2
2017.11.14 Product Highlights Stability Ultra small size Energy efficiency Protection Short circuit protection Over Voltage Protection Over Current Protection Safety Approvals Emissions CE CISPR 32 Class B Immunity EN55024/A1:2001 UOP340 UOP Series Open Frame Switching Power Supply 40W Series UL60950 CAN/CSA C22.2 NO. 60950 IEC 60950 UOP Series 2-1 Open Frame Switching Power Supply 40W Series Safety Certificate Reliability Guarantee Energy Saving LPS EMC Please contact our sales department for safety standard of each model.

40W UOP Series · 2018-03-27 · UOP Series Open Frame Switching Power Supply 40W Series UL60950 CAN/CSA C22.2 NO. 60950 IEC 60950 UOP Series Open Frame Switching Power Supply 40W

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 40W UOP Series · 2018-03-27 · UOP Series Open Frame Switching Power Supply 40W Series UL60950 CAN/CSA C22.2 NO. 60950 IEC 60950 UOP Series Open Frame Switching Power Supply 40W

2017.11.14

Product Highlights

Stability Ultra small sizeEnergy efficiency

Protection

Short circuit protectionOver Voltage ProtectionOver Current Protection

Safety Approvals

Emissions

CE CISPR 32 Class B

Immunity

EN55024/A1:2001

UOP340

UOP SeriesOpen Frame Switching Power Supply 40W Series

UL60950CAN/CSA C22.2 NO. 60950IEC 60950

UOP Series 2 - 1Open Frame Switching Power Supply 40W Series

Safety Certificate

Reliability Guarantee

EnergySaving LPS EMC

Please contact our sales department for safety standard of each model.

Page 2: 40W UOP Series · 2018-03-27 · UOP Series Open Frame Switching Power Supply 40W Series UL60950 CAN/CSA C22.2 NO. 60950 IEC 60950 UOP Series Open Frame Switching Power Supply 40W

2017.11.14

Typical model list

Line Load1 5V 5.0A ±5% 50mV 50mV 2% 10%2 5V 8.0A ±5% 50mV 50mV 2% 10%3 - - - - - - -

1. Mesurements shall be made with an oscilloscope with 20MHz bandwidth.2. Outputs shall be bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading.

RippleInput Condition DC Output Voltage

DC Output Current

Output Voltage

PrecisionNoises

RegulationOption/Remark

Measurement condition

UOP Series 2 - 2Open Frame Switching Power Supply 40W Series

Electrical Spec Absolute Maximum Rating

Min Typ Max Units90 100~240 264 VAC47 50/60 63 Hz

Input

DescriptionVoltageFrequency

Min Typ Max Units0 - 40 °C

-20 - 65 °C5 - 95 %RH5 - 95 %RH

Environmental

Operating Humidity No CondensingStorage Temperture Free Convection,Sea level

Free Convection,Sea levelOperating TemperatureDescription Comment

Comment

Storage Humidity No Condensing

Mechanical Spec

UOP340 Series