Upload
marsanne
View
230
Download
0
Embed Size (px)
Citation preview
7/31/2019 4B Commercial IMZones Handout
1/6
9/27/2012
1
1
B - 10:15-10:30
2
Wastewater Treatment Standards for ConventionalSystems
Operating Permit Requirements for CommercialWastewater Treatment Systems and I/M Zones.
Annual Operating Permit System Inspections
Maintenance Entities
System Maintenance Requirements
3
Conventional system treatment in I/M andCommercial Wastewater Situations: Levels of treatment that can be achieved by a
conventional baseline system.
What can and cannot be permitted by the DOH to
use a conventional baseline system for wastewatertreatment.
7/31/2019 4B Commercial IMZones Handout
2/6
9/27/2012
2
4
Conventional system treatment in I/M andCommercial Wastewater Situations :
What can and cannot be permitted by the DOH touse a conventional baseline system for wastewatertreatment.
5
POLLUTANTBASELINESYSTEM
STANDARDSSeptic tank
effluent
BASELINESYSTEM
STANDARDS@ baseof 24inchunsaturatedzone
AEROBICTREATMENT
UNIT(effluent)
SECONDARYTREATMENTSTANDARDS
(effluent)
ADVANCEDSECONDARYTREATMENTSTANDARDS
(effluent)
ADVANCEDWASTEWATERTREATMENTSTANDARDS
(effluent)
CBOD5(Carbonaceous Biochemical
Oxygen Demand)
120-240mg/l
< 5mg/l
=or< 25mg/l
=or< 20mg/l
=or< 10mg/l
=or< 5mg/l
TSS(TotalSuspended Solids)
65-176mg/l
< 5mg/l
=or< 30mg/l
=or< 20mg/l
=or< 10mg/l
=or< 5mg/l
TN(TotalNitrogen)
36-45mg/l
15-25mg/l
notapplicable
notapplicable
=or< 20mg/l
=or< 3mg/l
TP(TotalPhosphorus)
6-10mg/l
< 5mg/l
notapplicable
notapplicable
=or