Page 1: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

www.seifertsystems.com

501 9 6 5 - 2 0 1 5

50 Years Thermal Management

Enclosure Accessor ies

Page 2: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

Page

Cab ine t Heaters 4

KH 401 ser ies 5

KH 801 ser ies 6

KH 901 ser ies 7

F i l te r fans 8 - 12

Accessor ies F i l te r Fans 13

Thermosta t / Hygros ta t 14

Thermal Management So lu t ions 15

Table of Contents

Technical rights reserved

Page 3: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

Type Features Rated voltage Approval Page

Heating power Control cabinet heaters

KH 401 300 W • • CE, cULus 5

KH 401 350 W • • CE, cULus 5

KH 801 125 W • • • CE, cULus 6

KH 801 200 W • • • CE, cULus 6

KH 801 400 W • • CE, cULus 6

KH 801 800 W • • CE, cULus 6

KH 901 45 W • • CE 7

KH 901 60 W • • CE 7

KH 901 80 W • • CE 7

KH 901 100 W • • CE 7

KH 901 150 W • • CE 7

Max. Air volume flow Filter and Filter fansFF 4000 / 4000E Outlet filters CE, cURus 11

FL 4023 A 22 m3/h • • CE, cURus 11

FL 4210 D 47 m3/h • • CE, cURus 11

FL 4210 A 67 m3/h • • CE, cURus 11

FL 4411 A 110 m3/h • • CE, cURus 11

FL 4610 D 225 m3/h • • CE, cURus 11

FL 4620 A 230 m3/h • • CE, cURus 12

FL 4621 A 105 m3/h • • CE, cURus 12

FL 4830 A 520 - 610 m3/h • • • CE, cURus 12

FL 4880 A 618 - 840 m3/h • • • • CE, cURus 12

Thermostats / HygrostatsCC 301010 Thermostat (NC) • CE 14

CC 301030 Thermostat (NO) • CE 14

CC 301210 Change over Thermostat • CE 14

CC 301310 Twin Thermostat • CE 14

CC 301610 Change over Hygrostat • • CE 14

CC 301710 Change over Thermostat &Change over Hygrostat

• • CE 14

230 V

400 V

24 V

12 V

120 V

460 V

48 V

Page 4: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

4 www.seifertsystems.com

Cabine t fan hea ters Cab ine t hea te rs a re an impo r tan t segmen t o f t he Se i f e r t cab ine t accesso r i es p rog ram and fo rm pa r t o f ou r t he rma l managemen t so lu t i ons .

Tempera tu re d i f fe rences in cab ine ts , mos t ly in ou tdoor app l i ca t ions , o f ten resu l t in humid i ty and condensat ion wh ich may cause func t ion fa i lu res and cor ros ion . The use o f the appropr ia te hea t ing un i t fo r your cab ine t w i l l e l im ina te these p rob lems.

Fan heaters have a smal l and compact des ign , they heat up dynamica l l y and a re very qu ie t in opera t ion . The in te rna l warm a i r i s equa l l y d is t r ibu ted th roughout the con t ro l cab ine t . Fur ther advantage o f fan hea ters compared to PTC heaters i s the much lower s ta r t ing cur ren t .

PTC heaters a re compact in s ize , have a w ide vo l tage range and the heat ing power ad jus ts in re la t ion to the ambien t tempera tu re , resu l t ing in be t te r e f f i c iency.

Page 5: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

5www.seifertsystems.com

KH 401 Fan Heater ser ies

DIN ra i l c l ip fo r : D IN ra i l 15mm DIN ra i l 35mm G - ra i l

Screw mount s ide Screw mount back

De l i very inc ludes DIN ra i l c l ip and sc rew mount

Click herefor full

technicalspecifications

Part-no. Power output @ 10°C Fan air flow Voltage / Frequency Operating

temp. rangeDimensions

(H x W x D) mm QR Code

401300DSA7C000 300 W 10 m³/h 100 - 240 V - 50/60 Hz Fan 24 V -10°C - +70°C 92 x 54 x 79

KH 401401350DCA7C000 350 W 17 m³/h 100 - 240 V - 50/60 Hz

Fan 24 V -40°C - +70°C 92 x 54 x 79

Page 6: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

6 www.seifertsystems.com

KH 801 Fan Heater ser ies

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Part-no. Power output @ 10°C Fan air flow Voltage / Frequency Operating

temp. rangeDimensions

(H x W x D) mm QR Code

801125A44001 125 W 27 m³/h 230 V - 50/60 Hz -20°C - +40°C 137 x 111 x 116

KH 801- 125W

801125A33001 125 W 27 m³/h 120 V - 50/60 Hz -20°C - +40°C 137 x 111 x 116

801125D22001 125 W 27 m³/h 24 V DC -20°C - +40°C 137 x 111 x 116

801200A44001 200 W 27 m³/h 230 V - 50/60 Hz -20°C - +40°C 137 x 111 x 116

KH 801 - 200W

801200A33001 200 W 27 m³/h 120 V - 50/60 Hz -20°C - +40°C 137 x 111 x 116

801200D22001 200 W 27 m³/h 24 V DC -20°C - +40°C 137 x 111 x 116

801400A44001 400 W 44 m³/h 230 V - 50/60 Hz -20°C - +40°C 190 x 111 x 116

KH 801 - 400W801400A33001 400 W 44 m³/h 120 V - 50/60 Hz -20°C - +40°C 190 x 111 x 116

801800A44001 800 W 44 m³/h 230 V - 50/60 Hz -20°C - +40°C 190 x 111 x 116

KH 801 - 800W801800A33001 800 W 44 m³/h 120 V - 50/60 Hz -20°C - +40°C 190 x 111 x 116

Page 7: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

7www.seifertsystems.com

KH 901 PTC & Fan Heater ser ies

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Part-no. Connection Power output @ 10°C Voltage / Frequency Operating

temp. rangeDimensions

(H x W x D) mm QR Code

901130901110

Terminal blockCable 45 W 100 - 240 V - 50/60 Hz -30°C - +50°C 138.5 x 61.5 x 85

108.5 x 61.5 x 85KH 901 - 45W

901230901210

Terminal blockCable 60 W 100 - 240 V - 50/60 Hz -30°C - +50°C 138.5 x 61.5 x 85

108.5 x 61.5 x 85KH 901 - 60W

901330901310

Terminal blockCable 80 W 100 - 240 V - 50/60 Hz -30°C - +50°C 188.5 x 61.5 x 85

158.5 x 61.5 x 85KH 901 - 80W

901430901410

Terminal blockCable 100 W 100 - 240 V - 50/60 Hz -30°C - +50°C 188.5 x 61.5 x 85

158.5 x 61.5 x 85KH 901 - 100W

901530901510

Terminal blockCable 150 W 100 - 240 V - 50/60 Hz -30°C - +50°C 238.5 x 61.5 x 85

208.5 x 61.5 x 85KH 901 - 150W

Page 8: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

8 www.seifertsystems.com

Rapid ins ta l la t ionMount ing w i thou t sc rews, jus t by s imp lypress ing i t on to the enc losure cu tou t .

Opera t iona l sa fe tyReplacement o f the f i l te r f rom the ou ts ide ,w i thou t too ls .

S l ide open ingCover f i xed to and re leased f rom basev ia s l id ing ca tches .

EMC compl ianceEMC mode ls ava i lab le .

Page 9: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

9www.seifertsystems.com

FF 4000 Outlet filter series

Q = Air flow [m3/h]P = Static pressure [Pa]

UL listed Type 12

EMC and NEMA 3R models are available on request

Click herefor full

technicalspecifications

Part-no. Filtering class EN 779

Operating temp.range

Dimensions (H x W x D) mm

Cut out dimensions(mm) IP rating QR Code

400000000 G3 -10ºC - +55ºC 106.5 x 106.5 x 23.2 92.5 x 92.5 (+0.5) IP 54

FF 4000

400010000 G3 -10ºC - +55ºC 150 x 150 x 29.2 125 x 125 (+1.5) IP 54

400020000 G3 -10ºC - +55ºC 203.9 x 203.9 x 29.5 177 x 177 (+1.5) IP 54

400030000 G3 -10ºC - +55ºC 250 x 250 x 33.8 223 x 223 (+1.5) IP 54

400040000 G3 -10ºC - +55ºC 325 x 325 x 34 291 x 291 (+1.5) IP 54

Page 10: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

10 www.seifertsystems.com

Fi l te r FansFi l te r fans a re used i f the des i red cab ine t tempera tu re can be cons tan t l y above the ambien t a i r tempera tu re .

In combina t ion w i th thermosta ts f rom Se i fe r t you can save on energy s ince the fan i s on ly on when ac tua l l y needed, on mater ia l because less consumpt ion o f f i l te r mats and on t ime s ince less c lean ing i s requ i red . A l l th is w i l l ensure a longer l i fe t ime o f the f i l te r fans and w i l l enhance your p rocess re l iab i l i t y and sa fe ty.

A l l our f i l te r fans a re a lso ava i lab le as EMC and NEMA 3R vers ions . NEMA 3R mode ls a re made ou t o f UV and f ros t res is tan t p las t i c mater ia l .

Spec ia l fea tu res o f our f i l te r fans a re :

- no too ls requ i red fo r ins ta l la t ion- sh ie lded and se l f - lubr ica t ing ba l l bear ing fans - permanent sea l ing gaske t in po lyure thane foam - f i l te r med ia can be c leaned, up to 10 t imes by wash ing , b low ing d ry and l igh t l y bea t ing- op t iona l f i x ing w i th sc rews (w i th EMC vers ions f i x ing w i th sc rews is mandatory )

How to use f i l te r fans cor rec t l y?

Pre fe rab ly use the f i l te r fan to b low the coo l ambien t a i r in to enc losure (F ig .2 .and F ig .3 ) . This ensures that a sl ight posi t ive pressure bui lds up inside the cabinet and that only f i l tered air f lows inside i t . The a i r b lown in to the cab ine t d isp laces the warm a i r wh ich ex i ts th rough the exhaus t f i l te r. I f however a i r i s d rawn ou t o f the cab ine t by suc t ion power (F ig .1 ) on ly f i l te red ambien t a i r shou ld en te r the cab ine t . Ensure tha t no un f i l te red a i r can en te r th rough poor sea ls o r cab le en t r ies .

I f you insta l l a combinat ion of f i l ter fan/exhaust f i l ter, the f i l ter fan should a lways be p laced in the lower th i rd of the cabinet and the exhaust f i l ter should be in the upper par t o f the cabinet to prevent heat pockets ins ide.

F ig .1 Exhaus t Sys tem Fig .2 Pressure & Exhaus t Sys tem Fig .3 Pressure Sys tem

Page 11: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

11www.seifertsystems.com

Q = Air flow [m3/h]P = Static pressure [Pa]

FL filter fan seriesUL listed Type 12

(R) = reverse airflow / EMC and NEMA 3R models are available on request

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Part-no. Max. airflow(50 Hz) Voltage / Frequency Dimensions

(H x W x D) mmCut out dimensions

(mm) IP rating QR Code

4023A4000 22 m³/h 230 V - 50/60 Hz 106.5 x 106.5 x 79.5 92.5 x 92.5 (+0.5) IP 54

FL 40234023A3000 22 m³/h 120 V - 50/60 Hz 106.5 x 106.5 x 79.5 92.5 x 92.5 (+0.5) IP 54

4210D20004210D2100 (R)

47 m³/h64 m³/h 24 V DC 150 x 150 x 73 125 x 125 (+1.5) IP 54

FL 4210

4210D7000 4210D7100 (R)

47 m³/h64 m³/h 48 V DC 150 x 150 x 73 125 x 125 (+1.5) IP 54

4210A40004210A4100 (R)

67 m³/h60 m³/h 230 V - 50/60 Hz 150 x 150 x 73 125 x 125 (+1.5) IP 54

4210A3000 4210A3100 (R)

67 m³/h60 m³/h 120 V - 50/60 Hz 150 x 150 x 73 125 x 125 (+1.5) IP 54

4411A40004411A4100 (R)

100 m³/h110 m³/h 230 V - 50/60 Hz 203.9 x 203.9 x 95.5 177 x 177 (+1.5) IP 54

FL 4411

4411A30004411A3100 (R)

110 m³/h110 m³/h 120 V - 50/60 Hz 203.9 x 203.9 x 95.5 177 x 177 (+1.5) IP 54

4610D20004610D2100 (R) 225 m³/h 24 V DC 250 x 250 x 124.2 223 x 223 (+1.5) IP 54

FL 4610

4610D70004610D7100 (R) 225 m³/h 48 V DC 250 x 250 x 124.2 223 x 223 (+1.5) IP 54

Page 12: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

12 www.seifertsystems.com

FL filter fan series

Q = Air flow [m3/h]P = Static pressure [Pa]

UL listed Type 12

(R) = reverse airflow / EMC and NEMA 3R models are available on request

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Part-no. Max. airflow(50 Hz) Voltage / Frequency Dimensions

(H x W x D) mmCut out dimensions

(mm) IP rating QR Code

4621A4000 4621A4100 (R)

105 m³/h110 m³/h 230 V - 50/60 Hz 250 x 250 x 111.8 223 x 223 (+1.5) IP 54

FL 4621

4621A3000 4621A3100 (R)

105 m³/h110 m³/h 120 V - 50/60 Hz 250 x 250 x 111.8 223 x 223 (+1.5) IP 54

4620A4000 4620A4100 (R)

230 m³/h245 m³/h 230 V - 50/60 Hz 250 x 250 x 124.2 223 x 223 (+1.5) IP 54

FL 4620

4620A3000 4620A3100 (R)

230 m³/h245 m³/h 120 V - 50/60 Hz 250 x 250 x 124.2 223 x 223 (+1.5) IP 54

4830A4000 4830A4100 (R)

520 m³/h550 m³/h 230 V - 50/60 Hz 325 x 325 x 160.2 291 x 291 (+1.5) IP 54

FL 4830

4830A3000 4830A3100 (R)

520 m³/h550 m³/h 120 V - 50/60 Hz 325 x 325 x 160.2 291 x 291 (+1.5) IP 54

4830A9000 540 m³/h 400 V - 50/60 Hz 3~ 325 x 325 x 160.2 291 x 291 (+1.5) IP 54

4880A4000 4880A4100 (R)

670 m³/h720 m³/h 230 V - 50/60 Hz 325 x 325 x 158.5 291 x 291 (+1.5) IP 54

FL 4880

4880A3000 4880A3100 (R)

670 m³/h720 m³/h 120 V - 50/60 Hz 325 x 325 x 158.5 291 x 291 (+1.5) IP 54

4880A9000 4880A9100 (R)

618 m³/h648 m³/h 400 V - 50/60 Hz 3~ 325 x 325 x 158.5 291 x 291 (+1.5) IP 54

6060A4000 420 m³/h 230 V - 50/60 Hz 324 x 324 x 94 175 x 175 (+1.5) IP 54

FL 60606060A3000 490 m³/h 120 V - 50/60 Hz 324 x 324 x 94 175 x 175 (+1.5) IP 54

Page 13: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

13www.seifertsystems.com

Accessor ies | F i l te r Fans FL ser ies

Spare f i l te r mats• Made o f thermo- l inked progress ive s t ruc tu re syn the t i c f ib re .

• F i l te r c lass G3, accord ing to EN 779. Other f i l te r c lasses l i ke G4 ava i lab le on reques t .

• UL 900 C lass 2 approved and se l f -ex t ingu ish ing in F1 c lass , accord ing to DIN 53 438.

• F i l te r med ia can be c leaned, up to 10 t imes by wash ing , b low ing d ry and l igh t l y bea t ing .

Outlet filter / filter fan Part numberFF - 4000 000 / FL - 40xx FM - 4000 000FF - 4000 100 / FL - 42xx FM - 4000 100FF - 4000 200 / FL - 44xx FM - 4000 200FF - 4000 300 / FL - 46xx FM - 4000 300FF - 4000 400 / FL - 48xx FM - 4000 400

B lank ing covers• I f the ex is t ing mount ing cu tou ts made to ins ta l l f i l te r fans need to be c losed, the f i l te r mats

can be rep laced us ing b lank ing covers thus e l im ina t ing the need o f any we ld ing o r o ther

mechan ica l mod i f i ca t ion .

Outlet filter / filter fan Part numberFF - 4000 000 / FL - 40xx FB - 4000 000FF - 4000 100 / FL - 42xx FB - 4000 100FF - 4000 200 / FL - 44xx FB - 4000 200FF - 4000 300 / FL - 46xx FB - 4000 300FF - 4000 400 / FL - 48xx FB - 4000 400

Sta in less s tee l hose-proo f weather / p ro tec t ion hoods• These covers a re par t i cu la r l y su i tab le fo r ou tdoor app l i ca t ions o r in the food indus t ry and are

ava i lab le in a l l f i l te r fan s izes .

• Th is cover p ro tec ts aga ins t sp lashes o f l i qu ids and so l id fo re ign ob jec ts and is eas i l y washab le .

• NEMA / UL type 1 , 2 , 3R, 4 , 4x , 12 , 13

Outlet filter / filter fan Part numberFF - 4000 000 / FL - 40xx FC - 4000 000FF - 4000 100 / FL - 42xx FC - 4000 100FF - 4000 200 / FL - 44xx FC - 4000 200FF - 4000 300 / FL - 46xx FC - 4000 300FF - 4000 400 / FL - 48xx FC - 4000 400

EMC part-no. 4000 XXXE

Page 14: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

14 www.seifertsystems.com

CC 301 Climate Controls

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Part-no. ºC / ºF Contacts Setting range Switching

power (AC)Operating temp. range /

HumidityDimensions

(H x W x D) mm QR Code

301010301011 Thermostat (NC) 15°C

59°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 40

CC 301010

301020301021 Thermostat (NC) 25°C

77°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 40

301030301031 Thermostat (NO) 35°C

95°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 40

CC 301030

301040301041 Thermostat (NO) 50°C

122°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 40

301050301051 Thermostat (NO) 60°C

140°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 40

301110301111 Thermostat (NC) -10 - +80°C

14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 42

CC 301110

301120301121 Thermostat (NO) -10 - +80°C

14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 42

301210301211

Twin Thermostat (NCNC)

-10 - +80°C 14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 72 x 42

CC 301210

301220301221

Twin Thermostat (NONO)

-10 - +80°C 14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 72 x 42

301230301231

Twin Thermostat (NCNO)

-10 - +80°C 14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 72 x 42

301310301311

Changeover Thermostat

-10 - +80°C 14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 52

CC 301310

301320301321

Thermostat with thermal feedback

-10 - +80°C 14°F - 176°F 100 V-15A / 250 V-10A -10°C - +80°C ±5K / 95% 65 x 39 x 52

301410 Changeover Hygrostat 40 - 90% 24 V - 230 V 0°C - +60°C ±5K / 95% 65 x 39 x 42

301510301511

Changeover Ther-mostat with relay

-10 - +80°C 14°F - 176°F 24 V DC / 16A -40°C - +80°C ±5K / 95% 65 x 39 x 42

CC 301510

301520301521

Changeover Ther-mostat with relay

-10 - +80°C 14°F - 176°F 100 V-15A / 250 V-10A -40°C - +80°C ±5K / 95% 65 x 39 x 42

301610 ChangeoverHygrostat 15 - 90% 24 V DC / 100 W -40°C - +80°C ±5K / 95% 65 x 39 x 42

CC 301610301620 Changeover

Hygrostat 15 - 90% 100 V-15A / 250 V-10A -40°C - +80°C ±5K / 95% 65 x 39 x 42

301710301711

Changeover Ther-mostat & Hygrostat

-10 - +80°C / 15 - 90%14°F - 176°F / 15 - 90 % 24 V DC / 100 W -40°C - +80°C ±5K / 95% 65 x 72 x 42

CC 301710

301810301811

Changeover Ther-mostat & Hygrostat

-10 - +80°C / 15 - 90%14°F - 176°F / 15 - 90 % 100 V-15A / 250 V-10A -40°C - +80°C ±5K / 95% 65 x 72 x 42

Page 15: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

15www.seifertsystems.com

Sei fe r t | Thermal Management So lu t ions

A i r / wa ter hea t exchangers

Our compact a i r -water hea t exchangers can be used i f a co ld water supp ly i s ava i lab le . One typ ica l app l i ca t ion i s d iss ipa t ion o f h igh heat f rom cont ro l cab ine ts . Some mode ls a re ava i lab le as 19” p lug- in mode ls w i th min ima l dep th , as we l l as in te rna l , top and s ide mount ing . These indus t ry p roven heat exchangers d iss ipa te f rom 650 W up to 5 .5 kW (L35W10@200 l /h ) . Wi th our modu la r sys tem se tup we can even reach per fo rmances o f up to 40 kW.

A i r / a i r hea t exchangers

O u r c o u n t e r f l o w a n d c r o s s f l o w h e a t e x c h a n g e r s a r e d e s i g n e d b o t h f o r o u t d o o r a n d i n d o o r a p p l i c a t i o n s . T h e S e i f e r t h i g h - e n d v a c u u m b r a z i n g t e c h n o l o g y i s b e s t - i n - c l a s s t h e r m a l d i s s i p a t i o n a n d m o s t c o m p a c t f o o t p r i n t i n t h e i n d u s t r y.

So l iTherm ComPact - the economica l a l l - round so lu t ion

The new So l iTherm ComPact l i ne has a new approach to the a i r cond i t ion ing o f con t ro l cab ine ts . The sur face t rea ted condenser and the h igh f in separa t ion p rov ide v i r tua l l y ma in tenance f ree a i r cond i t ioners fo r mos t o f the env i ronments . Based on our long exper ience in the deve lopment and produc t ion o f a i r cond i t ioners , we have op t im ized the ComPact ser ies to ach ieve a h igh e f f i c iency w i th ou ts tand ing COP va lues th roughout a l l mode ls . Re l iab i l i t y and user f r iend ly a re the bes t ways to descr ibe the e lec t ron ic con t ro l le r be ing used in the ComPact a i r cond i t ioners . The d isp lay ind ica tes tempera tu re and opera t ing s ta tus and can be eas i l y se t and ad jus ted by the user v ia a Touch Pad.

So l iTherm S l imL ine – f i l te r less a i r cond i t ioners

Max imum power to s ize ra t io – th is charac te r i zes the S l imL ine a i r cond i t ioners . Compat ib i l i t y w i th marke t s tandards ensures the cus tomer an easy in tegra t ion w i th h is enc losure o r cab ine t sys tems. S l i m L i n e a i r c o n d i t i o n e r s a r e d e s i g n e d t o o p e r a t e w i t h a b s o l u t e l y m i n i m u m m a i n t e n a n c e . T h e y a r e e c o - f r i e n d l y a n d d o n o t n e e d d i r t c o l l e c t i n g f i l t e r m a t s . A l l S l i m L i n e m o d e l s c a n b e o p e r a t e d w i t h 3 p h a s e 4 0 0 V / 5 0 H z a n d 4 6 0 V / 6 0 H z . M o d e l s f r o m 3 2 0 W u p t o 1 . 5 K W a r e a v a i l a b l e . T h e u n i t s c a n b e e x t e r n a l l y o r i n t e r n a l l y m o u n t e d a n d a r e o n l y 11 0 m m d e e p a n d t h e r e f o r e c u r r e n t l y t h e s l i m m e s t a i r c o n d i t i o n e r s o n t h e m a r k e t . A s o n l y s m a l l a p e r t u r e s n e e d t o b e c u t f o r m o u n t i n g , t h e c a b i n e t d o o r s r e m a i n s t a b l e .

Pe l t ie r – coo l ing un i ts

The innova t ive Pe l t ie r thermoe lec t r i c techno logy p rov ides an e f fec t i ve coo l ing so lu t ion v i r tua l l y ma in tenance f ree . The So l iTherm Pe l t ie r a i r cond i t ioners incorpora te the techno logy w i th in a s leek and modern des ign wh ich i s compact and w i th on ly 64 mm depth hard ly needs any space.The opera t ing tempera tu re i s f rom -20°C to +65°C. The ingress p ro tec t ion ra t ing i s IP 66 .

Coo lMatch - var iab le coo l ing capac i ty fo r your cab ine t

The u l t ra -compact and l igh twe igh t a i r cond i t ioners a re spec ia l l y des igned fo r sma l l enc losures w i th l im i ted mount ing a rea , ex te rna l o r recessed mounted in to f la t hous ing opera to r o r par t o f a 19” rack w i th on ly 3U un i t he igh t . The Coo lMatch Ser ies se ts new per fo rmance- to -s ize s tandards wh ich makes i t par t i cu la r l y su i tab le fo r app l i ca t ions such as ba t te ry coo l ing . In case o f emergency the DC opera t ion a l lows the un i t to be ba t te ry opera ted . Ex t remely s tab le cab ine t tempera tu res w i th on ly + / -0 .2K are ob ta ined . A l l th is comes w i th s ign i f i can t energy sav ings !

Page 16: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Acc2014.pdf ·  50 1965 - 2015 50 Years Thermal Management Enclosure Accessories

Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems AG Seifert Systems Inc. Seifert Systems Pty Ltd.

Haßlinghauser Str. 156 HF 09/10 Hal Far Industrial Estate Wilerstraße 16 75 Circuit Drive 105 Lewis Road58285 Gevelsberg Birzebbuga, BBG 3000 CH- 4563 Gerlafingen North Kingstown Wantirna South RI 02852 3152 VictoriaGermany Malta Switzerland USA Australia Tel. +49 (0) 2332 55124-0 Tel. +356 2220 7000 Tel. +41 (0) 32 675 35 51 Tel. +1 401-294-6960 Tel. +61 (3) 98 01 19 06Fax +49 (0) 2332 5512429 Fax +356 2165 2009 Fax +41 (0) 32 675 44 76 Fax +1 401-294-6963 Fax +61 (3) 98 87 08 45

©0

3/2

01

5

Se

ife

rt

Sy

ste

ms

/ D

oc

no

. 5

96

00

53

05

www.seifertsystems.com

www.facebook.com/sei fer t .mtmsystems

[email protected] [email protected] [email protected] [email protected]@seifertsystems.com