FB FIELDBUS
HMI HUMAN MACHINE INTERFACE
I/I CURRENT TO CURRENT
I/O INPUT/OUTPUT
I/P CURRENT TO PRESSURE
IBD INBOARD BEARING
LEAK LEAKAGE
LCP LOCAL CONTROL PANEL
MCC MOTOR CONTROL CENTRE
OBD OUTBOARD BEARING
O/L OVERLOAD
PLC PROGRAMMABLE LOGIC CONTROLLER
RTD RESISTIVE TEMPERATURE DEVICE
SOL SOLENOID
T/C THERMOCOUPLE
TOR TORQUE
WDG WINDING
SAL MOTION ALARM LOW DIGITAL INPUT
SC SPEED CONTROL (SETPOINT) ANALOG OUTPUT
SI SPEED INDICATION ANALOG INPUT
TAH TEMPERATURE ALARM HIGH DIGITAL INPUT
TI TEMPERATURE INDICATION ANALOG INPUT
UA MULTIFUNCTION ALARM (GENERAL) DIGITAL INPUT
VB VALVE CLOSE (OR DECREASE) DIGITAL \ MODULATING OUTPUT
VD VALVE OPEN (OR INCREASE) DIGITAL \ MODULATING OUTPUT
WI WEIGHT INDICATION ANALOG INPUT
XA UNCLASSIFIED ALARM (X = FIRE) DIGITAL INPUT
XI UNCLASSIFIED INDICATION ANALOG INPUT
YK COMPUTER / LOCAL STATION DIGITAL INPUT
YM COMPUTER OPERATIONAL DIGITAL INPUT
YN/XS ESD ACTIVATED DIGITAL INPUT
YS COMPUTER STATUS (AUTO) DIGITAL INPUT
YX COMPUTER UNCLASSIFIED (STATUS ON) DIGITAL INPUT
ZB POSITION CLOSED (LIMIT SWITCH) DIGITAL INPUT
ZC POSITION CONTROL (SETPOINT) ANALOG OUTPUT
ZD POSITION OPEN (LIMIT SWITCH) DIGITAL INPUT
ZI POSITION INDICATION ANALOG INPUT
ZL POSITION LOW (BELT TENSION) DIGITAL INPUT
ZN POSITION OPEN/CLOSE COMMAND DIGITAL OUTPUT
ZSC CLOSED STATUS DIGITAL INPUT
ZSM MIDDLE STATUS DIGITAL INPUT
ZSO OPENED STATUS DIGITAL INPUT
SC SPEED CONTROLLER
SI SPEED INDICATOR
TC TEMPERATURE CONTROLLER
TE TEMPERATURE ELEMENT
TG TEMPERATURE GAUGE
TI TEMPERATURE INDICATOR
TIT TEMPERATURE INDICATING TRANSMITTER
TSH TEMPERATURE SWITCH HIGH
TSHH TEMPERATURE SWITCH HIGH HIGH
TSL TEMPERATURE SWITCH LOW
TSLL TEMPERATURE SWITCH LOW LOW
TT TEMPERATURE TRANSMITTER
VE VIBRATION ELEMENT
VT VIBRATION TRANSMITTER
WE WEIGHT ELEMENT
WIT WEIGHT INDICATING TRANSMITTER
ZI POSITION INDICATOR
ZS POSITION SWITCH
ZSC POSITION SWITCH CLOSED (LIMIT SWITCH)
ZSO POSITION SWITCH OPEN (LIMIT SWITCH)
ZIT POSITION INDICATING TRANSMITTER
ZT POSITION TRANSMITTER
INSTRUMENT FIELD DEVICE IDENTIFICATION
INSTRUMENT SUPPLY
OR PROCESS TAP
UNDEFINED SIGNAL
PNEUMATIC SIGNAL
ELECTRIC SIGNAL
HYDRAULIC SIGNAL
CAPILLARY TUBE
ELECTROMAGNETIC OR
SONIC SIGNAL (GUIDED)
ELECTROMAGNETIC OR
SONIC SIGNAL (NOT GUIDED)
INTERNAL SYSTEM LINK
(SOFTWARE OR DATA LINK)
MECHANICAL LINK
PNEUMATIC BINARY SIGNAL
ELECTRIC BINARY SIGNAL
FOUNDATION FIELDBUS
SIGNAL LINE TYPES
PROPOSED - EXISTING - DESCRIPTION
PRIMARY ELEMENT SYMBOLSMISCELLANEOUS SYMBOLS
ANNUBAR
CORIOLIS MASS
FLOW METER
DENSITY METER
DIAPHRAGM SEAL
FLOW ELEMENT
INTEGRAL WITH
TRANSMITTER
(MASS FLOW, ETC.)
IN-LINE CAPACITANCE
FLOW ELEMENT
ANNULAR PRESSURE
ISOLATOR
M MAGNETIC FLOW METER
PITOT TUBE
POSITIVE DISPLACEMENT
METER
PROPELLER OR
TURBINE METER
SONIC FLOW METER
(DOPPLER OR
TRANSIT TIME)
T
THERMAL MASS
FLOW ELEMENT
ROTAMETER
VORTEX
FLOW SENSOR
FLOAT LEVEL ELEMENT
DISPLACEMENT
LEVEL ELEMENT
BUBBLER LEVEL TUBE
UNGUIDED WAVE
ULTRASONIC / MICROWAVE
LEVEL ELEMENT
GUIDED WAVE
RADIO FREQUENCY
LEVEL ELEMENT
CAPACITANCE / POINT
LEVEL ELEMENT
VIBRATING
TUNING FORK
LEVEL SWITCH
THERMAL SENSING
RTD STRIP
THERMAL ELEMENT
WITH WELL
R
P
INTERLOCK
REFER TO CONTROL
DESCRIPTION STRATEGY
RESET FOR LATCH-TYPE
OPERATOR
PURGE CONNECTION
OR FLUSHING DEVICE
VFD VARIABLE FREQUENCY DRIVE
VSD VARIABLE SPEED DRIVE
ANNUNCIATOR HORN
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
FT
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
FI
ABCD
1234
N
ZZ
ABDC
1234
N
- - -
- - -
- - -
DI
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
XXXX
L L L L
X X X X
L L L L
X X X X
DIFFUSER
FLOW INDICATOR CALLOUT
#
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
INSTRUMENTATION
LEGEND & ABBREVIATIONS
SHEET NUMBER
00-N001
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
00
1.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
M
AIR DRYER AD
BLOWER BL
EXHAUST FAN EF
SYMBOL - TYPE - ABBREVIATION SYMBOL - TYPE - ABBREVIATION
CENTRIFUGE CFG
D
M
COMPRESSOR CP
NON-MOTORIZED EQUIPMENT
CYCLONE CY
SYMBOL - TYPE - ABBREVIATION SYMBOL - TYPE - ABBREVIATION
GRINDER GDR
GRIT CLASSIFIER GCL
MIXER (STATIC) SM
MIXER (PROPELLER) MXR
MOTOR -
SCREEN (MANUAL) SCR
S
HEAT EXCHANGER HEX
SAMPLER (AUTOMATIC) SMP
INJECTER INJ
AERATOR (SURFACE) AER
SCREEN (BAR) SCR
SCREEN (ROTARY) SCR
CONVEYOR (BELT) CON
SCREENINGS
WASHER / COMPACTOR CMP
SLUDGE SKIMMER SSK
DAF DRIVE DDR
PIPE LINE DEVICES
E
MAJOR PROCESS LINE
MINOR PROCESS LINE
INSULATED PIPE
(WITH HEAT TRACING)
FUTURE PROCESS LINE
EXISTING PIPING
& EQUIPMENT
VENDOR PACKAGE
SUPPLY BOUNDARY
EXISTING ITEMS
TO BE REMOVED
EQUIPMENT SYMBOLS
PUMPS
CENTRIFUGAL PUMP P
COLUMN PUMP P
DIAPHRAGM PUMP P
GEAR PUMP P
METERING PUMP P
PLUNGER PUMP P
PROGRESSING
CAVITY PUMP P
ROTARY LOBE PUMP P
SUBMERSIBLE PUMP P
SUBMERSIBLE
PROPELLER PUMP P
VERTICAL PUMP P
PROCESS LINE TYPES
PROPOSED STRUCTURE
FLAP GATE FLG
GATE SYMBOLS
LEVEL CONTROL GATE LCG
SLIDE GATE SG
SLUICE GATE SLG
STOP LOG SL
WEIR GATE WG
EXISTING STRUCTURE
DIAPHRAGM, PRESSURE
TRAP
ACTUATORS
DIAPHRAGM, SPRING
DIGITAL
MOTORIZED
PISTON
SOLENOID
S
AIR GAP
BLIND FLANGE OR
FLANGE CONNECTION
CALIBRATION CHAMBER
CAP OR PLUG
QUICK CONNECTOR
DIFFUSER OR
SPRAY NOZZLE
D
DRAIN
EXPANSION JOINT
EMERGENCY EYEWASH
& SHOWER STATION
REDUCER
SEPARATOR, AIR
SEPARATOR, LIQUID
SIGHT GLASS
SPECTACLE BLIND
STRAINER
STRAINER, BASKET
T
UTILITY CONNECTION
AIR INTAKE
VENT, AIR
VENT, STEAM
VENTURI
SILENCER
UNION
SYMBOL - TYPE - ABBREVIATION SYMBOL - TYPE - ABBREVIATION
CUT THROAT FLUME CFL
PALMER BOWLES FLUME PBF
PARSHALL FLUME PFL
STANDARD ABBREVIATIONS
EQUIPMENT ABBREVIATIONS
COMMODITY ABBREVIATIONS
CHEMICAL ABBREVIATIONS
K
VALVE SYMBOLS
SYMBOL - TYPE - ABBREVIATION
BALL VALVE (N.O.) BV
BALL VALVE (N.C.) BV
CHECK VALVE CV
BUTTERFLY VALVE BFV
PLUG VALVE (N.O.) PV
PLUG VALVE (N.C.) PV
GATE VALVE (N.O.) GV
GATE VALVE (N.C.) GV
BALL CHECK VALVE BCV
KNIFE GATE VALVE KV
NEEDLE VALVE NV
GLOBE VALVE GLV
BACKFLOW PREVENTER BFP
BALANCING DAMPER BD
DUCKBILL CHECK VALVE DCV
DOUBLE LEAF CHECK VALVE CV
PINCH VALVE PNV
TELESCOPIC VALVE TSV
PRESSURE REGULATOR
EXTERNAL PRESSURE TAP PRV
PRESSURE REGULATOR
SELF CONTAINED PRV
BACK PRESSURE REGULATOR
EXTERNAL PRESSURE TAP BPV
BACK PRESSURE REGULATOR
SELF CONTAINED BPV
PRESSURE RELIEF VALVE PRV
VACUUM RELIEF VALVE PRV
PRESSURE & VACUUM
RELIEF VALVE PRV
PRESSURE RELIEF VALVE
(RUPTURE DISC) RD
VACUUM RELIEF VALVE
(RUPTURE DISC) RD
THREE-WAY VALVE 3W
FOUR-WAY VALVE 4W
ANGLE VALVE AV
DIAPHRAGM VALVE DV
MUD VALVE MDV
FLOAT VALVE FV
SYMBOL - TYPE - ABBREVIATION
IRIS VALVE IV
THERMAL SHUT OFF VALVE TOV
EQUIPMENT & VALVE IDENTIFICATION
ANNOTATION SYMBOLS
GENERAL SYMBOLS
FLOW ARROWS
WATER LEVEL
INSTRUMENT SIGNAL IDENTIFICATION
SIGNAL IDENTIFICATION
PIPE IDENTIFICATION
COMMODITY
NOMINAL
DIAMETER
COMMODITY
CHANNEL OR
CHUTE SIZE
WIDTHxHEIGHT (mm)
CHANNEL / CHUTE IDENTIFICATION
EQUIPMENT
ABBREVIATION
EQUIPMENT NUMBER
PROCESS AREA
EQUIPMENT / VALVE
ABBREVIATION
EQUIPMENT NUMBER
PROCESS AREA
MOTORIZED EQUIPMENT
NON-MOTORIZED
EQUIPMENT / VALVES
PROCESS LINE IDENTIFICATION
COMMODITY
SOURCE OR
DESTINATION
REFERENCE
DRAWING
REFERENCE
NUMBER
COMMODITY
SOURCE OR
DESTINATION
REFERENCE
DRAWING
REFERENCE
NUMBER
COMMODITY
SOURCE OR
DESTINATION
REFERENCE
DRAWING
REFERENCE
NUMBER
FLOW: LEFT TO RIGHT
FLOW: BOTH DIRECTIONS
FLOW: RIGHT TO LEFT
SYMBOL - TYPE - ABBREVIATION
MOTORIZED EQUIPMENT
CONVEYOR (SCREW) CON
FLEXIBLE CONNECTION
HOSE REEL
ORIFICE PLATE
PRESSURE SENSOR (IN-LINE)
FILTER/ MESH SCREEN
PULSATION DAMPENER
PIPE MATERIAL
LINE NUMBER
S
SAMPLER (AUTOMATIC) SMP
FLAME ARRESTER
NN
99 - 999
NN - 99 - 999
A99-N-9999
COMMODITY
TO / FROM
A 99-N-9999
COMMODITY
TO / FROM
A 99-N-9999
COMMODITY
TO / FROM
999x999 - NNN
NNN
8888 - 999 - NNN - ZZZ
XX
LIMIT OF UPGRADE
BOUNDARY
ACU AIR CONDITIONING UNIT
AD AIR DRYER
BLR BOILER
BLW BLOWER
CDR CONDENSER
CDU CATALYTIC DESTRUCT UNIT
CE CENTRIFUGE
CFR CHEMICAL FEEDER
CHLR CHILLER
CMP COMPRESSOR
CON CONVEYOR
CP CONTROL PANEL
CRN CRANE OR HOIST
CTS CATHODIC TEST STATION
DEM DEMISTER
DES DESICCANT DRYER
DF DAF SKIMMER
DIF DIFFUSER
EF EXHAUST FAN
EL ELECTROLYTIC CELL
EPR EVAPORATOR
ETM ELAPSED TIME METER
ETNK EXPANSION TANK
F FAN
FC FLOCCULATION CHAMBER
FCV FLOW CONTROL VALVE
(MODULATING)
FLC FLOCCULATOR
FLT FILTER
FV FLOW CONTROL VALVE
(OPEN/CLOSE)
GF GAS FILTER
GP GLYCOL PUMP
GT GRAVITY THICKENER
HEX HEAT EXCHANGER
HPG HAND PULL GATE
HTR ELECTRIC HEATER
HV HAND VALVE
HWH HOT WATER HEATER
HWP HOT WATER PUMP
LCG LEVEL CONTROL GATE
LCP LOCAL CONTROL PANEL
LCV LEVEL CONTROL VALVE
(MODULATING)
LV LEVEL CONTROL VALVE
(OPEN/CLOSE)
M MOTOR
MCC MOTOR CONTROL CENTRE
MD MOTION DETECTOR
OP ORIFICE PLATE
PCT PARTICLE COUNTER
PCU POLYMER BULK BAG UNLOADER
PCV PRESSURE CONTROL VALVE
PFL PARSHALL FLUME
PFLT POWER FILTER
PLC PROGRAMMABLE LOGIC
CONTROLLER
PNL PANEL BOARD
PPU POLYMER PREPARATION UNIT
PSU POWER SUPPLY UNIT
SCRB SCRUBBER
SE SAMPLER ELEMENT
SF SUPPLY FAN
SLR SILENCER
SOL SOLENOID ACTUATOR
STA STATIC MIXER
SWP SWASH PLATE
T TANK
TB TURBIDITY METER
TCV TEMPERATURE CONTROL VALVE
TOTE TOTE TANK
TRP TRAP
TV TEMPERATURE /
VIBRATION MONITOR
UPS UNINTERRUPTIBLE
POWER SUPPLY
UVR ULTRA-VIOLET LIGHT REACTOR
V VALVE
VFD VARIABLE FREQUENCY DRIVE
VAP VAPORIZER
VSD VARIABLE SPEED DRIVE
W WEIR
WRT WASHWATER RECOVERY TANK
WSF WATER SOFTENER
BW BACKWASH WATER
BWW BACKWASH WASTE WATER
CA COMPRESSED AIR
CCS CLEAN IN PLACE SUPPLY
CCW CLEAN IN PLACE WASTE
CDR CONDENSER WATER RETURN
CDS CONDENSER WATER SUPPLY
CEN CENTRATE
CW CLARIFIED WATER
DMW DEMINERALIZED WATER
DRA DRAIN
DRW SATURATED RECYCLE WATER
DSW DISTILLED WATER
FAS FILTER AIR SCOUR
FLI FILTER INFLUENT
FLW FLOCCULATION BASIN
EFFLUENT
FT FILTRATE
FTR FILTER TO RECYCLE
FW FILTER TO WASTE
GCR GAC TRANSFER WATER
RECOVERY
GCW GAC TRANSFER WATER
HF HYDRAULIC FLUID
HCO HYDRAULIC OIL
IA INSTRUMENT AIR
IXE ION EXCHANGE EFFLUENT
OF OVERFLOW
OW OZONATED WATER
PAC ACTIVATED CARBON - SLURRY
PER REVERSE OSMOSIS
PERMEATE
PSW PLANT SERVICE WATER
PW PRETREATED WATER
RME RAPID MIX BASIN EFFLUENT
RW RAW WATER
SAM SAMPLE
SAN SANITARY DRAINAGE
SLU DAF FLOAT
SOW SOFTENED WATER
STE STEAM
SUB SUBNATANT
SUP SUPERNATANT
SW SEAL WATER
TW TREATED WATER
VNT VENT
AAG ANHYDROUS AMMONIA, GAS
AAL ANHYDROUS AMMONIA, LIQUID
AAS AMMONIUM HYDROXIDE SOLUTION
AAV AMMONIA GAS (VACUUM)
ACE ACETIC ACID
ACS ACTIVATED SILICA
ACTL ACETYLENE
ALS ALUM SOLUTION
ALU ALUM
ASH ASH
BRS BRINE SOLUTION
BRW BRINE WASTE
CAO LIME (QUICK LIME)
CAOH LIME (HYDRATED)
CDG CARBON DIOXIDE
CDL CARBON DIOXIDE LIQUID
CI SODIUM HEXAMETA PHOSPHATE
CLD CHLORINE DIOXIDE
CLG CHLORINE GAS (PRESSURE)
CLL CHLORINE LIQUID
CLS CHLORINE SOLUTION
CLV CHLORINE GAS (VACUUM)
CS CAUSTIC SODA
CSS DILUTE CAUSTIC SODA
CUS COPPER SULFATE
CTH CALCIUM THIOSULPHATE
FC FERRIC CHLORIDE
FCPL FERRIC CHLORIDE PICKLE LIQUOR
FEC FERROUS CHLORIDE
FES FERROUS SULPHATE
FS FERRIC SULFATE
FSS FERROUS SULFATE
GOX GASEOUS OXYGEN
HCL HYDROCHLORIC ACID
HEL HELIUM
HFS FLUOSILIC ACID
HG HYDROGEN GAS
HL HYDROGEN LIQUID
HP HYDROGEN PEROXIDE
LM LIME (DRY)
LMS LIME SLUDGE
LOX LIQUID OXYGEN
LS LIME SLAKER
MET METHANOL
N2 NITROGEN
NAOH SODIUM HYDROXIDE
NASF SODIUM SILICOFLUORIDE
NOX NITROUS OXIDE
OIA OZONE IN AIR
OIO OZONE IN OXYGEN
OW OZONATED WATER
PE POLYETHYLENE TUBING
PHA PHOSPHORIC ACID
PACL POLYALUMINUM CHLORIDE
PLY POLYMER
PP POTASSIUM PERMANGANATE
PPP PHOSPHATE
PYPH POLYPHOSPHATE
SA SULPHURIC ACID
SAS SODA ASH SOLUTION
SBC SODIUM BICARBONATE
SBS SODIUM BISULFITE
SC SODA ASH
SDG SULFUR DIOXIDE GAS (PRESSURE)
SDL SULFUR DIOXIDE LIQUID
SDS SULFUR DIOXIDE SOLUTION
SDV SULFUR DIOXIDE GAS (VACUUM)
SH SODIUM HYPOCHLORITE
SHS SODIUM HYPOCHLORITE SOLUTION
SLT SODIUM CHLORIDE
SS SODIUM SILICATE
VAC VACUUM
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
LEGEND & ABBREVIATIONS
SHEET NUMBER
00-N002
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
00
2.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
SEE 00-N101
C
E
D
F
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
EXISTING PRE-TREATMENT P&ID
(EXISTING PID102/2)
SHEET NUMBER
00-N100
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
10
0.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
C 00-N100
RAW WATER
FROM EXISTING RAW
WATER WETWELL
MMM
M
VFD
PT
W-3
52
2P
TW
-3
52
3
D
DV-3515
D
M
PTW-3517
M
60
0 - C
W - S
S
D 00-N100
CLARIFIED WATER
TO SOFTENING
CLARIFIERS
LSH
3503
LE
3021
AE
3020
TURBIDITY
50
0 - R
W - S
S
RW-3129
M
WEIR PLATE
M
100 - CW - PVCE 00-N100
COAGULANT
FROM EXISTING
SYSTEM
CH
-3
13
3
60
0 - R
W - S
S
60
0 - R
W - S
S
DV-3514
DD
PTW-3524
VFD
YS
3006
RE
MO
TE
SE
LE
CT
ED
DI
MN
3006
ST
AR
T/S
TO
P
CO
MM
AN
D
DO
MM
3006
RU
N
ST
AT
US
DI
UA
3006
FA
UL
T
ST
AT
US
DI
SC
3006
SP
EE
D
CO
NT
RO
L
AO
SI
3006
SP
EE
D
IN
DIC
AT
IO
N
AI
NA
3006
MO
IS
TU
RE
AL
AR
M
DI
TA
3006
TE
MP
ER
AT
UR
E
AL
AR
M
DI
LIC
3021
DI
LALH
3021
AI
F 00-N100
COAGULANT
FROM EXISTING
SYSTEM
10
0 - C
W - S
S
S16 SS
PVC
3006
P
RECYCLE PUMP
PTW-3525
HS1
3006
HOA
AIT
3504
TORQUE
SD
3005
MX
3004
MX
3003
MX
3002
AE
3502
pH
AIT
3502
DV-3513
CH
-3
13
5
CH
-3
13
4
CH
-3
13
6
RW-3130
YIC
3018
FA
L
YC
3018
FE
3018
FIT
3018
PI
3502
LIT
3021
DV-3516
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
ACTIFLO JET FLASH
MIXING UPGRADE P&ID
SHEET NUMBER
00-N101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
10
1.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
M
M
M
SEE 00-N201
RELOCATE SHUT
OFF VALVE
SEE DWG 03-D101
SEE 03-D101
H
I KJ
B
A
C D
E
SEE 03-D101
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
EXISTING CLARIFIER P&ID
(EXISTING PID107)
SHEET NUMBER
00-N200
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
20
0.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
RECARBONATION
CHAMBER FROM
CLARIFIERS 1 & 2
OZONE CONTACTOR
D
E 00-N200
TO CHANNEL
EXHAUST FAN
CONTROLS
CALCIUM THIOSULPHATE
DOUBLE WALL STORAGE
TANK
M
D 00-N200
OZONE
FROM OZONE
GENERATOR 1
A 00-N200
SOFTENED WATER
EXISTING
CLARIFIER 2
C 00-N200
CARBON DIOXIDE
CTH FEED PUMP
(DUTY)
M
CTH FEED PUMP
(STANDBY)
750x600 - OW
500 - SOW - SS
50 - IOA - SS
B 00-N200
SOFTENED WATER
EXISTING
CLARIFIER 1
500 - SOW - SS
15
- C
TH
- P
E
OZONE CONTACTOR
J 00-N200
OZONE
FROM OZONE
GENERATOR 2
H 00-N200
SOFTENED WATER
EXISTING
CLARIFIER 3
I 00-N200
CARBON DIOXIDE
500 - SOW - SS
50 - OIA - SS
750x600 - OW
YI
4249
DI
YI
4249
OF
F
DI
YI
4249
RU
NN
IN
G
IN
RE
MO
TE
DI
YA
4249
FA
IL
UR
E
DI
YL
4249
RE
MO
TE
TU
RN
ON
DI
CO2-5312
D D
RECARBONATION
CHAMBER FROM
CLARIFIER 3
D D
OD
-5
31
4
D
VFD
VFD
M
CTH FEED PUMP
(DUTY)
VFD
YI
4249
DI
YI
4249
OF
F
DI
YI
4249
RU
NN
IN
G
IN
RE
MO
TE
DI
YA
4249
FA
IL
UR
E
DI
YL
4249
RE
MO
TE
TU
RN
ON
DI
OZ
-4
22
1
DD
OZ
-5
31
8
DD
OZ
-5
31
8
VENDOR SKID BY SUPPLIER
15
- C
TH
- P
E
D D
D D
DISSOLVED
OZONE
DISSOLVED
OZONE
DISSOLVED
OZONE
DISSOLVED
OZONE
OZ
-5
31
6
OZ
-5
32
0
CALCIUM THIOSULPHATE
DOUBLE WALL STORAGE
TANK
OZ
-4
21
7
OZ
-4
21
5
OZ
-4
21
9
SPILL CONTAINMENT
5510
CMP
5530
CMP
5520
CMP
AF
5600
DI
AI
5600
CH
AN
NE
L
OZ
ON
E
AI
SI
5520
SP
EE
D
IN
DIC
AT
IO
N
AI
SC
5520
SP
EE
D
CO
NT
RO
L
A0
UA
5520
FA
UL
T
ST
AT
US
DI
MM
5520
RU
N
ST
AT
US
DI
MN
5520
ST
AR
T/S
TO
P
CO
MM
AN
D
DO
YS
5520
RE
MO
TE
SE
LE
CT
ED
DI
SI
5530
SP
EE
D
IN
DIC
AT
IO
N
AI
SC
5530
SP
EE
D
CO
NT
RO
L
A0
UA
5530
FA
UL
T
ST
AT
US
DI
MM
5530
RU
N
ST
AT
US
DI
MN
5530
ST
AR
T/S
TO
P
CO
MM
AN
D
DO
YS
5530
RE
MO
TE
SE
LE
CT
ED
DI
SI
5510
SP
EE
D
IN
DIC
AT
IO
N
AI
SC
5510
SP
EE
D
CO
NT
RO
L
A0
UA
5510
FA
UL
T
ST
AT
US
DI
MM
5510
RU
N
ST
AT
US
DI
MN
5510
ST
AR
T/S
TO
P
CO
MM
AN
D
DO
YS
5510
RE
MO
TE
SE
LE
CT
ED
DI
E 00-N200
OZONATED WATER
TO GRANULAR
MEDIA FILTERS
I
OZ
-5
32
1
OZ
-5
31
9
OZ
-5
31
7
OZ
-5
31
5
OZ
-4
22
0
OZ
-4
21
8
OZ
-4
21
6
OZ
-4
21
4
(SEE NOTE 1)
(SEE NOTES 1 & 2)
1. INSTALL 4 DISSOLVED OZONE ANALYZERS. EXACT
LOCATIONS TO BE DETERMINED BY ENGINEER.
2. CENTRE EACH PROBE BETWEEN THE BAFFLE
WALLS, EXACT LOCATION TO BE DETERMINED BY
ENGINEER.
AY
4252
DI
AI
4252
AI
AIT
4252
AE
4252
AY
4253
DI
AI
4253
AI
AIT
4253
AE
4253
AY
4254
DI
AI
4254
AI
AIT
4254
AE
4254
AY
4250
DI
AI
4250
AI
AIT
4250
AE
4250
TI
4250
AI
DISSOLVED
OZONE
DISSOLVED
OZONE
DISSOLVED
OZONE
DISSOLVED
OZONE
AY
5422
DI
AI
5422
AI
AIT
5422
AE
5422
AY
5421
DI
AI
5421
AI
AIT
5421
AE
5421
AY
5420
DI
AI
5420
AI
AIT
5420
AE
5420
AY
5419
DI
AI
5419
AI
AIT
5419
AE
5419
TI
5419
AI
RD
-5
31
3
OZ-5311
CO2-4211
OZ-4210
AE
5418
AIT
5418
AY
5418
AI
5418
OD
-4
21
3
RD
-4
21
2
AE
4251
AIT
4251
AY
4251
AI
4251
OZD-4249
OZD-4248
AIT
5600
AE
5600
HS1
HOA
HS1
HOA
HS1
HOA
PI
PI
PI
GENERAL NOTES
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
OZONE CONTACTOR
UPGRADES P&ID
SHEET NUMBER
00-N201
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
20
1.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
SEE 00-N301
SEE 00-N301
SEE 00-N301
B
C
A
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
EXISTING LIME FEED SYSTEM P&ID
(EXISTING P&ID 110)
SHEET NUMBER
00-N300
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
20
2.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
A 00-N300
LIME SLURRY
FROM LIME SLURRY
TANK
CH-5261
38
- C
AO
- P
VC
CH
-5
26
3
S
CH
-5
27
3
CH
-5
27
4
38
- C
AO
- P
E
CH
-5
26
4
S
CLARIFIER 1 CLARIFIER 2 CLARIFIER 3
38
- C
AO
- P
VC
S
CH
-5
27
6
38
- C
AO
- P
E
S
38
- C
AO
- P
VC
S
CH
-5
27
8
38
- C
AO
- P
E
S
B 00-N300
LIME SLURRY
FROM LIME SLURRY
TANK
C 00-N300
LIME SLURRY
FROM LIME SLURRY
TANK
CH
-5
27
5
CH
-5
27
7
OVERFLOW TO BE
DIRECTED INTO
CLARIFIER 1
BALL VALVE TO BE LOCATED AT
AN ELEVATION NO HIGHER
THAN 0.5m FROM TOP RUNG OF
WALKWAY. FLOW TO BE
REDIRECTED ONTO EDGE OF
WALKWAY TO FILL BUCKET
WITH SLURRY
OVERFLOW TO BE
DIRECTED INTO
CLARIFIER 2
BALL VALVE TO BE LOCATED AT
AN ELEVATION NO HIGHER
THAN 0.5m FROM TOP RUNG OF
WALKWAY. FLOW TO BE
REDIRECTED ONTO EDGE OF
WALKWAY TO FILL BUCKET
WITH SLURRY
OVERFLOW TO BE
DIRECTED INTO
CLARIFIER 3
BALL VALVE TO BE LOCATED AT
AN ELEVATION NO HIGHER
THAN 0.5m FROM TOP RUNG OF
WALKWAY. FLOW TO BE
REDIRECTED ONTO EDGE OF
WALKWAY TO FILL BUCKET
WITH SLURRY
CH-5262
CH-5265
CH
-5
26
7
CH
-5
26
8
CH-5266
CH-5269
CH
-5
27
1
CH
-5
27
2
CH-5270
CLARIFIER 1 CLARIFIER 2 CLARIFIER 3
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
LIME CONVEYANCE
SYSTEM UPGRADES P&ID
SHEET NUMBER
00-N301
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
30
1.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
40 - CLS - PVC
CH
-5
35
0
CHLORINE POINT OF APPLICATION
(DIFFUSERS NOT SHOWN)
CH-5351
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
EXISTING FLUORIDE & PHOSPHORIC
ACID P&ID (EXISTING PID112)
SHEET NUMBER
00-N400
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
40
0.D
WG
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
raw
in
g h
as b
ee
n p
re
pared
fo
r th
e use
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot be
u
se
d, rep
ro
du
ced
o
r relie
d up
on
by th
ird
p
arties, e
xce
pt a
s a
gre
ed
by A
EC
OM
a
nd its clie
nt, a
s re
qu
ire
d by la
w o
r fo
r u
se
by go
ve
rnm
en
tal re
vie
win
g a
ge
ncie
s. A
EC
OM
acce
pts no
respo
nsib
ility, an
d de
nie
s a
ny lia
bility w
ha
tso
eve
r, to a
ny pa
rty tha
t m
odifies th
is d
raw
in
g w
itho
ut A
EC
OM
's e
xpress w
ritte
n co
nsent. D
o no
t sca
le this d
ocu
me
nt. A
ll m
ea
surem
en
ts m
ust b
e ob
tain
ed from
state
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
DIAGRAMS & SCHEMATICS
PROCESS MECHANICAL
EXISTING McKAY RESERVOIR P&ID
(EXISTING P&ID P09)
SHEET NUMBER
00-N500
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\N
\6
05
08
94
4-S
HT
-N
50
0.D
WG
SE
E 05-E
101
VFD VFD
SE
E 05-E
101
YS
104
RE
MO
TE
SE
LE
CT
IO
N
DI
MN
104
ST
AR
T/S
TO
P
CO
MM
AN
D
DO
MM
104
RU
N
ST
AT
US
DI
UA
104
FA
UL
T
ST
AT
US
DI
SC
104
SP
EE
D
CO
NT
RO
L
AO
SI
104
SP
EE
D
IN
DIC
AT
IO
N
AI
YS
105
RE
MO
TE
SE
LE
CT
IO
N
DI
MN
105
ST
AR
T/S
TO
P
CO
MM
AN
D
DO
MM
105
RU
N
ST
AT
US
DI
UA
105
FA
UL
T
ST
AT
US
DI
SC
105
SP
EE
D
CO
NT
RO
L
AO
SI
105
SP
EE
D
IN
DIC
AT
IO
N
AI
HS
104
HOA
HS
104
HOA
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
D
C
B
A
1 2 3 4
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
PRE-TREATMENT BUILDING
PROCESS MECHANICAL
ACTIFLO JET FLASH MIXING
PIPING LAYOUT
SHEET NUMBER
02-D101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
2-D
10
0.D
WG
PRE-TREATMENT PLAN
Scale 1:50
N
100 - CW - PVC
WEIR PLATE
SEE DETAIL 3/02-D301
100 - CW - PVC
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
46
0±
25
00
±
610±
B
02-D301
A
02-D301
TIE INTO EXISTING 600Ø
RAW WATER PIPE.
SEE DETAIL 2/02-D301
1050±
200±
19955±
345±
200±
22
00
±
3006
P
PORTABLE LIFTING DAVIT WITH
WALL-MOUNTED BASE.
EXISTING REMOVABLE
GRATING
49
40
±
AIR PRESSURE RELIEF VALVE
15
00
±
0 1250 2500
mm
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
DCBA
NOTES:
1. GALVANIZE ALL METAL PARTS AND HARDWARE
2. SUITABLE FOR WALL OR FLOOR SUPPORTED PIPE
GRINNEL OFFSET
PIPE CLAMP
GRINNEL OFFSET
PIPE CLAMP
HV ANCHOR
HV ANCHOR
SIZE & LENGTH TO SUIT
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
PRE-TREATMENT BUILDING
PROCESS MECHANICAL
ACTIFLO JET FLASH MIXING
SECTIONS & DETAILS
SHEET NUMBER
02-D301
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
2-D
30
1.D
WG
600 - RW - SS
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
EXISTING POINTS OF
CHEMICAL APPLICATION
A JET MIXING SECTION
02-D101
Scale 1:50
EL. 264.750m
600x600x500Ø
EXISTING SS TEE
EXTEND EXISTING POINTS
OF CHEMICAL APPLICATION
TO CENTER OF EXISTING
600Ø PIPE, PROVIDE
SUPPORT AS REQUIRED
100x65 REDUCER
FEMALE 65Ø SS 316 NOZZLE
2 COAGULANT JET MIXING DETAIL
02-D101
02-D301
N.T.S.
2
02-D301
ANGLE 75x100x6
16Ø SS HILTI KWIK
EXPANSION ANCHORS
(KB11) MIN. 100
EMBEDDED
CHANNEL 100x35x8
16Ø SS A325 BOLTS
NOTES:
1. ALL STEEL MATERIAL TO BE GALVANIZED.
2. ALL ANCHORS AND BOLTS TO BE 316 SS.
3. GUIDE RAIL SUPPORT SHALL BE SUPPLIED BY
PUMP VENDOR.
5 GUIDE RAIL SUPPORT PLATE DETAIL
02-D301
N.T.S.
SS WEIR PLATE
1040x400x10 THK
ANGLE 50x75x440
HILTI HIT-HY 200
EXPANSION ANCHORS 10Ø
SS MIN 100 EMBEDDED
3 WEIR PLATE INSTALLATION DETAIL
02-D101
N.T.S.
B SUMP PUMP SECTION
02-D101
Scale 1:50
1050
40
0
SECTION
PLAN
TOC EL 265.707m
TOP OF FLOOR
EL 271.400m
EXISTING REMOVABLE
GRATING
100 - CW - SS
100 - CW - PVC
CL EL. 273.960m
100 - CW - PVC
CL EL. 268.707m
S16 SS
PVC
TIE INTO EXISTING
600x600x500Ø RAW
WATER TEE, PROVIDE
AN AIR TIGHT SEAL
EL.267.235m
1500±
180±
1440±
1705±
40
(T
YP
)
100 - CW - PVC
100 - CW - SS
PROVIDE AIR TIGHT SEAL
GUIDE RAIL BY PUMP
SUPPLIER. SEE
4/02-D301 FOR RAIL
SUPPORT DETAILS.
PIPE SUPPORT SEE
DETAIL 1/02-D301
3006
P
PTW-2523
PTW-3524
1 OFFSET PIPE SUPPORT DETAIL
02-D301
03-D103
03-D301
N.T.S.
AIR PRESSURE RELIEF VALVE
WALL-MOUNTED BASE.
HALLIDAY PRODUCTS,
STAINLESS STEEL TYPE-304DV2
SOCKET OR APPROVED EQUAL
100 - CW - PVC
CL EL. 273.960m
PUMP GUIDE RAIL
1050
85
GUIDE RAIL SUPPORT PLATE.
SEE 5/02-D301 FOR DETAILS
4 RAIL SUPPORT DETAIL
02-D301
N.T.S.
SUBMERSIBLE PUMP GUIDE
PORTABLE LIFTING DAVIT.
HALLIDAY PRODUCTS, D2B36D
OR APPROVED EQUAL
15
55
02
5
300
215
107
6 PUMP ANCHOR DETAILS
02-D301
N.T.S.
18
20
4 - 18mm Ø HOLES
FOR HV ANCHOR
NOTES:
1. COORDINATE BOLT HOLE SIZES AND
LOCATIONS WITH PUMP VENDOR PRIOR TO
COMMENCING WORK.
SEE 6/02-D301 FOR BOLT
ANCHOR DETAILS
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
4 5
7 8 9
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
PROCESS MECHANICAL
FLOW MANAGEMENT
PLANS & DETAILS
SHEET NUMBER
03-D101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
3-D
10
1.D
WG
B CLARIFIER 1 & 2 NEW MAGNETIC FLOW METER SECTION
03-D101
Scale 1:30
NEW MAGNETIC FLOW METER - EXISTING CLARIFIERS NO. 1 & 2
Scale 1:50
NEW MAGNETIC FLOW METER - EXISTING CLARIFIER NO. 3
Scale 1:50
B
03-D101
EXISTING 400Ø PIPE TO
CLARIFIER NO. 1
NEW 400Ø MAGNETIC
FLOW METER
2
4
0
0
1
0
2
5
EXISTING 600Ø CLARIFIER
NO. 3 INFLUENT LINE
NEW 500Ømm MAGNETIC
FLOW METER
EXISTING
CONTROL VALVE
EXISTING
500Ø PIPE
RELOCATED EXISTING CI
4203 CONTROL VALVE.
NEW 500x400Ø
REDUCER (TYP.)
1
6
0
0
8
3
0
NEW 500x400Ø
REDUCER (TYP.)
NEW 400Ø MAGNETIC
FLOW METER
NEW 400Ø MAGNETIC
FLOW METER
EXISTING VALVE
400 - PW - SS
N
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
EXISTING BLIND FLANGE
FOR FUTURE USE
1
0
0
0
±
2
5
0
0
±
A CLARIFIER 3 NEW MAGNETIC FLOW METER SECTION
03-D101
Scale 1:50
A
03-D101
EXISTING BLIND FLANGE
FOR FUTURE USE
1000±
2500
NEW 500Ømm MAGNETIC
FLOW METER
EXISTING
CONTROL VALVE
EXISTING 600x500Ø
REDUCER
EXISTING
CONTROL
VALVE
EXISTING
CONTROL
VALVE
NEW 400Ø
MAGNETIC
FLOW METER
RELOCATED EXISTING CI 4203
CONTROL VALVE.
500 - PW - SS
FE - 4205
FE - 4206
FE - 5302
FE - 5302
FE - 4206
FE - 4205
N
0 1250 2500
mm
0 1250 2500
mm
CLARIFIER 1
OZONE
CHAMBER
CLARIFIER
2
CLARIFIER
3
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
65 79 10
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
PROCESS MECHANICAL
OZONE QUENCHING
PLAN
SHEET NUMBER
03-D102
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
3-D
10
2.D
WG
15Ø DIFFUSER
1500±
OZONE
CHAMBER
12
00
±
VENDOR SUPPLIED CALCIUM
THIOSULPHATE METERING PUMP SKID
FOR CLARIFIERS 1, 2, AND 3 COMPLETE
WITH SPILL CONTAINMENT
(2 DUTY, 1 STAND-BY)
DOUBLE WALL CALCIUM
THIOSULPHATE STORAGE TANK
N
A
03-D301
15 - CTH - PE
(TYP.)
MAIN FLOOR PLAN
Scale 1:75
100
55
0±
25
50
±
47
75
±
100±
16
90
±
10
0±
100±
13970±
100±
52
50
±
33
85
±
14
70
±
1470±3385±
19
10
±
1910±
15Ø DIFFUSERS
1150±
APPROXIMATE LOCATION OF
EXISTING EYEWASH STATION
NEW EYEWASH STATION,
LOCATION TO BE CONFIRMED
ON SITE BY ENGINEER
SEE NOTES 1 & 2
SEE NOTE 1
1. INSTALL 4 DISSOLVED OZONE ANALYZERS, SEE DETAIL
3/03-D301 FOR DETAILS. EXACT LOCATIONS TO BE
DETERMINED BY ENGINEER.
2. CENTRE EACH PROBE BETWEEN THE BAFFLE WALLS,
EXACT LOCATION TO BE DETERMINED BY ENGINEER.
EXISTING
BAFFLES (TYP)
0
mm
1875 3750
02
TK
01
TK
GENERAL NOTES
CLARIFIER
3
CLARIFIER
2
RECARBONATION
CHAMBER
OZONE CHAMBER
FILTER 1 FILTER 2
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
4 5 6 7 9 10 11
12
13
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
PROCESS MECHANICAL
CHLORINATION
BASEMENT PLAN
SHEET NUMBER
03-D103
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
3-D
10
3.D
WG
INSTALL NEW 40Ø BALL VALVE
(N.C). ON EXISTING PIPE
EXISTING 100Ø PVC PIPE
CONTAINING 40Ø CHLORINE
& 12Ø FLUORIDE PIPES TO
METERING CHAMBER
40Ø SHUT OFF
BALL VALVE
BASEMENT FLOOR PLAN
Scale 1:75
N
40 - CLS - PVC
TO GAC FILTERS.
SEE DWG 03-D104
FOR CONTINUATION
12
0
6655±7385±
12
0
60
5
29
0±
315
195
12
0±
2800±
28
00
±
50
80
±
5080±
55
75
±
5575± 13155±
1
03-D103
1 PIPING DETAIL
03-D103
Scale 1:30
OFFSET PIPE SUPPORT (TYP.)
SEE 1/02-D301 FOR DETAILS
58
4±
30
0±
0
mm
1875 3750
CLARIFIER
3
CLARIFIER
2
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
11
12
13
14
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
PROCESS MECHANICAL
GAC BUILDING
PLANS & SECTIONS
SHEET NUMBER
03-D104
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
3-D
10
4.D
WG
A GAC BUILDING SECTION
03-D102
Scale 1:50
50Ø DIFFUSER C/W
10Ø HOLES AT 40mm
APART
80
0
800
FLOOR MOUNTED
SUPPORT BY
CONTRACTOR
WASTE CHANNEL
EFFLUENT SUMP
EFFLUENT CHANNEL
B DIFFUSER SUPPORT DETAIL
03-D104
Scale 1:30
750Ø EFFLUENT TO CLEAR
WATER RESERVOIR LINE
750Ø EFFLUENT TO CLEAR
WATER RESERVOIR LINE
1 DIFFUSER DETAIL
03-D104
Scale 1:30
1
03-D104
GAC FILTER PLAN
Scale 1:50
B
03-D104
30
0±
18
99
0±
32
0±
A
03-D104
120±
3370±
710±
FLOOR MOUNTED SUPPORT
BY CONTRACTOR
TO BASEMENT FLOOR PLAN.
SEE DWG 03-D103 FOR
CONTINUATION
40 - CLS - PVC
40 - CLS - PVC
N
2590±
120±
3370±
50
50
50
50±
710±25±
40x50Ø REDUCER
40x50 REDUCER
0 1250 2500
mm
FILTER 4
FILTER 3
FILTER 2
FILTER 1
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
LOC OFF REM
CHM-PUMP 1
LOC OFF REM
CHM-PUMP 2
LOC OFF REM
CHM-PUMP 3
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
PROCESS MECHANICAL
OZONE QUENCHING
SECTIONS & DETAILS
SHEET NUMBER
03-D301
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\D
\6
05
08
94
4-S
HT
-0
3-D
30
1.D
WG
800
80
0
15Ø DIFFUSER WITH HOLES
AGAINST FLOW DIRECTION.
SEE SUPPLIER FOR
INSTRUCTIONS (TYP.)
1 DIFFUSER DETAIL
03-D301
N.T.S.
A METERING PUMP SKID SECTION
03-D102
Scale 1:50
18
00
CALCIUM THIOSULPHATE
DOUBLE WALL 2.84m³
STORAGE TANK (TYP.)
VENDOR METERING PUMP SKID
FOR CLARIFIERS 1, 2 & 3 COMPLETE
WITH SPILL CONTAINMENT
(2 DUTY AND 1 STAND-BY)
1
03-D301
100 MIN 100 MIN
ROUGHEN CONCRETE
SURFACE
15M @ 300 o/c TOP, E.W.
A-BOLTS AS REQUIRED BY
EQUIPMENT SUPPLIER,
DRILL AND EPOXY GROUT
EXISTING CONCRETE
SUPPORT SLAB
NOTES:
1. SIZE, NUMBER, TYPE, LOCATION AND THREAD PROJECTION OF
ANCHOR BOLTS IS TO BE DETERMINED BY THE EQUIPMENT SUPPLIER.
2. BASES SHALL BE LEVEL UNLESS NOTED OTHERWISE.
3. CONTRACTOR TO SIZE AND LOCATE PAD REINFORCEMENT TO SUIT
ANY ALTERNATIVE BOLT ARRANGEMENTS.
2 TYPICAL HOUSEKEEPING PAD DETAIL
03-D301
N.T.S.
15M DOWELS @ 300 o/c
AROUND PERIMETER,
DRILLED AND EPOXY
GROUTED 130mm INTO
CONCRETE. UTILIZING HILTI
HIT HY-150 ADHESIVE.
MIN TWO DOWELS PER SIDE.
20mm CHAMFER
(TYP.)
15
0 M
IN
AS
R
EQ
UIR
ED
15 - CTH - PE
EL 264.262
EL 266.732
15 - CTH - PE
TO CHANNEL FROM
CLARIFIER 3
CL EL 268.132m
15 - CTH - PE
TO CHANNEL FROM
CLARIFIERS 1&2
CL EL 268.232m
TO CHANNEL FROM
CLARIFIER 3
CL EL 268.132m
TRUCK FILL
POINT (TYP.)
NOTES:
1. TYPICAL FOR CHANNEL FROM CLARIFIER 1 & 2 AS WELL AS
CHANNEL FROM CLARIFIER 3.
2
03-D301
PIPE OFFSET PIPE SUPPORT (TYP.)
SEE 1/02-D301 FOR DETAILS
NOTES:
1. REFER TO PROCESS DRAWINGS FOR SAMPLE TAP LOCATIONS.
2. ALL SAMPLE AND FLUSHING PIPE VALVES AND FITTINGS ARE
12mm THREADED STAINLESS STEEL.
3. GRAB SAMPLE TAPS AND VALVES ARE 4mm STAINLESS STEEL.
4. EACH OZONE PROBE SHALL BE SUPPLIED WITH TWO PROBE
HOLDERS TO FACILITATE SAMPLING FLEXIBILITY.
5. SAMPLE PIPE LENGTH UPSTREAM OF THE PROBE HOLDER TO BE
KEPT SHORT.
SAMPLE TAP (TYP)
SEE NOTE 3
ROTAMETER O-3L/MIN
TO DRAIN
VENT
CABLES TO PLC
AND POWER
SOURCE
50
0
50
0
1000
PROBE HOLDER (TYP)
SEE NOTE 4
HIGH WATER LEVEL
12x38mm REDUCER (TYP)
OZONE
ANALYZER
PIPE SUPPORT (TYP)
<500 NOTE 5
NOTE 2
MANUAL
VENT
FUTURE
CABLE
1000 <500 NOTE 5
FLUSH
VALVE (TYP)
CORED HOLE WITH LINKSEAL.
SEE NOTE 1
3 ANALYZER INSTALLATION DETAIL
03-D102
N.T.S.
TYPICAL DISSOLVED OZONE
OZONE
CONTACTOR
ORIGINALLY
SIGNED BY
S. R. BILEVICIUS
DEC.06.2016
DUCT FLEXIBLE CONNECTION
DUCT c/w ACOUSTIC INSULATION
MOTORIZED DAMPER
BACKDRAFT DAMPER
OUTDOOR AIR (DOWN)
FIRE DAMPER
SUPPLY AIR (DOWN)
EXHAUST AIR (DOWN)
RETURN AIR (DOWN)
OA
MD
BDD
F
EA
RA
SA
WW-X
YYY
ZZZ
DESCRIPTION
GENERAL SYMBOLS
SYMBOL
GRILLE/LOUVER TAG IDENTIFICATION
CONTROL SYMBOLS
DISCONNECT
MOTORIZED DAMPER
BACK-DRAFT DAMPER
DESCRIPTIONSYMBOL
AIR FLOW DIRECTION
OUTDOOR AIR (UP)
SUPPLY AIR (UP)
EXHAUST AIR (UP)
RETURN AIR (UP)
OA
EA
RA
SA
#
# : QUANTITY (x2, x3, x4 ...)
WW : AIR TYPE ABBREVIATION
X : SEQUENCE NUMBER IN A TYPE
YYY : AIR SECTION SIZE (mm x mm)
ZZZ : AIR FLOW (l/s)
ABOVE FINISHED FLOOR
OZONE GASO
AFF
NC
MISC. ABBREVIATIONS
TYPICALTYP
NORMALLY OPENNO
NORMALLY CLOSED
MOTORIZED EQUIPMENT TAG
EQUIPMENT
ABBREVIATION
SEQUENCE LETTER OF
SAME TYPE EQUIPMENT
MUA
300A
SEQUENCE
NUMBER
FEX-1
EQUIPMENT
ABBREVIATION
NON-MOTORIZED EQUIPMENT
AND ACCESSORY TAG
SEQUENCE
NUMBER OF
EQUIPMENT
CONTROL SEQUENCES
SECOND FLOOR OZONE VENTILATION
SUPPLY AND INSTALL ALL REQUIRED COMPONENTS TO ACHIEVE THE CONTROL SEQUENCES DESCRIBED IN THE TENDER
DOCUMENTS.
VENTILATION SYSTEM MAIN SELECTOR SWITCH:
1. ON:
a. SYSTEM OPERATES CONTINUOUSLY
b. GREEN LED LIGHT ON PANEL TO INDICATE EXHAUST FAN EF-1 OPERATION
c. GENERAL INDICATION TO BUILDING MONITORING SYSTEM.
2. OFF:
a. SYSTEM DOES NOT OPERATE
3. AUTO:
a. SYSTEM OPERATES BASED ON GAS DETECTION ALARM SIGNALS
b. GREEN LED LIGHT ON PANEL TO INDICATE EXHAUST FAN EF-1 OPERATION
c. GENERAL ALARM SIGNAL TO BUILDING MONITORING SYSTEM.
VENTILATION SYSTEM OPERATION:
1. ZERO LEVEL ALARM:
a. EF-1 AND MUA - 1 NORMALLY OFF UNLESS THERE IS A LOW OR HIGH LEVEL ALARM SIGNAL FROM GAS DETECTOR
CONTROL.
2. LOW LEVEL ALARM SIGNAL FROM GAS DETECTOR CONTROL
a. EXHAUST FAN EF-1 DAMPER OPENS AND PROVES OPEN PRIOR TO START OF EXHAUST FAN EF - 1
b. EXHAUST FAN EF-1 STARTS ON LOW SPEED
c. MAKE UP AIR UNIT MUA-1:
i INTERNAL DAMPER OPENS
ii FAN OPERATES.
iii DISCHARGE TEMPERATURE SET TO 21C/70F
iv HEATING IS ENABLED AND CONTROLLED BY INTERNAL SCR
3. HIGH LEVEL ALARM SIGNAL FROM GAS DETECTOR CONTROL PRIOR TO START OF EXHAUST FAN EF-1
a. EXHAUST FAN DAMPER OPENS OR REMAINS OPEN AND PROVES OPEN
b. EXHAUST FAN AT HIGH SPEED
c. MAKE UP AIR UNIT: AS ABOVE
4. ON SIGNAL FROM SELECTOR SWITCH:
a. AS PER OPERATION FOR HIGH LEVEL ALARM.
SYSTEM OPERATION WILL BE INTERMITTENT, BASED ON AMBIENT AIR OZONE DETECTION AS FOLLOWS:
OZONE DETECTION SYSTEM
WILL PROVIDE TWO ALARMS BASED ON DETECTION IN THE GENERAL AREA ABOVE THE CENTER OF THE 4 FILTER UNITS.
LOW LEVEL ALARM: 0.04 PPMV (ADJUSTABLE)
1. VENTILATION ACTIVATES AT LOW SPEED
2. LOCAL AUDIBLE AND VISUAL ALARM ON DETECTION SYSTEM CONTROLLER.
3. "CHANNEL EXHAUST ON" ALARM TO GENERAL BUILDING CONTROL/ALARM SYSTEM.
HIGH LEVEL ALARM: 0.1 PPMV (ADJUSTABLE)
1. VENTILATION TO HIGH SPEED
2. LOCAL AUDIBLE AND VISUAL ALARM ON DETECTION SYSTEM CONTROLLER.
3. "2ND FLOOR OZONE" ALARM TO GENERAL BUILDING CONTROL/ALARM SYSTEM.
MAIN FLOOR - NORTH SIDE CHEMICAL/FLUORIDE ROOM VENTILATION
1. NEW EXHAUST FAN WILL RUN CONTINUOUSLY FROM ON/OFF SWITCH.
2. SWITCH ON: EXHAUST FAN OPERATES CONTINUOUSLY.
DESIGN NOTES:
SECOND FLOOR OZONE VENTILATION
OZONE VENTILATION BASED ON THE FOLLOWING CONDITIONS:
1. DOORS BETWEEN THE 2ND FLOOR FILTER AREA AND ALL OTHER 2ND FLOOR ROOMS ARE NORMALLY
CLOSED AND THERE IS NO AIR TRANSFER.
2. THERE IS NO VENTILATION ON THE MAIN FLOOR AROUND THE FILTER AREA.
3. OZONE LEVELS IN THE EXHAUST AIRSTREAM COLLECTED OVER CHANNELS WILL BE LESS THAN 0.3 PPM
BY VOLUME AND THUS CAN BE DISCHARGED TO ATMOSPHERE WITHOUT USE OF OZONE DESTRUCT
SYSTEM.
4. WATER LEVEL IN THE CHANNELS FROM THE OZONE CONTACTORS TO THE FILTERS IS APPROXIMATELY
MID-HEIGHT OF THE 300mm HIGH X 800mm WIDE CHANNELS.
5. BOTTOM OF SLUICE GATES IS APPROXIMATELY 200mm ABOVE CHANNEL WATER LEVEL.
6. AIRFLOW BASED ON MAINTAINING A MINIMUM VELOCITY OF 0.3 m/sec (50FPM) IN ANY CHANNEL COVER
GAPS AND OPENINGS AT LOW EXHAUST FAN SPEED OPERATION. ESTIMATED MAXIMUM 4MM GAP
BETWEEN COVERS.
7. SINGLE SPEED MAKE-UP AIR UNIT APPROXIMATELY MATCHES CHANNEL EXHAUST FAN MAXIMUM AIR
FLOW RATE. UNIT WILL PROVIDE ADDITIONAL AIR AND ROOM HEATING WHEN EXHAUST FAN OPERATING
AT LOW SPEED ONLY.
MAIN FLOOR - NORTH SIDE CHEMICAL/FLUORIDE ROOM VENTILATION
FLOROSILICIC ACID VENTILATION BASED ON FOLLOWING CONDITIONS:
1. EXISTING VENTILATION, GRAVITY INLETS AND UNIT HEATERS ARE BASED ON SEPT 30/2003 COCHRANE
ENGINEERING LTD. AS-BUILT DRAWING INFORMATION.
2. EXISTING EXHAUST FAN OPERATING SEQUENCES, COMBINED WITH EXISTING GRAVITY AIR SUPPLIES
AND UNIT HEATERS WILL PROVIDE SUFFICIENT MAKE-UP AIR FOR THE NEW EXHAUST.
3. VENTILATION PROVIDED DIRECTLY FROM HOOD OVER TOP COVER OF CHEMICAL TOTE CONTAINER WITH
CAPTURE VELOCITY 0.6m/s (100FPM) OR BETTER.
4. NO OTHER ROOM CONTAMINANTS REQUIRE VENTILATION.
MD
3
DC
BDD
EF
MAKE-UP AIRMUA
EXHAUST FAN
ITEM DESCRIPTION, LOCATION OR AREA SERVED MAKE MODEL FAN DATA ELECTRICAL DATA COMMENTS
MOTOR HEATING TOTAL VOLTS PHASE STARTER
DETAILS
AIRFLOW
LOW / HIGH
(LPS)
EXTERNAL S.P.
AT HIGH FLOW
(Pa)
HP kW kW kW Man HOA
EF1 FILTER CHANNEL EXHAUST FAN LOREN - COOK SQN-B 70 140 400 0.50 0.375 0 0.4 120 1 - X BELT DRIVE, TWO SPEED TEFC MOTOR.
ALUMINUM HOUSING. ALUMINUM WHEEL.
SUITABLE FOR CEC SECTION 22 WET
LOCATION.
EF2 CHEMICAL ROOM - HYDROFLUORISILICIC ACID
TOTE EXHAUST
PLASTEC P15-2 70 425 0.50 0.375 0 0.4 120 1 X - DIRECT DRIVE TEFC MOTOR.
POLYPROPYLENE HOUSING AND WHEEL.
SUITABLE FOR CEC SECTION 22 WET
LOCATION.
MAU1 2ND FLOOR FILTER AREA THERMOLEC MINI-MAKE-UP
FER-10-10-600/3
N/A 140 35 0 0 10 10.0 575 3 - X BUILT IN BACKDRAFT DAMPER, AND
SPEED CONTROL. SCR CONTROLLED
HEATING. INTEGRAL WASHABLE FILTER
FAN SCHEDULE
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
MECHANICAL
LEGENDS, DESIGN NOTES
AND CONTROL SEQUENCES
SHEET NUMBER
03-H001
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\H
\6
05
08
94
4-0
3-H
00
1.D
WG
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
ORIGINALLY
SIGNED BY
C.A.D.
COURCHAINE
DEC.06.2016
REMOVABLE S.S. COVERS ON CHANNELS
FROM OZONE CONTRACTOR TO
SAND FILTER SPLITTER (TYP)
SEE DETAIL 1/H401
REMOVABLE S.S. COVERS ON CHANNELS (TYP)
SEE DETAIL 1/H401
FILTER NO. 1 FILTER NO. 2
FILTER NO. 4 FILTER NO. 3
EXISTING CONCRETE
CHANNEL
EXISTING
CONCRETE
CHANNEL
EXISTING
FILTER SPLITTER BOX
CLARIFIER NO. 2
EXISTING
STORAGE
STAIRWELL NO. 3 STAIRWELL
NO. 2
CLARIFIER NO. 3
SERVICE ROOM
MAIN FLOOR
150Ø
200Ø EXHAUST RISING
TO SECOND FLOOR
150Ø
EXISTING WALL-MOUNTED SLUICE GATE
ADJUST COVER LENGTH AS REQUIRED TO
SUIT SLUICE GATE LOCATION.
BUTT UP TO EACH SIDE OF SLUICE GATE FRAME
EXISTING WALL-MOUNTED SLUICE GATE
ADJUST COVER LENGTH AS REQUIRED TO
SUIT SLUICE GATE LOCATION.
TERMINATE WITHIN 6mm OF SLUICE GATE
EPDM FLAP AT FIRST COVER INLET
TO FLUME (TYP) SEE 1/03-H401 FOR DETAILS
OZONE CONTACTOR DISCHARGE
IF COVERS REQUIRED
APPLY DECAL ON COVERS AS SHOWN.
MINIMUM 25mm HIGH RED CHARACTERS ON WHITE
VINYL BACKGROUND:
"DO NOT STAND, WALK OR APPLY LOAD ON COVERS"
TYPICAL OF FOUR FOR EACH CHANNEL
CLARIFIER NO. 3
EPDM FLAP AT EACH END COVER
LOCATION (TYP. OF 2)
COVER TO BUTT UP TO EDGE OF
WALL COVERING
SITE CONFIRM ACCESS TO TOP OF
CHANNEL BETWEEN OZONE
CONTRACTOR AND WALL.
PROVIDE COVERS IF CHANNEL IS OPEN
EPDM FLAP AT SPLITTER WEIR
(TYP. OF 2)
SEE TENDER DOCUMENTS
AND SPECIFICATIONS REGARDING
FLOOR TILE REPAIRS
SEE DETAIL 2/H401 FOR
DUCT CONNECTION
SEE DETAIL 2/H401 FOR
DUCT CONNECTION
C1
C2
D
E
4 5 6
7 8
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
MECHANICAL
MAIN FLOOR FILTERS
EXHAUST MODIFCATIONS
SHEET NUMBER
03-H101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\H
\6
05
08
94
4-0
3-H
10
1.D
WG
MAIN FLOOR FILTERS - EXHAUST MODIFICATIONS
Scale 1:50
0 1250 2500
mm
N
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
GENERAL NOTES
1. ALL EXHAUST DUCTWORK AND FITTINGS TO BE 316 S.S.
AND MANUFACTURED TO SMACNA STANDARDS.
2. CONTRACTOR TO FIELD VERIFY ALL LOCATIONS AND
DIMENSIONS.
3. CO-ORDINATE INSTALLATION WITH ALL OTHER TRADES.
4. DRAWING IS DIAGRAMMATIC AND INTENDED TO SHOW
DESIGN INTENT ONLY.
5. INSTALL ALL EQUIPMENT IN COMPLETE ACCORDANCE
WITH MANUFACTURER'S PRINTED INSTRUCTIONS.
ORIGINALLY
SIGNED BY
C.A.D.
COURCHAINE
DEC.06.2016
CHEMICAL
ROOM
MAIN FLOOR
10 11 12 1398
EXISTING FLUORIDE
CHEMICAL TOTE
FLEXIBLE/HARD
DUCTING FROM HOOD
TO FAN. SEE DETAIL 7/H401
REMOVABLE HOOD
ON TOTE
SEE DETAIL 7/H401
CLARIFIER NO. 3
SILO SERVICE
ROOM MAIN
FLOOR
BDD
EXISTING FAN
EF-5032 TO REMAIN
EXISTING
AIR INLET
EXISTING COMBUSTION
AIR DUCT
DC
MANUAL DISCONNECT
(LOCKABLE)
EF
2
DISCONNECT AND REMOVE EXISTING FAN
AND FLEXIBLE DUCTING AND TURN OVER
TO OWNER. CAP AND SEAL OPENING
IN BUILDING VENT PIPE.
SEE FAN SUPPORT
DETAIL 5/H401
100Ø PVC DISCHARGE UP THROUGH
SECOND FLOOR AND ROOF TO 3M ABOVE
ROOF PARAPET.
MAINTAIN MIN. 3M FROM COMBUSTION
AIR AND OTHER INLETS. SEE DETAIL 8/H401
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
MECHANICAL
CHEMICAL ROOM
EXHAUST MODIFICATIONS
SHEET NUMBER
03-H102
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\H
\6
05
08
94
4-0
3-H
10
2.D
WG
CHEMICAL ROOM - EXHAUST MODIFICATIONS
Scale 1:50
0 1250 2500
mm
N
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
GENERAL NOTES
1. CONTRACTOR TO FIELD VERIFY ALL LOCATIONS AND
DIMENSIONS.
2. CO-ORDINATE INSTALLATION WITH ALL OTHER TRADES.
3. DRAWING IS DIAGRAMMATIC AND INTENDED TO SHOW
DESIGN INTENT ONLY.
4. INSTALL ALL EQUIPMENT IN COMPLETE ACCORDANCE
WITH MANUFACTURER'S PRINTED INSTRUCTIONS.
ORIGINALLY
SIGNED BY
C.A.D.
COURCHAINE
DEC.06.2016
CORRIDOR
ELECTRICAL
ROOM
STORAGE
WR
FILTER NO. 2
(BELOW)
FILTER NO. 3
(BELOW)
CONTROL
ROOM
LABORATORY
PLANT
SUPERINTENDENT
OZONE
GENERATING
ROOM
EF
1
200Ø EXHAUST
DISCHARGE
RISING THROUGH ROOF
TO STACKHEAD. SEE
DETAIL 3/H401
200Ø EXHAUST RISING FROM
FILTER CHANNELS BELOW
O
3
LV-1
450x450
-
SG-1
250x250
140
MUA
1
MD-1
MD
GD-1 (AE/AIT-5600)
OZONE GAS DETECTION/MONITOR
CONTROLLER. MOUNT ABOVE
HANDRAIL, FACE FLUSH WITH
WALKWAY. ALL WIRING FROM
OVERHEAD. KEEP CONTINUITY OF
HANDRAIL. REFER TO DIV. 17 FOR
WIRING DETAILS
SENSOR TUBE
3mm I.D./6mm O.D.
MAX. 5M LONG
OZONE GAS SENSOR TUBE
INLET WITH FILTER AT
300mm ABOVE FLOOR.
INSTALL ON LOWER
HANDRAIL. APPLY
LAMACOID IDENTIFICATION
200Ø
200Ø
SEE DETAIL 6/H401
D
E
C1
C2
4 5 6
7
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
MECHANICAL
SECOND FLOOR FILTERS
EXHAUST MODIFICATIONS
SHEET NUMBER
03-H103
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\H
\6
05
08
94
4-0
3-H
10
3.D
WG
SECOND FLOOR FILTERS - EXHAUST MODIFICATIONS
Scale 1:50
0 1250 2500
mm
N
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
GENERAL NOTES
1. ALL EXHAUST DUCTWORK AND FITTINGS TO BE 316 S.S.
AND MANUFACTURED TO SMACNA STANDARDS.
2. CONTRACTOR TO FIELD VERIFY ALL LOCATIONS AND
DIMENSIONS.
3. CO-ORDINATE INSTALLATION WITH ALL OTHER TRADES.
4. DRAWING IS DIAGRAMMATIC AND INTENDED TO SHOW
DESIGN INTENT ONLY.
5. INSTALL ALL EQUIPMENT IN COMPLETE ACCORDANCE
WITH MANUFACTURER'S PRINTED INSTRUCTIONS.
ORIGINALLY
SIGNED BY
C.A.D.
COURCHAINE
DEC.06.2016
ELEVATION 3M
ABOVE ROOFLINE
4 x D
15
0m
m M
IN
.
316SS EXHAUST STACK
HANGER RODS SIZED AS
PER SPECIFICATION
ANGLE IRON OR CHANNEL
SIZED AS PER SPECIFICATION
ALL GALVANIZED STEEL UNLESS
OTHERWISE NOTED
RADIUS SHARP CORNERS
NUT AND
LOCKING NUT
HANGER RODS SIZED AS
PER SPECIFICATION
NUT AND
LOCKING NUT
METAL BAND
150mm MAX
BOTH SIDES
SQUARE / RECTANGULAR DUCT HANGER
ROUND DUCT HANGER
NOTES:
1) HANGERS MUST NOT DEFORM DUCT SHAPE.
2) DO NOT EXCEED ALLOWABLE LOAD LIMITS.
3 EXHAUST STACKHEAD
-
Scale NTS
4 DUCTWORK SUPPORT AND HANGER DETAIL
-
Scale NTS
1200mm
800mm (TYP.)
1 REMOVABLE CHANNEL COVER AND FLAP DETAIL
-
Scale NTS
EXISTING
CONCRETE FLUME
NOTE:
COVERS SHALL BE 316 SS AND MINIMUM 1.5M (16 GAUGE) THICK , MILL FINISH
MAXIMUM INDIVIDUAL COVER WEIGHT: 15 kG
SIDE VIEW AT FIRST COVER
END VIEW
EXISTING
CONCRETE FLUME
CHANNEL
COVER
2 DUCT CONNECTION COVER
-
Scale NTS
50
150Ø I.D.
C
L
SEGMENT COVER
SIDE VIEW
10
00
mm
PVC COATED FIBREGLASS
FLEXIBLE DUCT 90%
EXTENDED WHEN ON COVER
D = 200Ø
SEE ROOF PENETRATION
DETAIL 8/H401
GUY WIRE
SUPPORT
25mm MINERAL OR
GLASS FIBRE INSULATION
WITH FSK JACKET BACK
TO MOTORIZED DAMPER
AT EXHAUST FAN
WATER FLOWWATER
FOLD END OF COVER
MAXIMUM GAP BETWEEN
COVERS: 4mm
5Ø x 25 LONG 316 SS
CAP SCREW FENDER WASHER
AND SELF-LOCKING NUT
ON 150mm CENTERS
6mm EPDM RUBBER FLAP x 800 WIDE x 300 HIGH
TRIM FOR AVERAGE 12mm CLEARANCE ABOVE
WATER SURFACE (TYPICAL AT END AND
SPLITTER WEIR COVERS)
5 FAN SUPPORT FROM WALL DETAIL
-
Scale NTS
6 EXHAUST FAN DUCT RISER
-
Scale NTS
EXHAUST FAN
EF-1
25mm MINERAL OR GLASS FIBRE
INSULATION WITH FSK JACKET
BACK TO MOTORIZED DAMPER AT
EXHAUST FAN
MOTORIZED
DAMPER
19Ø BALL VALVE
SECURE TO WALL
EXHAUST DUCT RISING TO
STACKHEAD ON ROOF.
SEE DETAIL 3/H401
7 REMOVABLE TOTE ON HOOD
-
Scale NTS
8 ROOF PENETRATION
-
Scale NTS
CLEAR VINYL HOSE
SECURE TO WALL
D + 25mm
900
50
30
0
FLEXIBLE DUCT CLAMP
TO ADAPTOR
SLIP FIT 316SS ADAPTOR
INTO COVER OUTLET
316SS COVER OUTLET
15
0
NOTE: ALL SEAMS WELDED.
(TYPICAL OF TWO)
WALL
100Ø PVC
100Ø FLEXIBLE DUCT
CONNECTION PVC
COATED FIBREGLASS
20
00
M
IN
.
300
100Ø
50
10
0
4
5
°
SIDE VIEW
30
0
TOP VIEW
CONTINUOUS CAULKING
PRE-FINISHED METAL HOOD WITH CLAMPING RING
CONTRACTOR TO PROVIDE RIGID INSULATION
INFILL ALL AROUND PENETRATION c/w 2 LAYERS
OF 3.2 THICK RECOVERY BOARD STAGGERED
PRE-FINISHED METAL BOX (SOLDERED IF TWO PIECES)
CONTINUOUS BEAD OF MASTIC
PRIMER
CAP SHEET
BASE SHEET, LAPPED WITH EXISTING ROOF BASE SHEET
BASE SHEET
EXISTING TWO-PLY MOPPED VAPOUR BARRIER,
BITUMEN ROOF
EXISTING STEEL ROOF DECK
UV RESISTANT PVC
ABOVE ROOF
PROVIDE MINIMUM OF TWO
RIGID BRACES, OR THREE
GUY WIRES TO ROOF
OR PARAPET
775
1.2
M
AF
F
ANCHORS
SEE NOTE 2
WALL
EXHAUST FAN
NOTES:
1) EACH WALL ANCHOR SHALL SATISFY
THE FOLLOWING:
A. TENSILE LOAD = 9 x DUCT WEIGHT;
SAFETY FACTOR OF 4
B. SHEAR LOAD = 15 x DUCT WEIGHT;
SAFETY FACTOR OF 4
2) SECURE WITH APPROVED ANCHORS
TO MATCH WALL CONSTRUCTION
LENGTH TO SUIT
DRAIN LINE AT
LOW POINT
TRANSITION TO MATCH
DUCT OR 316SS
316SS BRACKET
SUBMIT SHOP
DRAWING
EXISTING
FLUORIDE
CHEMICAL TOTE
316SS DUCT/PIPE
HANGER (TYP)
200x200
12
00
316SS HOOD
SUPPORT
100Ø
FLEXIBLE PVC COUPLING
100Ø
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
MECHANICAL
DETAILS
SHEET NUMBER
03-H401
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\H
\6
05
08
94
4-0
0-H
40
1.D
WG
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
ORIGINALLY
SIGNED BY
C.A.D.
COURCHAINE
DEC.06.2016
ACTIFLO RECYCLE PUMP
3006
P
D
C
B
A
EXISTING PANEL '30B'
XFMR MOUNTED ABOVE
EXISTING CDP-30A
CABINET WITH VFD AND
FILTERS FOR ACTIFLO
RECYCLE PUMP P-3006
3 4
1 2
D
C
B
A
225A
3P
EXISTING LOADS
225A, 600/347 V, 3 PH, 4 W, 25kA
EXISTING CDP-30A
15
HP
ACTIFLO
RECYCLE PUMP
P-3006
40A
3P
5% LINE
REACTOR
DV/DT
OUTPUT
FILTER
VFD
40A, 600V
NEMA 4X
ENCLOSURE
3/C #8 AWG
DRIVE RATED
TECK CABLE
3/C #8 AWG
DRIVE RATED
TECK CABLE
3/C #8 AWG
TECK CABLE
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
PRE-TREATMENT BUILDING
ELECTRICAL
PRE-TREATMENT PLAN
SHEET NUMBER
02-E101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\E
\6
05
08
94
4-0
2-E
10
1.D
WG
SECOND FLOOR PRE-TREATMENT PLAN
Scale 1:50
N
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
MAIN FLOOR PRE-TREATMENT PLAN
Scale 1:50
CDP-30A SINGLE LINE DIAGRAM
N.T.S.
N
0 1250 2500
mm
N
0 1250 2500
mm
2016/12/06
ORIGINALLY
SIGNED BY
B. BOGDANOV
DEC.06.2016
RECEPTACLE FOR METERING PUMP
60B-16
NOTE 1
654
79 10
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
MAIN BUILDING
ELECTRICAL
MAIN FLOOR PLAN
SHEET NUMBER
03-E101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\E
\6
05
08
94
4-0
3-E
10
1.D
WG
CLARIFIER NO. 2
CLARIFIER NO. 3
RECARBONATION
CHAMBER
N
MAIN FLOOR PLAN
Scale 1:75
1. PROVIDE AND INSTALL 15A, 1 POLE, 120V BREAKER TO
PANEL 60B cct.16. PROVIDE AND INSTALL 2C #12 TECK 90
CABLE FROM PANEL 60B, cct. 16 TO NEW METERING
PUMP RECEPTACLE.
N
0
mm
1875 3750
GENERAL NOTES
2016/12/06
ORIGINALLY
SIGNED BY
B. BOGDANOV
DEC.06.2016
EXISTING
MOTOR 105
NOTE 2
EXISTING
PUMP 106
EXISTING
PUMP 107
EXISTING
PUMP 108
EXISTING
PUMP 104
NOTE 2
EXISTING
PUMP 103
EXISTING
PUMP 102
EXISTING
PUMP 101
EXISTING MCC
CABINET WITH
VFD AND FILTERS
FOR PUMP 104
EXISTING SERVICE PUMPS
CONTROL PANEL
SEE NOTE 1
CABINET WITH
VFD AND FILTERS
FOR PUMP 105
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
McKAY RESERVOIR
ELECTRICAL
MAIN FLOOR PLAN
SHEET NUMBER
05-E101
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\E
\6
05
08
94
4-0
5-E
10
1.D
WG
MAIN FLOOR PLAN - ELECTRICAL
Scale 1:30
GENERAL NOTES
1. EXISTING SERVICE PUMPS CONTROL PANEL TO BE
DECOMMISSIONED.
2. REPLACE EXISTING MOTORS WITH NEW VFD RATED
MOTORS. DEMOLISH ALL EQUIPMENT ASSOCIATED
WITH PUMP EQUIPMENT, SUCH AS STARTER, CABLE
AND DISCONNECT. PROVIDE AND INSTALL NEW
EQUIPMENT AS SHOWN ON THE DRAWINGS.
0 750 1500
mm
2016/12/06
ORIGINALLY
SIGNED BY
B. BOGDANOV
DEC.06.2016
EXISTING
SERVICE PUMP
#101
EXISTING
SERVICE PUMP
#102
EXISTING
SERVICE PUMP
#103
EXISTING
SERVICE PUMP
#106
EXISTING
SERVICE PUMP
#107
EXISTING
SERVICE PUMP
#108
EXISTING
SERVICE ENTRANCE
MAIN BREAKER
EXISTING
AIR COMPRESSOR
#160
EXISTING
15 kVA 3Ø
TRANSFORMER FEED
SPACE
EXISTING
METERING
COMPARTMENT
EXISTING
TRANSFER
LOOP
EXISTING
AIR COMPRESSOR
#170
EXISTING
VENTILATION FAN
#150
EXISTING
VENTILATION FAN
#151
SPACE
SPACE
EXISTING
SERVICE PUMP
#104
NOTE 1
EXISTING
SERVICE PUMP
#105
NOTE 1
600A
3P
EXISTING
SERVICE PUMP
#101
EXISTING
SERVICE PUMP
#102
EXISTING
SERVICE PUMP
#103
3C #6 AWG
DRIVE RATED
TECK CABLE
EXISTING
SERVICE PUMP
#106
EXISTING
SERVICE PUMP
#107
EXISTING
SERVICE PUMP
#108
EXISTING
AIR COMPRESSOR
#160
EXISTING
AIR COMPRESSOR
#170
EXISTING
VENTILATION FAN
#150
EXISTING
VENTILATION FAN
#151
80A
3P
HARMONIC
FILTER
DV/DT
OUTPUT
FILTER
40
HP
EXISTING
SERVICE PUMP
#104
VFD
80A
3P
HARMONIC
FILTER
DV/DT
OUTPUT
FILTER
40
HP
EXISTING
SERVICE PUMP
#105
VFD
3C #6 AWG
TECK CABLE
Printed on ___% Post-Consumer
Recycled Content Paper
Th
is d
ra
win
g h
as b
ee
n p
re
pa
re
d fo
r th
e u
se
o
f A
EC
OM
's clie
nt a
nd
m
ay n
ot b
e u
se
d, re
pro
du
ce
d o
r re
lie
d u
po
n b
y th
ird
p
artie
s, e
xce
pt a
s a
gre
ed
b
y A
EC
OM
a
nd its clie
nt, as re
quired
by law
o
r fo
r u
se
b
y g
overn
me
nta
l review
in
g ag
en
cie
s. A
EC
OM
a
ccep
ts n
o resp
on
sib
ility, a
nd
d
en
ies an
y liab
ility w
ha
tso
eve
r, to
a
ny p
arty th
at m
od
ifie
s th
is d
ra
wing
w
itho
ut A
EC
OM
's exp
re
ss w
ritte
n con
se
nt. D
o n
ot sca
le th
is do
cu
me
nt. A
ll m
ea
sure
me
nts m
ust b
e o
btain
ed
fro
m sta
te
d dim
en
sion
s.
AN
SI D
8
64
mm
x 5
59
mm
REGISTRATION
CONSULTANT
AECOM
99 Commerce Drive
Winnipeg, Manitoba, R3P 0Y7
204.477.5381 tel 204.284.2040 fax
www.aecom.com
PROJECT
CITY OF PORTAGE
LA PRAIRIE
PHASE 1 WATER
TREATMENT PLANT
UPGRADES
PROJECT NUMBER
60508944
CLIENT
The Manitoba Water
Services Board
2010 Currie Boulevard
Brandon, MB, R7A 6Y9
NOTICE:
AS-CONSTRUCTED DIMENSIONS,
MEASUREMENTS AND OTHER DETAILS
CONTAINED IN THIS RECORD DRAWING
HAVE BEEN OBTAINED BY AECOM CANADA
LTD. ("AECOM") FROM VARIOUS SOURCES.
SUCH INFORMATION REPRESENTS THE
BEST INFORMATION AVAILABLE TO AECOM
AT THE TIME OF PREPARATION OF THIS
RECORD DRAWING. AECOM DOES NOT IN
ANY WAY REPRESENT OR WARRANT THAT
SUCH INFORMATION IS ACCURATE AND
ASSUMES NO RESPONSIBILITY FOR ANY
ERRORS OR OMISSIONS CONTAINED
THEREIN.
Certificate of Authorization
AECOM Canada Ltd.
No. 4671 Date:_____________
Original dated on:
2016/12/06
La
st sa
ve
d b
y: E
LL
IO
TT
S1(2
01
6-1
2-0
6) L
ast P
lo
tte
d: 2
01
6-1
2-0
6
SHEET TITLE
McKAY RESERVOIR
ELECTRICAL
EXISTING MCC ELEVATION
& SINGLE LINE DIAGRAM
SHEET NUMBER
05-E201
Pro
je
ct M
an
ag
em
en
t In
itia
ls:
De
sig
ne
r:
Ch
ecke
d:
Ap
pro
ve
d:
__
__
__
__
__
__
__
_
File
na
me
: P
:\6
05
08
94
4\9
00
-C
AD
, G
IS
\9
10
-C
AD
\2
0-S
HE
ET
S\E
\6
05
08
94
4-0
5-E
20
1.D
WG
SINGLE LINE DIAGRAM
N.T.S.
MCC ELEVATION
N.T.S.
I/R DATE DESCRIPTION
ISSUE/REVISION
0 2016/12/07 ISSUED FOR TENDER
2016/12/06
GENERAL NOTES
1. DEMOLISH ALL EXISTING EQUIPMENT FROM MCC CELLS.
PROVIDE AND INSTALL NEW BREAKER, NEW DOOR,
ASSOCIATED WITH BREAKER LOCKABLE HANDLE AND
MECHANICAL INTERLOCK TO PREVENT OPENING DOOR
IN ON POSITION.
ORIGINALLY
SIGNED BY
B. BOGDANOV
DEC.06.2016