PROPOSED DUPLEX FOR
IGNITE HOMES
LOT 120
FLINTWOOD ST
RURAL VIEW
JOB NUMBER - 5506
NOTES:
* IMAGES ARE DIAGRAMATIC ONLY* REFER TO ELEVATIONS FOR DETAILS
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
2 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
DESCRIPTIONREV. DATE
WORKING DRAWINGS ISSUEDA 100414
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans), TOBE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786.
WIND SPEED AS NOMINATED ON BRACING PLAN.
PROVIDE LIFT OFF HINGES TO W.C OR OPEN OUT DOOR OR MIN 1200mm CLEARANCEFROM DOOR TO PAN.
EXHAUST FANS FROM SANITARY COMPARTMENTS TO BE DUCTED TO THE OUTSIDEARE AIR OR TO A VENTED ROOF SPACE AND AS PER AS 1668.2
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGUALTIONS,STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACUAL OBLIGATIONS.
ALL CONSTRUCTION MATERIALS SUPPLIED MUST TAKE INTO ACCOUNT PROXIMITY TOCOASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCE WITH MANUFACTURERSSPECIFICATIONS
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THEAUTHOR.
IGNITE HOMESLOT 120
FLINTWOOD ST
RURAL VIEW
JOB NUMBER - 5506
GENERAL NOTES
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERINGMATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKSCONFORM TO THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIANSTANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS,REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OFAUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATIONAS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDINGAS 1684 - 2010 NATIONAL TIMBER FRAMING CODEAS 2049 - 2002 ROOF TILESAS 2050 - 2002 INSTALLATION OF ROOF TILESAS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTIONAS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGSAS 3600 - 2000 CONCRETE STRUCTURESAS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITESAS 3700 - 2001 MASONRY IN BUILDINGSAS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGSAS 3786 - 1993 SMOKE ALARMSAS 4055 - 2006 WIND LOADINGS FOR HOUSINGAS 4100 - 1998 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVILENGINEERING COMPUTIONS AND DRAWINGS.
SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCEWITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOXINDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOORii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASEiii) FULLY GLAZED DOORSiv) SHOWER SCREENSv) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVELvi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARYWITH MANUFACTURER, FLASHING ALL ROUND.
ALL GUTTERS TO BE STRAMIT QUEENSLANDER QUAD GUTTERING WITH MIN. 100x75RECTANGULAR OR 100 dia. DOWNPIPES, EACH DOWNPIPE SHALL SERVICE A MAXIMUMROOF AREA OF 36 sq.m OR SHALL BE POSITIONED AS PER AS 3500.3, 2003, SECTION 3.
STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BYTHE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVERTHEFLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OFPARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALLCORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT ISRECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITYOF BUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BEIMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OFTHE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL ANDWITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sqFOR INTERNAL WALLS BELOW BEARER.
THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5 BATTS AND REFLECTIVE FOILTO EXTERNAL WALLS OR AS PER ENERGY RATING.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND INACCORDANCE WITH BCA 3.9.2FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADECONSTRUCTION - REQUIRED WIRE TENSION AND MAXIMUM PERMISSIBLEDEFLECTION) OF THE BCA..
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OFEXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
LEGEND
CJ CONSTRUCTION JOINT
DP DOWNPIPE
FP FIRE PLACE
FW FLOOR WASTE
HWS HOT WATER SYSTEM
AC AIR CONDITIONING
PS PLUMBING STACK / DUCT
SP STEEL POST
T.B.C TO BE CONFIRMED
RL RELATIVE LEVEL
AHD AUSTRALIAN HEIGHT DATUM
CSD CAVITY SLIDING DOOR
OHC OVER HEAD CUPBOARD
FG FIXED GLASS
FSR FLOOR SPACE RATIO
LB LOAD BEARING
NGL NATURAL GROUND LINE
UBO UNDER BENCH OVEN
WO WALL OVEN
DW DISHWASHER
MW MICROWAVE
WM WASHING MACHINE
WIR WALK-IN-ROBE
SD SLIDING GLASS DOOR
ASW ALUMINIUM SLIDING WINDOW
ADH ALUM. DOUBLE HUNG WINDOW
AAW ALUM. AWNING WINDOW
ALW ALUM. LOUVRE WINDOW
BCA BUILDING CODE OF AUSTRALIA
AS AUSTRALIAN STANDARDS
SITE NOTES
ALL STORMWATER AND DRAINAGE TO BE IN COMPLIANCE WITH BCAPARTS 3.1.2 & 3.5.2 AS WELL AS AS/NZS 3500.
ENSURE 90mm DIAMETER AGRICULTURAL DRAINS ARE PROVIDED TOTHE BASE OF ALL CUTS AND RETAINING WALLS AND ARE CONNECTEDTO THE STORMWATER SYSTEM VIA SILT PIT/S TO THE RBSREQUIREMENTS.
THE EXTERNAL FINISHED SURFACE SURROUNDING THE BUILDINGMUST BE DRAINED TO MOVE SURFACE WATER AWAY FROM THEBUILDING AND GRADE TO PROVIDE A SLOPE NOT LESS THAN 50mmOVER THE FIRST 1000mm FROM THE BUILDING.
A MINIMUM HEIGHT OF 150mm SHALL BE MAINTAINED BETWEEN THETOP OF THE OVERFLOW GULLY RISER & THE LOWEST FIXTURECONNECTED TO THE DRAIN. THE OVERFLOW GULLY RISER SHALL BELOCATED AT 75mm ABOVE SURROUNDING GROUND LEVEL OR SHALLBE FINISHED AT A HEIGHT TO PREVENT THE INGRESS OF WATERWHEN LOCATED IN A PATH OR PAVED AREA.
CONNECT DOWNPIPES TO LEGAL POINT OF DISCHARGE VIA 100mmDIAMETER UPVC STORMWATER PIPE LAID WITH A MINIMUM FALL OF1:100, DISCHARGE TO THE SATISFACTION OF THE RELEVANTAUTHORITY.
ALL STORMWATER DRAINAGE BELOW GROUND SHALL BE SEWERGRADE WITH NO JOINTS UNDER SLAB INSTALLED TO AS3500.3, 2003.MINIMUM PIPE SIZE 100mmMINIMUM GRADE 1:100
ALL POOL FENCING SHALL BE MIN. 1200mm HIGH AND INACCORDANCEWITH AS 1926.1
PROPOSED DUPLEX FOR
CV
AMENDS TO WORKING DRAWINGSB 170414CV
AMENDS TO WORKING DRAWINGS - ADDED BLOCKING DETAILSC 280414CV
LANDSCAPING & GARDEN SHED ADDEDD 160514RH
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
3 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
REPORT STATUS DATE
WORKPLACE HEALTH & SAFETY REPORTCOMPLETED - DISCUSSED WITH & PROVIDED TOCLIENT ALONG WITH WORKING DRAWINGS 100414
IGNITE HOMESLOT 120
FLINTWOOD ST
RURAL VIEW
JOB NUMBER - 5506
b) SLIPPERY OR UNEVEN SURFACESFLOOR FINISHES
Specified finishes have been selected to minimise the risk of floors andpaved areas becoming slippery when wet or when walked on with wetshoes/feet. Any changes to the specified finish should be made inconsultation with the designer or, if this is not practical, surfaces with anequivalent or better slip resistance should be chosen.
The owner is responsible for the selection of surface finishes in thepedestrian trafficable areas of this building. Surfaces should be selected inaccordance with AS HB 197:1999 and AS/NZ 4586:2004.
STEPS, LOOSE OBJECTS AND UNEVEN SURFACES
Due to design restrictions for this building, steps and/or ramps are includedin the building which may be a hazard to workers carrying objects orotherwise occupied. Steps should be clearly marked with both visual andtactile warning during construction, maintenance, demolition and at all timeswhen the building operates as a workplace.Building owners and occupiers should monitor the pedestrian access waysand in particular access to areas where maintenance is routinely carried outto ensure that surfaces have not moved or cracked so that they becomeuneven and present a trip hazard. Spills, loose material, stray objects orany other matter that may cause a slip or trip hazard should be cleaned orremoved from access ways.Contractors should be required to maintain a tidy work site duringconstruction, maintenance or demolition to reduce the risk of trips and fallsin the workplace. Materials for construction or maintenance should bestored in designated areas away from access ways and work areas.
2. FALLING OBJECTSLOOSE MATERIALS OR SMALL OBJECTS
Construction, maintenance or demolition work on or around this building islikely to involve persons working above ground level or above floor levels.Where this occurs one or more of the following measures should be takento avoid objects falling from the area where the work is being carried outonto persons below.
1. Prevent or restrict access to areas below where the workis being carried out.
2. Provide toeboards to scaffolding or work platforms.3. Provide protective structure below the work area.4. Ensure that all persons below the work area have
Personal Protective Equipment.
BUILDING COMPONENTS
During construction, renovation or demolition of this building, parts of thestructure including fabricated steelwork, heavy panels and many othercomponents will remain standing prior to or after supporting parts are inplace. Contractors should ensure that temporary bracing or other requiredsupport is in place at all times when collapse which may injure persons inthe area is a possibility.
Mechanical lifting of materials and components during construction,maintenance or demolition presents a risk of falling objects. Contractorsshould ensure that appropriate lifting devices are used, that loads areproperly secured and that access to areas below the load is prevented orrestricted.
3. TRAFFIC MANAGEMENTParking of vehicles or loading/unloading of vehicles on this roadway maycause a traffic hazard. During construction, maintenance or demolition ofthis building designated parking for workers and loading areas should beprovided. Trained traffic management personnel should be responsible forthe supervision of these areas.
Construction of this building will require loading and unloading of materialson the roadway. Deliveries should be well planned to avoid congestion ofloading areas and trained traffic management personnel should be used tosupervise loading/unloading areas.
Busy construction and demolition sites present a risk of collision wheredeliveries and other traffic are moving within the site. A traffic managementplan supervised by trained traffic management personnel should beadopted for the work site.
4. SERVICESRupture of services during excavation or other activity creates a variety ofrisks including release of hazardous material. Existing services are located
on or around this site. Where known, these are identified on the plans butthe exact location and extent of services may vary from that indicated.Services should be located using an appropriate service (such as DialBefore You Dig), appropriate excavation practice should be used and,where necessary, specialist contractors should be used.(in locations with underground power)
Underground power lines are located in or around this site. All undergroundpower lines must be disconnected or carefully located and adequatewarning signs used prior to any construction, maintenance or demolitioncommencing.(in locations with overhead power lines )
Overhead power lines are near or on this site. These pose a risk ofelectrocution if struck or approached by lifting devices or other plant andpersons working above ground level. Where there is a danger of thisoccurring, power lines should be, where practical, disconnected orrelocated. Where this is not practical adequate warning in the form of brightcoloured tape or signage should be used or a protective barrier provided.
5. MANUAL TASKSComponents within this design with a mass in excess of 25kg should belifted by two or more workers or by mechanical lifting device. Where this isnot practical, suppliers or fabricators should be required to limit thecomponent mass.All material packaging, building and maintenance components shouldclearly show the total mass of packages and where practical all itemsshould be stored on site in a way which minimises bending before lifting.Advice should be provided on safe lifting methods in all areas where liftingmay occur.Construction, maintenance and demolition of this building will require theuse of portable tools and equipment. These should be fully maintained inaccordance with manufacturer’s specifications and not used where faulty or(in the case of electrical equipment) not carrying a current electrical safetytag. All safety guards or devices should be regularly checked and PersonalProtective Equipment should be used in accordance with manufacturer’sspecification.
6. HAZARDOUS SUBSTANCESASBESTOS
(for alterations to a building constructed prior to 1990)
This building was constructed prior to 1990 and therefore may containasbestos either in cladding material or in fire retardant insulation material.The builder should check and, if necessary, take appropriate action beforedemolishing, cutting, sanding, drilling or otherwise disturbing the existingstructure.(for alterations to a building constructed prior to 1986)
This building was constructed prior to 1986 and therefore is likely to containasbestos either in cladding material or in fire retardant insulation material.The builder should check and, if necessary, take appropriate action beforedemolishing, cutting, sanding, drilling or otherwise disturbing the existingstructure.
POWDERED MATERIALS
Many materials used in the construction of this building can cause harm ifinhaled in powdered form. Persons working on or in the building duringconstruction, operational maintenance or demolition should ensure goodventilation and wear Personal Protective Equipment including protectionagainst inhalation while using powdered material or when sanding, drilling,cutting or otherwise disturbing or creating powdered material.
TREATED TIMBER
The design of this building includes provision for the inclusion of treatedtimber within the structure. Dust or fumes from this material can be harmful.Persons working on or in the building during construction, operationalmaintenance or demolition should ensure good ventilation and wearPersonal Protective Equipment including protection against inhalation ofharmful material when sanding, drilling, cutting or using treated timber inany way that may cause harmful material to be released. Do not burntreated timber.
VOLATILE ORGANIC COMPOUNDS
Many types of glue, solvents, spray packs, paints, varnishes and somecleaning materials and disinfectants have dangerous emissions. Areaswhere these are used should be kept well ventilated while the material isbeing used and for a period after installation. Personal ProtectiveEquipment may also be required. The manufacturer’s recommendations foruse must be carefully considered at all times.
SYNTHETIC MINERAL FIBRE
Fibreglass, rockwool, ceramic and other material used for thermal or soundinsulation may contain synthetic mineral fibre which may be harmful ifinhaled or if it comes in contact with the skin, eyes or other sensitive partsor the body. Personal Protective Equipment including protection againstinhalation of harmful material should be used when installing, removing orworking near bulk insulation material.
TIMBER FLOORS
This building contains timber floors which have an applied finish. Areaswhere finishes are applied should be kept well ventilated during sandingand application and for a period after installation. Personal ProtectiveEquipment may also be required. The manufacturer’s recommendations foruse must be carefully considered at all times.
7. CONFINED SPACESEXCAVATION
Construction of this building and some maintenance on the building willrequire excavation and installation of items within excavations. Wherepractical, installation should be carried out using methods which do notrequire workers to enter the excavation. Where this is not practical,adequate support for the excavated area should be provided to preventcollapse. Warning signs and barriers to prevent accidental or unauthorisedaccess to all excavations should be provided.
ENCLOSED SPACES
Enclosed spaces within this building may present a risk to persons enteringfor construction, maintenance or any other purpose. The designdocumentation calls for warning signs and barriers to unauthorised access.These should be maintained throughout the life of the building. Whereworkers are required to enter enclosed spaces, air testing equipment andPersonal Protective Equipment should be provided.
SMALL SPACES
Some small spaces within this building will require access by constructionor maintenance workers. The design documentation calls for warning signsand barriers to unauthorised access. These should be maintainedthroughout the life of the building. Where workers are required to entersmall spaces they should be scheduled so that access is for short periods.Manual lifting and other manual activity should be restricted in smallspaces.
8. PUBLIC ACCESSPublic access to construction and demolition sites and to areas undermaintenance causes risk to workers and public. Warning signs and securebarriers to unauthorised access should be provided. Where electricalinstallations, excavations, plant or loose materials are present they shouldbe secured when not fully supervised.
9. OPERATIONAL USE OF BUILDINGThis building has been designed to requirements of the specific buildingclassification identified within the drawings. Where a change of use occursat a later date a further assessment of the workplace health and safetyissues should be undertaken, in accordance with the provisions of the WorkHealth and Safety Act 2011 or subsequent replacement Act.
(Where the specific use of the building is not known at the time of thecompletion of this report and a further assessment of the workplace healthand safety issues should be undertaken at the time of fit-out for the end-user.)
10. OTHER HIGH RISK ACTIVITYAll electrical work should be carried out in accordance with Code ofPractice: Managing Electrical Risks at the Workplace, AS/NZ 3012 and alllicensing requirements.All work using Plant should be carried out in accordance with Code ofPractice: Managing Risks of Plant at the Workplace.
All work should be carried out in accordance with Code of Practice:Managing Noise and Preventing Hearing Loss at Work.
Due to the history of serious incidents it is recommended that particularcare be exercised when undertaking work involving steel construction andconcrete placement. All the above applies.
WORKPLACE HEALTH &
SAFETY REPORT
Compiled in accordace with Work Health andSafety Act 2011.
IDENTIFIED HAZARD AREAS
1. FALLS, SLIPS, TRIPSa) WORKING AT HEIGHTSDURING CONSTRUCTION
Wherever possible, components for this building should be prefabricatedoff-site or at ground level to minimise the risk of workers falling more thantwo metres. However, construction of this building will require workers to beworking at heights where a fall in excess of two metres is possible andinjury is likely to result from such a fall. The builder should provide asuitable barrier wherever a person is required to work in a situation wherefalling more than two metres is a possibility.
DURING OPERATION OR MAINTENANCE
Cleaning and maintenance of windows, walls, roof or other components ofthis building will require persons to be situated where a fall from a height inexcess of two metres is possible. Where this type of activity is required,scaffolding, ladders or trestles should be used in accordance with relevantcodes of practice, regulations or legislation.
Cleaning and maintenance of windows, walls, roof or other components ofthis building will require persons to be situated where a fall from a height inexcess of two metres is possible. Where this type of activity is required,scaffolding, fall barriers or Personal Protective Equipment should be used inaccordance with relevant codes of practice, regulations or legislation.
Anchorage points for portable scaffold or fall arrest devices have beenincluded in the design for use by maintenance workers. Any personsengaged to work on the building after completion of construction workshould be informed about the anchorage points.
PROPOSED DUPLEX FOR
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
4 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 292482
0
820
820
820 720 820720
820
820
820
520
820 820
820
820
12-15asw09-06asw
18-0
6adh
18-0
6adh
21-2
4 p
anelif
t doo
r
12-2
4asw
21-24SD
21-2
4SD
06-18asw
09-06asw
21-2
4 p
anelif
t doo
r
12-15asw
09-12asw
21-2
4SD
D.P D.P D.PD.P
D.P
D.P
D.P
278° 7
' 0"
19.0
35
188° 7' 0" 35
98° 7
' 0"
19.0
35
188° 7' 0" 35
2755
3980
3530
3980
6000
5000
3940
2265
2305
6840
3490
5000
PROPOSED SINGLE STOREY
2x UNIT DEVELOPMENT
Lot No. 120SITE AREA - 666Sq.mSITE COVERAGE - 35.58%PADRL - T.B.CFFLRL - T.B.C
Letterbox
Letter box
Fence & Gate
Fence & Gate
Electrical
mains
Proposed Boundaryline for Subdivision
1400mm x 800mmRubbish bin slab
2400mm x 1600mmClothes line slab.Clothesline to be bolted to wall
1200mm x600mm A/C slab
1400mm x 800mmRubbish bin slab
1200mm x600mm A/C slab
1200mm x 600mmA/C slab
1200mm x 600mmA/C slab
2400mm x 1600mm Clothes lineslab.Clothes line to be bolted to wall
Grey Concrete todriveway from boundary
to gutter
600mm x 600mm Hotwater system slab
600mm x 600mm Hotwater system slab
BINS
BINS
Sewer
ConnectionPoint
IL - 10.538
Electrical PitStormwaterConnection Point
Stormwater
ConnectionPoint
Water PipeWater
Connection Point
Stormwater Line
3000mm x2000mm shedslab
3000mm x2000mmshed slab
tap METERBOX
tap
taptap
To
Wa
ll
To
Fa
scia
To
Wa
ll
To
Fa
scia
To Wall
To Garage Wall
To Eave
To
Wa
ll
To
Fa
scia
To
Wa
ll
To
Wa
ll
Lot 125B
363.12Sq.m
Lot 125A
303.10Sq.m
5Sq.m
Garden bed
5Sq.m
Garden bed
A/C
A/C
A/C
A/C
A/C
A/C
A/CA/C
METERBOX
Stormwater Line
FL
IN
TW
OO
D
ST
RE
ET
SW
S
SW
WW
WW
SITE PLAN
SCALE 1:200 SHEET 4 OF 19 JOB NUMBER - 5506
** 1:5 MAX DRIVEWAY SLOPE TO LOCAL GOVERNMENTREQUIREMENTS AND STANDARDS **
................................
................................
................................
................................
00.000CUT
00.000
-----F.L
FILL
GL 00.000G.L
approx.
NOTES:* Discharge waste to connection point* Provide sediment control to site where req'd* Discharge stormwater to TANK, where possible,all other stormwater & overflow to kerb & channel* Meter box position T.B.C on site* All retaining walls by owner
**NOTE** ALL STORMWATER & DRAINAGE TO BE IN COMPLIANCE WITH BCA PARTS 3.1.2. & 3.5.2. ASWELL AS ASNZS3500* GUTTERS TO BE 125MM D-SECTION COLORBOND GUTTERS* 2 DOWNPIPES MAX. TO EACH 100mm STORMWATER PIPE, SUBSURFACE PIPES TO BE 100mmDIAMETER, ANY UNDERSLAB PIPING TO HAVE AN INSPECTION OPENING AT UPPER END, THEN TO
BE 100mm SEWER GRADE PIPING WITH NO JOINS UNDER SLAB.
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
5 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
820
820
820
820 720 820720
820
820
820
520
820 820
820
820
12-15asw09-06asw
18-06adh
18-06adh
21-24 panelift door
12-24asw
21-24SD
21-24SD
06-18asw
09-06asw
21-24 panelift door
12-15asw
09-12asw
21-24SD
REF.
W.M.
PROV
W.M.
PROV
DW
PROV
REF. DW
PROV
D.P D.P D.PD.P
D.P
D.P
D.P
1000 22160
110130760 6070 5080 4790 3720 2500
230 5840 230 4850 110 4570 110 3490 230 2250 90 160
20090
153390
153390943
3501240
2301800 70 3000 90 2100 70
6001200
600250 3350 230
230 6000 70730 70
1000 70 3000 90 2100 70 700 5300 230
230 6800 70 12330 230
13200
450
3070
4530
40
4660
450
110
340
230
2840
230
4070
230
40
230
4200
230
340
110
450
160
90
2820
4570
160
90
4160
90
160
450
450
230
3450
70
3620
230
40
230 1000
70
3700
110
110
2060
70
1440
70
4070
230
40
230
1000
70
2130
70
1500
110
450
230
3000
70
980
90
3000
230
40
230
1000
70
3130
230
23160
9390 2020 3730 3060 2460 2500
230 9160 110 1800 110 3500 230 2830 230 2230 230 2500
230 3000 70530
70 193070 530
70 2930 70 1800 90 3520 230 2810 90 160 2460 2250 90 160
230 3600 70 93070930 70 3530 70 1000 800 90 3520 70 2990 230
240 760 230 6000 70730 70 600
1100600
250 7320 230
2000 110 9190 90
13200
450
3340
920
3340
40
3460
1200
450
110
340
230
3000
110
920
110
3000
230
40
230
3000
230
9702
30
340110
3790
920
350
6490
9009
0210
450
230
3000
70
980
90
3000
230
40
230
3000
230
1200
230
1900
70
1030
70
980
90
1530
701400
230
40
230
2360
70
700
70 1000
230
230
2400
70
530
70 9
80
90
3000
230
40
230 1000
70
3130
230
850110
130
90x90 Timberposts
Feature TimberPergola
Beam & Bulkhead over
Beam & Bulkhead overElectric HWS
Electric HWS
See sheet 14 forpartywall detail
ubo
Pantry
ubo
FW
FW
FW
ROBE
ROBE
LINEN
GARAGE
GARAGE
BED 3 BED 2 BED 1 ALFRESCO
LIVINGDINING
KITCHEN
PORCH
PERGOLA PORCH
BED 1KITCHEN
LIVING ALFRESCO
LINEN
W.I.R
W.I.R
tap hwsMETERBOX
M
M
tap
taptap hws
CSD
CSD
250m
m Breakfast Bar
250m
mB/Bar
2x/vsl/dr
2x/vsl/dr
2x/vsl/dr
UNIT 1
UNIT 2
BROOM
CSD
Pantry
A/C
A/C
A/C
A/C
A/C
A/C
A/CA/C
METERBOX
C
12
C
12
A
12
A
12
B
12
B
12
FLOOR AREAS
UNIT 1LOWER LIVING AREA:GARAGE:ALFRESCO:PORCH:TOTAL:
UNIT 2LOWER LIVING AREA:GARAGE:ALFRESCO:PORCH:PERGOLA:TOTAL:
GRAND TOTAL:
PERIMETER:
101.84 sq.m22.82 sq.m9.39 sq.m2.19 sq.m
136.24 sq.m
62.90 sq.m23.59 sq.m11.65 sq.m1.91 sq.m5.38 sq.m
105.42 sq.m
241.66 sq.m26.01 sqs69.720LM
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be Clear* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be electric*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening
FLOOR PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
6 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
10 degree Colorbond custom orb roof sheeting + Sarking
Colorbond fascias,gutters & PVC downpipes
10 degree Colorbond custom orb roof sheeting + sarking
190x45 H3 roughheader treated Pine
Beam
140x45 H3 rough headertreated Pine Beam
90x90 LaminatedHWD Posts
Colorbond fascias,gutters & PVC downpipes
roof fall
roof fall
roof fall
roof fall
C
12
C
12
A
12
A
12
B
12
B
12
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be Clear* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be electric*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening
ROOF PLAN
SCALE 1:100
ELEVATIONS
4
3
2
1
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
7 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
2440
160
10 degree Colorbond custom orb roof sheeting + sarking
90x90 TimberPosts
Selected 'LINEA' Boardcladding with wall insulation
RenderedBrickwork
Powdercoated aluminiumwindows & SGDs
Painted FCSheeting
Colorbond fascias,gutters & PVC downpipes
FL FL
CL CL
inc 40 fascia
ELEVATION 1 1:100
2440
200
490490
10 degree Colorbond custom orb roof sheeting+ sarking
90x90 TimberPosts
Selected 'LINEA' Boardcladding with wall insulation
RenderedBrickwork
Powdercoated aluminiumwindows & SGDs
Painted FCSheeting
Colorbond fascias,gutters & PVC downpipes
FL FL
CL CL
inc 40 fascia inc 40 fascia
Upstand
ELEVATION 2 1:100
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be Clear* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be electric*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
8 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
2440
160
10 degree Colorbond custom orb roof sheeting + sarking
Selected 'LINEA' Boardcladding with wall insulation
RenderedBrickwork
Powdercoated aluminiumwindows & SGDs
Painted timberfeature pergola
90x90 TimberPosts
350x350Renderedcolumn
Colorbond fascias,gutters & PVC downpipes
350x350 Renderedcolumn
FL FL
CL CL
inc 40 fascia
ELEVATION 3 1:100
2440
200
Selected 'LINEA' Boardcladding with wall insulation
RenderedBrickwork
Powdercoated aluminiumwindows & SGDs
Colorbond fascias,gutters & PVC downpipes
10 degree Colorbond custom orb roof sheeting + sarking
Painted timber featurepergola
Selected 'LINEA'Board cladding
350x350Rendered column
FLFL
CLCL
Upstand
ELEVATION 4 1:100
NOTES:* Lift off hinges to WC door, as per BCA 3.8.3* Provide GPO & cold water provisions to DW space* ALL External and Internal doors & windows to bemeasured on site and confirmed by builder* Sarking to external walls* Insulation to ceiling (living only) R2.5 batts* All windows & SGD to be Clear* Mechanically vent rooms without natural ventilation* All shower roses to be AAA rated* Maximum water supply pressure not to exceed 500kpaat any outlet* Hot water system shall be electric*Water supply outlets to have WELs rating* Toilet cisterns to have dual flush. 6/3 Litre* ALL handrails to be 1000mm above finished floor level* Bedroom windows w. 2m fall height from FL to groundbelow must comply with N.C.C 3.9.2.5. To be fitted withnon-removable screens or restricted to 125mm opening
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
9 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
820
820820
820 720 820720
820
820
820
520
820 820
820
820
12-15asw09-06asw
18-06adh
18-06adh
21-24 panelift door
12-24asw
21-24SD
21-24SD
06-18asw
09-06asw
21-24 panelift door
12-15asw
09-12asw
21-24SD
D.P D.P D.PD.P
D.P
D.P
D.P
Electric HWS
Electric HWSVent to Eaves
Vent to Eaves
Vent to Eaves
Vent to EavesVent to Eaves
Vent to Eaves
spp for remotecontrolled paneliftdoor two handsets
supplied
tap hwsMETERBOX
M
M
tap
taptap hws
TV
TV
spp for remotecontrolled paneliftdoor two handsets
supplied
spp forHP
spp for DW
spp for REF
spp forR'HOOD
spp forHP
spp for DW
spp forREF
spp forR'HOOD
A/C
A/C
A/C
A/C
A/C
A/C
Round Fluro
RoundFluro Round
Fluro
RoundFluro
A/CA/C
METERBOX
ELECTRICAL PLAN
SCALE 1:100CLIENT WITH ELECTRICIANCONFIRMED ON SITE BYELECTRICAL LAYOUT TO BE
P.
ELECTRICAL LEGEND
TV
CEILING FAN LIGHT
PHONE OUTLET
2 GLOBE FAN, HEAT, LIGHT
METER BOX
SINGLE GPO'S - 1050 OFF FLOOR
SINGLE GPO'S - 300 OFF FLOOR
DOUBLE GPO'S - 300 OFF FLOOR
TV ANTENNA POINT
EXHAUST FAN
FLUORESCENT LIGHT
PHONE OUTLET-300 OFF FLOOR
CEILING FAN
DOWN LIGHT
WALL LIGHT
SMOKE DETECTOR
FLOOD LIGHT
PENCIL SPOT
SPECIAL LIGHT
SWITCH POINTS @ 1350 OFF FLOOR
DOUBLE GPO'S - 1050 OFF FLOOR
CEILING LIGHT (BATTEN HOLD)
NOTES:
* ALL external power points to be weather-proof
** ALL ELECTRICAL POINTS T.B.C ON SITE BYCLIENT AND ELECTRICIAN **
FP.FLUORESCENT PENCIL SPOT
PROVIDE 80% min. ENERGY EFFICIENT LIGHTING
AS PER QUEENSLAND DEVELOPMENT CODE GUIDELINES
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
10 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
TRUSSES & LINTELS AS PER
TRUSS MANUFACTURERS
SPECIFICATIONS
TB
P1
0.6
TBP1 0.9
TBP1 0.9
TBP1 0.9TBP1 0.9
TBP1 0.9
TBP1 0.9
TBP1 0.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1 0
.9
TB
P1
0.6
TB
P1
0.9
TB
P1 0
.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.6
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1 0
.9
TB
P1
0.9
TB
P1
0.9
TB
P1 0
.9T
BP
1 0
.9
TB
P1
0.9
TB
P1
0.9
TB
P1 0
.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9
TB
P1
0.9 T
BP
1 0
.9
TB
P1
0.9
TB
P1 0
.9
TB
P1 0
.6
TBP1 0.9
TBP1 0.9TBP1 0.9
TBP1 0.9
Bracing Panels on party wall tobe placeed on outside of wall, do
not pack wallBracing Panels on party wallto be placeed on outside of
wall, do not pack wall
M
M
*
*
*
*
**
*
*
*
*
*
*
****
***
2/190x35 MGP12
2/190x35 MGP12
140x35
MGP12
140x35
MGP12
140x35
MGP12
140x35
MGP12
190x35 MGP12
2/140x35 MGP12 (Continuous)195x65
Hynebeam 17C
195x65Hynebeam 17C
2/140x35 MGP12190x35MGP12
140x35MGP12
195x65 Hynebeam 17C
140x35MGP12
2/190x35 MGP12
195x65 Hynebeam 17C
230x65 Hynebeam 17C
140x35MGP12
2/140x35MGP12
W B1
W B1
W B 1
W B 1
W B 1
W B 1
W B1
W B1
195x65 Hynebeam 17C
2/190x35 MGP12
2/190x35 MGP12
BRACING PLAN
SCALE 1:100
TIMBER FRAME & TRUSSES2440mm PITCHING HEIGHT10 Deg ROOF PITCHCOLORBOND SHEET ROOF
NOTE:* Provide three studs under each end ofTG's, provide four studs under each end ofGT's.* Hardwood top plate under GT's, TG's andunder loadbearing points.* Edge nailng of ply brace to be at 50mmcentres, no tiedown rods are required.* M12 rods to brick piers, typical, cavityfilled.* ALL 600mm TB4B panels to have an M12rod to each end.
C2/SRNOTES:* Engineer to specify ALL roof strapping and any
additional bracing that may be reqd.
* Brickwork & galv. lintel over external openings 3000mm
wide or less, rendered harditex over openings greater
ALL LINTELS UNDER POINT LOADS TO BE CONFIRMED BY TRUSS MANUFACTURER / ENGINEER
BRACING SCHEDULE
TBP1/ 0.9 INDICATES A 0.9M LONG TIMBER BRACING WALLSHEETED ON ONE SIDE WITH STRUCTURAL "PLYWOOD" (OR EQUIV.)INSTALLED STRICTLY IN ACCORDANCE WITH AS 1684.3-TABLE 8.18 (h) TO DEVELOP 6.4kN /M RACKING RESTRAINT.
"." INDICATES REQUIRED LOCATION OF 1/M12HOLD DOWN ROD CONNECTING TOP PLATE TO SLAB.
" * "INDICATES REQUIRED LOCATION OF 1/M16
HOLD DOWN ROD CONNECTING TOP PLATE TO SLAB
WB1- 1/30 x 0.8 GI STRAP WIND BRACE TO UNDERSIDE TO TRUSSES 2- NAILS TO EACH TRUSS, 6- NAILS (LOOPED) EACH END.
TBP2/ 2.7 INDICATES A 1.8M LONG TIMBER BRACING WALLSHEETED ON ONE SIDE WITH STRUCTURAL "PLYWOOD" (OR EQUIV.)INSTALLED STRICTLY IN ACCORDANCE WITH AS 1684.3-TABLE 8.18 (i) TO DEVELOP 8.7kN /M RACKING RESTRAINT.
TBP1/ 0.6 INDICATES A 0.6M LONG TIMBER BRACING WALLSHEETED ON ONE SIDE WITH STRUCTURAL "PLYWOOD" (OR EQUIV.)INSTALLED STRICTLY IN ACCORDANCE WITH AS 1684.3-TABLE 8.18 (h) TO DEVELOP 6.4kN /M RACKING RESTRAINT.
TBP1/ 1.8 INDICATES A 1.8M LONG TIMBER BRACING WALLSHEETED ON ONE SIDE WITH STRUCTURAL "PLYWOOD" (OR EQUIV.)INSTALLED STRICTLY IN ACCORDANCE WITH AS 1684.3-TABLE 8.18 (h) (METHOD A) TO DEVELOP 6.4kN /M RACKING RESTRAINT.FIXING OF BOTTOM PLATE TO FLOOR FRAME OR SLAB: M12 RODS,PLUS A 13kN CAPACITY CONNECTION AT MAX. 1200MM CENTRES
" "INDICATES REQUIRED LOCATION OF A 13kN CAPACITY
CONNECTION, CONNECTING BOTTOM PLATE TO SLAB
ALL COMPONENTS AND CONNECTIONS INCLUDING FRAMING, TIE - DOWN ANDBRACING TO BE OF A STANDARD, NO LESS THAN C2 WIND CLASSIFICATION
AND COMPLY WITH AS1684.3 - 2010 AND JD5 JOINT GROUP FOR ALL PINE
TIMBER NOT MGP12 OR ABOVE. ALL FRAMING TO BE DESIGNED TO SUITSPECIFIED TIE-DOWN
LOOPED STRAP AROUND LINTEL/TOP PLATE TO BE
INSTALLED WITHIN 100MM OF EVERY TRUSS WHERE
TRUSS IS SITUATED ABOVE OPENING
BRACING REQUIRED
BRACING PROVIDED
BRACING REQUIRED
111.70 kN
115.20 kN
37.20 kN
BRACING PROVIDED 40.32 kN
UNIT 1
BRACING REQUIRED
BRACING PROVIDED
BRACING REQUIRED
106.10 kN
72.96 kN
21.05 kN
BRACING PROVIDED 23.04 kN
UNIT 2
UNIT 2
UNIT 1
BRACING IN THISDIRECTION TO BECOMPLETED BY
ENGINEER FROMLACK OF WALL SPACE
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
11 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
2 4 0 4 4 DI A
G O N A L DI M
E N S I ON
820
900
1000 910
900
710
1000 1900 1000
900
2460
900 2580
1235
410
2745
5040
23160
9390 2020 3730 3060 2460 2500
2810 90 160 2460 2250 90 160
13200
450
3340
920
6840
1200
450
3340
1270
6490
900
90
210
3340
920
350
2000
1200
450
23160
1000 6070 5080 4790 3720 2500
350 650 901533
901533
901143
3501240 13590 2250 90 160
13200
450
3070
4570
4660
450
160
90
2820
4570
160
90
4160
90
160
450
850
350
Slab & footing design toengineers detail
Selected termite protectionsystem to underside of slab,perimeter & penetrations, inaccordance with AS 3660.1
tub
tub
sink
basin wc
shower
sink
basinwc
shower
shower
basinwc
fw
fw
fw
PADRL - t.b.cFFLRL - t.b.c
(all levels t.b.c on site)
100mmstepdown
100mmstepdown
100mmstepdown
SLAB PLAN
SCALE 1:100
NOTES:* Slab and Footings as per engineers designs* Provide Termite Protection as per AS 3660* ALL floor levels t.b.c on site* ALL floor joist to be specified by engineer
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
12 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
2440
200
49049010 degree Colorbond
custom orb roof sheeting +sarking
Selected 'LINEA' Boardcladding with wall insulation
RenderedBrickwork
Slab & footings as perengineers design
10 degree Colorbond custom orb roof sheeting +sarking
Party wall to extend to underside of roofwith mineral fibre or other fire resistingmaterial packed under sheeting Seesheet 14 for partywall detail
Plasterboard lining towalls & ceiling
Colorbond fascias,gutters & PVC downpipes
SECTION 1:100
5
FL
CL
FL
CL
C
inc 40 fasciainc 40 fascia
Binders @ 3000 CtrsBinders @ 3000 Ctrs
BED 1 DINING BED 1
UNIT 1 UNIT 2
Upstand
2440
16010 degree Colorbond custom orb roof sheeting + sarking
350x350Renderedcolumn
Slab & Footings asper engineers design
Powdercoated aluminiumwindows & SGDs
90x90 TimberPosts
Plasterboard lining towalls & ceiling
Colorbond fascias,gutters & PVC downpipes
SECTION 1:100
5
FL
CL
FL
CL
B
inc 40 fascia
GARAGEBED 1KITCHENLIVINGALFRESCOUNIT 2
BATH
100mmstepdown
Binders @ 3000 Ctrs
2440
200 16010 degree Colorbond custom orb roof sheeting + sarking
90x90 TimberPostsRendered
Brickwork
Powdercoated aluminiumwindows & SGDs
Slab & Footings as perengineers design
Plasterboard lining towalls & ceiling
Colorbond fascias,gutters & PVC downpipes
SECTION 1:100
5
FL
CL
FL
CL
A
inc 40 fascia inc 40 fascia
BED 3 BED 2 BED 1 ALFRESCOBATH ENSUNIT 1
100mmstepdown
Binders @ 3000 Ctrs
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
13 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
2440
1800
300
340
2100
340
900
600
940
900
750
450
340930 600
Corner doorFL
CL
FL
CL
REF.Space Only
Rangehood
Cooktop
UBO
Pantry
KITCHEN ELEVATION 1 - UNIT 2 1:502440
2100
340
900
600
600
340
1000 600
Corner DoorFL
CL
FL
CL
REF. SpaceOnly Pantry
KITCHEN ELEVATION 1 - UNIT 1 1:50
2440
900
600
600
340
900
750
450
340
FL
CL
FL
CL
Rangehood
Cooktop
UBO
KITCHEN ELEVATION 2 - UNIT 1 1:50
2440
900
600
600
340
Corner DoorFL
CL
FL
CL
Sink
DW SpaceOnly
KITCHEN ELEVATION 3 - UNIT 1 1:50
2440
900
600
600
340
Corner doorFL
CL
FL
CL
Sink
KITCHEN ELEVATION 2 - UNIT 2 1:50
2440
900
1540
FL
CL
FL
CL
DW SpaceOnly
KITCHEN ELEVATION 3 - UNIT 2 1:50
450mm WIDE UNLESS OTHERWISE NOTED.
TO BE 300mm WIDE & KITCHEN DRAWERS TO BE
CABINETMAKERS DISCRETION, VANITY DRAWER
* DOOR SWINGS & CUPB'DS CONFIGURATIONS TO
NOTE:
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
14 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
Stud Wall
110 Brickwork
40mm Cavity
50mm Cavity
8mmExpansion joint
8mmExpansion joint
Stud Wall
110 Brickwork
40mm Cavity
50mm Cavity
End Party Wall Details 1:50
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
15 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
820
820
820
820 720 820720
820
820
820
520
820 820
820
820
12-15asw09-06asw
18-06adh
18-06adh
21-24 panelift door
12-24asw
21-24SD
21-24SD
06-18asw
09-06asw
21-24 panelift door
12-15asw
09-12asw
21-24SD
REF.
W.M.
PROV
W.M.
PROV
DW
PROV
REF. DW
PROV
D.P D.P D.PD.P
D.P
D.P
D.P
Electric HWS
Electric HWS
ubo
ubo
FW
FW
FW
tap hwsMETERBOX
M
M
tap
taptap hwsA/C
A/C
A/C
A/C
A/C
A/C
WET AREA TILES = 15.75Sq.m(incl. showers and under vanities)
EXTRERIOR TILES MAIN FLOOR TILES = 76.69Sq.m
CARPET = 48.72Sq.m
PLAIN CONCRETE
A/CA/C
METERBOX
FLOOR COVERINGS PLAN
SCALE 1:100
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
16 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
820
820
820
820 720 820720
820
820
820
520
820 820
820
820
12-15asw09-06asw
18-0
6adh
18-0
6adh
21-2
4 p
anelif
t doo
r
12-2
4asw
21-24SD
21-2
4SD
06-18asw
09-06asw
21-2
4 p
anelif
t doo
r
12-15asw
09-12asw
21-2
4SD
D.P D.P D.PD.P
D.P
D.P
D.P
278° 7
' 0"
19.0
35
188° 7' 0" 35
98° 7
' 0"
19.0
35
188° 7' 0" 35
600mm x1200mm Slab
600mm x1200mm Slab
600mm x1200mm Slab
600mm x 1200mmSlab
1600mm x2400mm Slab
1600mm x2400mm Slab
Grey Concrete todriveway from boundaryto gutter
600mm x600mm Slab
800mm x1400mm Slab
800mm x1400mm Slab
600mm x 600mm Slab
3000mm x 2000mm Slab
3000mm x 2000mm Slab
tap METERBOX
tap
taptap A/C
A/C
A/C
A/C
A/C
A/C
A/CA/C
METERBOX
FL
IN
TW
OO
D
ST
RE
ET
1200
600
1200
600
600 1200
600
2400
1600
1200
600
4755 5000 1000
1730
450
5000
510
6490
4480
1200
4755 5000 5480
2400
1600
1400
800
800
1400
600
600
3000
2000
3000
2000
0.72 m2
0.72 m2
3.84 m2
0.72 m2
40.47 m2
0.72 m2
3.84 m2
23.78 m2
0.36 m2
1.12 m2
1.12 m2
0.36 m2
6.00 m2 6.00 m2
Grey Concrete to driveway fromboundary to gutter
EXPOSED AGG -
53.99Sq.m
A/C SLAB
A/C SLAB
HWS / A/C SLAB
A/C SLAB
CLOTHES LINESLAB
CLOTHESLINE SLAB
DRIVEWAY &PERGOLA
GREY CONCRETE
23.78Sq.m
RUBBISH BIN SLAB
RUBBISH
BIN SLAB
HWS SLAB
SHEDSLAB
SHEDSLAB
EXTERNAL CONCRETE PLAN
SCALE 1:100
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
17 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
2440
500
500
450
400
400
2440
500
450
400
400
400
2440
1750
2440
900
2440
750
750
2440
2100
2440
2440
210
8501150
8501150
FL
CL
FL
CL
FL
CL
FL
CL
FL
CL
FL
CL
FL
CL
FL
CL
70x3570x3570x35
70x3570x3570x35
70x3570x3570x35
FL
CL
FL
CL
70x3570x3570x35
FL
CL
FL
CL
70x3570x3570x35
70x3570x3570x35
BROOM / LINEN SHELVINGDETAIL 1:50
ROBE SHELF DETAIL
1:50
TOILET ROLL HOLDER SOLID
BLOCKING DETAIL 1:50
TOWEL RAIL SOLID BLOCKING
DETAIL 1:50
DRYER SOLID BLOCKINGDETAIL 1:50
ROBE SHELF DETAIL
1:50
FL
CL
FL
CL
FL
CL
FL
CL
BALASTRADE INTERNAL &
ENTERNAL NOGGING DETAIL 1:50
STAIR HANDRAIL NOGGING
DETAIL 1:50
70x3570x3570x3570x35
70x3570x3570x35
70x3570x3570x3570x35
All Measurements to top
of shelf
All Measurements to top
of shelf
All Measurements
to top of shelf
Sheathed panels shallbe connected tosub-floor/slab
Horizontal butt jointspermitted. Provide nailfixed to nogging as shown
Indicates 30x2.8mm diagalv. Flat head nails(spacings as shown)or equivalentBRACING SHEET NTS
Fix bith ends of bracingwall with 1/M12botl & at 1200crs Max.
Bottom truss chord
2/No. 14 Type 17 Batten screwsthru 70x35 MGP10 shear blocksfit snug to nogging. typ.
Non load bearingwall
TRUSSES PARALLEL TO NON LOAD BRACING WALL
Gap to truss
2/30x 0.8mm G.I Strapswith 6/2.8mm dia nailseach end
Internal bracing wall
External wall
TYPICAL INTERNAL - EXTERNAL BRACING WALL FIXING1:20
1:20
Bracing wall
Bottom chord of truss
TRUSSES PERPENDICULAR TO NON LOAD BRACING WALL
70x35 MGP10 Blocking each sideof truss bottom chros with2/No.14 Type 17 batten screws totop plate. Fit blockingsnug to truss chord
1:20
WITNESS DATE
amendmentsdesign drawn by
date
scales
job number
of
Phone (07) 55 203 022Fax (07) 55 203 033PO Box 2845 Burleigh HeadsDC Qld 4220
ABN 73 097 995 616QLD 4219
BSA License No: 1129687Email: [email protected]
PLEASE READ CAREFULLY
IN THE INITAL AGREEMENT AND I UNDERSTAND CHANGES
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO
HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS
SUPERSEDE ALL OTHER PREVIOUS PLANS OR SKETCHES.
OWNER/S
Contractor to verify dimensions. Notify designers ofdiscrepancies. Failure to do
so shall void the designers responsibilities.
dimensions take preference.© Copyright reserved in part or whole. Written
THIS DESIGN IS THE EXCLUSIVE PROPERTY OF STUART OSMAN BUILDING DESIGNS
N.B ALL WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES RESPONSIBILITIES OF STUART OSMAN BUILDING DESIGNS FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING
BE WARNED: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, AND OR ANY VARIATION TO ANY PART OF THE DESIGN WILL VOID ANY
Address: 2/71 Township
Drive, West Burleigh,
sheet #
checked by
Top Plate
(TYP)
(TYP)
(TYP)
(TYP)
Note: Provide one (1) strap only for designated ' teco' bracing wall panels
Gap to truss
Gap to truss
Non load bearing bracingwall
120x35 nogging
Nailing plates or framinganchor (legs not bent) toeither end of nogging 2/No.14Type 17 batten screws either end
2/ No.14 Type 17 battenscrews thru 70x 35 MGP10shear blocks fit snug to nogging. typ.
TRUSSES PARALLEL TO NON BEARING WALL
Line of Prefabricated gangnail roof trussesat 600 crs Max. Fixed at top plate and or roof beamsin accordance with roof manufact. Specifications
Sheet roof by others
1/ 35x70 (MGP12) Common Stud Max. Height 2700Construct in accordance with AS 1684.3 c2Residential timber framed construction
Pitch to Arch Specification
35x70 (MGP12) Roof battens at 600crs. Fix with1/No. 14 Type 17 battern screw to rafters and or trusses.
2/ 45x70 (MGP12) (7500 RLW) Top plate rafters/ trussesmust be supported directly over studs within 105mm(1.5 times the thickness of the top plate),from the studs. All holds done rods to be positioned no more than100mm from face of truss (900 crs. MAX)
or
as n
om
inate
d
or
as n
om
inate
d
waffle pod slab as per engineers design
with exposed edge for visual inspection
@ max 1800 centresfrom top plate to lintel
to have looped strapWindows > 1800 wide
sarking to roof where applicable
or as nominated on plans
90mm cornice, paint finish as selected
timber architrave, as selected
aluminium framed window as selected
-
D1
GI partition bracket
manufacturers printed specificationsRoof trusses @ 600mm centres as per truss
FL
CL
flashing & weephole
brick on edge sill
4.5mm FC soffit lining, paint finish as selected
bottom platesDPC to underside of
per section 1.4 of the BCAflashing & weephole as
320
2120
2440
moisture barrier
50mm sand bed
600
metal fascia & gutter
T.B.C by engineer
brick veneer wall
Termi-mesh or similar to all slab
penetrations & perimeter
CV
THE LORD HOWE - MKIII METRO FACADE
5506
IGNITE HOMES
LOT 120 FLINTWOOD ST
RURAL VIEW A 10/04/14
18181:100 @ A3
******SO
STRESS
GRADE 450MM 600MM
STUD SPACING
F8
F11
F14
F27
7 9
76
4
4
6
4.5
PLYWOOD THICKNESS (MM)
TYPICAL CONNECTION DETAILS 1:20
1/35x70 (MGP12) To be fully supported
Line of slab and footing system
as detailed as before
Line of M12 hold down rod at location shown on plan.
(Position at all corners,100mm Max.
From last stud beside openings and within 100mm
Max. From all locations generally
from tp plate to stud.
C2 / SHEET / Brick Veneer
WALL CLADDING ASNOMINATED ON PLANS
Refer to architectural specification for all set-out dimension, finishings, flashings, waterproofings etc.
Phone (07) 55 203 022Fax (07) 55 203 033
PO Box 2845 Burleigh Heads DC Qld 4220Address: 2/71 Township Drive, West Burleigh, QLD 4219
ABN 73 097 995 616BSA License No: 1129687Email: [email protected]
© Copyright reserved in part or whole. Writtendimensions take preference.Contractor to verify dimensions.Notify designers of discrepancies.
Failure to do so shall voidthe designers responsibilities.
TH
IS D
ES
IGN
IS
TH
E E
XC
LU
SIV
E P
RO
PE
RT
Y O
F S
TU
AR
T O
SM
AN
BU
ILD
ING
DE
SIG
NS
N.B
ALL
WR
ITT
EN
DIM
EN
SIO
NS
TA
KE
PR
EC
ED
EN
CE
OV
ER
SC
ALE
D S
IZE
S
BE
WA
RN
ED
: S
UB
ST
ITU
TIO
N O
F A
NY
ST
RU
CT
UR
AL M
EM
BE
RS
, A
ND
OR
AN
Y V
AR
IAT
ION
TO
AN
Y P
AR
T O
F T
HE
DE
SIG
N W
ILL V
OID
AN
Y
RE
SP
ON
SIB
ILIT
IES
OF
ST
UA
RT
OS
MA
N B
UIL
DIN
G D
ES
IGN
S F
OR
TH
E S
TR
UC
TU
RA
L IN
TE
GR
ITY
AN
D P
ER
FO
RM
AN
CE
OF
TH
E B
UIL
DIN
G
PROJECT
JOB NUMBER
BUILDER
DRAWN BY CHECKED BY
DESIGN
DATE
SCALES AMENDMENTS
SHEET NUMBERof
CHARTERED
MEMBER OF
PROPOSED DUPLEX
LOT 120
FLINTWOOD STRURAL VIEW
5506
CV
A 10/04/14
B-170414
C-280414
D-160514
SO
THE LORD HOWE - MKIII
METRO FACADE
1:100 @ A3
19 19
building designersassociation of
queensland inc.
IGNITE HOMES PTY LTDA.B.N 52128355466QBCC - 1173465PO BOX 1159
TOOMBUL QLD 401207 3630 2924
278° 7
' 0"
19.0
35
188° 7' 0" 35
98° 7
' 0"
19.0
35
188° 7' 0" 35
Grey concreteto council verge
Garden shed
2.0x3.0m
Garden shed
2.0x3.0m
Garden bed with shade tree shrubs and ground cover,100mm organic mulch over topsoil
Letterboxes
Private Open Space
Private Open Space1800mm high timber fencing
tap
tap
taptap
FL
IN
TW
OO
D
ST
RE
ET
BUILDING ENVELOPE
BUILDING ENVELOPE
- turf over topsoil
- garden bed
- exposed agg. concrete
- grey concrete
- 1800mm treated timber fencing
SYMBOL BOTANICAL NAME
PLANTING SCHEDULE
CORDYLINE
CROTON
STRELITZIA
QUANTITY
4
4
4140mm
140mm
140mm
POT SIZEmm
TUCKEROO 445 litre
TUCKEROO CORDYLINE CROTON STRELITZIA
LANDSCAPING PLAN
SCALE 1:200 SHEET 19 OF 19 JOB NUMBER - 5506