Microwave Maintenance Experience share
Microwave Maintenance Experience shareBy : Tu Qiang15 Dec 2009 2006, ZTE Corporation. All rights reserved.RX level lower
IF cable connector problem
RF cable or HYB problem
E1 channel alarm
ODU faulty
IDU faultyOrdinary Problem : 2006, ZTE Corporation. All rights reserved.All of these problems can use PNMTj and Multimeter check the alarm; voltage and resistance to confirm.Ordinary Problem : 2006, ZTE Corporation. All rights reserved.For easily to know how to solve the Microwave problem, this document will according to the parameter and alarm find the problem, and then give the solution.Parameter and Alarm : 2006, ZTE Corporation. All rights reserved.Parameter and Alarm :1: Metering
2006, ZTE Corporation. All rights reserved.Parameter and Alarm :1: Metering
The parameter of metering is very important and from the parameter can know link work normal or not.
TX Power
RX Level
ODU Power Supply
2006, ZTE Corporation. All rights reserved.1: Metering1-1: TX Power
ODU TX PowerConfiguration: 1+0
ODU TX Power = TX Power Metering + |MTPC TX Power| (TX Power Metering is the red square; MTPC TX Power in the link summary can find the value)
Normal: +20 dBm