INSTALLATION NOTICE (INST2009-012)
PART NUMBER: 75015755 Main PCB Assembly PART NUMBER: 75015755 Main PCB Assembly
TOSHIBA LCD MODELS: 40XV645U, 46XV645U and 52XV645U TOSHIBA LCD MODELS: 40XV645U, 46XV645U and 52XV645U
NOTE: The following Installation Note must be followed in full when installing this replacement Main NOTE: The following Installation Note must be followed in full when installing this replacement Main PCB Assembly.
Part Number 75015755 is a direct replacement for the Main PCB Assembly used in models 40XV645U, 46XV645U and the 52XV645U. When replacing the 75015755 Main PCB Assembly, it’s necessary to confirm and/or set “panel options” and the “set ID” registers for the model you’re servicing. Enter the “service mode” and adjust the registers using the “Model to Data” chart provided below. Entering the Service Mode: (“Mute” > “Mute” > “Hold Mute” and press simultaneously the “Menu Button at the TV”)
1) Use the following sequence to enter the “Service Mode”. Press the “Mute” button on the user remote control three times holding the “Mute” button down on the third press. While holding down the “Mute” button on the remote, simultaneously press the “Menu” button on the TV receiver. (This button sequence must be completed relatively fast) The Service Mode will be displayed on the screen as shown in Figure 1.
2) Use the “Channel Up and Down” button to select the “Option Registers” and “Set ID Registers” indicated in the Model to Data Chart. Check the value settings for each of the registers shown for the model being serviced.
3) Use the “Volume Up and Down” to adjust registers to the values shown in the “Model to Data” Chart. 4) Save changes by powering the TV receiver to the off position. Momentarily remove AC power by removing the
AC line cord plug from the AC wall outlet. Reconnect AC line cord and power the TV receiver to the on position. Complete any necessary adjustments and safety checks as indicated in the service documentation.
Use the “Volume Up and Volume Down buttons to adjust registers to the values as shown in the “Model
to Data” Chart
Use the “Channel Up and Channel Down buttons to select
Option and Set ID Registers
Figure 1 “Model to Data” Chart
Model OPT1 (TV Option 1)
OPT2 (TV Option 2)
OPT3 (TV Option 3)
OPT4 (TV Option 4)
OPT5 TV Option 5)
SET-ID (Model ID)
40XV645U 00H 00H E0H 6EH 00H 8CH 46XV645U 00H 00H E0H 6AH 00H 8DH 52XV645U 00H 00H E0H 6BH 00H 8EH