CONTINUOUS VENTILATORS
Standard Size9" throat and 12" throat 10 foot sections. Other sizesavailable upon request. Low profile design can be used forsingle unit or continuous run installation with no disassem-bly.
Integral DampersEasy-moving damper opens to any degree from fully opento completely closed.
DesignAerodynamically proportioned to exclude weather pro-tects air passages and full outlet area.
Bird ScreenFully protected by 4 x 4 mesh galvanized hardware cloth.
ConstructionDurable 26 gauge exterior combined with internal compo-nents of 24, 20 and 18 gauge die formed sheet metal andmachined parts for long service life.
FinishPre-painted or galvalume is standard. Other materials and
finishes available upon request.Drainage AreaContinuous slot bottom of both sides of windbands.
used on metal roofing systems roofs conform to MPs high standards and specifications which have been
developed, tested and proven over many years. They provide an excellent value for the user.
8/13/2019 4.4Continuous Vents
2/16
DIMENSIONS AND TECHNICAL DATAB
A
C
D
E
THROAT
BIRD SCREEN
DIE-FORMED BAFFLE
RAIN SHIELD
DAMPER
LIFTER ARM
SADDLE STRAP
SIDE SKIRT
END CAP OF VENT END CAP OF VENT
DRAIN AT MULTI-UNIT SPLICE
ROOF PANEL MAJOR RIBNOTE:BREAK DRAIN ASSEMBLY TOFOLLOW EXACT ROOF SLOPE.
END CAP OF VENT
DRAIN AT CAPOF END VENT
ROOF PANEL MAJOR RIB
POP RIVET ENDCAP TO DRAINASSEMBLY
PULL BAR CONNECTION:Install turnbuckles betweenadjacent pull bars. With thedampers in the closed position,adjust turnbuckles starting atone end of the run.
PULL BARTURNBUCKLE
STOVE BOLT
DIMENSIONS (In Inches)
Throat* A B C D E
9 13 211
4 141
2 18 281
4*12 17 2812 18 22 33
SHIPPING WEIGHTS
StandardSize Boxed Pkg. Size
Crated
9" 124 lbs 209 lbs 12412" X 1912" X 3012"
12" 148 lbs 218 lbs 12412" X 23" X 35"
* Other sizes available upon request.
Chain-operated damper utilizes a rugged sash chain through chain locking device. Damper is spring-loaded to open and canbe adjusted to any opening from fully open to fully closed. Optional operator packages for multiple units or wall operation areavailable. (See below.)
RAIN SHIELDDAMPEREND CAP
LIFTER ARMGUIDE RODSPRING
PIVOT BRACKET & SADDLE STRAPPULL BAR
PULLEY AT FRAME OR WALL
PULL BAR IN CLOSED POSITION
TO CLOSE DAMPER, PULL CABLE
2" TRAVEL
STANDARD CABLE OPERATION
RAIN SHIELDDAMPEREND CAP
LIFTER ARMGUIDE RODSPRING
CHAIN CATCH (OPT.)CHAIN WITH HANDLE
PIVOT BRACKET &SADDLE STRAP
PULL BAR
OPTIONAL PULL CHAIN OPERATION(SINGLE UNITS ONLY)
PULL CHAIN MUST BEREMOVED FOR CONTINUOUSRUN OPERATION
8/13/2019 4.4Continuous Vents
3/16
L o u v e r s V e n t i l a t o r s T r i m R o o f C u r b s S p e c i a l t y I t e m s
9" CONTINUOUS VENTILATOR SPECIFICATIONSVentilators are of low profile design to provide gravity type ventilation.
Birdscreen is provided to prevent nesting and each unit contains flashing for eithersingle unit or continuous-run installation.
Each unit is 9" x 10' with a base ventilating capacity of 2700 CFM at 20
temperature differential with a 25' stack height.
Exterior parts are 26GA. G90 galvanized, painted galvanized or galvalume.ASTMA446.
Interior parts are all of G90 galvanized steel.
Substructure consists of 10GA. saddle straps with interior baffles of 24GA.
Pull bars and pivot brackets are of 20GA. Lifter arms and damper slides are of18GA.
Manual operation is through activation of pull bar, which is attached to bell-cranked type lifter arms connected to damper with teflon coated pins throughdamper slides.
Dampers are spring loaded to remain in open position until pull bar isoperated and locked in the closed position. Dampers operate in vertical manor.
Birdscreen is 4x4 mesh galvanized hardware cloth.
8/13/2019 4.4Continuous Vents
4/16
B
A
C
D
E
THROAT
DIMENSIONS (In Inches)
Throat A B C D E4 614 1212 9 10 18
9 13 2114 1412 18 2814
12 17 2812 18 22 33
18 2634 4558 3058 30 49
24 3312 57 3838 3618 5818
36 4712 8114 5358 55 8312
SHIPPING WEIGHTS
Size Boxed Standard Crated Pkg. Size
9" 124 lbs 209 lbs 12412" X 1912" X 3012"
12" 148 lbs 218 lbs 12412" X 23" X 35"
8/13/2019 4.4Continuous Vents
5/16
WELDED FRAME VENTILATOR DIMENSIONS
A A/2 B C D E F G H J K L M N P WT.
15 712 39 2612 8 2234 1138 1138 978 5 612 712 1678 8 25
18 9 4558 3058 1058 2634 1338 1338 11 578 814 9 1858 912 30 275#
20 10 49 3258 1014 2834 1438 1438 1138 8 918 10 1734 9 33
24 12 57 3838 1178 3312 1634 1634 1358 818 914 12 2112 11 3618 324#
30 15 7018 45916 1438 41 2012 2012 14 912 1158 16 2658 1138 4914
BE
M
A (THROAT)
P
H
G L
J
F
D
C
N
BIRD SCREEN
EXTERIOR FRAME
RAIN SHIELD
INTERIOR FRAME
SADDLE STRAP
SIDE
SKIRT
K
WELDED FRAME RIDGE VENTILATORS
NOTE: EXTERIOR AND INTERIOR FRAME MADE OF 18" X 1 12" X 1 12" ANGLE HOT-DIPPED GALVANIZED AFTER
WELDING. ALL OTHER PARTS MADE OF 22 GA. SHEET METAL, STANDARD WHITE OR GALVALUME.
8/13/2019 4.4Continuous Vents
6/16
Table of Capacities for Continuous Ventilators
CAPACITY:
To determine capacity per unit, multiply Base Rating by Temperature-Height Factor: CFM = Base x
Temperature-Height Factor
Based on fresh air intake area 11/2times ventilator throat area. Assumes 5 mph wind speed.
Temperature-Height FactorsTemperature Difference Base Ratings
Height 5 10 15 20 25 30 35 40 45 Size C.F.M.
10' .37 .49 .58 .64 .70 .76 .81 .86 .95 4" 1200
15' .42 .60 .71 .80 .86 .92 .99 1.05 1.09 9" 270020' .53 .70 .81 .92 .99 1.07 1.14 1.22 1.26 12" 3600
25' .58 .77 .89 1.00 1.08 1.18 1.25 1.33 1.39 15" 4500
30' .63 .83 .97 1.08 1.17 1.28 1.36 1.45 1.50 18" 5400
35' .66 .87 1.02 1.14 1.24 1.35 1.44 1.51 1.58 24" 7200
40' .70 .93 1.08 1.22 1.30 1.41 1.50 1.61 1.68 30" 9000
45' 74 96 1 12 1 28 1 38 1 48 1 59 1 68 1 75 36" 10800
MP
L o u v e r s V e n t i l a t o r s T r i m R o o f C u r b s S p e c i a l t y I t e m s
8/13/2019 4.4Continuous Vents
7/16
L o u v e r s V e n t i l a t o r s T r i m R o o f C u r b s S p e c i a l t y I t e m s
METALLIC PRODUCTS CONTINUOUS VENTILATORDESIGN EVALUATION AND CERTIFICATION
This is to certify that the construction of the Metallic Products 10ft. sections of ridge ventilators with 10ga. Base Straps, 24 ga. Baffles, and 26 ga. Sides, Ends, Skirts and Dampers will withstand wind loadsof 100 MPH when adequately supported by the roof panel to which it is attached. Minimum requiredattachment is No. 14 self tapping screw to the top of each major roof panel rib.
Wind load is determined in accordance with the MBMA Design Manual procedure. The following analysis
could be construed as Parts and Portions of the building structure, such as load supporting systems ofstructural roof panels, purlins, bracing, and framing.
The typical installation procedure for vents is to fasten each side skirt to the roof panel with a minimumof 1-#14 STS @ 12" o.c. (2 fasteners per linear foot of vent). Various Manufacturers test data has indicatedthat the resistance of these fasteners exceeds the design values used by Metallic Products by a factorin excess of 2 1/2 to 1. This design value is 50 lbs. pull out and 100 lbs. shear per fastener when installedin 26 ga. galvanized panels of 50,000 psi minimum yield stress.
The probable extreme standard condition would be a roof with mean height of 60 ft. and a slope between10 and 30 degrees (4/12 included).
1. Assume the clear distance at the ventilator between roof sheets to be 24" max. (This is probablygreater than would occur for a 12" throat vent.)
2. Assume total vent is in Z edge strip. Building would have to be at least 100 ft.wide and 25 ft.high at the eave.
3. Velocity Pressure q = 30.4 PSF (100 MPH) (Table 5.2b in the MBMA Low Rise Building SystemsManual)
8/13/2019 4.4Continuous Vents
8/16
Page 2
METALLIC PRODUCTS CONTINUOUS VENTILATORDESIGN EVALUATION AND CERTIFICATION
12" Standard Throat Ventilator: The 24 inch ridge opening results in 2 x 47.88 = 95.76 lbs. per ft. uplift onventilator or 47.88 lbs per fastener which is less than the 50 lbs. per fastener design stress. The ventilatoris less than 2 ft. high resulting in a shear stress of less than 50 lbs./fastener from an equal horizontal windload.
The building design used to create this wind loading exceeds the dimensional parameters of moststandard buildings offered by Metal Building Manufacturers. The location of the vent at the very end of
the building ridge (within the Z edge strip) is not unusual when continuous vents are used for the fullbuilding length. However, a more common arrangement is to place the vents, one in the center of eachbay or to begin the continous run, one ventilator back from the end wall peak.
Evaluation conducted by:_______________________________ May 7, 1997John M. Reynolds, P.E.
8/13/2019 4.4Continuous Vents
9/16
DATE:
TITLE:
PART:3306 Ella Blvd.
Houston, TX 77018(713) 688-6624 1-800-356-7746
E-mail: [email protected]
1/4/99FLASHING
WITHOUT DIE-FORMEDSKIRTS
CONTINUOUS VENT
DRAWING #2CV-01.6/ Rev. 03/00
END CAP OF VENT
DRAIN AT END OF VENT
CAULK HERE
POP RIVET END CAP TODRAIN ASSEMBLY
ROOF PANEL MAJOR RIB
END CAP OF VENT
DRAIN AT MULTI-UNITSPLICE (WEEP)
CAULK HERE
ROOF PANEL MAJOR RIB
NOTE:BREAK DRAIN ASSEMBLY TO FOLLOWEXACT SLOPE OF ROOF
END VIEW
SIDE
SKIRT
FASTENER
CLOSURE WITH SEALANT T&B
NOTES:BE SURE WEEPS ARE LEFT OPENFOR 5:12 AND UP ROOF PITCHES,THE TWO BOTTOM RIVETS MUST BEREMOVED BEFORE END SKIRT MAYBE PLACED ON VENT. REPLACE
RIVET WITH SCREW.
RIDGE VENT FLASHINGWITHOUT DIE-FORMED SKIRTS
8/13/2019 4.4Continuous Vents
10/16
DATE:
TITLE:
PART:3306 Ella Blvd.
Houston, TX 77018(713) 688-6624 1-800-356-7746
E-mail: [email protected]
END OF VENT DETAIL
CONTINUOUS VENTILATOR
DIE-FORMED SKIRT
END SKIRT DETAIL ANDCONTINUOUS VENT SPLICE
END CAP OF VENT
CV-01.7 / Rev. 03/00
END CAP OF VENT
CHANNEL
GUTTERTAPE SEAL
ROOF PANEL
GUTTER SUPPORT
CHANNEL SUPPORT
4/22/97
DIE-FORMEDSKIRT APPLICATION
CONTINUOUS VENT
VFSS-1
8/13/2019 4.4Continuous Vents
11/16
4/22/97
FLAT SKIRTAPPLICATION
CONTINUSOUS VENT
DATE:
TITLE:
PART:3306 Ella Blvd.
Houston, TX 77018(713) 688-6624 1-800-356-7746
E-mail: [email protected]
END OF VENT DETAIL
CLOSURE (Not by MP)
CONTINUOUS VENTILATOR
FLAT SKIRT
END SKIRT DETAIL ANDCONTINUOUS VENT SPLICE
CLOSURE (Not by MP)
END CAP OF VENT
DRAIN AT END OF VENT
CAULK HERE ROOF PANELMAJOR RIB
POP RIVET ENDCAP TO DRAINASSEMBLY
END CAP OF VENT
CAULK HERE
DRAIN AT MULTI-UNIT SPLICE
CV-01.8 / Rev. 03/00
ROOF PANELMAJOR RIB
8/13/2019 4.4Continuous Vents
12/16
DATE:
TITLE:
PART:3306 Ella Blvd.
Houston, TX 77018(713) 688-6624 1-800-356-7746
E-mail: [email protected]
1/04/99
INSTALLATION
DETAILS
FLAT SKIRT
CONTINUOUS VENT
CV-01.9 / Rev. 03/00
BIRD SCREEN
DAMPER GUIDE RODBAFFLE
RAIN SHIELDDAMPER
DAMPER SLIDELIFTER ARMSADDLE STRAPPIVOT BRACKET
SKIRTOPERATOR BAR
THROAT
END CAP
PUNCH MARKS
FIELD CUT
6:12
5:12
4:12
3:12
2:12
END CAP DETAILNOTE: DOTTED LINE INDICATES
FIELD CUT FOR 6:12 ROOFSLOPE. OTHER SLOPES
AS NOTED.
BLIND RIVETS (2) REQD
FOAM CLOSURE
END SKIRT
PEAK PANEL
ROOF PITCH LESS THAN 1:12 INSTALLATION:INSTALL END SKIRT FOR 1:12 ROOF SLOPE AND FOAM CLOSURE WITHTAPE SEALER TOP AND BOTTOM.
ROOF PITCH GREATER THAN 5:12 INSTALLATION:REMOVE TWO BOTTOM RIVETS BEFORE INSTALLING END SKIRT.REPLACE THE RIVETS WITH SHEETING SCREWS ONCE END SKIRT ISIN PLACE.
PULL BAR CONNECTION
DETAIL
RAIN SHIELDDAMPEREND CAP
LIFTER ARMGUIDE RODSPRING
PIVOT BRACKET & SADDLE STRAPPULL BAR
PULLEY AT FRAME OR END WALL
PULL BAR IN CLOSED POSITION
TO CLOSE DAMPER, PULL CABLE
2" TRAVEL
RAIN SHIELDDAMPER
END CAP
LIFTER ARMGUIDE RODSPRING
CHAIN CATCH (OPT.)
CHAIN WITH HANDLE
PIVOT BRACKET &SADDLE STRAP
PULL BAR
STANDARD CABLE OPERATION
OPTIONAL PULL CHAIN OPERATION(SINGLE UNITS ONLY)
PULL CHAIN MUST BEREMOVED FOR CONTINUOUSRUN OPERATION
L o u v e r s V e n t i l a t o r s T r i m R o o f C u r b s S p e c i a l t y I t e m s
8/13/2019 4.4Continuous Vents
13/16
CONTINUOUS VENT OPERATORSDRAWING VEW-1
DETAIL 3 - TYPE AOPERATOR #624 - HAND PULL-CABLE
35 ft. Plastic Coated Cable2 Cable ClampsI Chain Catch2 Pulleys
DETAIL 3 - TYPE BOPERATOR #634 - HAND PULL-CHAIN
35 ft. Chain2 PulleysI Chain Catch
DETAIL 3 - TYPE COPERATOR #618 - LEVER TYPE
40 ft. Cable2 Pulleys2 Cable ClampsI Lever HandleMounting & Installation Hardware
DETAIL 3 - TYPE DOPERATOR #632 - BOAT WINCH TYPE
60 ft. Cable2 Pulleys
OPERATOR #6161 Lever Handle Mounting Hardware
OPERATOR #619 - EXT.50 ft. Cable3 Eye Bolts
2 Cable Clamps
OPERATOR #634A10 ft. ChainI PulleyI Chain Catch
OPERATOR #634B4 ft. ChainI PulleyI Chain Hook
SINGLE UNIT OPERATOR FORMONOVENT
10 ft. Chain Installed
8/13/2019 4.4Continuous Vents
14/16
3306 Ella Blvd.
Houston, TX 77018(713) 688-6624 1-800-356-7746
E-mail: [email protected]
DATE:
TITLE:
PART:
OCT. 1, 1983
END WALL
INSTALLATION
CONTINUOUS VENT
VEW-1
OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER 3 UNITS MAX.
OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER 3 UNITS MAX.OPERATOR C: HAND LEVER TYPE 6 UNITS MAX.
OPERATOR D: BOAT WINCH TYPE 12 UNITS MAX.
CV-01.11 / Rev. 10/83
8/13/2019 4.4Continuous Vents
15/16
OCT. 1, 1983
SIDE WALL
INSTALLATION
CONTINUOUS VENT
VSW-1
3306 Ella Blvd.
Houston, TX 77018(713) 688-6624 1-800-356-7746
E-mail: [email protected]
DATE:
TITLE:
PART:
OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER 2 UNITS MAX.
OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER 2 UNITS MAX.
OPERATOR C: HAND LEVER TYPE 5 UNITS MAX.
OPERATOR D: BOAT WINCH TYPE 10 UNITS MAX.
CV-01.12 / Rev. 10/83
8/13/2019 4.4Continuous Vents