DishDrawer® Installation instructions 2 3 PRODUCT DIMENSIONS CABINETRY DIMENSIONS PARTS SUPPLIED Clamp (1) Wire clip (2) Phillips 16 mm screws (9) Drain hose support (1) Moisture protection tape (1) (to prevent moisture damage) Drain hose joiner (1) Top mounting brackets (2) OPTIONAL ” to ” BSP inlet hose adaptor (1) OPTIONAL Prefinished toekick (1) white or black Rubber washer for inlet hose (1) Hexagonal socket (2) (long & short) 4 DD60DDFHX6 & DD60DHI6 models SAFETY AND WARNINGS 1 O B C E D F J G H N I Installation diagrams for illustration purposes only K L M A N G C I Product dimensions (mm) Prefinished Flat door DD60DD- FHX6 Integrated DD60DDHI6 A overall height* of product 819.5- 879.5 819.5- 879.5 B overall width of product 599 599 C overall depth of product (excl. curvature/handle) 570 570 D depth of drawer (open) (excl. curvature/handle) 538 538 E height* of chassis 809 809 F height range of levelling feet 60 60 G depth of chassis (incl. trimseal) 552 552 H depth of drawer front panel (excl. curvature/handle) 18 18 I depth of curvature or handle 41 n/a J depth of toekick 50 - 65 67 - 127** K height of upper drawer front 398 398 min L height of lower drawer front 311.5 311.5 min M height of toekick panel (adjustable) 70 - 120 70 - 120 N height of installation bracket slots (on top of chassis) 2 2 O height of drawer fronts 717.5 717.5 min * Chassis heights include bracket slots ** less the Toekick Panel thickness (Minimum Panel thickness using the supplied screws is 9 mm). Note: for Prefinished Flat door models, height from top of handle to top of drawer - 64 mm. Cabinetry dimensions (mm) Prefinished Flat door DD60DD- FHX6 Integrated DD60DDHI6 A inside height of cavity 820- 882.5 820- 882.5 B inside width of cavity 600 600 C inside depth of cavity (inside) 580 580 D height of adjacent cabinetry 720 min. 720 E height of toekick space 100 - 160 100 - 160 Minimum clearances (mm) E l e c t r o n i c C o n t r o l l e r 6 H a l l s e n s o r ` F i l l v a l v e N P W a s h / D r a i n m o t o r L i d m o t o r s H e a t e r P l a t e C h a s s i s P C B E T h e r m i s t o r P o w e r / H e a t e r M o t o r C h a s s i s 1 / 2 1 1 1 7 M M 1 1 7 1 8 / 9 3 / 4 2 L o w e r R 2 . 5 P r o R 2 . 5 R 2 . 5 R a s t 5 / W e c o s c r e w t e r m i n a l R 2 . 5 C r i m p e d c o n n e c t i o n s P r o t e c t i v e s h e a t h F l o o d s e n s o r D o o r E a r t h E a r t h R F I E a r t h C h a s s i s E a r t h D r o p p e r R 2 . 5 P r o 4 4 6 5 6 B a d g e i s o l a t o r R i n s e a i d p u m p D e t e r g e n t d i v e r t e r R i n s e a i d L E D D i s p e n s e r F a n / L E D 2 / 3 9 S o f t e n e r 1 1 1 1 1 5 / 6 1 / 2 4 / 5 C o m m s 1 / 2 8 / 9 S a l t S e n s o r S a l t l o w L E D B r i n e P u m p S o f t e n e r b y p a s s v a l v e R 2 . 5 R 2 . 5 R 2 . 5 R 2 . 5 R 2 . 5 R 2 . 5 R 2 . 5 M + D r y i n g f a n R 2 . 5 R 2 . 5 4 3 / 4 1 R 2 . 5 6 5 / 6 1 R 2 . 5 T h e r m a l f u s e H e a t e r L N L s w N s w 3 R 2 . 5 1 5 1 R 2 . 5 P r o 5 R 2 . 5 1 1 2 / 3 P C B L C D / B a d g e 1 2 / 3 1 . 5 m A + - 0 . 8 2 A a c 0 . 8 2 A a c 0 . 8 2 A a c 0 . 8 2 A a c 6 . 0 6 A a c 6 . 0 6 A a c 1 . 5 m A 6 . 0 6 A a c P 1 0 1 P 6 0 1 P 2 0 5 2 . 2 m A a c 0 . 5 m A a c 5 0 m A d c 2 . 2 m A a c 5 0 m A d c 5 3 0 m A d c 5 3 0 m A d c 5 3 0 m A d c 5 3 0 m A d c 3 4 0 m A d c 3 4 0 m A d c 5 2 9 8 5 4 5 2 8 0 4 0 5 2 9 6 8 3 L C D M o d u l e 6 E C O L C D 1 5 / 6 N o n - i s o l a t e d B a d g e B a d g e 5 1 / 2 6 5 / 6 5 2 2 6 9 6 K e y 4 T u r b . s e n s . 3 / 4 C o n n e c t o r f u n c t i o n N o . o f w a y s P o s i t i o n o f c o d i n g r i b P i n 1 1 C o n n e c t o r t y p e R 2 . 5 S t o c k o R A S T 2 . 5 e d g e c o n n e c t o r R 2 . 5 P r o S t o c k o R A S T 2 . 5 P r o e d g e c o n n e c t o r R A S T 5 S t o c k o R a s t 5 c o n n e c t o r X A J S T X A t y p e i n l i n e c o n n e c t o r 0 . 7 5 m m 2 0 . 3 5 m m 2 W i r e t y p e L C D M o d u l e B r e e L C D 1 5 6 5 / 6 1 / 2 5 2 9 8 5 4 6 5 / 6 3 R 2 . 5 5 4 3 4 R 2 . 5 P r o L N L s w N s w L o w e r 5 2 2 5 3 6 U p p e r 5 2 2 5 3 7 U p p e r U p p e r c o n t r o l l e r c o n n e c t o r p i n n u m b e r s ( D i f f e r s f r o m l o w e r ) 6 4 / 5 5 2 6 7 5 4 I n t e g r a t e d B a d g e 8 1 6 4 / 5 5 2 8 4 0 3 D C S I n t e g r a t e d B a d g e B a d g e 8 1 5 2 7 6 0 6 J S T J S T 5 2 6 2 6 3 5 2 2 0 0 6 5 2 9 8 6 7 2.5 mm 2.5 mm A B C D E Installation diagrams for illustration purposes only 13 mm If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hoses by 3.6 m. The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our local website listed at the end of this document. CAVITY PREPARATION WIRING DIAGRAM 5 6 Important! SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our local website listed at the end of this document or contact your local Fisher & Paykel dealer. CN WARNING! Electrical shock hazard Before installing the DishDrawer®, remove the house fuse or open the circuit breaker. This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances. WARNING- Improper connection of the equipment- earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly earthed. Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box. Failure to follow this advice may result in electrical shock or death. WARNING! Cut hazard Take care - panel edges are sharp. Failure to use caution could result in injury or cuts. Important safety instructions! Installation of this DishDrawer® requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the DishDrawer® installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the DishDrawer®. This DishDrawer® is manufactured for indoor use only. Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required. The switched power outlet must be outside the DishDrawer® cavity, so that it is accessible after installation. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord. If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage. Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not be reused. Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims. If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product. These marks indicate mounting bracket screw locations Preferred position. If adequate clearance, services hole can be higher to clear toekick space. If hole is higher, ensure drain hoses are routed straight into the waste connection. + * Left hand side Right hand side Max. distance of hoses and cord from chassis edge Left hand side Right hand side Drain hose 2000 mm 1800 mm Inlet hose 1650 mm 1250 mm Power cord (excl. plug) 1650 mm 1650 mm Water Connection Recommended COLD (Maximum 60°C). “ BSP (GB20) to suit flat washer. Water Pressure Max Min 1 MPa (145 psi) 0.1 MPa (14.5 psi) Note: Services can be located either side of DishDrawer®. 10 mm max. 450 mm 220-240 VAC min. 9 A Moisture protection tape must be applied. min. ø60 mm * * min. 200 mm Water supply

Ø50mm services hole Important safety instructions! 5 ......PCB LCD / Badge 1 2 / 3 1.5mA +-0.82Aac 0. A a c 0.82Aac. 8 2 a 6.0 Aac 6.06Aac 1.5mA 2 5P 10 P601 2. 2 m A a c 0. 5 5 0

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Ø50mm services hole Important safety instructions! 5 ......PCB LCD / Badge 1 2 / 3 1.5mA +-0.82Aac 0. A a c 0.82Aac. 8 2 a 6.0 Aac 6.06Aac 1.5mA 2 5P 10 P601 2. 2 m A a c 0. 5 5 0

DishDrawer®Installation instructions

2 3PRODUCT DIMENSIONS CABINETRY DIMENSIONS

PARTS SUPPLIED

Clamp (1)Wire clip (2) Phillips 16 mm screws (9)

Drain hose support (1)

Moisture protection tape (1)(to prevent moisture damage)

Drain hose joiner (1)

Top mountingbrackets (2)OPTIONAL

3/4” to 1/2” BSP inlet hose adaptor (1)OPTIONAL

Prefinished toekick (1)white or black

Rubber washer for inlet hose (1)

Hexagonalsocket (2)(long & short)

4

DD60DDFHX6 & DD60DHI6 models

SAFETY AND WARNINGS1

O

BC

E

D

F

J

G

H

NI

Installation diagrams for illustration purposes only

K

L

M

ANG

C

I

Product dimensions (mm)

PrefinishedFlat doorD

D60D

D-

FHX6

IntegratedD

D60D

DH

I6

A overall height* of product 819.5- 879.5 819.5- 879.5

b overall width of product 599 599

c overall depth of product (excl. curvature/handle) 570 570

D depth of drawer (open) (excl. curvature/handle) 538 538

e height* of chassis 809 809

F height range of levelling feet 60 60

G depth of chassis (incl. trimseal) 552 552

H depth of drawer front panel (excl. curvature/handle) 18 18

I depth of curvature or handle 41 n/a

J depth of toekick 50 - 65 67 - 127**

K height of upper drawer front 398 398 min

L height of lower drawer front 311.5 311.5 min

M height of toekick panel (adjustable) 70 - 120 70 - 120

N height of installation bracket slots (on top of chassis) 2 2

O height of drawer fronts 717.5 717.5 min

* chassis heights include bracket slots

** less the Toekick Panel thickness (Minimum Panel thickness using the supplied screws is 9 mm). Note: for Prefinished Flat door models, height from top of handle to top of drawer - 64 mm.

cabinetry dimensions (mm)

PrefinishedFlat doorD

D60D

D-

FHX6

IntegratedD

D60D

DH

I6

A inside height of cavity 820- 882.5 820- 882.5

b inside width of cavity 600 600

c inside depth of cavity (inside) 580 580

D height of adjacent cabinetry 720 min. 720

e height of toekick space 100 - 160 100 - 160

Minimum clearances (mm)

Electronic Controller

6

Hall sensor

`

Fill valve

N

P

Wash / Drain motor

Lid motors

Heater Plate

Chassis PCB

E

Thermistor

Power / HeaterMotor Chassis

1/2

1 1 1

7

MM

11 7

1

8/9

3/4

2

Lower

R2.5 ProR2.5 R2.5

Rast 5/Weco screw terminal

R2.5

Crimped connections

Protective sheath

Flood sensor

Doo

r Ear

thE

arth

RFI Earth

Chassis Earth

Dro

pper

R2.5 Pro

4

4

6

5

6

Badge isolator

Rinse aid pump

Detergent diverter Rinse aid LED

Dispenser

Fan/LED

2/3

9 Softener

1

1

1

1

1

5/61/2

4/5

Comms

1/2

8/9

Salt

Sensor

Salt low LEDBrine Pump

Softener bypass valve

R2.5

R2.5

R2.5

R2.5

R2.5

R2.5

R2.5

M+

Drying fan

R2.5

R2.5

4

3/4

1

R2.56

5/6

1

R2.5

Thermal fuse

Heater

L NLsw

Nsw

3R2.5

1

5

1

R2.5 Pro

5R2.5

1

1

2/3

PCB

LCD / Badge

1

2/3

1.5mA+-

0.82Aac

0.82

Aac

0.82Aac

0.82

Aac 6.06Aac

6.06Aac

1.5mA

6.06Aac

P101 P601P205

2.2m

Aac

0.5m

Aac

50m

Adc

2.2m

Aac

50m

Adc

530m

Adc

530m

Adc

530m

Adc

530m

Adc

340m

Adc

340m

Adc

529854

528040

5296

83

LCD

Mod

ule

6

ECOLCD

1

5/6

Non-isolatedBadge B

adge

51/2

65/6

522696

Key

4Turb. sens.

3/4

Connector function

No. of ways

Position of coding rib

Pin 11

Connector type

R2.5 Stocko RAST 2.5 edge connectorR2.5 Pro Stocko RAST 2.5 Pro edge connectorRAST 5 Stocko Rast 5 connectorXA JST XA type in line connector

0.75mm20.35mm2

Wire type LCD

Mod

ule

BreeLCD

1

5

65/6

1/2

529854

65/6

3R2.5

543

4R2.5 Pro

L

N

Lsw

Nsw

Low

er 5

2253

6U

pper

522

537

Upper

Upper controller connector pin numbers

(Differs from lower)

6

4/5

526754

Inte

grat

ed

Bad

geB

adge

8

1

6

4/5

528403

DC

S In

tegr

ated

B

adge

Bad

ge

8

1 527606

JST

JST

526263

522006

529867

2.5 mm

2.5 mm

A

B

C

D

E

Installation diagrams for illustration purposes only

13 mm

If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hoses by 3.6 m. The kit is available from the nearest Fisher & Paykel Authorised Service Centre or our local website listed at the end of this document.

CAVITY PREPARATION

WIRING DIAGRAM

5

6

Important! SAVE THESE INSTRUCTIONSThe models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our local website listed at the end of this document or contact your local Fisher & Paykel dealer.

CN

WARNING! Electrical shock hazard

Before installing the DishDrawer®, remove the house fuse or open the circuit

breaker.

This appliance must be earthed. In the event of a malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-earthing conductor and an earthing plug. The plug must be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances. WARNING- Improper connection of the equipment-earthing conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly earthed.

Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box.

Failure to follow this advice may result in electrical shock or death.

WARNING! Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

Important safety instructions! Installation of this DishDrawer® requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer. Installation must comply with your local building and electricity regulations. At the completion of the DishDrawer® installation, the Installer must perform the Final Checklist. Remove all packaging materials supplied with the DishDrawer®. This DishDrawer® is manufactured for indoor use only. Ensure all water connections are turned OFF. It is the responsibility of the plumber and

electrician to ensure that each installation complies with all Codes and Regulations. The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required. The switched power outlet must be outside the DishDrawer® cavity, so that it is accessible after

installation. Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to

the power supply cord. If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid

damage from water spillage. Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not

be reused. Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims. If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle,

boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.

These marks indicate mounting bracket screw locations Preferred position. If adequate clearance, services hole can be higher to clear toekick space. If hole is higher, ensure drain hoses are routed straight into the waste connection.

+

Minimumthickness ofcavity sidesis 16mm

90°

Ø50mm services hole

can be either side

immediatelyadjacent to corner, +

600mm

580mmthroughout cavity

412m

m

67mm

97mm+

+

MoistureProtection Tape

100m

m

505mm

benchtop

moistureprotectiontape

10mm

10mm

*

Left hand side

Right hand side

Max. distance of hoses and cord from chassis edge

Left hand side

Right hand side

Drain hose 2000 mm 1800 mm

Inlet hose 1650 mm 1250 mm

Power cord (excl. plug) 1650 mm 1650 mm

Water Connection Recommended COLD (Maximum 60°c). 3/4 “ bSP (Gb20) to suit flat washer.

Water Pressure Max Min 1 MPa (145 psi) 0.1 MPa (14.5 psi)

Note: Services can be located

either side of DishDrawer®.

90o

10 mm

max. 450 mm

220-240 VAcmin. 9 A

Moisture protectiontape must be applied.

min. ø60 mm

* *min. 200 mm

Water supply

Page 2: Ø50mm services hole Important safety instructions! 5 ......PCB LCD / Badge 1 2 / 3 1.5mA +-0.82Aac 0. A a c 0.82Aac. 8 2 a 6.0 Aac 6.06Aac 1.5mA 2 5P 10 P601 2. 2 m A a c 0. 5 5 0

1

2

3

1

2

x 4

1 2 34

5

A

C C

BBA

4 5 6 7

8 9

10

19

2

1

13

3

optional

30 mm

1

2

3

4

5

5

5 ” (150 mm)

1

2

4

5

4

3B

1

2

3

1

2

x 4

1 2 34

5

A

C C

BBA

4 5 6 7

8 9

10

19

2

1

13

3

optional

30 mm

1

2

3

4

5

5

5 ” (150 mm)

1

2

4

5

4

3B

1

2

3

1

2

x 4

1 2 34

5

A

C C

BBA

4 5 6 7

8 9

10

19

2

1

13

3

optional

30 mm

1

2

3

4

5

5

5 ” (150 mm)

1

2

4

5

4

3B

1

1

1

2

3

4 5 6 7

8 9

101

3

4

3

22

2

3

4

30 mm

4

5 mm

optional

max. 19 mm

19

A

2

1

1

1

2

33

optional

Tie together to avoid kinking.

ensure product is level and aligning with cabinetry. Using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand.

Hexagonal socket

optional

max. 19 mm

1

1

1

2

3

4 5 6 7

8 9

101

3

4

3

22

2

3

4

30 mm

4

5 mm

optional

max. 19 mm

19

Important!D o not overtighten screw.

A A

B

ROUTE THE HOSES AND MOVE INTO THE CAVITY7

SECURE THE PRODUCT AND REFIT THE DRAWER9

REMOVE THE DRAWER AND LEVEL THE PRODUCT8

A

B

FIT THE TOEKICK10

PLUMBING AND DRAINAGE OPTIONS11

FINAL CHECKLIST12 TROUBLESHOOTING13

2

1

1

1

2

33

optionaloptional(x2)

ensure hoses and cordare not kinked or twisted.

B

1

2

3

1

2

x 4

1 2 34

5

A

C C

BBA

4 5 6 7

8 9

10

19

2

1

13

3

optional

30 mm

1

2

3

4

5

5

5 ” (150 mm)

1

2

4

5

4

3B

ensure the drawer is removed and then rotated anti-clockwiseto prevent kinked hoses.

150 mm

A

before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.

ensure the drawer clips on both sides are reset.

ensure the drawer is now rotated clockwise back.

B

OR Loosen feet only and take care when pushing the product into the cavity that you do not bend the feet.

If top mounting brackets are being used, ensure they’re securely fitted before sliding product into cavity.

The product has three pairs of mounting brackets: a pair of optional brackets on the top (C) and two pairs of formed brackets in the side of the chassis (A,B). Use at least two out of the three pairs to secure the product.

ensure the sound insulation is repositioned correctly.

Where the toekick meets the bottom of the tub is the cut-off point

check all parts are installed.ensure product is level, securely fastened to the cabinetry and opens and closes freely. The DishDrawer® must be free to fully close with no resistance from the cabinetry.ensure inlet hose to water supply has supplied rubber washer fitted and that it is tightened a further half turn after seal contact.ensure any knockouts or plugs in drain connection have been drilled out and drain connection has been made.The drain hose joiner must not support the weight of excess hoses. Keep hoses as fully extended as possible to prevent sagging. Any excess length of hose should be kept on the dishwasher side of the highloop.If using Plumbing and Drainage OPTION b, ensure the Highloop is a minimum 150 mm higher than the drain hose joiner.Turn on the power and water supply. Then press the Power ( ) button to turn the DishDrawer® on. The DishDrawer® should beep and Wash Programme lights light up.check the spray arm is in place and free to rotate.

Add three cups of water into the DishDrawer®. On the Wash Programme Selector Panel press Rinse and close the drawer(s). Start the programme by pressing the Start/Pause ( ) button.After the Rinse programme has finished, ensure machine has run and drained correctly.check water supply and drainage connection for leakage.

Repeat for each drawer.

Spray arm

Excessive water remaining above the filter plate, after the rinse cycle check for kinked drain hoses or blocked waste connection, high loop not

properly installed or drain hoses not routed correctly. No water supply

check water is connected, turned on and the spray arm(s) are correctly fitted and free to rotate.

No lights come on when the drawer is opened ensure power is connected and is switched on. check if Auto Power option is

on. Water around water supply and drainage connections

check connections, existing plumbing and hoses for leaks. check rubber washer and hose clamps are correctly fitted.

If product is tipping ensure the product is secured to the cabinetry. If front panels are misaligned

check and relevel product. check the cabinetry is square. Drawer(s) don’t close properly

ensure nothing is obstructing the drawer(s) from closing properly eg sound insulation, hoses or drawer latches.

If a problem occurs, consult the Troubleshooting section of the User Guide. If after checking these points you still need assistance, please refer to the

Service & Warranty book for warranty details and your nearest Authorised Service centre, or contact us through our website, listed below.

Manufactured by: Registered importer:Fisher & Paykel Appliances Mexico S.de R.L. de c.V.blvd Montebello Lotes 1,2,3Manzana 8, col.Parque Industrial colonial ReynosaTamaulipas c.P 88780Mexico

Quality certificate:

2

3

1

7

6

5

43

180o

2

750-882.5 mm

38 mm

max. 120 mm

750-882.5 mm

1

8

7

6

54

180o

A

If space is limited for fixing, push hoses through drain hose support to required height

DishDrawer® using sink trap with drain hose joiner

750

- 882

.5 m

m

min. R 200 mm

Supplied drain hose joiner19 mm waste tee

HIGHLOOPmin. 150 mm

ensure hoses are routed straight to joiner. Remove excess hose material if necessary.

DishDrawer® and Standpipe Ø 38 mm

Fit the supplied rubber washer

Fit the inlet hose adaptor (optional)

Fit the inlet hose adaptor (optional)

Fit the supplied rubber washer

B

Waste Disposal (optional)Do not connect to DishDrawer®

Waste Disposal (optional)Do not connect to DishDrawer®

750

- 882

.5 m

m

min. R 200 mm

www.fisherpaykel.cn 599870A CN 07.09

HAIER TO SUPPLY

Qingdao Haier International Trading co. LtdHaier Industrial ParkHaier RoadQingdao 266101P.R. china