IM 05P08D81-11EN page 1/4 Contents 1. Safety Precautions 2. Model and Suffix Codes 3. How to Install 4. Hardware Specifications 5. How to Connect Wires 6. Terminal Wiring Diagrams 7. Setup Procedure 8. Operations 9. Troubleshooting Introduction Thank you for purchasing the UT32A-D/MDL Controller. (The UT32A-D with option /MDL has no display.) This operation guide describes the installing, wirings, setup flow, and troubleshooting of the UT32A-D/MDL. The guide should be provided to the end user of this product. Be sure to read this operation guide before using the product in order to ensure correct operation. For details of each function, refer to the electronic manual. Before using the product, refer to the table of Model and Suffix Codes to make sure that the delivered product is consistent with the model and suffix codes you ordered. Also make sure that the following items are included in the package. • Digital Indicating Controller (the model you ordered) ..............................x1 • Unit Label (L4502VZ) ..............................................................................x1 • Tag Label (L4502VE) ..............................................................................x1 (Only when ordered.) • Operation Guide (this document) ............................................................x2 (A3 size) (Installation and Wiring, Initial Settings, Operations, and Parameters) l Target Readers This guide is intended for the following personnel; • Engineers responsible for installation, wiring, and maintenance of the equipment. • Personnel responsible for normal daily operation of the equipment. 1. Safety Precautions The following symbol is used on the instrument. It indicates the possibility of injury to the user or damage to the instrument, and signifies that the user must refer to the operation guide or user’s manual for special instructions. The same symbol is used in the operation guide and user’s manual on pages that the user needs to refer to, together with the term “WARNING” or “CAUTION.” WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and indicates precautions that should be taken to prevent such occurrences. CAUTION Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates pre- cautions that should be taken to prevent such occurrences. AC AC/DC The equipment wholly protected by double insulation or reinforced insulation. Functional grounding terminals (Do not use this terminal as a protective grounding terminal). Note Identifies important information required to operate the instrument. Warning and Disclaimer (1) YOKOGAWA makes no warranties regarding the product except those stated in the WARRANTY that is provided separately. (2) The product is provided on an "as is" basis. YOKOGAWA assumes no liability to any person or entity for any loss or damage, direct or indirect, arising from the use of the product or from any unpredictable defect of the product. Safety, Protection, and Modification of the Product (1) In order to protect the system controlled by this product and the product itself, and to ensure safe operation, observe the safety precautions described in the operation guide. Use of the instrument in a manner not prescribed herein may compromise the product's functions and the protection features inherent in the device. We assume no liability for safety, or responsibility for the product's quality, performance or functionality should users fail to observe these instructions when operating the product. (2) Installation of protection and/or safety circuits with respect to a lightning protector; protective equipment for the system controlled by the product and the product itself; foolproof or fail-safe design of a process or line using the system controlled by the product or the product itself; and/or the design and installation of other protective and safety circuits are to be appropriately implemented as the customer deems necessary. (3) Be sure to use the spare parts approved by YOKOGAWA when replacing parts or consumables. (4) This product is not designed or manufactured to be used in critical applications that directly affect or threaten human lives. Such applications include nuclear power equipment, devices using radioactivity, railway facilities, aviation equipment, air navigation facilities, aviation facilities, and medical equipment. If so used, it is the user’s responsibility to include in the system additional equipment and devices that ensure personnel safety. (5) Modification of the product is strictly prohibited. (6) This product is intended to be handled by skilled/trained personnel for electric devices. (7) This product is UL Recognized Component. In order to comply with UL standards, end-products are necessary to be designed by those who have knowledge of the requirements. WARNING l Power Supply Ensure that the instrument’s supply voltage matches the voltage of the power supply before turning ON the power. l Do Not Use in an Explosive Atmosphere Do not operate the instrument in locations with combustible or explosive gases or steam. Operation in such environments constitutes an extreme safety hazard. Use of the instrument in environments with high concentrations of corrosive gas (H 2 S, SO X , etc.) for extended periods of time may cause a failure. l Do Not Remove Internal Unit The internal unit should not be removed by anyone other than YOKOGAWA's service personnel. There are dangerous high voltage parts inside. Additionally, do not replace the fuse by yourself. l Damage to the Protective Construction Operation of the instrument in a manner not specified in the operation guide may damage its protective construction. CAUTION This instrument is an EMC class A product. In a domestic environ- ment this product may cause radio interference in which case the user needs to take adequate measures. 2. Model and Suffix Codes UT32A-D/MDL «Standard Code Model» Model Suffix code Option code Description UT32A /MDL (Required) Digital Indicating Controller (Power supply: 100-240 V AC) (provided with 3 DIs, and 3 DOs) (*2) Type 1: Basic control -D Dual-loop type Type 2: Functions 1 RS-485 communication (Max. 38.4 kbps, 2-wire/4-wire) Type 3: Open networks 0 None Fixed code -1 Temperature unit: deg C & deg F Case color 1 Black (Light charcoal gray) Fixed code -00 Always "-00" (for Standard Code Model) Option codes /MDL (Required) Mount on DIN rail (without the display parts and keys) /DC Power supply 24 V AC/DC /CT Coating (*1) /CV Terminal cover *1: When the /CT option is specified, the UT32A does not conform to the safety standards (UL and CSA) and CE marking (Products with /CT option are not intended for EEA-market). *2: UT32A-D has a panel mount type (without option /MDL). Please see the Operation Guide (IM 05P08D31-11EN). * For information on other Model types, see Manuals in Section-9. ■ Customized Product For customized product, the product is identified by the option code of /S# (where ‘#’ is a number). Contact your supplier in case your instrument has option /S#, and you are not in the possession of FX1-[Model code]-S# or IM [Model code]-S# (where [Model code] means, for example, UT55A). Accessories (sold separately) The following is an accessory sold separately. • LL50A Parameter Setting Software Model Suffix code Description LL50A -00 Parameter Setting Software • External Precision Resistor Model Suffix code Description X010 See the General Specifications (*) Resistance Module *: Necessary to input the current signal to the voltage input terminal. • Terminal Cover For UT32A: Model UTAP002 • Manuals Note: Manuals can be downloaded from a website. URL: http://www.yokogawa.com/ns/ut/im/ • Brackets Part number: L4502TP (2 pcs for upper and lower sides) • Wall mount bracket For UT32A-D/MDL: Model UTAP005 • Areas close to flammable articles Absolutely do not place the instrument directly on flam- mable surfaces. If such a circumstance is unavoidable and the instrument must be placed close to a flammable item, provide a shield for it made of 1.43 mm thick plated steel or 1.6 mm thick unplated steel with a space of at least 150 mm between it and the instrument on the top, bottom, and sides. • Areas subject to being splashed with water WARNING Be sure to turn OFF the power supply to the controller before in- stalling it on the enclosure to avoid an electric shock. Mounting on a DIN Rail Insert the DIN rail into the top area of DIN rail groove (at one location) on the rear panel, and secure in place with the bottom slide lock. DIN rail DIN rail Slide lock Fit into here Push CAUTION Make sure that foreign materials do not enter the inside of the in- strument through the case’s slit holes. Removing from the DIN Rail Insert a flat-blade screwdriver (guideline: 100 mm shaft length, 6 mm blade width, 0.8 mm blade thickness) into the bottom slide lock hole and pull down to release the slide lock. When slide lock is unlocked, the instrument can be removed from the DIN rail. DIN rail Slide lock Pull Push up DIN rail 150 mm 150 mm 150 mm 150 mm Operation Guide IM 05P08D81-11EN UT32A-D/MDL Digital Indicating Controller (Dual-loop, DIN Rail Mounting Type) Operation Guide This operation guide describes installation, wiring, and other tasks required to make the controller ready for operation. 4th Edition : Mar. 2018 «Standard Code Model» For details of the each function, refer to the electronic manual. Manuals can be downloaded or viewed at the following URL. Functional Enhancement http://www.yokogawa.com/ns/ut/im/ www.yokogawa.com/ns YOKOGAWA ELECTRIC CORPORATION Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JAPAN YOKOGAWA CORPORATION OF AMERICA Head office and for product sales 2 Dart Road, Newnan, Georgia 30265, USA YOKOGAWA EUROPE B.V. Headquarters Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS All Rights Reserved, Copyright © 2015 Yokogawa Electric Corporation Protection of Environment Waste Electrical and Electronic Equipment (WEEE), Directive This is an explanation of how to dispose of this product based on Waste Electrical and Electronic Equipment (WEEE), Directive. This directive is only valid in the EU. Marking This product complies with the WEEE Directive marking requirement. This marking indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category With reference to the equipment types in the WEEE directive, this product is classified as a “Small equipment” product. Do not dispose in domestic household waste. When disposing products in the EU, contact your local Yokogawa Europe B.V. office. 3. How to Install Installation Location The instrument should be installed in indoor locations meeting the following conditions: • Instrumented enclosure This instrument is designed to be mounted in an instrumented enclosure. Mount the instrument in a location where its terminals will not inadvertently be touched. Be sure to mount the instrument in an enclosure with a door. • Well ventilated locations Mount the instrument in well ventilated locations to prevent the instrument’s inter- nal temperature from rising. However, make sure that the terminal portions are not exposed to wind. Exposure to wind may cause the temperature sensor accuracy to deteriorate. To mount mul- tiple indicating controllers, see the external dimensions which follow. If mounting other instruments adjacent to the instrument, comply with these external dimen- sions to provide sufficient clearance between the instruments. • Locations with little mechanical vibration Install the instrument in a location subject to little mechanical vibration. • Horizontal location Mount the instrument horizontally and ensure that it is level, with no inclination to the right or left. Note If the instrument is moved from a location with low temperature and low humidity to a place with high temperature and high humidity, or if the temperature changes rapidly, condensation will result. Moreover, in the case of thermocouple inputs, measurement errors will result. To avoid such a situation, leave the instrument in the new environment under ambient conditions for more than 1 hour prior to using it. Do not mount the instrument in the following locations: • Outdoors • Locations subject to direct sunlight or close to a heater Install the instrument in a location with stable temperatures that remain close to an average temperature of 23°C. Do not mount it in locations subject to direct sunlight or close to a heater. Doing so adversely affects the instrument. • Locations with substantial amounts of oily fumes, steam, moisture, dust, or corrosive gases The presence of oily fumes, steam, moisture, dust, or corrosive gases adversely affects the instrument. Do not mount the instrument in locations subject to any of these substances. • Areas near electromagnetic field generating sources Do not place magnets or tools that generate magnetism near the instrument. If the instrument is used in locations close to a strong electromagnetic field generating source, the magnetic field may cause measurement errors.

4th Edition : Mar. 2018 Safety, Protection, and ... · Removing from the DIN Rail Insert a flat-blade screwdriver (guideline: 100 mm shaft length, 6 mm blade width, 0.8 mm blade thickness)

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 4th Edition : Mar. 2018 Safety, Protection, and ... · Removing from the DIN Rail Insert a flat-blade screwdriver (guideline: 100 mm shaft length, 6 mm blade width, 0.8 mm blade thickness)

IM 05P08D81-11EN page 1/4

Contents1. Safety Precautions2. ModelandSuffixCodes3. How to Install4. HardwareSpecifications5. HowtoConnectWires6. TerminalWiringDiagrams7. Setup Procedure8. Operations9. Troubleshooting

IntroductionThankyouforpurchasingtheUT32A-D/MDLController. (TheUT32A-Dwithoption /MDLhasnodisplay.)Thisoperationguidedescribestheinstalling,wirings,setupflow,andtroubleshootingoftheUT32A-D/MDL.Theguideshouldbeprovidedtotheenduserofthisproduct.Besure to read thisoperationguidebeforeusing theproduct inorder toensurecorrectoperation.Fordetailsofeachfunction,refertotheelectronicmanual.Beforeusingtheproduct,refertothetableofModelandSuffixCodestomakesurethatthedeliveredproduct isconsistentwith themodelandsuffixcodesyouordered.Alsomakesurethatthefollowingitemsareincludedinthepackage.

•DigitalIndicatingController(themodelyouordered) ..............................x1•UnitLabel(L4502VZ) ..............................................................................x1•TagLabel(L4502VE) ..............................................................................x1(Onlywhenordered.)•OperationGuide(thisdocument) ............................................................x2(A3size)(InstallationandWiring,InitialSettings,Operations,andParameters)

lTargetReadersThisguideisintendedforthefollowingpersonnel;• Engineersresponsibleforinstallation,wiring,andmaintenanceoftheequipment.• Personnelresponsiblefornormaldailyoperationoftheequipment.

1. Safety PrecautionsThe followingsymbol isusedon the instrument. It indicates thepossibilityof injuryto theuserordamageto the instrument,andsignifies that theusermustrefer to theoperationguideoruser’smanual forspecial instructions.Thesamesymbol isusedintheoperationguideanduser’smanualonpagesthattheuserneedstoreferto,togetherwiththeterm“WARNING”or“CAUTION.”

WARNING

Calls attention to actions or conditions that could cause serious or fatal injury to the user, and indicates precautions that should be taken to prevent such occurrences.

CAUTION

Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates pre-cautions that should be taken to prevent such occurrences.

AC

AC/DC

Theequipmentwhollyprotectedbydoubleinsulationorreinforcedinsulation.

Functionalgroundingterminals (Donotusethisterminalasaprotectivegroundingterminal).

NoteIdentifiesimportantinformationrequiredtooperatetheinstrument.

Warning and Disclaimer(1)YOKOGAWAmakesnowarrantiesregardingtheproductexceptthosestatedin

theWARRANTYthatisprovidedseparately.(2)Theproductisprovidedonan"asis"basis.YOKOGAWAassumesnoliabilityto

anypersonorentity forany lossordamage,director indirect,arisingfromtheuse of the product or from any unpredictable defect of the product.

Safety,Protection,andModificationoftheProduct(1) Inorder toprotect thesystemcontrolledbythisproductandtheproduct itself,

andtoensuresafeoperation,observethesafetyprecautionsdescribed in theoperationguide.Useof the instrument inamannernotprescribedhereinmaycompromise the product's functions and the protection features inherent in the device.Weassumenoliabilityforsafety,orresponsibilityfortheproduct'squality,performanceorfunctionalityshouldusersfailtoobservetheseinstructionswhenoperatingtheproduct.

(2) Installationof protectionand/or safety circuitswith respect toa lightningprotector;protectiveequipmentforthesystemcontrolledbytheproductandtheproductitself;foolprooforfail-safedesignofaprocessorlineusingthesystemcontrolledbytheproductortheproductitself;and/orthedesignandinstallationofotherprotectiveandsafetycircuitsaretobeappropriatelyimplementedasthecustomer deems necessary.

(3)BesuretousethesparepartsapprovedbyYOKOGAWAwhenreplacingpartsor consumables.

(4)Thisproduct isnotdesignedormanufacturedtobeusedincriticalapplicationsthatdirectlyaffector threatenhuman lives.Suchapplications includenuclearpower equipment, devices using radioactivity, railway facilities, aviationequipment,airnavigation facilities,aviation facilities,andmedicalequipment.If soused, it is theuser’s responsibility to include in thesystemadditionalequipmentanddevicesthatensurepersonnelsafety.

(5)Modificationoftheproductisstrictlyprohibited.(6)Thisproductisintendedtobehandledbyskilled/trainedpersonnelforelectricdevices.(7)ThisproductisULRecognizedComponent.InordertocomplywithULstandards,

end-productsarenecessarytobedesignedbythosewhohaveknowledgeoftherequirements.

WARNING

lPower Supply Ensure that the instrument’s supply voltage matches the voltage

of the power supply before turning ON the power.l Do Not Use in an Explosive Atmosphere Do not operate the instrument in locations with combustible

or explosive gases or steam. Operation in such environments constitutes an extreme safety hazard. Use of the instrument in environments with high concentrations of corrosive gas (H2S, SOX, etc.) for extended periods of time may cause a failure.

l Do Not Remove Internal Unit The internal unit should not be removed by anyone other than

YOKOGAWA's service personnel. There are dangerous high voltage parts inside. Additionally, do not replace the fuse by yourself.

l Damage to the Protective Construction Operation of the instrument in a manner not specified in the

operation guide may damage its protective construction.

CAUTION

This instrument is an EMC class A product. In a domestic environ-ment this product may cause radio interference in which case the user needs to take adequate measures.

2. ModelandSuffixCodes UT32A-D/MDL «Standard Code Model»

Model Suffixcode Option code Description

UT32A /MDL(Required)

DigitalIndicatingController(Powersupply:100-240VAC)(providedwith3DIs,and3DOs)(*2)

Type1:Basic control

-D Dual-looptype

Type2:Functions 1 RS-485communication(Max.38.4kbps,2-wire/4-wire)

Type3:Open networks 0 None

Fixedcode -1 Temperatureunit:degC&degFCasecolor 1 Black(Lightcharcoalgray)Fixedcode -00 Always"-00"(forStandardCodeModel)

Option codes

/MDL(Required) MountonDINrail(withoutthedisplaypartsandkeys)

/DC Powersupply24VAC/DC/CT Coating(*1)/CV Terminalcover

*1: Whenthe/CToptionisspecified,theUT32Adoesnotconformtothesafetystandards(ULandCSA)andCEmarking(Productswith/CToptionarenotintendedforEEA-market).

*2: UT32A-Dhasapanelmounttype(withoutoption/MDL).PleaseseetheOperationGuide(IM05P08D31-11EN).

*ForinformationonotherModeltypes,seeManualsinSection-9.

CustomizedProduct Forcustomizedproduct,theproductisidentifiedbytheoptioncodeof/S#(where‘#’isanumber).

Contactyoursupplier incaseyour instrumenthasoption /S#,andyouarenotin thepossessionofFX1-[Modelcode]-S#or IM[Modelcode]-S#(where[Modelcode]means,forexample,UT55A).

Accessories (sold separately)Thefollowingisanaccessorysoldseparately.• LL50AParameterSettingSoftware

Model Suffixcode DescriptionLL50A -00 ParameterSettingSoftware

• ExternalPrecisionResistorModel Suffixcode Description

X010 SeetheGeneralSpecifications(*) ResistanceModule

*:Necessarytoinputthecurrentsignaltothevoltageinputterminal.• TerminalCover ForUT32A:ModelUTAP002• Manuals Note:Manualscanbedownloadedfromawebsite.URL:http://www.yokogawa.com/ns/ut/im/• Brackets Partnumber:L4502TP(2pcsforupperandlowersides)• Wallmountbracket ForUT32A-D/MDL:ModelUTAP005

• Areasclosetoflammablearticles Absolutelydonotplacetheinstrumentdirectlyonflam-mablesurfaces. Ifsuchacircumstance isunavoidableandtheinstrumentmustbeplacedclosetoaflammableitem,provideashieldforitmadeof1.43mmthickplatedsteel or 1.6 mm thick unplated steel with a space of at least150mmbetweenitandtheinstrumentonthetop,bottom,andsides.

• Areas subject to being splashed with water

WARNING

Be sure to turn OFF the power supply to the controller before in-stalling it on the enclosure to avoid an electric shock.

Mounting on a DIN RailInsert theDINrail intothetopareaofDINrailgroove(atonelocation)ontherearpanel,andsecureinplacewiththebottomslidelock.

DIN rail

DIN rail

Slide lock

Fit into here

Push

CAUTION

Make sure that foreign materials do not enter the inside of the in-strument through the case’s slit holes.

Removing from the DIN RailInsertaflat-bladescrewdriver(guideline:100mmshaftlength,6mmbladewidth,0.8mmbladethickness)intothebottomslidelockholeandpulldowntoreleasetheslidelock.Whenslidelockisunlocked,theinstrumentcanberemovedfromtheDINrail.

DIN rail

Slide lock

Pull

Push up

DIN rail

150 mm150 mm

150 mm

150 mm

OperationGuideIM 05P08D81-11EN

UT32A-D/MDLDigital Indicating Controller (Dual-loop, DIN Rail Mounting Type)Operation Guide

This operation guide describes installation, wiring, and other tasks required to make the controller ready for operation.

4th Edition : Mar. 2018«Standard Code Model»

For details of the each function, refer to the electronic manual. Manuals can be downloaded or viewed at the following URL.

Functional

Enhancement

http://www.yokogawa.com/ns/ut/im/

www.yokogawa.com/ns

YOKOGAWA ELECTRIC CORPORATIONNetwork Solutions Business Division

2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 JAPANYOKOGAWA CORPORATION OF AMERICA

Head office and for product sales2 Dart Road, Newnan, Georgia 30265, USA

YOKOGAWA EUROPE B.V.Headquarters

Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS

All Rights Reserved, Copyright © 2015 Yokogawa Electric Corporation

Protection of Environment Waste Electrical and Electronic Equipment (WEEE), Directive

ThisisanexplanationofhowtodisposeofthisproductbasedonWasteElectricalandElectronicEquipment(WEEE),Directive.ThisdirectiveisonlyvalidintheEU.

MarkingThis product complieswith theWEEEDirectivemarkingrequirement.Thismarkingindicatesthatyoumustnotdiscardthiselectrical/electronicproductindomestichouseholdwaste.

ProductCategoryWithreferencetotheequipmenttypesintheWEEEdirective,thisproductisclassifiedasa“Smallequipment”product.Donot dispose in domestic householdwaste.WhendisposingproductsintheEU,contactyourlocalYokogawaEuropeB.V.office.

3. How to Install

Installation LocationThe instrument shouldbe installed in indoor locationsmeeting the followingconditions:• Instrumented enclosure This instrument isdesignedtobemounted inan instrumentedenclosure.Mounttheinstrumentinalocationwhereitsterminalswillnotinadvertentlybetouched. Be sure to mount the instrument in an enclosure with a door.• Well ventilated locations Mounttheinstrumentinwellventilatedlocationstopreventtheinstrument’sinter-naltemperaturefromrising.

However,makesurethattheterminalportionsarenotexposedtowind.Exposureto wind may cause the temperature sensor accuracy to deteriorate. To mount mul-tiple indicatingcontrollers,seetheexternaldimensionswhichfollow. Ifmountingother instrumentsadjacent to the instrument,complywith theseexternaldimen-sionstoprovidesufficientclearancebetweentheinstruments.

• Locations with little mechanical vibration Installtheinstrumentinalocationsubjecttolittlemechanicalvibration.• Horizontal location Mounttheinstrumenthorizontallyandensurethatitislevel,withnoinclinationtotherightorleft.

NoteIf the instrument ismovedfroma locationwith lowtemperatureand lowhumiditytoaplacewithhightemperatureandhighhumidity,or if thetemperaturechangesrapidly,condensationwill result.Moreover, in thecaseof thermocouple inputs,measurementerrorswillresult.Toavoidsuchasituation,leavetheinstrumentinthenewenvironmentunderambientconditionsformorethan1hourpriortousingit.

Donotmounttheinstrumentinthefollowinglocations:• Outdoors• Locations subject to direct sunlight or close to a heater Install the instrument in a location with stable temperatures that remain close to an averagetemperatureof23°C.Donotmountitinlocationssubjecttodirectsunlightorclosetoaheater.Doingsoadverselyaffectstheinstrument.

• Locations with substantial amounts of oily fumes, steam, moisture, dust, or corrosive gases

Thepresenceofoily fumes,steam,moisture,dust,orcorrosivegasesadverselyaffectstheinstrument.Donotmounttheinstrumentinlocationssubjecttoanyofthese substances.

• Areasnearelectromagneticfieldgeneratingsources Donotplacemagnetsortoolsthatgeneratemagnetismneartheinstrument.Iftheinstrument isusedin locationsclosetoastrongelectromagneticfieldgeneratingsource,themagneticfieldmaycausemeasurementerrors.

Page 2: 4th Edition : Mar. 2018 Safety, Protection, and ... · Removing from the DIN Rail Insert a flat-blade screwdriver (guideline: 100 mm shaft length, 6 mm blade width, 0.8 mm blade thickness)

IM 05P08D81-11EN page 2/4

•Inputbiascurrent:0.05µA(forTCorRTD)•Measuredcurrent(RTD):About0.16mA•Inputresistance: TCormVinput:1MΩormore Vinput:About1MΩ mAinput:About250Ω•Allowablesignalsourceresistance: TCormVinput:250Ωorless Effectsofsignalsourceresistance:0.1µV/Ωorless DCvoltageinput:2kΩorless Effectsofsignalsourceresistance:About0.01%/100Ω• Allowablewiringresistance: RTDinput:Max.150Ω/wire(Theconductorresistancebetweenthethreewires shallbeequal.)

Wiringresistanceeffect:±0.1ºC/10Ω• Allowableinputvoltage/current: TC,mV,mAandRTDinput:±10VDC Vinput:±20VDC mAinput:±40mA• Noiserejectionratio: Normalmode:40dBormore(at50/60Hz) Commonmode:120dBormore(at50/60Hz) For100-240VAC, thepower frequencycanbesetmanually.Automatic detectionisalsoavailable.

For24VAC/DC,thepowerfrequencycanbesetmanually.• Referencejunctioncompensationerror: ±1.0ºC(15to35ºC),±1.5ºC(-10to15ºCand35to50ºC)• Applicablestandards:JIS/IEC/DIN(ITS-90)forTCandRTD

ContactInputSpecifications(DI)• Numberofinputs:SeethetableofModelandSuffixCodes.• Inputtype:No-voltagecontactinputortransistorcontactinput• Inputcontactrating:12VDC,10mAormore Useacontactwithaminimumon-currentof1mAorless.• ON/OFFdetection: No-voltagecontactinput: Contactresistanceof1kΩorlessisdeterminedas“ON”andcontact resistanceof50kΩormoreas“OFF.” Transistorcontactinput: Inputvoltageof2Vorlessisdeterminedas“ON”andleakagecurrentmust notexceed100µAwhen“OFF.”• Minimumstatusdetectionholdtime:Controlperiod+50ms• Use:SPswitch,operationmodeswitch,andeventinput

AnalogOutputSpecifications(OUT,OUT2)• Numberofoutputs: Controloutput:2• Outputtype:Currentoutputorvoltagepulseoutput• Currentoutput:4to20mADCor0to20mADC/loadresistanceof600Ωorless• Currentoutputaccuracy:±0.1%ofspan(±5%ofspanfor1mAorless) Theaccuracy isthat inthestandardoperatingconditions:23±2°C,55±10%RH, andpowerfrequencyat50/60Hz.

• Voltagepulseoutput: Use:Timeproportionaloutput On-voltage:12Vormore/loadresistanceof600Ωormore Off-voltage:0.1VDCorless Timeresolution:10msor0.1%ofoutput,whicheverislarger

RelayContactOutputSpecifications(OUT,OUT2)• Contacttypeandnumberofoutputs: Controloutput:contactpoint1c;2points• Contactrating:240VAC,3Aor30VDC,3A(resistanceload)• Use:Timeproportionaloutput,ON/OFFoutput• Timeresolutionofcontroloutput:10msor0.1%ofoutput,whicheverislargerNote:Thecontroloutputshouldalwaysbeusedwithaloadof10mAormore.

MaintenacePortSpecificationsThemaintenanceport isusedtoconnectadedicatedcablewhenusingtheLL50AParameterSettingSoftware (soldseparately).Through thisport, youcansetcontrollerparameters,downloadladderprograms,andsoon.Fordetails,seetheLL50AUser’sManual(IM05P05A01-02EN).

Dedicated cable

LL50A Parameter Setting Software

To USB terminal

NoteUseLL50Awiththecontrollerturnedon.(Thededicatedcablemustbeconnected.LL50ALight-loaderadaptercannotbeused.)ThemaintenanceportisnotisolatedfromthePVinputterminal.Usetheportonlyformaintenancepurposes,suchasforsettingthecontrollerparameters.

SafetyandEMCStandards• Safety: CompliantwithIEC/EN61010-1(CE),IEC/EN61010-2-201(CE),IEC/EN61010-2-030(CE),approvedbyCAN/CSAC22.2No.61010-1(CSA),approvedbyUL61010-1.

Installationcategory:II Pollutiondegree:2 Measurementcategory:I(CATI)(UL,CSA) O(Other)(CE) Ratedmeasurementinputvoltage:Max.10VDC Ratedtransientovervoltage:1500V(*) *ThisisareferencesafetystandardvalueformeasurementcategoryIofCSA/UL61010-

1,andformeasurementcategoryOofIEC/EN61010-2-030.Thisvalueisnotnecessarilyaguaranteeofinstrumentperformance.

• EMCstandards: CompliantwithCEmarking EN61326-1ClassA,Table2(Foruseinindustriallocations), EN61326-2-3 *Theinstrumentcontinuestooperateatameasurementaccuracyofwithin±20%ofthe

rangeduringtesting. EN55011ClassA,Group1 EN61000-3-2ClassA EN61000-3-3 EMCRegulatoryArrangementinAustraliaandNewZealand(forallmodelinclud-

ingLL50A) EN55011ClassA,Group1• KCmarking: Electromagneticwave interferencepreventionstandard,electromagneticwave

protection standard compliance

Construction,Installation,andWiring• Construction:DINrailmountingtype• Material:Polycarbonate(Flameretardancy:UL94V-0) DINrailmountingbracketmaterial:Panelsteelsheet• Casecolor:Black(Lightcharcoalgray)• Weight:1kgorless• Externaldimensions(mm):48.2(width)x114(height)x100(depth)• CompatibleDINrails:TH35-7.5Fe,TH35-7.5Aℓ,JISC2812• Mountingposition:Horizontal.• Wiring:M3screwterminalwithsquarewasher(forsignalwiringandpowerwiring)

External Dimensions

UT32A-D/MDL

15(0.59)

48.2(1.90) 20(0.79) 100(3.94)

Unit: mm(inch)

60(2.36)

DIN railTH35-7.5

Cable for LL50

4.3(0.17)

4(0.

16)

91.6

(3.6

1)

114(

4.49

)10

0(3.

94)

94.6

(3.7

2)

Note:TrigonometryGeneral tolerance = ±(JIS B 0401-1998 tolerance class IT18)/2

Minimum ca

ble curva

ture: R40 (1

.57)

90 (3

.54)

min

.(r

equi

red

for r

emov

ing

the

inst

rum

ent f

rom

the

DIN

rail)

120

(4.7

2) m

in.

(requ

ired

for i

nser

ting/

rem

ovin

g th

e ca

ble

for L

L50A

)

4. HardwareSpecifications

WARNING

This instrument is for Measurement Category No.1.Do not use it for measurements in locations falling under Measure-ment Categories No.2, No.3, and No.4.

Internal Wiring

Outlet

Entrance IVCable

III TO( I )

II

Category IEC/EN/CSA/UL 61010-1 EN 61010-2-030 Remarks

No.1 Measurement CategoryI O(Other) For measurements performed on circuits not direct-

lyconnectedtoMAINS.

No.2 Measurement CategoryII

Measurement CategoryII

For measurements performed on circuits directly connectedtothelow-voltageinstallation.

No.3 Measurement CategoryIII

Measurement CategoryIII

Formeasurementsperformedinthebuildinginstal-lation.

No.4 Measurement CategoryIV

Measurement CategoryIV

For measurements performed at the source of the low-voltageinstallation.

InputSpecifications

UniversalInput(PV,PV2)• Numberofinputs:2• Inputtype,instrumentrange,andmeasurementaccuracy:Seethetablebelow,

Input Type Instrument Range

AccuracyºC ºF

Thermo-couple

K-270.0to1370.0ºC -450.0to2500.0ºF ±0.1%ofinstrumentrange±1digitfor

0°Cormore ±0.2%ofinstrumentrange±1digitforlessthan0°C ±2%ofinstrumentrange±1digitforlessthan-200.0°CofthermocoupleK±1%ofinstrumentrange±1digitforlessthan-200.0°CofthermocoupleT

-270.0to1000.0ºC -450.0to2300.0ºF-200.0to500.0ºC -200.0to1000.0ºF

J -200.0to1200.0ºC -300.0to2300.0ºF

T-270.0to400.0ºC -450.0to750.0ºF

0.0to400.0ºC -200.0to750.0ºF

B 0.0to1800.0ºC 32to3300ºF

±0.15%ofinstrumentrange±1digitfor400°Cormore ±5%ofinstrumentrange±1digitforlessthan400°C

S 0.0to1700.0ºC 32to3100ºF±0.15%ofinstrumentrange±1digit

R 0.0to1700.0ºC 32to3100ºF

N -200.0to1300.0ºC -300.0to2400.0ºF±0.1%ofinstrumentrange±1digit±0.25%ofinstrumentrange±1digitforlessthan0°C

E -270.0to1000.0ºC -450.0to1800.0ºF ±0.1%ofinstrumentrange±1digitfor0°Cormore ±0.2%ofinstrumentrange±1digitforlessthan0°C ±1.5%ofinstrumentrange±1digitforlessthan-200.0°CofthermocoupleE.

L -200.0to900.0ºC -300.0to1600.0ºF

U-200.0to400.0ºC -300.0to750.0ºF

0.0to400.0ºC -200.0to1000.0ºF

W 0.0to2300.0ºC 32to4200ºF ±0.2%ofinstrumentrange±1digit(Note2)

Platinel 2 0.0to1390.0ºC 32.0to2500.0ºF ±0.1%ofinstrumentrange±1digit

PR20-40 0.0to1900.0ºC 32to3400ºF

±0.5%ofinstrumentrange±1digitfor800°Cormore Accuracyisnotguaranteedforlessthan800°C.

W97Re3-W75Re25 0.0to2000.0ºC 32to3600ºF ±0.2%ofinstrumentrange±1digit

RTD

JPt100-200.0to500.0ºC -300.0to1000.0ºF ±0.1%ofinstrumentrange±1digit

(Note1)-150.00to150.00ºC -200.0to300.0ºF ±0.1%ofinstrumentrange±1digit

Pt100-200.0to850.0ºC -300.0to1560.0ºF ±0.1%ofinstrumentrange±1digit

(Note1)-200.0to500.0ºC -300.0to1000.0ºF-150.00to150.00ºC -200.0to300.0ºF ±0.1%ofinstrumentrange±1digit

Standardsignal0.400to2.000V

±0.1%ofinstrumentrange±1digit

1.000to5.000V4.00to20.00mA

DCvoltage/current

0.000to2.000V0.00to10.00V0.00to20.00mA-10.00to20.00mV0.0to100.0mV

Theaccuracyisthatinthestandardoperatingconditions:23±2°C,55±10%RH,andpowerfrequencyat50/60Hz.

Note1: ±0.3°C±1digitintherangebetween0and100°C,±0.5°C±1digitintherange between-100and200°C.

Note2: W:W-5%Re/W-26%Re(HoskinsMfg.Co.).ASTME988

•Inputsampling(control)period:200ms•Burnoutdetection: FunctionsatTC,RTD,andstandardsignal. Upscale,downscale,andoffcanbespecified. Forstandardsignal,burnoutisdeterminedtohaveoccurredifitis0.1Vor0.4 mAorless.

Page 3: 4th Edition : Mar. 2018 Safety, Protection, and ... · Removing from the DIN Rail Insert a flat-blade screwdriver (guideline: 100 mm shaft length, 6 mm blade width, 0.8 mm blade thickness)

IM 05P08D81-11EN page 3/4

PowerSupplySpecificationsandIsolation• Powersupply: Ratedvoltage:100-240VAC(+10%/-15%),50/60Hz 24VAC/DC(+10%/-15%)(for/DCoption)• Powerconsumption:15VA(DC:7VA,AC:11VAif/DCoptionisspecified)• Databackup:Nonvolatilememory• Powerholduptime:20ms(for100VACdrive)• Withstandingvoltage Betweenprimaryterminalsandsecondaryterminals:2300VACfor1minute(UL,CSA) Betweenprimaryterminalsandsecondaryterminals:3000VACfor1minute(CE) Betweenprimaryterminals:1500VACfor1minute Betweensecondaryterminals:500VACfor1minute (Primaryterminals:Power*andrelayoutputterminals;Secondaryterminals: AnalogI/Osignalterminals,contactinputterminals,communicationterminals andfunctionalgroundingterminals.)

*:Powerterminalsfor24VAC/DCmodelsarethesecondaryterminals.• Insulationresistance:Betweenpowersupplyterminalsandagroundingterminal20MΩormoreat500VDC

• Isolationspecifications

The circuits divided by lines are insulated mutually.

Control (analog) output terminal (OUT, OUT2)(not isolated between the analog output terminals)

PV1 (universal) input terminal, Maintenance port

PV2 (universal) input terminal

Control relay (2 a-contact) output terminal (OUT, OUT2)

Alarm-1 relay (a-contact) output terminal

Alarm-2 relay (a-contact) output terminal

Alarm-3 relay (a-contact) output terminal

Internal circuits

Power supply

Contact input terminal (3 points)RS485 communication terminal

Current transformer input terminal

EnvironmentalConditions

Normal Operating Conditions:• Ambienttemperature:-10to50°C• Ambienthumidity:20to90%RH(nocondensationallowed)• Magneticfield:400A/morless• Continuousvibrationat5to9Hz:Halfamplitudeof1.5mmorless,1oct/minfor90minuteseachinthethreeaxisdirections

Continuousvibrationat9to150Hz:4.9m/s2orless,1oct/minfor90minuteseachinthethreeaxisdirections

• Short-periodvibration:14.7m/s2,15secondsorless• Shock:98m/s2orless,11ms• Altitude:2000morlessabovesealevel• Warm-uptime:30minutesormoreafterthepoweristurnedon• Startuptime:Within10seconds *: TheLCD(aliquidcrystaldisplay)isusedforadisplayportionofthisproduct.

TheLCDhasacharacteristicthatthedisplayactionbecomeslateatthelow temperature.However,thecontrolfunctionisnotaffected.

Transportation and Storage Conditions:• Temperature:-25to70ºC• Temperaturechangerate:20ºC/horless• Humidity:5to95%RH(nocondensationallowed)

EffectsofOperatingConditions• Effectofambienttemperature: VoltageorTCinput:±1µV/ºCor±0.01%ofF.S./ºC,whicheverislarger Currentinput:±0.01%ofF.S./ºC RTDinput:±0.05ºC/ºC(ambienttemperature)orless Analogoutput:±0.02%ofF.S./ºCorless• Effectofpowersupplyvoltagefluctuation Analoginput:±0.05%ofF.S.orless Analogoutput:±0.05%ofF.S.orless (Eachwithinratedvoltagerange)

5. How to Connect Wires

WARNING

• Wiring work must be carried out by a person with basic electrical knowledge and practical experience.

• Be sure to turn OFF the power supply to the controller before wiring to avoid an electric shock. Use a tester or similar device to ensure that no power is being supplied to a cable to be connected.

• For the wiring cable, the temperature rating is 75 °C or more.• As a safety measure, always install a circuit breaker (an IEC

60947-compatible product, 5 A, 100 V or 220 V AC) in an easily accessible location near the instrument. Moreover, provide indication that the switch is a device for turning off the power to the instrument.

• Install the power cable keeping a distance of more than 1 cm from other signal wires.

• The power cable is required to meet the IEC standards concerned or the requirements of the area in which the instrument is being installed.

• Wiring should be installed to conform to NEC (National Electrical Code: ANSI/NFPA-70) or the wiring construction standards in countries or regions where wiring will be installed.

• Since the insulation provided to each relay output terminal is Functional insulation, provide Reinforced insulation to the external of the device as necessary. (Refer to the drawing below.)

This product

Functional insulation

A safety voltage circuit

A safety voltage circuit

This product

Reinforced insulation

Reinforced insulation

Functional insulation

A hazardous voltage circuit

A hazardous voltage circuit

A safety voltage circuit

A safety voltage circuit

This product

Reinforced insulation

Reinforced insulation

Functional insulation

A hazardous voltage circuit

A hazardous voltage circuit

A hazardous voltage circuit

A hazardous voltage circuit

CAUTION

• When connecting two or more crimp-on terminal lugs to the single terminal block, bend the crimp-on terminal lugs before tightening the screw.

• Note that the wiring of two or more crimp-on terminal lugs to the single high-voltage terminal of the power supply and relay, etc. does not comply with the safety standard.

CAUTION

• Provide electricity from a single-phase power supply. If the power is noisy, install an isolation transformer on the primary side, and use a line filter on the secondary side. When measures against noise are taken, do not install the primary and secondary power cables close to each other.

• If there is a risk of external lightning surges, use a lightning arrester etc.

• For TC input, use shielded compensating lead wires for wiring. For RTD input, use shielded wires that have low conductor resistance and cause no significant differences in resistance between the three wires.

• Since the control output relay has a life span (resistance load of 100,000 times), use the auxiliary relay to perform ON/OFF control.

• The use of inductance (L) loads such as auxiliary relays, motors and solenoid valves causes malfunction or relay failure; always insert a CR filter for use with alternating current or a diode for use with direct current, as a spark-removal surge suppression circuit, into the line in parallel with the load.

• After completing the wiring, the terminal cover is recommended to use for the instrument.

RecommendedCrimp-onTerminalLugs

(A)

(F)

(ød)

5.5 3.3

Recommendedtighteningtorque:0.6N·m Applicablewiresize:Powersupplywiring1.25mm2 or moreApplicable terminal lug Applicable wire size mm2 (AWG#) (φd) (A) (F)M3 0.25to1.65(22to16) 3.3 5.5 4.2

CableSpecificationsandRecommendedCablesPurpose Name and Manufacturer

Powersupply,relaycontactoutputs 600VGradeheat-resistantPVCinsulatedwires,JISC3317(HIV),0.9to2.0mm2

Thermocouple Shieldedcompensatingleadwires,JISC1610Forthermocoupleinput(PVinputandremoteinputwithdirectinput),shieldedcompensatingleadwireofcross-sectionalarealessthanorequalto0.75mm2isrecommended.Ifthecross-sectionalareaiswide,thereferencejunctioncompensationerrormaybelarge.

RTD Shieldedwires(three/fourconductors),UL2482(HitachiCable)Othersignals(otherthancontactinput/output) Shielded wiresOthersignals(contactinput/output) UnshieldedwiresRS-485communication Shielded wiresEthernetcommunication 100BASE-TX(CAT-5)/10BASE-T

DC Relay Wiring

R

External DC power supplyRelayUT32A-D

UT’s contact

Diode(Mount it directlyto the relay coilterminal (socket).)

Relay(Use one with a relay coil rating

less than the UT’s contact rating.)

AC Relay WiringUT32A-D

R

UT’s contact CR filter(Mount it directlyto the relay coilterminal (socket).)

External AC power supply

Relay(Use one with a relay coilrating less than the UT’s

contact rating.)

Transistor Output Wiring

power+ –

UTDO

LoadCOM

6. Terminal Wiring Diagrams

CAUTION

• Do not use an unassigned terminal as the relay terminal. Do not use a 100-240 V AC power supply for the 24 V AC/DC model; otherwise, the instrument will malfunction.

UT32A-D/MDL

TC input RTD input

Voltage (mV, V) input

A

+

-

+

-

Current (mA) input

+

-

B

b

111

201

202

203

204

205

206

207

208

209

210

101

102

103

104

105

106

107

108

109

110

211

212

101-112

301-312

201-212

302

303

301

302

303

302

303

303

304

PV2

Contact outputExternal contact output (relay)

AL3

AL2

AL1

Relay contact rating: 240 V AC, 1 A 30 V DC, 1 A (resistance load)

Alarm-3 output(PV high limit)

Alarm-2 output(PV low limit)

Alarm-1 output(PV high limit)

Common

Common

Common

UT104

105

106

107

108

109

ALM

Factory default: PV input type is 0-10V DC.

Loop-1 PV inputLoop-2 PV inputTC input RTD input

Voltage (mV, V) input

A

+

-

+

-

Current (mA) input

+

-

B

b202

203

201

202

203

202

203

203

204

PV1Factory default: PV input type is undefined.

Loop-1 and Loop-2 control outputRelay contact output

NO

NO

COM

Contact rating: 240 V AC, 3 A 30 V DC, 3 A (resistance load)

101

102

103

Factory default: Control output is relay.

OUTOUT2

112

Power supply24 V AC/DC power supply

-

+

100-240 V AC power supply

Allowable range: 100-240 V AC (+10%/-15%) (free voltage) 50/60 Hz shared

N

L

(24 V AC/DC power supply: Option code /DC)

110

111

110

111

112 112

N

L

Current/voltage pulse output

0-20 mA DC,4-20 mA DC,Voltage pulse (12 V)

-

Loop-2 control output

+ 205

206

OUT2Control output is relay at factory default.Current output range can be changed.

Loop-1 control outputCurrent/voltage pulse output

0-20 mA DC,4-20 mA DC,Voltage pulse (12 V)

+

-

207

208

OUT

Control output is relay at factory default.Current output range can be changed.

RS-485

SDB(+)

SDA(-)

RDB(+)

RDA(-)

SG

RS-485 communication(Suffix code: Type 2=1)

307

308

309

310

311

RS485

DIContact input

Contact rating: 12 V DC, 10 mA or more

External contact input

DI3

DI2

DI1

COMCommon

DI3

DI2

DI1

COM

+5V

+5V

+5V

No-voltagecontact

Transistor contactUP UP

209

210

211

212

209

210

211

212

Functions can be changed.

Loop-1 AUTO when DI1=ONLoop-1 MAN when DI1=OFF

Loop-2 AUTO when DI3=ONLoop-2 MAN when DI3=OFF

Loop-1 and Loop-2 STOP when DI2=ONLoop-1 and Loop-2 RUN when DI2=OFF

301

302

303

304

305

306

307

308

309

310

311

312

Page 4: 4th Edition : Mar. 2018 Safety, Protection, and ... · Removing from the DIN Rail Insert a flat-blade screwdriver (guideline: 100 mm shaft length, 6 mm blade width, 0.8 mm blade thickness)

IM 05P08D81-11EN page 4/4

7. Setup ProcedureThefollowingflowchartshowsthesetupprocedureforUT32A-D/MDL.PerformsetupthroughcommunicationortheLL50AParameterSettingSoftware(soldseparately).

Install and wire a controller.

Monitoring and control of regular operations

Adjust PID using auto-tuning or manually for PID control.

(Set parameters through communication.)

Operation

NO

YES

PID tuning

Installationand wiring

Power ON

ParameterSettings

ParameterSettings

Use LL50ASoftware?

LL50A: Parameter setting software (sold separately)See the LL50A Parameter Setting Software User’s Manual (IM 05P05A01-01EN).Use LL50A with the controller turned on. (The dedicated cable must be connected. LL50A Light-loader adapter cannot be used.)The maintenance port is not isolated from the PV input terminal. Use the port only for maintenance purposes, such as for setting the controller parameters.

To set parameters through communication, you need to create a program on the host device side. For controller parameter information (registers, relays), see the following manuals.• For setup through RS485 serial

communication or Ethernet communication, see the UTAdvanced Series Communi-cation Interface User’s Manual (IM 05P07A01-01EN).

• For setup through an open network, see the UTAdvanced Series Communication Interface (Open Network) User’s Manual (IM 05P07A01-02EN).

8. OperationsThecontrollerstatuscanbeverifiedwiththeLED.

Status LED Lit/Blinks DescriptionNormal Green LitCommunicationerror Green Blinks Checkthecommunicationwiringandsettings.

Instrument failure Red Lit Parametererror/Hardwarefailure/Ladderprogramcorruption.

Input error Red BlinksSensorburnout,inputover

Checktheinputwiringandsettings.

LED lamp

UT32A/MDL Front(with terminal cover)

Check theoperatingstatus (run/stop,auto/manual, remote/local, etc.) of thecontroller throughcommunicationor theLL50AParameterSettingSoftware(soldseparately).Fordetails,see the (1)UT32A-DDigital IndicatingControllerUser’sManual (IM05P08D81-01EN), (2)UTAdvancedSeriesCommunication Interface (RS-485,Ethernet)User’sManual(IM05P07A01-01EN),and(3)LL50AParameterSettingSoftwareUser’sManual(IM05P05A01-02EN).

9. TroubleshootingIfaproblemappearstobecomplicated,contactoursalesrepresentatives.

Is the controllerdefective?

Contact us for repair. Problem solved.

The LED lamp is unlit.

Yes

Yes

No

Yes

No

No

Yes

Check wiring of thepower terminals.

The LED lamp is flashing

in red.

(I/O signal failure?)

The LED lamp is lit in red.

Yes

No

Check the supply voltage.

Check the specifications and polarity

of connected devices .Check the communication-

related parameters.

Check the specificationsof communication

devices.

Check thecommunication wiring.

(Communication failure?)

Yes

Normal?

Check the specificationsof the controller.

Yes

NoCorrect?

Correct the error(s).

Check the I/O specificationsof the controller.

The LED lamp is flashing

in green.

Errors at Power OnTheerrorsshownbelowmayoccur in thefaultdiagnosiswhenthepower is turnedon.(FordetailsofSetpointdisplayand input/outputactionwheneacherroroccurs,seeUser’sManual(IM05P08D31-01EN).)YoucanviewthedetailsofeacherrorthroughcommunicationortheLL50AParameterSettingSoftware(soldseparately).(Viewontheregistermonitor.)Fordetailsoneachregister,seetheUTAdvancedSeriesCommunicationInterface(RS485,Ethernet)User’sManual(IM05P07A01-01EN).

LED display Parameter that displays error details Error description Cause and diagnosis Remedy

Unlit — FaultyMCURAM/MCUROM MCURAM/MCUROMarefailed. Faulty.Contactusforrepair.

Red,lit

Setupparameter(PA.ER)(Registerno.:2068)Bit0=1 System data error System data is corrupted. Faulty.Contactusforrepair.

Setupparameter(PA.ER)(Registerno.:2068)Bit1=1 Calibrationvalueerror Initializedtocalibrateddefaultvaluebecauseofcorruptedfactorydefault

value. Faulty.Contactusforrepair.

Setupparameter(PA.ER)(Registerno.:2068)Bit2=1

User(parameter)defaultvalueerror

Userparameteriscorrupted.Initializedtofactorydefaultvalue. Checkandreconfiguretheinitialized

settingparameters.Errorindicationiserased when the power is turned on again.

Setupparameter(PA.ER)(Registerno.:2068)Bit4=1 Setup parameter error Setup parameter data is corrupted.

Initializedtouserdefaultvalue.Setupparameter(PA.ER)(Registerno.:2068)Bit5=1 Operation parameter error Operation parameter data is corrupted.

Initializedtouserdefaultvalue.Setupparameter(PA.ER)(Registerno.:2068)Bit8=1 FaultyFRAM Datawriting(storing)toFRAMisimpossible. Faulty.Contactusforrepair.

Setupparameter(OP.ER)(Registerno.:2070)Bit0=1

Nonrespondinghardwareofextendedfunction(E1toE4-terminalareas)

Inconsistenceofsystemdataandhardwareofextendedfunction.Nonrespondingcommunicationbetweenhardwareofextendedfunction(E1toE4-terminalareas).

Faulty.Contactusforrepair.

Setupparameter(LA.ER)(Registerno.:2012)Bit0=1 Corruptedladderprogram Ladderprogramiscorrupted.

Operateswithoutladderprogram. Downloadtheladderprogramagain.

Errors during OperationTheerrorsshownbelowmayoccurduringoperation.(Forinput/outputactionwheneacherroroccurs,seeUser’sManual(IM05P08D31-01EN).)YoucanviewthedetailsofeacherrorthroughcommunicationortheLL50AParameterSettingSoftware(soldseparately).(Viewontheregistermonitor.)Fordetailsoneachregister,seetheUTAdvancedSeriesCommunicationInterface(RS485,Ethernet)User’sManual(IM05P07A01-01EN).

LED display Parameter that displayserror details Error description Cause and diagnosis Remedy

Red,lit

Setupparameter(AD1.E)(Registerno.:2001)PVinput:Bit0=1PV2input:Bit1=1

AnaloginputterminalADCerror•PVinput•PV2input(E1-terminalarea)

AnaloginputterminalADvalueerror Faulty.Contactusforrepair.

Setupparameter(AD1.E)(Registerno.:2001)PVinput:Bit5=1PV2input:Bit6=1

UniversalinputterminalRJCerror•PVinput•PV2input(E1-terminalarea)

UniversalinputterminalRJCerror

Faulty.Contactusforrepair.SettheparameterRJCtoOFFtoeraseerror indication.

Red,blinks

Setupparameter(AD1.E)(Registerno.:2001)PVinput:Bit8=1PV2input:Bit9=1

Analoginputterminalburnouterror•PVinput•PV2input(E1-terminalarea)

AnaloginputterminalsensorburnoutCheckwiringandsensor.Errorindicationiserasedinnormaloperation.

Setup parameterLoop-1(PV1.E)(Registerno.:2002)Bit0=1Loop-2(PV2.E)(Registerno.:2018)Bit0=1

PVinputburnouterror(Loop-1,Loop-2) BurnoutofanaloginputconnectedtoPV

Checkwiringandsensorofconnectedanaloginputterminals.Errorindicationiserasedinnormaloperation.

Setup parameterLoop-1(PV1.E)(Registerno.:2002)Over-scale:Bit4=1Under-scale:Bit5=1Loop-2(PV2.E)(Registerno.:2018)Over-scale:Bit4=1Under-scale:Bit5=1

PVinputover-scalePVinputunder-scale(PVvaluesoutof-5to105%)(Loop-1,Loop-2)

PVinputisoutof-5to105%.Alsooccurswhenthedataoutofrangewhich is the ladder calculation result is input.

Checkanaloginputvalueorladderprogram.

ChecktheerrorinLL50Asoftware.

Setupparameter(LA.ER)(Registerno.:2012)Overflow:Bit1=1Ladderprogramerror:Bit1=1Loadfactorover100%:Bit4=1Loadfactorover200%:Bit5=1

Laddercalculationoverflow Floatingpointcomputationforladdercalculationisinfinite. Checktheladderprogram.

Ladderprogramerror Ladderprogramiscorrupted.Downloadtheladderprogramagain.Iftheerrorindicationisstillnoterased,thereisafault.Contactusforrepair.

Loadfactorover100% Computationdoesnotendwithinthecontrolperiod(loadfactoris100%ormore).

Changethecontrolperiodorreducethe number of steps for the ladder program.

Loadfactorover200%(Forcedend)

Computationdoesnotendwithinthecontrolperiod(loadfactoris200%ormore).

Changethecontrolperiodorreducethenumberofstepsfortheladderprogram.

Green,blinks Setupparameter(OP.ER)(Registerno.:2070)Bit8=1 Peer-to-peercommunicationerror Peer-to-peercommunicationerror

Checkthatthetargetdevicesareconnected correctly.Recoveryatnormalreceipt.

ChecktheerrorinLL50Asoftware.

Setup parameterLoop-1(PV1.E)(Registerno.:2002)Bit14=1Loop-2(PV2.E)(Registerno.:2018)Bit14=1

Auto-tuningtime-out(Loop-1,Loop-2)

Auto-tuningdoesnotendevenwhen24hourshaveelapsedafterthestartoftuning.

Checktheprocess.Holddownanykeytoerase the error indication

Green,blinks Setupparameter(OP.ER)(Registerno.:2070)Bit8=1

Communicationerror(RS-485communication)

FramingparityerrorBufferoverflowInter-charactertime-outChecksumerror(PClinkcommunicationwithchecksum)CRCcheckerror(Modbus/RTU)LRCcheckerror(Modbus/ASCII)

Checkthecommunicationparameters.Recoveryatnormalreceipt.Holddownanykeytostopblinking.

Communicationerror(coordinatedoperation)

InconsistenceofloopbetweencoordinatedmasterandslavesCheckthecommunicationparameters.Recoveryatnormalreceipt.Changefromremotetolocalmodetostopblinking.Whenthemodeischangedfromremotetolocal,SPtrackingdoesnotworkevenifitissettoON.

Communicationfromcoordinatedmasterisinterruptedfor2seconds.

Red,lit Setupparameter(PA.ER)(Registerno.:2068)Bit8=1 FaultyFRAM Writing(storing)datatoFRAMisimpossible. Faulty.Contactusforrepair.

Unlit — FaultyMCU/DCU(ROM/RAMerror,corrupted) MCU/DCUiscorrupted. Faulty.Contactusforrepair.

• AuthorisedRepresentativeintheEEA YokogawaEuropeBV.(Address:Euroweg2,3825HDAmersfoort,TheNether-lands) istheAuthorisedRepresentativeofYokogawaElectricCorporationforthisProductintheEEA.

• Printed ManualsModel Description

UT35A,UT32ADigitalIndicatingController(PanelMountingType)OperationGuide«Standard code model»

IM05P01D31-11EN

UT35A,UT32ADigitalIndicatingController(PanelMountingType)OperationGuide«Detailedcodemodel»

IM05P01D31-15EN

UT35A/MDL,UT32A/MDLDigitalIndicatingController(DINRailMountingType)Operation Guide «Standard code model»

IM05P01D81-11EN

UT32A-DDigitalIndicatingController(Dual-loop,PanelMountingType)Operation Guide «Standard code model»

IM05P08D31-11EN

UT32A-D/MDLDigitalIndicatingController(Dual-loop,DINRailMountingType)Operation Guide «Standard code model»

IM05P08D81-11EN

UT35A/RSP,UT32A/RSPDigitalIndicatingController(Non-isolatedRemoteInput,PanelMountingType)OperationGuide«Standard code model»

IM05P01D31-81EN

UT32ADigitalIndicatingControllerOperationGuide«Entrymodel» IM05P01F31-11ENPrecautionsontheUseoftheUTAdvancedSeries IM05P01A01-11ENUTAP005WallMoountBracketUser'sManual IM05P06A31-02Z1

• ElectronicManuals Youcandownloadthelatestmanualsfromthefollowingwebsite: URL:http://www.yokogawa.com/ns/ut/im/

Model DescriptionUT35A,UT32ADigitalIndicatingController(PanelMountingType)OperationGuide«Standard code model»

IM05P01D31-11EN

UT35A,UT32ADigitalIndicatingController(PanelMountingType)OperationGuide«Detailedcodemodel»

IM05P01D31-15EN

UT35A/MDL,UT32A/MDLDigitalIndicatingController(DINRailMountingType)Operation Guide «Standard code model»

IM05P01D81-11EN

UT35A/UT32ADigitalIndicatingControllerUser’sManual IM05P01D31-01ENUT32A-DDigitalIndicatingController(Dual-loop,PanelMountingType)Operation Guide «Standard code model»

IM05P08D31-11EN

UT32A-D/MDLDigitalIndicatingController(Dual-loop,DINRailMountingType)Operation Guide «Standard code model»

IM05P08D81-11EN

UT32A-D,UT32A-D/MDLDigitalIndicatingControllerUser’sManual IM05P08D31-01ENUT35A/RSP,UT32A/RSPDigitalIndicatingController(Non-isolatedRemoteInput,PanelMountingType)OperationGuide«Standard code model»

IM05P01D31-81EN

UT32ADigitalIndicatingControllerOperationGuide«Entrymodel» IM05P01F31-11ENUT32ADigitalIndicatingControllerUser’sManual«Entrymodel» IM05P01F31-01ENUTAdvancedSeriesCommunicationInterface(RS-485,Ethernet)User’sManual IM05P07A01-01ENUTAdvancedSeriesCommunicationInterface(OpenNetwork)User’sManual IM05P07A01-02ENLL50AParameterSettingSoftwareInstallationManual IM05P05A01-01ENLL50AParameterSettingSoftwareUser’sManual IM05P05A01-02ENPrecautionsontheUseoftheUTAdvancedSeries IM05P01A01-11ENUTAP005WallMoountBracketUser'sManual IM05P06A31-02Z1

• GeneralSpecificationModel Description

UT35A/UT32ADigitalIndicatingController(PanelMountingType) GS05P01D31-01ENUT35A/MDL,UT32A/MDLDigitalIndicatingController(DINRailMountingType) GS05P01D81-01ENUT32A-DDigitalIndicatingController(Dual-loop,PanelMountingType) GS05P08D31-01ENUT32A-D/MDLDigitalIndicatingController(Dual-loop,DINRailMountingType) GS05P08D81-01ENLL50AParameterSettingSoftware GS05P05A01-01EN

* Thelasttwocharactersofthemanualnumberandgeneralspecificationnumberindicatethelanguageinwhichthemanualiswritten.