Upload
sebinxavier
View
217
Download
0
Embed Size (px)
Citation preview
8/3/2019 3g Quality Checklist Ti Ver-001
1/2
Site ID: Dated:
Site Name: Auditor:
Subcon: PTID
Audit
ResultScore Resp.
OK /
NG
Subcon/
NSN
2-5103
5013 Si te clear of any hazardous substances (or under cont ro lled storage) 2
5102Personal Protective Equipment "PPE" (helmet, harness, etc.) on siteand used when necessary 1
5501-5602
5501 Site Folder on site 4
5509 Site integration checklist completed 4
5510 Commissioning tests passed according to specification 2
5513 All microw ave installation data entered into the site folder 3
5514
All microwave commi ssioning data and results entered into the site
folder and all tests passed 3
5602
No visible damage to im plementation equ ipment (e.g. scratch, broken
part) 3
1-6021
6001 Cabinet installed according to specifications 2
6002 Cover doors and locks properly adjusted 3
6003 Cable entry kits / bridging kits and sealing installed correctly 3
6006 Plinth air guide installation done correct ly 3
6012
Int ernal Plug-in unit / Modules installed correctly and to Project /
customer configuration 2
6018 Spare mater ial l ef t on si te acco rd ing to requi remen t/ speci fi cat ion 4
6019 wrist straps used correctly 2
6021 Site clean and tidy 4
1-6113
6101 Internal cables installed correctly 2
6102
Cabinet (and all it s elements) grounding done correctly (cable,
position, stops washer, etc) 2
6103 AC/ DCsupply pow er cables inst alled according to specificat ion 1
6104 External alarms cabling done correctly 2
6108 Unused and used connectors are covered whit IP seals 2
6109 Cab les between BTS modules are rou ted via co rrect cab le en tr ies 3
6110 Flexi WCDMA BTS modules are grounded to the plinth 26111 Cable ties installed properly (no sharp or jagged edges) 4
6112 Spare cable securely t ied and labeled as such. 36113 All connector t ight ened according to specification 2
3-6507
6503 Labeling done according to specifications 4
6504 Alarm panel installed correctly(External) 2
6505 DDF rack installed correctly 1
6506 DDF module installed correct ly 16507 DDF is grounded to the grounding busbar 2
1-6560
6551 Cables preparat ions (str ipping cutt ing ...) according to specif icat ions 2
6552 Cables labeled correct ly 3
6554 Connectors labeled correctly 36555 Cable installed over specified route 4
6557 Connections done correctly according to specifications 2
6559 Cabling done correctly according to specifications 26560 Grounding cable done correct ly according to specificat ions 2
5-6708
6615 OVP instal led co rrect ly 2
6701 Correct antenna types on each sector 2
6703 Ti lt ing (mechanical &/or elect rical ) done accord ing to speci ficat ions 3
6704 Antennas orientation according to specification 2
6705 Antennas properly mounted and secured 2
6708 Equipment painted accord ing to local requi rement and speci ficat ions 4
1-6760
INSTALLATION(ANTENNA)
INSTALLATION(CABINET)
CABLING(INTERNALLY)
INSTALLATION (DDF/ALARM)
CABLING (DDF/ALARM)
Site Quality Checklist for 3G Telecom Implementation
DOCUMENTATI ON
m
mber
Rectified
DateRemarksDescription
Severity
Level
HEALTH & SAFETY GENERAL
CABLING(ANTENNA LINE)
Page 1 of 2
8/3/2019 3g Quality Checklist Ti Ver-001
2/2
6751 Jumper installed correctly 3
6752 Feeder and/ or jum pers inst alled correct ly t hrough cable ent ry 3
6753 Feeder and/or jumpers labeled correctly 4
6754 Connectors installed and tightened correct ly 2
6755 EMPs properly installed and grounded 2
6756 All connectors tightened to specified torque setting 2
6757 Waterproof on connectors according to specifications 3
6758 Ground ing k it s number and posi ti on ing acco rd ing to speci fi cat ions 36759 Grounding kits installed according to specificat ion 2
6760 Feeder installed correctly (bending, clamps, radius, etc) 2
1-6802
6801
Measured Comm issionin g results & parameters are w ith in specified
range 26802 Measures executed with cal ibrated instruments 2
1-7003
7001 Rack(s) installed at specified position 3
7002 Rack(s) secured correct ly 37003 Rack(s) grounded correct ly 2
1-7204
7201 Indoor Unit installed at specified position 3
7202 Indoor Unit grounded correctly 2
7203 Indoor Unit power connection correct 27204 Indoor Un it l abeled co rrect ly 4
1-7311
7301Installation done like shown in the documentation (pole, direction,height,) 3
7302
Alignment unit and antenna are installed properly and screws are
t ightened 2
7303 Antenna polarization according to specifications 1
7304
Coupler & Waveguide is properly m ounted (Separate antenna or HSB
configurat ion) 2
7305 The serial number of the antenna is recorded 3
7306
OU is installed p roperly (screws are tightened, sealing is in right
position, ...) 2
7307 Enough space left for removing Outdoor Unit 4
7308 OU is grounded properly 2
7309 Outdoor Unit labeled according to specifications 4
7310
Installation according to planning data (frequency, polarization, signa
etc) 1
7311 Equipment painted accord ing to local requi rement and speci ficat ions 4
1-7510
7501 Cables properly installed 2
7502 All connectors tightened properly 2
7503 Q1 bus cable properly installed 3
7504
Indoor Unit to Outdoor Unit cables grounding kits properly installed
and waterproofed (including quantity & position) 2
7506 Cables entry glands sealing done properly 3
7507 Cables labeled according to specificat ions 4
7508 OU connector is sealed according to specifications 27509 External PAM cables installed correctly and tested 27510 External Fiber Op ti c cab les i nstal led co rrect ly, cl eaned and tested 2
CABLING betw een ODU & IDU
INSTALLATION(TRANSMISSION RACK)
INSTALLATION I NDOOR UNIT (FIU/ SDH/MUX)
INSTALLATION(ODU/MW )
COMMISSIONING