19
User’s Guide 3M Ground Man Plus Workstation Monitor CTC334

3M Ground Man Plus Workstation Monitor CTC334documents.desco.com/PDF/TD-CTC334-T.pdfLe contrôleur pour station de travail Ground Man Plus est à la fois ... Contacter le centre de

  • Upload
    lenhi

  • View
    216

  • Download
    3

Embed Size (px)

Citation preview

User’s Guide

3M™ Ground Man Plus Workstation Monitor CTC334

2

Table of Contents

Section Page

Safety Information ................................................................................................3

1.0 Intended Use ................................................................................................3

2.0 Environmental Conditions ...........................................................................7

3.0 Package Contents ........................................................................................8

4.0 Description ..................................................................................................8

5.0 Installation .................................................................................................10

6.0 Enabling or Disabling Monitoring of Ground Lines .................................11

7.0 Setting Impedance Alarm Levels ..............................................................11

8.0 Verification Check .....................................................................................12

9.0 Operations .................................................................................................13

10.0 Accessory Items ........................................................................................14

11.0 Maintenance ..............................................................................................14

12.0 Customer and Technical Service ...............................................................15

13.0 Regulatory Information .............................................................................15

3

1.0 Safety InformationPlease read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future reference.

Intended UseThe 3M™ Ground Man Plus Workstation Monitor CTC334 is intended for use by electrical assembly personnel to monitor ground impedance for process and equipment tools.

The Ground Man Plus Workstation Monitor CTC334 is both a wrist strap monitor and a ground monitor. It provides operator grounding, and can be used at work areas or locations to monitor the ground impedance of process tools in semiconductors, disk drives, flat panels, and EMS and other environments. Ground impedance monitoring can be used for up to three points for metal grounds within a tool. The Ground Man Plus Workstation Monitor CTC334 can also be used to monitor the resistance to ground and voltage level on a person. The units incorporate green and red LEDs and audible alarms.

The systems must be installed as specified in the user’s guide in an indoor commercial/industrial environment, and have not been evaluated for other uses or locations. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Explanation of Signal Word Consequences

WARNING Indicates a hazardous situation which, if not avoided, could result in

death or serious injury.

CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury and/or property damage.

NOTICE Indicates a situation which, if not avoided, could result in property damage.

4

WARNING

To reduce the risks associated with hazardous voltage and fire:• Do not use the power supply if damaged. Do not modify or attempt to service the power supply.

Contact 3M authorized service center for replacement.• Replace power supply if damaged using only 3M supplied parts.• Do not attempt to service the 3M™ Ground Man Plus Workstation Monitor CTC334, there are no

user serviceable parts; Return to 3M for service.• Do not position the Ground Man Plus Workstation Monitor CTC334 accessories or other equipment

where unplugging the power supply is difficult.

• Always locate the power source (socket or outlet) near the equipment. The power supply plug serves as the disconnect device.

• Do not use the Ground Man Plus Workstation Monitor CTC334 or its power supply outdoors or wet/humid environments.

• Do not use the Ground Man Plus Workstation Monitor CTC334 or its power supply outside of the operating conditions listed in this user guide.

• Use only a dry cloth when cleaning.

To reduce the risks associated with hazardous voltage:• Use only the power supply provided by 3M and specified for the country of use.• Before installing the Ground Man Plus Workstation Monitor CTC334 for use with any equipment,

make sure that the Monitor is properly grounded.

To reduce the risks associated with medical device malfunction:• Persons with heart pacemaker devices should never use this Ground Man Plus Workstation Monitor

CTC334.

Explanation of Symbols

Ground Double insulation

Direct Current Terminal

Caution For Indoor Use Only

To reduce the risks associated with environmental contamination:• Dispose of Monitor and Power Supply in accordance with all applicable local and government

regulations.

CAUTION

5

1.0 Consignes de sécuritéVeuillez lire, comprendre et suivre toutes les consignes de sécurité figurant dans les présentes instructions avant d’utiliser ce dispositif. Conserver ces instructions afin de pouvoir les consulter ultérieurement.

Usage prévuLe contrôleur pour station de travail Ground Man Plus de 3M™ est conçu pour être utilisé par le personnel de montage électrique et pour surveiller l’impédance de terre des outils de processus et d’équipement.

Le contrôleur pour station de travail Ground Man Plus est à la fois un moniteur de bracelets et un moniteur de terre. Il assure la liaison à la terre de l’opérateur et peut être utilisé dans les salles ou stations de travail afin de surveiller l’impédance de terre des outils de processus pour semi-conducteurs, lecteurs de disques durs, écrans plats, SEM et autres environnements. La surveillance de l’impédance de terre peut être utilisée pour trois points maximum de masses métalliques dans un même outil. Le contrôleur pour station de travail Ground Man Plus peut également être utilisé pour surveiller la résistance à la masse et le niveau de tension d’une personne. Les unités disposent de DEL vertes et rouges, ainsi que d’alarmes sonores.

Les systèmes doivent être installés, tel qu’indiqué dans le guide de l’utilisateur, à l’intérieur d’un environnement commercial/industriel. Les autres usages ou environnements n’ont pas été évalués. Si l’équipement est utilisé d’une manière non spécifiée par le fabricant, cela peut compromettre la protection assurée par l’équipement.

Explication des mots de mise en garde et de leurs conséquences

AVERTISSEMENT Indique une situation dangereuse, qui si elle n’est pas évitée, peut

entraîner la mort ou des blessures graves.

ATTENTION Indique une situation dangereuse, qui si elle n’est pas évitée, peut entraîner des blessures légères ou de gravité modérée et/ou endommager l’équipement.

MISE EN GARDE Indique une situation, qui si elle n’est pas évitée, peut endommager l’équipement.

6

AVERTISSEMENT

Pour réduire les risques associés aux incendies et tensions dangereuses : • Ne pas utiliser l’alimentation électrique si elle est endommagée. Ne pas modifier ou tenter

de réparer l’alimentation électrique. Contacter le centre de réparation agréé 3M pour la faire remplacer.

• Remplacer l’alimentation électrique en cas de dommage à l’aide de composants fournis par 3M uniquement.

• Ne pas tenter de réparer le contrôleur pour station de travail Ground Man 3M™, car il ne comporte aucune pièce réparable par l’utilisateur ; renvoyer à 3M pour réparation.

• Ne pas placer les accessoires du contrôleur pour station de travail Ground Man Plus ou d’autres équipements susceptibles de gêner le débranchement de l’alimentation électrique.

• Toujours placer l’alimentation électrique (prise ou fiche) près de l’équipement. La fiche de l’alimentation électrique permet de déconnecter le dispositif.

• Ne pas utiliser le contrôleur de station de travail Ground Man Plus ou son alimentation électrique à l’extérieur ou dans les environnements humides.

• Ne pas utiliser le contrôleur de station de travail Ground Man Plus ou son alimentation électrique en dehors des conditions d’exploitations figurant dans le présent guide d’utilisation.

• Nettoyer le système à l’aide d’un chiffon sec.

Pour réduire les risques associés aux tensions dangereuses :• Utiliser uniquement l’alimentation électrique fournie par 3M et spécifiée pour le pays

correspondant.• Avant d’installer le contrôleur de station de travail Ground Man Plus en vue de son utilisation avec

d’autres équipements, vérifier que le contrôleur est correctement mis à la terre.

Pour réduire les risques associés aux dysfonctionnements de dispositifs médicaux :• Les personnes portant un stimulateur cardiaque ne doivent jamais utiliser le contrôleur de station

de travail Ground Man Plus.

Explication des symboles

Mise à la terre Double isolation

Courant direct Borne

Attention Réservé à un usage en intérieur

Pour réduire les risques associés aux contaminations environnementales :• Mettre le contrôleur et son alimentation électrique au rebut conformément à l’ensemble des

réglementations locales et gouvernementales en vigueur.

ATTENTION

7

To reduce the risk of damage to components or assemblies being handled:• 3M™ Ground Man Plus Workstation Monitor CTC334 must be checked periodically to verify each test

mode is functioning correctly.• Ensure proper operation of Ground Man Plus Workstation Monitor CTC334 by performing operational

verification test as required.• Always properly ground your tools, equipment, and dissipative surfaces to known good ground

before connecting Ground Man Plus Workstation Monitor CTC334s for monitoring.

NOTICE

Pour réduire le risque d’endommagement des composants ou ensembles manipulés :• Le contrôleur de station de travail Ground Man Plus de 3M™ doit être régulièrement contrôlé, afin de

vérifier que chaque mode de test fonctionne correctement.• Assurer le bon fonctionnement du contrôleur de station de travail Ground Man Plus en effectuant les

tests de vérification du fonctionnement requis.• Toujours correctement relier vos outils, équipements et surfaces dissipatives à une prise de terre

fonctionnelle avant de brancher le contrôleur de station de travail Ground Man Plus et de lancer la surveillance.

MISE EN GARDE

2.0 Environmental ConditionsThis equipment has been tested and found to be safe to operate within these environmental conditions:• This is not a warranty of equipment performance within these conditions.• Indoor use only• Ingress Protection: IPX0• Altitude: Up to 2,000 m• Mains supply voltage fluctuations up to ± 10% of the nominal voltage.• Transient overvoltages up to the levels of overvoltage category II.• Temporary overvoltages occurring on mains supply.• Pollution degree 2.• Temperature: Maximum 110°F / 43°C Minimum 50°F / 10°C• Humidity: Maximum relative humidity 80% for temperatures up to 31°C

decreasing linearly to 50% relative humidity at 40°C .

8

3.0 Package ContentsYour 3M™ Ground Man Plus Workstation Monitor CTC334 package should include the following:

3M™ Ground Man Plus Workstation Monitor CTC334 unit 1 ea.

AC/DC Power Adapter 1 ea.

User’s Guide 1 ea.

General ProductIf any of the items are missing, please contact 3M, 1-866-722-3736, or one of 3M authorized distributors immediately.

Power Supply Universal 100 - 240VAC, 0.5A, ~ 50 - 60HzOutput: 12VDC, 1.5A

Dimension (approx.) 2.4” W x 0.85” H x 2.6” D(61 mm W x 21 mm H x 66 mm D)

Weight (approx.) 75g

4.0 DescriptionOverviewThe 3M™ Ground Man Plus Workstation Monitor CTC334 can be used at work areas or locations to monitor the ground impedance of process tools including, but not limited to semiconductor, disk drive and flat panel environments. Ground impedance monitoring can be used for up to three points for metal ground within a tool. The Ground Man Plus Workstation Monitor CTC334 can also be used to monitor the resistance to ground and voltage level on a person. The unit incorporates green and red LEDs and audible alarms.

Ground Impedance Monitor Continuously monitors for ground impedance on three separate channels that are connected to three process tools. The alarm level is set the same for all channels.

Output Signal An output signal is available for connecting to the tool’s computer or PLC. The 5V signal is either logic 1 or 0 for indicating the monitored ground resistance/impedance conditions and for the wrist strap.

9

Voltage on Person Wrist Strap Monitor The Ground Man Plus Workstation Monitor CTC334 has a feature that allows continuous monitoring of voltage on a person through a dual conductor wrist band assembly.

PerformanceImpedance Alarm Level The alarm level can be preset from 1 to 20 ohms (from 1 to 10 ohms in increments of 1 ohm and from 10 to 20 ohms in increments of 2 ohms) by selecting through a combination of LED patterns indicated on the front on the unit. All three monitoring lines are set to the same selected impedance value. If the measured impedance on a line is lower than the setting, a green LED will remain illuminated for that line(s). If the impedance is higher than the preset level, a red LED and audible alarm are activated for that line(s). If the impedance level remains above the preset alarm level, the red LED and audible sound remains on.

The 3M™ Ground Man Plus Workstation Monitor CTC334 only monitors proper connection to ground. The monitored equipment must be properly ground by itself. A wire must be attached from the Ground Man Plus Workstation Monitor CTC334 (GND terminals) to approved ground points to monitor grounding of process tools correctly.

Output Signal Level The output connector provides a logic 1 (+5V) when all grounds are within limits and the unit is powered on. If any of the monitored grounds fail, a wrist strap fails, or power to the unit is lost, the output is logic 0 (0V).

Person Voltage and Resistance MonitorThe alarm level is monitored when a person is wearing a dual conductor wrist strap assembly and plugged into the front jack. There is a short hold on the body voltage alarm so that it is not missed. The unit will respond to either positive or negative voltage. The alarm is also activated when the wrist band is worn too loosely and the loop resistance level is exceeded. The red LED indicates an over the resistance limit without a voltage being generated on the person at the same time. The green LED indicates proper connection of operator. A green LED plus blinking red LED will indicate if there is a body voltage generated; operator may still be connected properly. The green LED is off when a dual conductor ground cord is not plugged into the jack.

10

Enabling and Disabling Audible AlarmThe audible alarm can be enabled or disabled by momentarily pressing a recessed miniature push-button Set switch located on the back of the unit while the monitor is powered on. Use a pin to press the switch.

5.0 InstallationWire AttachmentThe AC adapter should not be connected during the wire attachment process. Attach 18 AWG wires to the unit as described below. Strip vinyl insulation at each end of the wires to approximately 1/3 in. (8 mm). Twist the stranded wire on each end before inserting wire into each connector location.

Attach ground wire to the GND connector on the back of the unit. Insert a small blade screw driver into the orange slot above. Push inward and insert the stripped wire fully into the hole in the green connector. Hold wire fully in and release the screw driver to allow the wire to catch.

If you are planning to use the 3M™ Ground Man Plus Workstation Monitor CTC334 output to the tool, attach wire to the Out connector on back of unit. Insert the wire as described above.

Attach the impedance monitor wire(s) to the chosen ground line(s) G1, G2, G3 connector(s) on back of unit. Insert the wire as described above.

AC/DC Adapter ConnectionConnect the circular plug of the AC/DC Adapter into the power jack on the back of the unit.

MountingDetermine the mounting location of the Ground Man Plus Workstation Monitor CTC334. Attach the unit using one of the following recommended methods:• Screws• 3M™ Dual Lock™ Fastener

11

6.0 Enabling or Disabling Monitoring of Ground LinesSometimes not all three ground points in the tool need to be monitored. This procedure will set up the number of ground lines (G1, G2, G3) that will be used, so that there is no need to put jumpers or shunts on the unused ground monitoring inputs. The AC Adapter should not be plugged in at this moment.

Attach GND line to known good ground.Attach monitor line(s) (G1, G2, G3) to ground that has been determined to use. Do not plug any wires into those ground monitor inputs that will be unused.

Press and hold the Set button using a pin. While the button is pressed inward, plug in the AC Adapter and then release the Set button.

Wait then for approximately 30 seconds. The 3M™ Ground Man Plus Workstation Monitor CTC334s will beep during this time. After this time, the monitors will produce one beep and will automatically disable the lines to which nothing was connected. This procedure can be repeated whenever a change in the number of ground lines being monitored is required.

Enabling and Disabling Audible Alarm The audible alarm can be enabled or disabled by momentarily pressing a recessed miniature push button Set switch located on the back of the unit while the monitor is powered on. Use a paper clip to press the switch.

7.0 Setting Impedance Alarm LevelsBy default, the Ground Man Plus Workstation Monitor CTC334 factory set to a 10 ohms alarm level.

If this specification needs to be changed, the following procedure sets the impedance alarm level for all channels (G1, G2, G3).

Repeat the steps above in Section 4.0.

Right after the beeps stop; continue pressing the Set button until the impedance level is matched as shown in the table on the next page.

When the beeping stops, the four left-most LEDs (as shown in the photo on next page) allow for setting of resistance value. G1 & G2 red LEDs are upper location and G1 & G2 green LEDs are lower. Select the ground impedance value by pressing the Set button to advance the resistance limit. Turn the LEDs on or off as indicated in the table on the next page.

12

Not pressing the Set switch for about seven seconds after selecting causes the limit value to be saved and normal operation started.

Using LED’s on Front of Unit to Set Resistance Alarm Level

Resistance Ohms LED Resistance Ohms LED

1 9

2 10

3 11

4 12

5 14

6 16

7 20

8

8.0 Verification CheckVerification of G1, G2 and G3 monitoring.1. Prepare the 3M™ Workstation Monitor Checker CTE701A.2. Disconnect the wire connected to G1, G2 and G33. Connect the ground input of the checker to the ground connector of the 3M™

Ground Man Plus Workstation Monitor CTC334. Set the checker to a proper resistance alarm level (see the Workstation Monitor Checker CTE701A User’s Guide).

4. Connect the red wire tip of the checker to the device terminal (G1, G2 and G3)

5. Press the Metal Ground Fail button on the checker. The red LED of either G1, G2 or G3 should remain on.

6. Press the Metal Ground Pass button on the checker. The green LED of either G1,G2 or G3 should turn green.

7. Repeat these steps for all enabled ground monitoring inputs.

13

9.0 OperationsGround Impedance MonitorConnect the ground wire to an electrical known good ground point.

Connect the output wire to the tool, if you intend to use it; otherwise leave it open.

Connect the ground monitor inputs to identified locations in a process tool or several pieces of other equipment. Make sure to connect the monitoring inputs to different physical locations than those points used for their grounding.

Person Voltage and Resistance MonitorThis is a feature of the 3M™ Ground Man Plus Workstation Monitor CTC334. Plug the dual conductor ground cord of the wrist strap into the jack on the front of the unit. If the wrist strap is worn properly, a green LED will come on; otherwise the red LED will be on. In order to provide good ground connection, the wrist strap must be worn tightly and the green light on the Ground Man Plus Workstation Monitor CTC334 is an indication of that.

If, for some reason, while properly connected, the operator develops excessive body voltage (in excess of ± 2.5V in any polarity), the green LED may still be on, but the red LED will blink and the alarm sound will be on. No LED is on if a dual conductor ground cord is not plugged into the jack.

14

Connecting the 3M™ Ground Man Plus Workstation Monitor CTC334

10.0 Accessory Items

3M Product No. Description

2368 3M™ Dual Conductor Fabric Wrist Band, Adjustable

2360 3M™ Dual Conductor Ground Cord, Coiled, 5 ft.

2370 3M™ Dual Conductor Ground Cord, Coiled, 10 ft.

CTE701A 3M™ Workstation Monitor Checker

11.0 MaintenanceProcedures for Cleaning and DecontaminationUnplug power from the device. Clean using a dry brush or lint free cloth around the device. In case of contact malfunction, clean contacts using a contact cleaner or a brush and tighten all connections. Plug in the power.

Repairs and ServicingDo not attempt to repair the product yourself. Contact a 3M sales representative or authorized dealer to request inspection and repair. Replace power supply if damaged using only 3M supplied parts. Other than replacement of remote jacks, do not attempt to service the device. There are no user-serviceable parts.

Facility ground baror other good

Output can go to the PLC of the tool to stop it when any of the grounds fail or to turn on the light tower

Up to three ground monitoring points(G1, G2, G3) can monitor the different parts of the tool

15

Device CalibrationContact a 3M sales representative or authorized dealer to request for product calibration if needed.

12.0 Customer and Technical ServiceFor more technical information, call the 3M Electronics Materials Solutions Division Technical Service Help Line: 866-722-3736 or contact the local 3M Technical Service.

13.0 Regulatory InformationFCCThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are de-signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

WEEE StatementThe following information is only for EU-members States: The mark shown to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002/96/EC (WEEE). The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste, but use the return and collection systems according to local law.

cULus StatementMeets cULus requirements. CE StatementMeets CE (European Confomity) requirements.

ICES StatementThis Class A digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe A est conforme à la NMB-003 du Canada.

16

China RoHSElectronic Industry Standard of the People’s Republic of China, SJ/T11363-2006, Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products.

This symbol, per Marking for the Control of Pollution Caused by Electronic Information Products, SJ/T11364-2006, means that the product or part does contain a substance, as detailed in the chart below, in excess of the following maximum concentration values in any homogeneous material: (a) 0.1% (by weight) for lead, mercury, hexavalent chromium, polybrominated biphenyls or polybrominated diphenyl ethers; or (b) 0.01% (by weight) for cadmium. Unless otherwise stated by 3M in writing, this information represents 3M’s best knowledge and belief based upon information provided by third party suppliers to 3M.

Name and Content of Hazardous Substances or Elements

Part or Component NameHazardous Substances or Elements

(Pb) (Hg) (Cd) (Cr (VI) (PBB) (PBDE)

Termination in capacitor 0603

Solder in diode

Finish in diode

Terminations in PCBs

Terminations in resistors 0603

Plating in resistors 0603

Resistor ink in potentiometer

Solder in instrument

Solder in IC

Solder in buzzer

Audio jack

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

O: Indicates that this hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in the SJ/T11363-2006.X: Indicates that this hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in the SJ/T11363-2006.

17

ACPEIPNorme d’industrie électronique de la République populaire de Chine, SJ/T11363-2006, Exigences relatives aux limites de concentration de certaines substances dangereuses contenues dans les produits d’information électronique.

Ce symbole, repère du Contrôle de la pollution causée par les produits d’information électronique, SJ/T11364-2006, signifie que le produit ou l’un de ses composants contient une substance, figurant dans le tableau ci-dessous, dans une quantité excédant les valeurs de concentration maximales suivantes dans un matériau homogène : (a) 0,1 % (du poids) pour le plomb, le mercure, le chrome hexavalent, les polybromobiphényles ou les polybromodiphényléthers ; ou (b) 0,01 % (du poids) pour le cadmium. Sauf indication écrite contraire de 3M, ces informations sont fondées sur les meilleures connaissances et hypothèses de 3M, ainsi que sur des informations fournies par les tiers fournisseurs de 3M.

Nom et composition des substances ou éléments dangereux

Nom de la pièce ou du composantSubstances ou éléments dangereux

(Pb) (Hg) (Cd) (Cr (VI) (PBB) (PBDE)

Borne de condensateur 0603

Soudure de la diode

Terminaison de la diode

Bornes en PCB

Bornes de résistances 0603

Revêtement métallique de résistances 0603

Encre de résistance de potentiomètre

Soudure de l’instrument

Soudure de CI

Soudure de vibreur

Prise jack audio

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

O : indique que la quantité de cette substance dangereuse contenue dans tous les matériaux homogènes de cette pièce est inférieure aux limites définies dans la SJ/T11363-2006.X : indique que la quantité de cette substance dangereuse contenue dans tous les matériaux homogènes de cette pièce est supérieure aux limites définies dans la SJ/T11363-2006.

1817

产品中有毒有害物质或元素的名称及含量

部件名称有毒有害物质或元素

铅 汞 镉 六价铬 多溴联苯 多溴二苯醚

0603电容引脚

二极管焊接部

二极管电镀

印刷电路板焊盘/安装孔

0603 电阻引脚

0603 电阻电镀部

电位器中的电阻油墨

装置的焊接部

IC焊接部

蜂鸣器焊接部

音频插孔

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

X O O O O O

O: 表示该有毒有害物质在该部件所有均质材料中的含量均在SJ/T11363-2006 标准规定的限量要求以下。X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T11363-2006 标准规定的限量要求。

3

Electronics Materials Solutions DivisionStatic Control Products926 JR Industrial DriveSanford, NC 27332-9733Toll-Free: 866-722-3736International: 919-718-0000Email: [email protected]

Please recycle. Printed in USA.© 3M 2014. All rights reserved.78-9100-3253-7B JHA

Important NoticeAll statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M.

Warranty; Limited Remedy; Limited Liability.This product will be free from defects in material and manufacture for one year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted.

3M and Dual Lock are a trademarks of 3M Company.