3M Bonding Systems Division
Adhesives for Electronics
Reliability Study of Sub 100 Micron Pitch, Flex-to-ITO/glass Interconnection, Bonded with an Anisotropic Conductive Film.
Cameron T. Murray, Peter B. Hogerton, Theary Chheang, Robert L. Rudman
3M Company Bonding Systems Division, 230-2E-11, St. Paul, MN 55144
3M Bonding Systems Division
Z-Axis/ Anisotropic Conductivity
Conductivity inthe Z direction only(through the thicknessof the adhesive)
Z
3M Bonding Systems Division
Flex to ITO Bonding
Copper traceZAF ITO Trace
Glass
Flex Circuit
LCD
Polymer particle preferred with ITO traces
3M Bonding Systems Division
Cellular Phone Applications for ZAF
• Flex to ITO glass
– 5000 series - specific product depending upon pitch
• Flex to PCB
– 7303 or 5000 series depending upon pitch
3M Bonding Systems Division
Making Reliable Bonds
• Proper thermocompression bonding technique
– Flex alignment to ITO/glass or PCB
– Proper thermal cure profile
– Proper pressure
• Proper overlap area
– guaranteed minimum number of particles (to provide low electrical resistance)
• Proper pitch
– minimum space between traces to avoid shorting
3M Bonding Systems Division
Thermocompression Bonding
ITO Glass
BondingThermode
Applied pressure
Flex Circuit
Z-Axis ConductiveFilm
Compliantlayer
3M Bonding Systems Division
Pressure Uniformity
Bonding Stage
Thermode
Pressure Senisitive Paper(Prescale Film)
3M Bonding Systems Division
Temperature Profile
ITO Glass
BondingThermode
Ram pressure
Flex Circuit
Thermocouple
Compliantlayer
380C/3.9s 285C/16.2s
0
20
40
60
80
100
120
140
160
180
200
0 5 10 15 20 25 30seconds
de
gC
3M Bonding Systems Division
Overlap Area
Copper traceZAF ITO Trace
Glass
Flex Circuit
LCD
Overlap Area = ZAF width x Trace width
3M Bonding Systems Division
Overlap Area
0.01
0.1
1
10
0 20000 40000 60000 80000 100000
5552R Resistance vs. Overlap areaR
esis
tanc
e (o
hm
s)
High
Low
Average
Overlap Area (microns2)
3M Bonding Systems Division
Particle Count
0
50
100
150
200
250
0 20000 40000 60000 80000 100000
5552R Particle Count vs. Overlap AreaP
artic
le C
ount
Overlap Area (microns2)
Reliaiblity minimum = 20 pac men
High
Low
Average
3M recommendedmimimum overlap area
Safe Zone
3M Bonding Systems Division
Reliability Study
• Fine Pitch Flex bonded to ITO/Glass (10 /square)
– 80, 100 micron pitch
– 285 interconnections per condition
– Peel Testing and Electrical Resistance
• Environmental Testing Conditions
• 100 C for 1024 hours
• 125 C for 1025 hours
• 60 C / 95 % RH for 1029 hours
• -40 C to 100 C Thermal cycle (1 hour/cycle) for 1029 cycles
• -55 C to 125 C for 1820 cycles - Thermal shock
• 85 C and 85 % RH for 1028 hours
3M Bonding Systems Division
Thermocompression Bonder
Thermode
Compliant layer
Circuitry
3M Bonding Systems Division
Temperature Profile
380C/3.9s 285C/16.2s
0
20
40
60
80
100
120
140
160
180
200
0 5 10 15 20 25 30seconds
de
gC
3M Bonding Systems Division
LCD Visual Inspection
3M ZAF flow front after bonding
Thermodefootprint - inspectin this region.
LCD Display Area
ITO trace
3M Bonding Systems Division
Proper Bond Formation
Flex Circuit
ITO/glass
Flex Circuit
ITO/glass
ZAF
ZAF
Case 1: Fillet formed and shorts observed
Case 2: No fillet formed and no shorts observed
Fillet
3M Bonding Systems Division
Particle Compression - Top
ShapeA
3M Bonding Systems Division
Particle Compression - Side
3M Bonding Systems Division
4 Wire Resistance Test
• Test designed to subtract out the resistance of the copper traces and the ITO glass:
– Requires specialized flexible circuit design
– Automated testing jig/ computer data collection
– 57 measurements per sample / 5 samples per condition
– Microvoltmeter and power supply
• Test limitations
– Perfect circuit design not possible - measured resistance is influenced by ITO resistance
– Samples must be removed from the environment for testing
3M Bonding Systems Division
4 Wire Test Circuit
Test Pads
Circuit Traces
3M Bonding Systems Division
4 Wire Test Pads
PowerSupply
Voltmeter
3M Bonding Systems Division
100 Micron Reliability
0
5
10
15
20
25
018
535
352
068
885
610
24
018
735
452
268
985
710
25
056
112
168
224
1029
032
082
013
2018
20
019
035
852
569
386
010
29
018
935
752
469
286
010
28
5552R Resistance Stability
B
Res
ista
nce
(o
hm
s)
Hours HoursHours Cycles Cycles Hours
125 C-40 to
+ 100 C-55 to
+ 125 C60 C /
95 % RH85 C/
85 %RH100 C
100 micron
3M Bonding Systems Division
80 Micron Reliability
0
5
10
15
20
018
535
352
068
885
61
024 0
187
354
522
689
857
102
5 0 56 112
168
224
102
9 032
082
01
320
182
0 019
035
852
569
386
01
029 0
189
357
524
692
860
102
8
5552R 80 micron pitch
B
Re
sis
tan
ce
(o
hm
s)
Hours HoursHours Cycles Cycles Hours
125 C-40 to
+ 100 C-55 to
+ 125 C 60 C / 95 % RH 85 C/ 85 %RH100 C
3M Bonding Systems Division
Peel Test
• IPC TM-650 2.4.9.1
– 2.5 mm / min peel rate
– 90 degree angle
• Reported values = maximum value on plot
• Peel testing performed at the conclusion of environmental aging
• 5 peeled parts per environmental condition
3M Bonding Systems Division
Typical Peel Test
0
2
4
6
8
10
12
14
0
200
400
600
800
1000
1200
1400
0 500 1000 1500 2000 2500 3000 3500 4000
90 Degree Peel
Pee
l Stre
ngth
(N)
Peel S
trength (grams)
Distance (microns)2.5 mm/min
3M Bonding Systems Division
Peel Reliability
0
250
500
750
1000
1250
1500
Init
ial
10
0C
dry
12
5C
dry
-4
0C
/10
0C
-5
5C
/12
5C
60
C/9
5%
RH
85
C/8
5%
RH
Init
ial
10
0C
dry
12
5C
dry
-4
0C
/10
0C
-5
5C
/12
5C
60
C/9
5%
RH
85
C/8
5%
RH
Pe
el A
dh
es
ion
(g
/cm
)
Pee
l Ad
he
sion
(N/cm
)
15
0
10
5
80 100 m m
3M Bonding Systems Division
Shorting Test
• Flex with 30 micron gap bonded to non-conductive glass
• Initially shorts found - related to fillet formation over edge of ITO glass
• 128 flex samples remade with proper bonding
• 12,800 gaps measured with no shorts
Flex Circuit
ITO/glass
Flex Circuit
ITO/glass
ZAF
ZAF
Case 1: Fillet formed and shorts observed
Case 2: No fillet formed and no shorts observed
Fillet
3M Bonding Systems Division
Conclusions
• Fine pitch circuitry can be bonded with Z-Axis Films into a highly reliable interconnection
• Proper bonding conditions and equipment are important when making a reliable bond
– proper placement of ZAF to prevent shorting
– proper particle compression
– proper thermal profile for good mechanical (peel) performance
• Visual inspection combined with electrical and peel testing are important tools in monitoring process control