8
3G measurement report events SHALABH SAXENA

52823719-3G-Measurement-Report-Events.ppt

Embed Size (px)

Citation preview

Page 1: 52823719-3G-Measurement-Report-Events.ppt

3G measurement report events

SHALABH SAXENA

Page 2: 52823719-3G-Measurement-Report-Events.ppt

OVERVIEW

This document covers event details for following measurement reporting criteria:

1. Intra Frequency measurement reporting

2. Inter Frequency measurement reporting

3. IRAT measurement reporting

4. Quality measurement reporting

5. UE internal measurement reporting criteria

6. Traffic volume measurement reporting

7. UE internal measurement reporting criteria

8. Events 7x

Source:3GPP TS 25.331 v3.a.0

Page 3: 52823719-3G-Measurement-Report-Events.ppt

Ericsson AB 2009 06-12-20093

Intra-frequency measurement reporting criteria

The triggering of the event-triggered reporting for an intra-frequency measurement. All

events concerning intra-frequency measurements are labeled 1x where x is a, b, c….

Event 1a: A Primary CPICH enters the Reporting Range (FDD only).

Event 1b: A Primary CPICH leaves the Reporting Range (FDD only).

Event 1c: A Non-active Primary CPICH becomes better than an active Primary CPICH

(FDD only).

Event 1d: Change of best cell (FDD only).

Event 1e: A Primary CPICH becomes better than an absolute threshold (FDD only).

Event 1f: A Primary CPICH becomes worse than an absolute threshold (FDD only).

Event 1g: Change of best cell in TDD.

Event 1h: Timeslot ISCP below a certain threshold (TDD only).

Event 1i: Timeslot ISCP above a certain threshold (TDD only).

Page 4: 52823719-3G-Measurement-Report-Events.ppt

Ericsson AB 2009 06-12-20094

InTER-frequency measurement reporting criteria

The triggering of the event-triggered reporting for an inter-frequency measurements. All

events concerning inter-frequency measurements are labelled 2x where x is a,b,c, ...

Event 2a: Change of best frequency.

Event 2b: The estimated quality of the currently used frequency is below a certain

threshold and the estimated quality of a non-used frequency is above a certain threshold.

Event 2c: The estimated quality of a non-used frequency is above a certain threshold.

Event 2d: The estimated quality of the currently used frequency is below a certain

threshold.

Event 2e: The estimated quality of a non-used frequency is below a certain threshold.

Event 2f: The estimated quality of the currently used frequency is above a certain

threshold.

Page 5: 52823719-3G-Measurement-Report-Events.ppt

Ericsson AB 2009 06-12-20095

IRAT measurement reporting criteria

The triggering of the event-triggered reporting for an inter-RAT measurement. All events

concerning inter-RAT measurements are labelled 3x where x is a,b,c, ...

Event 3a: The estimated quality of the currently used UTRAN frequency is below a

certain threshold and the estimated quality of the other system is above a certain

threshold.

Event 3b: The estimated quality of other system is below a certain threshold.

Event 3c: The estimated quality of other system is above a certain threshold.

Event 3d: Change of best cell in other system.

QUALITY measurement reporting criteria

Event 5a: Number of bad CRCs on a certain transport channel exceeds a threshold.

Page 6: 52823719-3G-Measurement-Report-Events.ppt

Ericsson AB 2009 06-12-20096

UE internal measurement reporting criteria

The triggering of the event-triggered reporting for a UE internal measurement. All events

concerning UE internal measurements are labelled 6x where x is a, b, c…. In TDD, the

events 6a - 6d are measured and reported on timeslot basis.

Event 6a: The UE Transmitted Power becomes larger than an absolute threshold

Event 6b: The UE Transmitted Power becomes less than an absolute threshold

Event 6c: The UE Transmitted Power reaches its minimum value

Event 6d: The UE Transmitted Power reaches its maximum value

Event 6e: The UE RSSI reaches the UEs dynamic receiver range

Event 6f: The UE Rx-Tx time difference for a RL included in the active set becomes

larger than an absolute threshold

Event 6g: The UE Rx-Tx time difference for a RL included in the active set becomes less

than an absolute threshold

Page 7: 52823719-3G-Measurement-Report-Events.ppt

Ericsson AB 2009 06-12-20097

Traffic volume measurement reporting criteria

Contains the measurement reporting criteria information for a traffic volume

measurement.

Event 4a: Transport Channel Traffic Volume [15] exceeds an absolute threshold.

Event 4b: Transport Channel Traffic Volume [15] becomes smaller than an absolute

threshold.

Event 7a: The UE position changes more than an absolute threshold

Event 7b: SFN-SFN measurement changes more than an absolute threshold

Event 7c: GPS time and SFN time have drifted apart more than an absolute threshold

Events 7X

Page 8: 52823719-3G-Measurement-Report-Events.ppt