4
439 WOOD STREET EXISTING CONDITIONS OF TERRACOTTA FACADE

439 WOOD STREET EXISTING CONDITIONS OF TERRACOTTA … · • Install GFRC replacement masonry units • Patch and fill terracotta cracks with Elasto-mastic 352 and Elasto-fill 354;

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 439 WOOD STREET EXISTING CONDITIONS OF TERRACOTTA … · • Install GFRC replacement masonry units • Patch and fill terracotta cracks with Elasto-mastic 352 and Elasto-fill 354;

439 WOOD STREET EXISTING CONDITIONS OF TERRACOTTA FACADE

Page 2: 439 WOOD STREET EXISTING CONDITIONS OF TERRACOTTA … · • Install GFRC replacement masonry units • Patch and fill terracotta cracks with Elasto-mastic 352 and Elasto-fill 354;

5150 Penn AvePittsburgh PA 15224412.345.1999www.citystudiopgh.com

FACADE STABILIZATION

REVISIONS:

© COPYRIGHT 2019 citySTUDIO, LLCAll Rights Reserved. This drawing is an instrument of service, and is theproperty of citySTUDIO, and may not be reproduced or disclosed to thirdparties or any portion thereof without written authorization. Use of this drawingfor any project or owner other than the ones listed below, is expresslyprohibited without written authorization.

439 Wood St

PROJECT OWNER:Oren and Eiten Solomon5479 Pocussett StreetPittsburgh, PA 15217

PROJECT LOCATION:439 Wood StreetPittsburgh, PA 15222

REVIEW DRAWINGS

DATE ISSUED: May 10, 2019

NOT FOR CONSTRUCTION

439 WOOD STREETPITTSBURGH, PA 15222

A2.1EXISTING FACADE

ELEVATIONS,SECTION, DETAILS

EXISTING FRONT FACADE ELEVATIONScale: 1/4"=1'-0"1 FACADE SECTION

Scale: 1/4"=1'-0"2 FACADE ELEVATION DETAILSScale: 1"=1'-0"3 Remove and replace

Evaluate and remove as necessaryColor Key

3.3

3.2

3.1

A3.12

A2.13.3

A2.13.2

A2.13.1

REPAIR LOCATIONS AND SCOPE OF WORK • Remove indicated pieces and preserve pieces as able

• Evaluate and remove any other damaged masonry

• Clean and repair all steel that is accessible and protect exposed state with pre-catalyzed epoxy paint as able

• Replace missing and damaged sections of masonry cornice and point all joints in masonry cornice

• Replace front 20’ of roof with 60mil EPDM membrane and extend membrane to top of the parapet

• Cut all masonry joints for repointing and repoint with Type O mortar

• Install GFRC replacement masonry units

• Patch and fill terracotta cracks with Elasto-mastic 352 and Elasto-fill 354; clean terracotta surfaces with Prosoco Cleaner and rinse; coat all terracotta block with Elastowall 351

• Replace windows per separate scope