LOCATION:5600 Explorer Drive, MississaugaOn Explorer Drive in the Airport Corporate Centre
PROPERTY DESCRIPTION:This four storey building is the first phase of the AeroCentre Complex. Thoughtful, intelligent design criteria have generated prestigious corner offices and a unique circular area on each floor, enhancing visual impact and maximizing views. Security and energy management systems ensure tenant safety and comfort. Located in the sophisticated business environment of the Airport Corporate Centre, AeroCentre offers convenient access to Highways 401, 427 and 403 and is less than 5 minutes to Pearson International Airport. Public transportation is provided by Mississauga Transit, the new Bus Rapid Transit project, the TTC and two exclusive AeroCentre Hybrid Shuttle Buses are available to tenants at no cost.
BUILDING CLASS: “A”
YEAR BUILT/REFURB: 1989
FLOORS (#): 4
TYPICAL FLOOR PLATE: 15,400 sf
TOTAL SIZE: 57,891 sf
PARKING TYPE: 3.2/1,000 sf
ADDITIONAL RENT (2017)
Realty Taxes: $ 4.92 psf
Operating Costs: $ 9.75 psf
Tenant Hydro Costs: $ 1.30 psf
Total Additional Rent: $15.97 psf
5600 EXPLORER DRIVEMISSISSAUGA, ONTARIO
AEROCENTRESOFFICES.COM
FOR MORE INFORMATION ON THE AEROCENTRE COMPLEX, PLEASE CONTACT:
www.jll.ca
© 2017 Jones Lang LaSalle IP, Inc. All rights reserved. All information contained herein is from sources deemed reliable; however, no representation or warranty is made to the accuracy thereof. E. & O. E. Jones Lang LaSalle Real Estate Services, Inc. Real Estate Brokerage. *Sales Representative January 2017
Michael Seetner*Transaction Manager+1 416 304 [email protected]
Michael Case*Senior Vice President, LEED AP +1 416 304 [email protected]
Matthew Kornmuller*Associate Vice President+ 1 905 755 [email protected]
Brett Elofson*Senior Vice President+1 416 304 [email protected]
NUMBER OF FLOORS: 4TOTAL SF: 57,891 sfOFFICE AREA SF: 57,891 sf
1. ExteriorThe exterior of the buiding consists primarily of double glazed blue vision glass and single glazed blue spandrel panels set on aluminum framed curtain wall assembly. The roof is a two ply torch down bitumen roof with ballast.
2. SecurityAfter-hours access to the building is provided through pass cards and they are programmed for limited access to the building. There are three CCTV cameras, one located at each entrance to the building and one exterior camera facing the driveway, all backed up into a 750 G digital video recorder.
3. MechanicalThe building is ventilated by six cooled air handling units complete with DX coil. The units are located one per floor with the ground floor unit being larger. The units supply air to the variable air volume boxes throughout the building. The VAV boxes are complete with pneumatic controls. The building is equipped with an air compressor that provides compressed air to the pneumatic controls. The mechanical air distribution systems, consists of compartmental air handlers that provides ventilation and cooling to each of the six floors, a cooling tower, gas fired boilers with Siemens night set back controls for energy efficiency. Two atmospheric hot water boilers provide perimeter radiant heating to all floors. All washrooms are equipped with water efficient and hands-free faucets, soap dispensers and urinals.
4. LightingThe building standard lighting is T8 and electronic ballast technology, compact fluorescent lamps in lobby and LED exit lights. Interior lights are managed by a computerized lighting control system. Override switches allow tenants to turn lights on in various work areas should they require additional lighting outside of regular business hours. These fixtures will automatically turn off after the override has been activated within two hours for added energy conservation. All washroom lights are on motion sensors for energy conservation.
5.Utility DistributionThe electrical power supply is provided from a transformer located on the ground floor in the electrical room providing 1200 amps and 347/600 volts of power.
6. Fire Safety SystemsThe building is equipped with sprinklers and a standpipe system. There are typically two fire hose cabinets, with extinguishers, per floor. The Simplex fire alarm panel controls detection points throughout the building and is monitored 24/7. Smoke and heat detectros and pull stations are located throughout the building.
7. ElevatorsTwo hydraulic elevators provide speed and convenience to all floors and include hands free communication to the emergency monitoring station.
8. Tenant ServicesMenkes uses Angus AnyWhereTM Tenant Service Request. This is a fully web enabled service management solution specifically designed for commercial real estate. Detailed service requests are submitted by tenants through the Menkes website and sent to the appropriate party for action. The real-time application interacts with handheld wireless messaging device to speed service delivery and ensure prompt service action. The management team reviews reports regularly to monitor the types and frequency of various service request.
8. EnvironmentalA risk management program run by RiskCheck Inc. provides Environmental, Health and Safety (EHS) Risk Management Service by correctly identifying, managing, and monitoring risks, and helping to establish the procedures to eliminate or control hazards. The program ensures properties respect compliance standards and that the best working practices are being followed. The monthly reports generated by RiskCheck, in addition to annual inspections, provide updates on the status of current levels of statutory compliance plus a general summary of current and planned initiatives.
5600 EXPLORER DRIVEMISSISSAUGA, ONTARIO
AEROCENTRESOFFICES.COM
BUILDING SPECIFICATIONS
FOR MORE INFORMATION ON THE AEROCENTRE COMPLEX, PLEASE CONTACT:
www.jll.ca
© 2017 Jones Lang LaSalle IP, Inc. All rights reserved. All information contained herein is from sources deemed reliable; however, no representation or warranty is made to the accuracy thereof. E. & O. E. Jones Lang LaSalle Real Estate Services, Inc. Real Estate Brokerage. *Sales Representative January 2017
Michael Seetner*Transaction Manager+1 416 304 [email protected]
Michael Case*Senior Vice President, LEED AP +1 416 304 [email protected]
Matthew Kornmuller*Associate Vice President+ 1 905 755 [email protected]
Brett Elofson*Senior Vice President+1 416 304 [email protected]
FHC
FHC
EGRESS
EGRESS
SUITE 101
SUITE 102
1 DEMOLITION PLANSCALE: 1/8"=1'-0"
PROJ#
DRAWING
PROJECT
SCALE
DRAWN
DO NOT SCALE THIS DRAWING.
CONTRACTOR TO CHECK AND VERIFY DIMENSIONS ON SITE,AND REPORT DISCREPANCIES TO X-DESIGN INC. BEFOREPROCEEDING WITH THE WORK.
DRAWINGS ARE THE PROPERTY OF X-DESIGN INC. AND MAYNOT BE REPRODUCED WITHOUT THE PERMISSION OF THEDESIGNERS.
SHEET#
DATE
CHECKED
1135 DUNDAS ST. EAST, SUITE 200 TORONTO, ON. M4M 1R9TEL: 416-462-3084 FAX: [email protected] www.xdesigninc.com
15-101 ID01
04/06/2016AS NOTED
X-DJF
PARTITION PLAN
MISSISSAUGA, ONSUITE, 1015600 EXPLORER DRIVEMENKES
5600 EXPLORER DRIVEMISSISSAUGA, ONTARIO
AEROCENTRESOFFICES.COM
SUITE 102
SUITE 101
Floors SF Availability Asking Rate CommentsSuite 101
7,556 Immediately $16.50 NetLobby-facing ground floor space with lots of natural light. 1 meeting room and server room with large common area.
Suite 102
3,630 Immediately $16.50 Net Lobby-facing ground floor space with lots of natural light. Base building condition.