Commissioning of AN5116-06A Data Service (OLT)

Page 2: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

• Preparation before configuration

• Commissioning of data service

• VLAN configuration of OLT

• Configuration of ONU port

• OLT QINQ domain function

• OLT QINQ domain configuration

• OLT QINQ domain command line

• Note

• FAQ

Agenda

Page 3: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

1. Configure management VLAN

ANM2000 EMS works on the equipment only after management

VLAN and IP configured

Connect the Console port

Configure management VLAN and IP

Page 4: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Use Hyper Terminal software: Enter 【Startup】→【Program】→ 【Accessary】 →【Communications】→【Hyper Terminal】

Connect serial port of PC and CONSOLE port of AN5116-06A with a serial-port cable.

Preparation Before Configuration

Connect the Console port

Page 5: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Before the user enters the console, the system will check his identity.

The user should input right username and password. Configuring management VLAN requires the user to be in configuration mode.

The default name and password of an administrator are GEPON, GEPON and EN, GEPON respectively.

Page 6: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Type “cd service” after command prompt Admin# in configuration mode to get into directory of commands for VLAN management.

To configure management VLAN, use the following command:

set manage vlan name <name> vid <vid> inputport <portlist> [untagged|tagged]

<vid>: VLAN ID of management VLAN, ranging between 1 and 4085.

<portlist>: Port of the management VLAN.

[untagged|tagged]: Specify port of this management VLAN is in Untagged mode or Tagged mode.

Example:

set manage vlan name test vid 1000 inputport 19:4 untagged

Preparation Before Configuration

Configure management VLAN

Page 7: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Configure management IP

Preparation Before Configuration

set manage vlan name <name> ip <A.B.C.D/M> {<A.B.C.D>}*1 <A.B.C.D/M>: IP address of management VLAN, of it M referring to subnet mask bits. {<A.B.C.D>}*1: Equipment gateway, optional (The setting of gateway is necessary only when equipment and EMS fall within different net sections) Example: set manage vlan name test IP 10.18.250.3/16

Page 8: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

2. ANM2000 Basic Configuration-Flow Chart

Preparation Before Configuration

Add Domain

End

Log in ANM2000 and start

basic system configuration

Set Card Authorization

Detect Physical Configuration

Add System

Time Calibration

Add a Module

Enter Edit Mode

Save and Enter Edit Mode Again

Set SNMP Trap Receiver IP and Time Management

Page 9: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Add Domain

Preparation Before Configuration

Right-click the blank at the Logical Tree tab in the browse tree pane, and then select Add Domain… in the shortcut menu to enter the Add Domain dialog box

Page 10: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Add System

Management IP of equipment

Page 11: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Add a Module

Right click added system in the logical tree tab to show its context menu. Click “Add Module” in the menu and a dialog box “Add Module” will pop up.

NOTE: Click “Save” button in the toolbar to save above configuration into the database and enter Edit Mode again.

Page 12: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Detect Physical Configuration

Page 13: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Set Card Authorization

Page 14: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Set SNMP Trap Receiver IP

IP address of EMS

Equipment uses trap receiver IP to report alarms to EMS

Page 15: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Preparation Before Configuration

Set Time Management

IP address of EMS

Set time management for time calibration

Page 16: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Time Calibration

Preparation Before Configuration

Function of time calibration is to keep time of EMS server in agreement with that of the equipment

Page 17: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Commissioning of Data Service

• Preparation before commissioning:

Check whether the status indicator is ready; check ONU is registered or not.

• ONU authentication.

ONU is authenticated using MAC address whitelist.

• Configuration of OLT VLAN.

According to OLT VLAN requirement, choose proper port and configure the VLAN

table for OLT.

• Configure ONU port parameters.

• By clicking “FE port configuration”, configure the ONU VLAN mode.

• Configuration of OLT SVLAN.

According to ONU configuration and OLT requirement, configure the VLAN profile of

OLT QINQ domain.

• ONU binding:

Choose binding ONU, and OLT QINQ profile of PON port.

Page 18: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

• Check the power supply (-48v DC:-40V~-57V), make a data service plan before

powering on the system.

• Make plans for data service, record ONU MAC address and authentication ID.

• Make sure the power supply keep accordance with the requirement of equipment,

make sure the voltage within standard range.

• Check the status indicator of cards

Card works properly when ACT indicator of HSWA card, EC4B card, uplink

card is on.

Communication between ONU and EC4B has been established successfully when

LINK indicator of EC4B card is on.

• Check the type of ONU

Check the software version of cards

Check the connection status of system.

Check the connection between PON port and ONU.

Check the connection of uplink cards.

Check the connection between EMS and HSWA by serial port.

Commissioning of Data Service

Page 19: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

ONU Authentication (1)

•Choose “config”, then “ONU authentication”-> “ONU physic_IDaddress Whitelist”

Page 20: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

ONU Authentication (2)

• Click “Get Unauthorized ONU”.

Page 21: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

ONU authentication (3)

• Choose corresponding Slot No. and PON No., click “Get Unauthorized ONU”.

Page 22: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

ONU authentication (4)

• Choose these ONUs and click “OK”. Then click “Write Device”, after that ONU Authorized No. will be offered automatically by system.

Page 23: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

VLAN Configuration of OLT

• Configuration interface

• Function Configure the parameters of interface on local end, including

service name, type, interface No. and VLAN range, etc.

【HSWA】→ 【Config】 → 【Local VLAN】

Page 24: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT VLAN Configuration

• Parameters introduction Service name Customer can define a specific service name for convenience. Starting VLAN ID Start value of VID range:1-4085 VLAN ID end End value of VID range:1-4085 Interface ID (Uplink port ID or TRUNK ID) XFP:10G optical port SFP:1G optical port GE:10/100/1000M electric port Tag/Untag mode Define VLAN is tagged or untagged Service type Pre-define the type of service

Page 25: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

ONU Port Configuration

• Function Configure the data service of ONU side,

such as CVLAN, SVLAN, etc.

• Configuration • Please refer to “Commissioning of AN5116-

06A Data Service (ONU).PPT”

Page 26: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain Function

• Function introduction

Multiple functions for VLAN tag, VLAN translation and VLAN add of upstream direction.

Corresponding operation of VLAN for downstream direction can be executed, according to that of the upstream direction.

Configuration for upstream and downstream data is enabled, based on which optional operation can be done according to pre-defined parameters.

Operation for VLAN based on PON port and ONU is supported.

COS remarking is supported.

Page 27: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration

•QINQ domain configuration interface

1. Each domain has a certain name.

2. VLAN of four layers can be configured in each domain.

But only the first two layers’ operation are supported currently.

3. Maximum 32 services can be configured in a single domain.

4. Maximum 1024 domain configuration can be supported

currently.

【HSWA】→ 【Config】 → 【QINQ】→ 【OLT QINQ Domain】

Page 28: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration

•QINQ domain parameter introduction •Parameters Serial No.:Maximum 32

Service type:Reserved for future use

Up/down clause:Define the feature of up/downstream packets

Four layers’ VLAN domain:Each layer’s VLAN can be configured according to customer’s requirement, of which only the first two layers’ are supported currently.

• VLAN layer introduction:

First layer VLAN–It can be a CVLAN when upstream data from ONU with one layer’s VLAN, it can be a inner CLVAN when upstream data from ONU has two layers’ VLAN.

Second layer VLAN – It’s outer VLAN, namely SVLAN.

Page 29: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration

•QINQ domain configuration interface

•Each layer’s VLAN parameter

Nth layer’s VLAN of customer:Original VLAN of upstream direction from ONU.

Nth layer’s VLAN COS:COS ID of Nth layer’s VLAN.

Action:Action can be executed for Nth layer’s VLAN, including “add” and “transparent”.

Tag identification:New TPID of Nth layer’s VLAN after the action.

Priority:COS value of new VLAN after the action.

New VID:VID of new VLAN after the action.

Page 30: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration

•PON attach interface

• Binding for each PON port is enabled.

• Each PON port can be bound to multiple domains.

• Multi-cards can share one domain.

• Domain should be either bound to OUN or PON port.

【EC4B】→ 【Config】 → 【PON Attach/Detach Domain】

Page 31: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration

•ONU attach interface

• Multiple domains can be used for binding one ONU.

• Binding of domain for multi-ONUs and multi-PON ports is enabled.

• Note:The domain can’t be used for binding PON port of the line

card if it has been bound for ONU under this line card.

【04ONU】→ 【Config】 → 【ONU Attach/Detach Domain】

Page 32: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Example 1: Use QINQ Domain to create CVLAN=100, SVLAN=1000

Bind QINQ Domain to PON Port

Page 33: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Click to add one Domain

Page 34: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Click again in the right window to add one row

Page 35: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Set Up Clause: VLAN1(CVLAN)=100

Page 36: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Set Down Clause: VLAN2(SVLAN)=1000

Page 37: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Set Old_CVLAN Low=100

Configure 1st Layer’s Parameters

Page 38: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Set Action: Transparent

Page 39: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Set Action: Add

Configure 2nd Layer’s Parameters

Page 40: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Set New VID(SVLAN)=1000

Page 41: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Bind QINQ Domain to PON Port

Page 42: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Bind QINQ Domain to PON Port

Page 43: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Example 2: Use QINQ Domain to create 100≤CVLAN≤200, SVLAN=1000

Bind QINQ Domain to PON Port

Page 44: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Click to add one Domain

Page 45: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Click again in the right window to add one row

Page 46: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Set Up Clause: 100≤VLAN1(CVLAN)≤200

Page 47: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Set Down Clause: VLAN2(SVLAN)=1000

Page 48: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Set Old_CVLAN Low= blank

Configure 1st Layer’s Parameters

Page 49: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example Set Action: Transparent

Page 50: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Set Action: Add

Configure 2nd Layer’s Parameters

Page 51: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Set New VID(SVLAN)=1000

Page 52: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Bind QINQ Domain to PON Port

Page 53: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

OLT QINQ Domain

Configuration Example

Bind QINQ Domain to PON Port

Page 54: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

Note:

• Maximum services of QINQ domain profiles should be less than 22

at each PON port.

• N:1 transform can only be realized by attaching profile to ONU. PON

port does not support N:1 transform unless through other indicators

such as COS.

• OLT QINQ domain requires that VLAN can be processed by

downstream data only after MAC address has been learned by

upstream data

• Instead of supporting broadcast packets from downstream direction,

OLT QINQ domain transmit the packets transparently to the users

without processing VLAN.

Page 55: 3.Commissioning of AN5116-06A Data Service (OLT)

www.fiberhomegroup.com

FAQ

• Service Failure (FTTH ONU)

Check VLAN configuration of OLT and the correctness of SVLAN.

Check the correctness of QINQ domain profile parameters of OLT and VLAN information.

Verify whether VLAN operation is effective by checking MAC address table of equipment.

Check where service failure occurs by CLI