Use this drawing when: Deploying Motor Control Centers
in an existing structured network to provide simplicity and robustness.
D
C
B
A
D
C
B
A
4 3 2 1
4 3 2 1
Motor Control Center
(Cabling Subsystems 3-0)PCD0012-APRIL19-ENG
Motor Control Center (MCC) with DIN Rail Industrial Patch Panel Mounted in
Pathway, Enabling Ethernet Devices Across Multiple Sections
1 2 3 5 6 74
+ - + + --INP SEN OUT GND
MOD
NET
CHG
PWR
1
0
CON
8 9
10
UPSMaintenance-free No battery 24VDC
MCC’s were Ethernet-enabled by
means of industrial switches.
Due to the high noise and voltage
environment of the MCC, Panduit
presents the industrial DIN rail-
mounted 8 port patch panel
assembled with two loomed pre-
terminated cable bundles.
This innovative solution removes the
consideration for noise and voltage
by centrally locating the switch in an
Integrated Network Zone System,
Industrial Distribution Frame or
Micro Data center and enables a
structured infrastructure
deployment.
To Zone / IDF / MDC, see separate pages for more.
IndustrialNet Category 6A
Shielded 600V-Rated
Patch Cord
Use this drawing when: Deploying Motor Control Centers
in an existing structured network to provide simplicity and robustness.
D
C
B
A
4 3 2 1
D
C
B
A
4 3 2 1
Motor Control Center
(Cabling Subsystems 2-0)PCD0012-APRIL19-ENG
MODE
Catalyst 3750-X Series
BLANK
MODULEFN
SYSTCONSOLE XPS STAT SPEED DUPLX
S-PWR MAST STACK
Catalyst 3750-X Series
1 2 3 4 5 6 7 8 9 10 11 12
MODE
Catalyst 3750-X Series
BLANK
MODULEFN
SYSTCONSOLE XPS STAT SPEED DUPLX
S-PWR MAST STACK
Catalyst 3750-X Series
1 2 3 4 5 6 7 8 9 10 11 12
Smart-UPS
1 0 0 0
TestI
O
www.apcc.com
Catalyst 2960-S Series
49 50 51 52
MGMT
BASET
CONSOLE
37X
38X
47X
48X
37 38 39 40 41 42 43 44 45 46 47 48
25X
26X
35X
36X
25 26 27 28 29 30 31 32 33 34 35 36
13X
14X
23X
24X
13 14 15 16 17 18 19 20 21 22 23 241 2 3 4 5 6 7 8 9 10 11 12
PoE
STCK
SPED
DPLX
STAT
MSTR
RPS
SYST
MODE
1X
2X
11X
12X
11
12
23
24
12
13
14
11
12
23
24
12
13
14
UPS
Pre-Configured Industrial
Distribution Frame (IDF) is
engineered to deploy and protect
rack mount switches in industrial
applications, providing faster
installation times.
OM3 Indoor Fiber Cable
Wyr-Grid,
Electro Zinc plated
This page presents a Motor Control Center (MCC) deployment that isrouted back to a Industrial Distribution Frame (IDF), while also presenting three
options of cable routing.
1 2 3 5 6 74
+ - + + --INP SEN OUT GND
MOD
NET
CHG
PWR
1
0
CON
8 9
10
UPSMaintenance-free No battery 24VDC
Options for Cable Routing
Wyr-Grid
J-Pro Hooks
Conduit
IndustrialNet
8-Port DIN Mount
Copper Patch Panel
Grounding and Bonding
Mini-Com TX6A 10Gig
Shielded Jack Modules
Pre-configured MCC cable
bundle pre-terminated w/
RJ45 jack modules(Recommendation: If bundle
will be in close proximity to
power cables select a 600V
rated cable option.)
Use this drawing when: Deploying Motor Control Centers
in an existing structured network to provide simplicity and robustness.
D
C
B
A
4 3 2 1
D
C
B
A
4 3 2 1
Motor Control Center
(Cabling Subsystems 2-0)PCD0012-APRIL19-ENG
This page presents a Motor Control Center (MCC) deployment that isrouted back to a Network Zone System with two industrial switches, while also
presenting three options of cable routing.
24" x 36" Network Zone System
with industrial switches each with 2
1Gb MM fiber optic uplinks,
redundant 100-250Vac power
supply input and UPS pre-installed.
Wyr-Grid,Electro Zinc plated
1 2 3 5 6 74
+ - + + --INP SEN OUT GND
MOD
NET
CHG
PWR
1
0
CON
8 9
10
UPSMaintenance-free No battery 24VDC
Options for Cable Routing
Wyr-Grid
J-Pro Hooks
Conduit
12
34
56
78
91
01
11
21
31
41
51
61
71
81
92
02
12
22
32
4
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
+ + - -
24-28V
DCon
®
N LAC 100-240V
1606-XLE80E
1606-XLE
+ + - -
24-28V
DCon
®
N LAC 100-240V
1606-XLE80E
1606-XLE
+ + - -
24-28V
DC ok
®
N L
InputAC 100-240V
1606-XLS240E
1606-XLS
OVL
DC ok
+ -
!
TM
1
2
4
3 8
7
Tecnology
2
1 6
5
Con
sole
DC -Pwr B
DC +
Major Alarm
DC -Pwr A
DC +
Major Alarm
!
TM
1
2
4
3 8
7
Tecnology
2
1 6
5
Con
sole
DC -Pwr B
DC +
Major Alarm
DC -Pwr A
DC +
Major Alarm
IndustrialNet™
8-Port DIN Mount
Copper Patch Panel
OM3 Indoor Fiber Cable
Grounding and Bonding
Mini-Com TX6A 10Gig
Shielded Jack Modules
Pre-configured MCC cable
bundle pre-terminated w/
RJ45 jack modules(Recommendation: If bundle
will be in close proximity to
power cables select a 600V
rated cable option.)
Use this drawing when: Deploying Motor Control Centers
in an existing structured network to provide simplicity and robustness.
D
C
B
A
4 3 2 1
D
C
B
A
4 3 2 1
Motor Control Center
(Cabling Subsystems 3-0)PCD0012-APRIL19-ENG
Pre-configured Micro Data Center,
24 RU, includes two side panels,
network cabling, patch panels,
cable management, grounding,
casters, shock pallet and ramp
Panduit Wyr-Grid,
Electro Zinc plated
This page presents a Motor Control Center (MCC) deployment that isrouted back to a Micro Data Center (MDC), while also presenting three options of
cable routing.
1 2 3 5 6 74
+ - + + --INP SEN OUT GND
MOD
NET
CHG
PWR
1
0
CON
8 9
10
UPSMaintenance-free No battery 24VDC
Options for Cable Routing
Wyr-Grid
J-Pro Hooks
Conduit
IndustrialNet
8-Port DIN Mount
Copper Patch Panel
21
16
11
6
1
24
23
22
20
19
18
17
15
14
13
12
10
9
8
7
5
4
3
2
21
16
11
6
1
24
23
22
20
19
18
17
15
14
13
12
10
9
8
7
5
4
3
2
OUTPUT 30A
200-240V~
G(Hi-pot)
CIRCUITBREAKER200-240V~
20A
CIRCUITBREAKER200-240V~
20A
RO
O
OUTPUT 20A 200-240V~OUTPUT 20A 200-240V~
BATTERYCONNECTOR180V33A
OR
RS
232
CO
NT
AC
TS
RP
OB
AT
TE
RY
DE
TE
CT
ION
( )+ ( )-( )
OFF
ON
OFF
20
ON
20
NO
RM
AL
AC
SO
UR
CE
OU
TP
UT
OUTPUT
NORMAL AC SOURCE
1200W AC
1200W ACM
SS
PC
Ie 4
5
PC
Ie 5
PC
Ie 6
12
PC
Ie 1
PC
Ie 2
PC
Ie 3
1
2
PSU
MLOM
4321
MODE
Catalyst 3750-X Series
BLANK
MODULE1X
2X
11X
12X
13X
14X
FN
SYSTCONSOLE XPS STAT SPEED DUPLX
S-PWR MAST STACK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
HDMI HDMI
ee e e ee e e
AC
DC
AC
DC
MODE
Catalyst 3750-X Series
BLANK
MODULE1X
2X
11X
12X
13X
14X
FN
SYSTCONSOLE XPS STAT SPEED DUPLX
S-PWR MAST STACK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1200W AC
1200W ACM
SS
PC
Ie 4
5
PC
Ie 5
PC
Ie 6
12
PC
Ie 1
PC
Ie 2
PC
Ie 3
1
2
PSU
MLOM
4321
1200W AC
1200W ACM
SS
PC
Ie 4
5
PC
Ie 5
PC
Ie 6
12
PC
Ie 1
PC
Ie 2
PC
Ie 3
1
2
PSU
MLOM
4321
OM3 Indoor Fiber Cable
Mini-Com TX6A 10Gig
Shielded Jack Modules
Grounding and Bonding products
Pre-configured MCC cable
bundle pre-terminated w/
RJ45 jack modules(Recommendation: If bundle
will be in close proximity to
power cables select a 600V
rated cable option.)
For more information contact your local distributor, Panduit Sales Representative, or the Panduit Industrial Network Infrastructure team at [email protected].
Part Number Description
I4JPBJLU*Mortor control center cabling bundle system with Category 6A, 300V
plenum cable (PFP6X04)
I4KOTJLUX*Motor control center cabling bundle system with Category 6A, 600V, outdoor
cable (ISFCH6X04A)
CDPP8RGIndustrialNet, 8-port DIN rail mount patch panel. Includes screws to attach
faceplate and Ultimate ID labels and clear label covers.
CADIN1IG
Mini-Com DIN Rail Mount Adapter mounts to standard 35mm DIN rail and
accepts any single port Mini-Com Module, international gray. Includes a
label and label cover.
ISFCH6X04ATL-UGCopper Cable, Industrial, Category 6A 4-pair, 24/7 AWG Stranded, SF/UTP,
CMR, 600V rated, Oil Res., UV Res.,Teal
FOPPX12Y50um OM3 12 Fiber Indoor Armored Cable, Plenum (OFCP), 900um
buffered fibers
ISTPH6X2MTLPatch cord, IndustrialNet, Category 6A, shielded, 600V, RJ45 plug to RJ45
plug, teal, 2 meter.
CJS6X88TGYCategory 6A, RJ45, 10 Gb/s, 8-position, 8-wire universal shielded black
module with integral shield.
JP2SBC50-L20
J-Pro Cable support system, with screw-on beam clamp for use with
flanges up to 1/2 (12.7mm) thick, 2.00 (50.8mm) max. bundle capacity,
nylon 6.6 with metal attachments, black.
WG12BL10 12" W x 10' L Wyr-Grid pathway section
HLB2S-C0Tak-Ty hook & loop stacked strip cable tie, 7.0 (178mm) length, 0.75
(19.1mm) width, nylon loop, polyethylene hook, black
Z23**
Pre-Configured Network Zone System, 24" x 36", mild steel enclosure, for
two industrial switches, includes (16) Cat 6 UTP copper patch cords and
jacks, (4) MM LC fiber patch cords with (6) adaptors, backplane and cable
management.
ZDF48-RAPre-configured Industrial Distribution Frame enclosure ready for two
access and two distribution switches.
MDC***
Pre-Configured Micro Data Center, includes two side panels, network
cabling, patch panels, cable management, grounding, casters, shock
pallet and ramp.
For an expanded product offering visit panduit.com/networkpartsamerica or the online catalog at
panduit.com.
Motor Control Center
Cabling, Connectors and Pathways
Network Zone System, Industrial Distribution Center and Micro Data Center
**Network Zone Enclosures available in mild steel, stainless steel or sloped versions and various
levels of integration.
***Micro Data Centers available in 24 and 42 RU versions with various add-on kits.
*Motor Control Center Cable Bundles available in a variety of loom options, termination ends and
overwrap options.
Bill of Materials