Page 1: 5-Terminal Components

Terminal Components

RDX2-125 Series Miniature Circuit Breaker

Confirms to: GB14048.2, IEC60947-2

Frame size: 125A

Rated current: 40~125A

Rated operating voltage: AC 220V/ 380V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 10kA

RDX2-125S Breaker special for Electric Meter

Series Miniature Circuit

Confirms to: GB10963.1

Frame size: 125A

Rated current: 63~125A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 3P+N

Breaking capacity: 6kA

RDX16-63S Series Breaker special for Electric Meter

Miniature Circuit

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 3P+N

Breaking capacity: (C6~C63) 6kA, (D6~D63) 6kA

RDX16-63G, GQ Series Over and UnderVoltage Protective MCB

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 230V

Number of pole: 1P+N, 3P+N

Breaking capacity: (C6~C40) 6kA, (C50~C63) 4.5kA (D6~D63) 4.5kA

RDX6-40 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 40A

Rated current: 6~40A

Rated operating voltage: AC 230V(220V)

Number of pole: 1P+N

Breaking capacity: 6kA

RDX6-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V(220V)/400V (380V)

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 10kA

RDX30-32 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 32A

Rated current: 6~32A

Rated operating voltage: AC 220V(230V)

Number of pole: 1P+N

Breaking capacity: 4.5kA

DZ47-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: (C1~C40) 6kA, (C50~C63) 4kA (D1~D63) 4kA

025 www.peopleelectric.com

Terminal Components

Page 2: 5-Terminal Components

Terminal Components

RDX2-125 Series Miniature Circuit Breaker

Confirms to: GB14048.2, IEC60947-2

Frame size: 125A

Rated current: 40~125A

Rated operating voltage: AC 220V/ 380V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 10kA

RDX2-125S Breaker special for Electric Meter

Series Miniature Circuit

Confirms to: GB10963.1

Frame size: 125A

Rated current: 63~125A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 3P+N

Breaking capacity: 6kA

RDX16-63S Series Breaker special for Electric Meter

Miniature Circuit

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 3P+N

Breaking capacity: (C6~C63) 6kA, (D6~D63) 6kA

RDX16-63G, GQ Series Over and UnderVoltage Protective MCB

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 230V

Number of pole: 1P+N, 3P+N

Breaking capacity: (C6~C40) 6kA, (C50~C63) 4.5kA (D6~D63) 4.5kA

RDX6-40 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 40A

Rated current: 6~40A

Rated operating voltage: AC 230V(220V)

Number of pole: 1P+N

Breaking capacity: 6kA

RDX6-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V(220V)/400V (380V)

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 10kA

RDX30-32 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 32A

Rated current: 6~32A

Rated operating voltage: AC 220V(230V)

Number of pole: 1P+N

Breaking capacity: 4.5kA

DZ47-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: (C1~C40) 6kA, (C50~C63) 4kA (D1~D63) 4kA

025 www.peopleelectric.com

Terminal Components

Page 3: 5-Terminal Components

RDX6LE-63 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16917.1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 220V/ 380V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4P

Residual operated current: 30mA~300mA

Breaking capacity: 10kA

DZ47LE-63Y Series Residual CurrentOperated Circuit Breaker

Confirms to: GB

Frame size: 63A

Rated current: 6~40A

Rated operating voltage: AC 230V

Number of pole: 1P+NResidual operated current: 30mA

Breaking capacity: (C6~C40) 6kA, (C50~C63) 4.5kA

16917.1

RDX65-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 4~63A

Rated operating voltage: AC 230V(220V)/ 400V(380V)

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 6kA

RDB2-125 Breaker

Series Miniature Circuit

Confirms to: GB14048.2, IEC6947-2

Frame size: 125A

Rated current: 63~125A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 15kA

RDB2-125S Series Breaker

Miniature Circuit

Confirms to: GB10963.1, IEC60898-1

Frame size: 125A

Rated current: 63~125A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 3P+N

Breaking capacity: 10kA

RDB67-63 Series Miniature CircuitBreaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 6kA

RDB5-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: (C1~C63) 6kA, (D1~D63) 6kA

RDX6-63DC Series DC MiniatureCircuit Breaker

Confirms to: GB10963.2

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V/400V, DC220V/440V

Number of pole: 1P, 2P

Breaking capacity: 6kA

RDX2LE-125 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB14048.2, IEC60947-2

Frame size: 125A

Rated current: 40~125A

Rated operating voltage: AC 230V/400V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4P

Residual operated current: 30mA~300mA

Breaking capacity: 10kA

RDX6LE-40 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16917.1

Frame size: 40A

Rated current: 6~40A

Rated operating voltage: AC 220V

Number of pole: 1P+N

Residual operated current: 30mA

Breaking capacity: 10kA

RDX30LE-32 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16917.1

Frame size: 32A

Rated current: 6~32A

Rated operating voltage: AC 220V(230V)

Number of pole: 1P+N

Residual operated current: 30mA

Breaking capacity: 4.5kA

DZ47LE-32, 63 Series Residual Current Operated Circuit Breaker

Confirms to: GB16917.1

Frame size: 32, 63A

Rated current: 6~63A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4P

Residual operated current: 30mA

Breaking capacity: (C6~C40) 6kA, (C50~C63) 4.5kA (D6~D63) 4.5kA

RDX30LE-32Y Series Residual Current Operated Circuit Breaker

Confirms to: GB16917.1

Frame size: 32A

Rated current: 6~63A

Rated operating voltage: AC 220V(230V)

Number of pole: 1P+N

Residual operated current: 30mA

Breaking capacity: 4.5kA

RDX65LE-63 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB

Frame size: 63A

Rated current: 4~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4PResidual operated current: 30mA

Breaking capacity: (4~40A) 4kA, (50~63) 6kA

16917.1

PID-63 Series Residual Current Operated Circuit Breaker

Confirms to: GB16916.1, IEC61008-1

Frame size: 63A

Rated current: 25~63A

Rated operating voltage: AC 230V/400V

Number of pole: 2P, 4P

Residual operated current: 30mA

Breaking capacity: 6kA

PID-63E Series Residual Current Operated Circuit Breaker

Confirms to: GB16916.1, IEC61008-1

Frame size: 63A

Rated current: 25~63A

Rated operating voltage: AC 230V/400V

Number of pole: 2P, 4P

Residual operated current: 30mA

Breaking capacity: 6kA

027 www.peopleelectric.comwww.peopleelectric.com 026

Terminal Components

Page 4: 5-Terminal Components

RDX6LE-63 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16917.1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 220V/ 380V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4P

Residual operated current: 30mA~300mA

Breaking capacity: 10kA

DZ47LE-63Y Series Residual CurrentOperated Circuit Breaker

Confirms to: GB

Frame size: 63A

Rated current: 6~40A

Rated operating voltage: AC 230V

Number of pole: 1P+NResidual operated current: 30mA

Breaking capacity: (C6~C40) 6kA, (C50~C63) 4.5kA

16917.1

RDX65-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 4~63A

Rated operating voltage: AC 230V(220V)/ 400V(380V)

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 6kA

RDB2-125 Breaker

Series Miniature Circuit

Confirms to: GB14048.2, IEC6947-2

Frame size: 125A

Rated current: 63~125A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 15kA

RDB2-125S Series Breaker

Miniature Circuit

Confirms to: GB10963.1, IEC60898-1

Frame size: 125A

Rated current: 63~125A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 3P+N

Breaking capacity: 10kA

RDB67-63 Series Miniature CircuitBreaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 6~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: 6kA

RDB5-63 Series Miniature Circuit Breaker

Confirms to: GB10963.1, IEC60898-1

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Breaking capacity: (C1~C63) 6kA, (D1~D63) 6kA

RDX6-63DC Series DC MiniatureCircuit Breaker

Confirms to: GB10963.2

Frame size: 63A

Rated current: 1~63A

Rated operating voltage: AC 230V/400V, DC220V/440V

Number of pole: 1P, 2P

Breaking capacity: 6kA

RDX2LE-125 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB14048.2, IEC60947-2

Frame size: 125A

Rated current: 40~125A

Rated operating voltage: AC 230V/400V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4P

Residual operated current: 30mA~300mA

Breaking capacity: 10kA

RDX6LE-40 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16917.1

Frame size: 40A

Rated current: 6~40A

Rated operating voltage: AC 220V

Number of pole: 1P+N

Residual operated current: 30mA

Breaking capacity: 10kA

RDX30LE-32 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16917.1

Frame size: 32A

Rated current: 6~32A

Rated operating voltage: AC 220V(230V)

Number of pole: 1P+N

Residual operated current: 30mA

Breaking capacity: 4.5kA

DZ47LE-32, 63 Series Residual Current Operated Circuit Breaker

Confirms to: GB16917.1

Frame size: 32, 63A

Rated current: 6~63A

Rated operating voltage: AC 230V/ 400V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4P

Residual operated current: 30mA

Breaking capacity: (C6~C40) 6kA, (C50~C63) 4.5kA (D6~D63) 4.5kA

RDX30LE-32Y Series Residual Current Operated Circuit Breaker

Confirms to: GB16917.1

Frame size: 32A

Rated current: 6~63A

Rated operating voltage: AC 220V(230V)

Number of pole: 1P+N

Residual operated current: 30mA

Breaking capacity: 4.5kA

RDX65LE-63 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB

Frame size: 63A

Rated current: 4~63A

Rated operating voltage: AC 230V/400V

Number of pole: 1P+N, 2P, 3P, 3P+N, 4PResidual operated current: 30mA

Breaking capacity: (4~40A) 4kA, (50~63) 6kA

16917.1

PID-63 Series Residual Current Operated Circuit Breaker

Confirms to: GB16916.1, IEC61008-1

Frame size: 63A

Rated current: 25~63A

Rated operating voltage: AC 230V/400V

Number of pole: 2P, 4P

Residual operated current: 30mA

Breaking capacity: 6kA

PID-63E Series Residual Current Operated Circuit Breaker

Confirms to: GB16916.1, IEC61008-1

Frame size: 63A

Rated current: 25~63A

Rated operating voltage: AC 230V/400V

Number of pole: 2P, 4P

Residual operated current: 30mA

Breaking capacity: 6kA

027 www.peopleelectric.comwww.peopleelectric.com 026

Terminal Components

Page 5: 5-Terminal Components

RDX16L-63 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16916.1, IEC61008-1

Frame size: 63A

Rated current: 25~63A

Rated operating voltage: AC 230V/400V

Number of pole: 2P, 4P

Residual operated current: 30mA~300mA

Breaking capacity: 6kA

RDX16LE-63 Series Residual CurrentOperated Circuit Breaker

Confirms to: GB16916.1, IEC61008-1

Frame size: 63A

Rated current: 25~63A

Rated operating voltage: AC 230V/400V

Number of pole: 2P, 4P

Residual operated current: 30mA~300mA

Breaking capacity: 6kA

RDH3-125 Series Isolation Switch

Confirms to: GB14048.3

Frame size: 63A, 125A

Rated current: 32~125A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Rated short-time withstand current: 12Ie

HL32-100 Series Isolation Switch

Confirms to: GB14048.3

Frame size: 100A

Rated current: 32~100A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Rated short-time withstand current: 12Ie

RDX6SD-100 Series Isolation Switch

Confirms to: GB14048.3

Frame size: 100A

Rated current: 32~100A

Rated operating voltage: AC 230V/400V

Number of pole: 1P, 2P, 3P, 4P

Rated short-time withstand current: 12Ie

RDSP6 Series Surge Protector

Confirms to: GB18802.1

Nominal discharge current: 5kA~60kA

Max. discharge current: 10kA~100kA

Rated operating voltage: AC 220V/380V

Number of pole: 1P, 1P+N, 2P, 2P+N, 3P, 3P+N, 4P

RDCH8 Series Modular Contactor

Confirms to: GB17885, IEC61095

Rated current: 16~63A

Rated operating voltage: AC 500V

Number of pole: 1P, 2P, 3P, 4P

www.peopleelectric.com 028