HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Security Level: Internal
Slide title :40-47pt
Slide subtitle :26-30pt
Color::white
Corporate Font :
FrutigerNext LT Medium
Font to be used by customers and
partners :
Arial
www.huawei.com
2009-03
Wireless Case & Training
3900 Series Base Station
GU Co-Cabinet Solution
ISSUE 1.0
HUAWEI TECHNOLOGIES CO., LTD. Page 2Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware configuration principles and software
solutions of 3900 series GU co-cabinet base station
are introduced in this course.
HUAWEI TECHNOLOGIES CO., LTD. Page 3Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Know 3900 series base station GU co-cabinet solution
Master GU co-cabinet hardware and software
configuration principles
Master the precautions of site maintenance
HUAWEI TECHNOLOGIES CO., LTD. Page 4Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
3900 Series Base Station GU Co-Cabinet Solution Guide (V100R001_01)
3900 Series Base Station GU Co-Cabinet Documentation (V100R001_01)
BTS3900 GU Co-Cabinet Installation Guide(V100R001_01)
BTS3900A GU Co-Cabinet Installation Guide(V100R001_01)
HUAWEI TECHNOLOGIES CO., LTD. Page 5Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Chapter 1Chapter 1 Introduction of Co-Cabinet SolutionIntroduction of Co-Cabinet Solution
Chapter 2 Hardware Configuration Principles
Chapter 3 Initial Configuration Principles
Chapter 4 Precautions of Site Maintenance
HUAWEI TECHNOLOGIES CO., LTD. Page 6Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware and Software Solution
Hardware Solution:
GSM and UMTS boards are installed in the same BBU3900, whereas the RF
modules for GSM are independent of those for UMTS, and transmission of Abis
interface is also independent of that of Iub interface.
Software Solution:
Software is classified into GSM software and UMTS software. The software of
the two modes runs independently on the corresponding hardware in BBU3900,
and the communications exist only between the main control units of the two
modes. The electromechanical components such as the power supply unit,
batteries, fans, and environment monitoring unit are controlled by the common
control unit in a centralized manner.
HUAWEI TECHNOLOGIES CO., LTD. Page 7Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Solutions for DBS3900 DBS3900 consists of the BBU3900, RRU3004, and RRU3804. The BBU3900
accommodates GTMU, WMPT, WBBP, UPEU and FAN unit. RF modules for
GSM are independent of those for UMTS, i.e. RRU3004 is used for GSM, and
RRU3804 is used for UMTS. GSM and UMTS share the electromechanical
components, but the transmission of GSM and UMTS is independent.
HUAWEI TECHNOLOGIES CO., LTD. Page 8Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Solutions for BTS3900 BTS3900 consists of the indoor macro
cabinet, BBU3900, DRFU, WRFU,
and electromechanical components.
The BBU3900 accommodates GTMU,
WMPT, WBBP, UPEU, and FAN unit.
The RF modules for GSM are
independent of those for UMTS, i.e.
the DRFU is used for GSM, and the
WRFU is used for UMTS. GSM and
UMTS share the electromechanical
components, but the transmission of
GSM and UMTS is independent.
HUAWEI TECHNOLOGIES CO., LTD. Page 9Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Solutions for BTS3900A BTS3900A consists of APM30 power
cabinet, RF cabinet, transmission
cabinet, BBU3900, DRFU, WRFU, and
electromechanical components. The
BBU3900 accommodates GTMU,
WMPT, WBBP, UPEU, and FAN unit.
The RF modules for GSM are
independent of those for UMTS, i.e. the
DRFU is used for GSM, and the WRFU
is used for UMTS. GSM and UMTS
share the electromechanical
components, but the transmission of
GSM and UMTS is independent.
HUAWEI TECHNOLOGIES CO., LTD. Page 10Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Software Solution Software architecture in GU co-cabinet base station consists of two
completely separate software systems: GSM software and UMTS software.
On M2000, a GU co-cabinet base station is presented as two interrelated
network elements.
HUAWEI TECHNOLOGIES CO., LTD. Page 11Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Equipment Management of GU Co-Cabinet Base Station The equipment management module (also referred to as monitoring
software) manages the common components, processes the data sent
by the GBTS and NodeB, and reports alarms related to the common
components according to the preset rules.
The monitoring software provides a refresh mechanism for the configuration of the
common component data sent by the GBTS and the NodeB. For example, if the
GBTS sends the definition of a Boolean value after the NodeB, the definition sent
by the GBTS overwrites and takes effect. In the case that the GBTS and the
NodeB send different data for the configuration of common components, the GU
co-cabinet base station reports alarms.
HUAWEI TECHNOLOGIES CO., LTD. Page 12Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Equipment Management of GU Co-Cabinet Base Station
The GU co-cabinet base station adopts the preference rule to control the rotation
speed of the common fans. That is, after comparing the data sent by the GBTS
with that sent by the NodeB, the monitoring software will choose the higher speed
to take effect.
The monitoring software reports the dedicated alarms only to the corresponding
side of the base station rather than to the other side. For example, the alarms
generated on the WBBP are reported to the M2000 only through the UMTS
software.
For the alarms of common components, such as fans, power supply unit, and
environment monitoring unit, the monitoring software reports these alarms to both
the GSM software and UMTS software and then to the M2000. Therefore, two
pieces of alarm information of the same common component will be displayed on
the M2000. The main control boards of the GU co-cabinet base station do not
support active/standby switchover.
HUAWEI TECHNOLOGIES CO., LTD. Page 13Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Chapter 1 Introduction of Co-Cabinet Solution
Chapter 2Chapter 2 Hardware Configuration PrinciplesHardware Configuration Principles
Chapter 3 Initial Configuration Principles
Chapter 4 Precautions of Site Maintenance
HUAWEI TECHNOLOGIES CO., LTD. Page 14Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
BBU3900 BBU3900 can be configured with GTMU, WMPT, WBBP, UPEU, UEIU, FAN
unit, etc.
For the 3 types of GU co-cabinet base station, boards configuration of
BBU3900 is the same: GTMU is installed in slots 5 and 6, and WMPT is installed in slot 7.
WBBP can be installed in slot 2 or 3.
HUAWEI TECHNOLOGIES CO., LTD. Page 15Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
BBU3900 Cables Connected to BBU3900:
A CPRI optical cable for GSM connects a CPRI port on GTMU and CPRI_0
(CPRI_W) port on a GSM RF module. A CPRI optical cable for UMTS connects a
CPRI port on WBBP and CPRI_0(CPRI_W) port on a UMTS RF module.
E1 cable for GSM is connected to the E1/T1 port on GTMU. The E1 cable for UMTS
is connected to the E1/T1 port on WMPT.
FE cable: The FE electrical cable or FE optical cable for UMTS is connected to the
FE0 or FE1 port on WMPT respectively.
HUAWEI TECHNOLOGIES CO., LTD. Page 16Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of DBS3900 Typical Configuration:
GSM S4/4/4+UMTS S2/2/2+AC Power:
HUAWEI TECHNOLOGIES CO., LTD. Page 17Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of DBS3900 Typical Configuration:
GSM S4/4/4+UMTS S2/2/2+DC Power:
HUAWEI TECHNOLOGIES CO., LTD. Page 18Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900 Configuration Principles of RF Modules:
If the total number of RF modules is not more than six, configure all the RF
modules will in one cabinet. If the total number of RF modules is more than six,
configure all the WRFUs in the extension cabinet (without BBU) and all the
DRFUs in the main cabinet (with BBU) .
In each cabinet, the DRFUs and WRFUs are alternately installed. For example,
if three DRFUs and three WRFUs need to be installed in a cabinet, the DRFUs
are installed in slots 0, 2, and 4 and the WRFUs are installed in slots 1, 3, and 5.
If there are only three RF modules in the extension cabinet, they should be
installed in slots 0, 2, and 4.
HUAWEI TECHNOLOGIES CO., LTD. Page 19Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900 Typical Configuration:
GSM S2/2/2+UMTS S2/2/2, Single Cabinet:
No. Cable Name
P1~P6 DCDU-RFU power cable
P7 DCDU-FAN power cable
P8 DCDU-BBU power cable
P9 、 P10 -48V power cable
S1~S3 UMTS CPRI cable
S4~S6 GSM CPRI cable
S7 External alarm cable
S8 DCDU-01 monitoring cable
S9 FAN monitoring cable
S10 GSM E1 cable
S11 UMTS E1 cable
R1~R6 GSM RF jumper
R7~R12 UMTS RF jumper
HUAWEI TECHNOLOGIES CO., LTD. Page 20Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900 Typical Configuration:
GSM S4/4/4+UMTS S2/2/2, Cabinet Combination:
No. Cable Name
P1~P6, P11~P13
DCDU-RFU power cable
P7,P14 DCDU-FAN power cable
P8 DCDU-BBU power cable
P9,P10,P15,P16
-48V power cable
S13~S15 UMTS CPRI cable
S1~S6 GSM CPRI cable
S7 GSM E1 cable
S8 UMTS E1 cable
S9 External alarm cable
S10 External alarm cable
S11 FAN monitoring cable
S12 FAN cascade cable
R1~R12 GSM RF jumper
R13~R18 UMTS RF jumper
HUAWEI TECHNOLOGIES CO., LTD. Page 21Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900 Cabling Principles
RF jumpers: RF jumpers are routed inside the cable trough.
In a single cabinet or two cabinets installed side by side, the RF jumpers are routed
inside the cable troughs to the top of the cabinet by default before they are led out of
the cabinet from two sides.
When the cabinets are installed in stack mode, the RF jumpers in the lower cabinet
are routed inside the cable troughs on the two sides of the cabinet, and the RF
jumpers in the upper cabinet are routed upwards and then led out of the cabinet.
HUAWEI TECHNOLOGIES CO., LTD. Page 22Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900 Cabling Principles
Transmission cables: Transmission cables must be routed separately from the -48 V power cables.
Transmission cables are routed along the cable trough on the right of the cabinet
(seen from the front), whereas the -48 V power cables are routed along the cable
trough on the left of the cabinet.
Monitoring signal cables for the DCDU-01 and FAN unit: In a single cabinet, the monitoring signal cables are routed according to the principle of
the shortest path.
When the cabinets are installed in stack mode, the monitoring signal cables are routed
along the cable trough on the right of the cabinet (seen from the front).
When the cabinets are installed side by side, the monitoring signal cables are routed
along the cable trough on the right of the main cabinet (seen from the front) to the top
of the cabinet and then routed downwards along the cable trough on the right of the
extension cabinet.
HUAWEI TECHNOLOGIES CO., LTD. Page 23Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900 Cabling Principles
CPRI cables In a single cabinet or two cabinets in stack mode, the CPRI cables for UMTS are
routed along the cable trough on the left of the cabinet (seen from the front), whereas
the CPRI cables for GSM are routed along the cable trough on the right of the cabinet.
When the cabinets are installed side by side, the CPRI cables for GSM are routed to
the top of the cabinet along the cable trough on the right of the main cabinet (seen
from the front), whereas the CPRI cables for UMTS are routed to the top of the cabinet
along the cable trough on the left of the main cabinet. In the extension cabinet, the
CPRI cables are routed along the cable trough nearest to the main cabinet. That is, if
the extension cabinet is located to the left of the main cabinet, the CPRI cables are
routed along the cable trough on the right of the extension cabinet; if the extension
cabinet is located to the right of the main cabinet, the CPRI cables are routed along
the cable trough on the left of the extension cabinet.
HUAWEI TECHNOLOGIES CO., LTD. Page 24Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900A Configuration Principles of the RF Modules:
If the total number of RF modules is not more than six, configure all the RF
modules in one RF cabinet. If the total number of RF modules is more than six,
configure all the WRFUs in the extension RF cabinet and the DRFUs in the main
RF cabinet.
In a single RF cabinet, the DRFUs and WRFUs are alternately installed. For
example, the DRFUs are installed in slots 0, 2, and 4, and the WRFUs are
installed in slots 1, 3, and 5 of the cabinet. If there are only three RF modules in
the RF cabinet, they should be installed in slots 0, 2, and 4.
HUAWEI TECHNOLOGIES CO., LTD. Page 25Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900A Typical Configuration:
GSM S2/2/2+UMTS S2/2/2:
No. Cable Name
L1, L2, L3, N Input power cable
P0 Input power cable for batteries
P2.1~P2.3 DCDU-DRFU power cable
P3.1~P3.3 DCDU-WRFU power cable
T1.1~T1.3 UMTS CPRI cable
T6 UMTS E1 cable
T7 UMTS E1 lightningproof transfer cable
T2.1~T2.3 GSM CPRI cable
T4 GSM E1 cable
T5 GSM E1 lightningproof transfer cable
S1 FMUA-BBU monitoring cable
S4 APMI-BBU monitoring cable
S5 Environment monitoring cable
S6 PMU-APMI monitoring cable
R1.1~6, R2.1~6 RF jumper
HUAWEI TECHNOLOGIES CO., LTD. Page 26Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900A Typical Configuration:
GSM S4/4/4+UMTS S2/2/2:No. Cable Name
L1, L2, L3, N Input power cable
P0 Input power cable for batteries
P2.1~P2.6 DCDU-DRFU power cable
P3.1~P3.3 DCDU-WRFU power cable
P6.1, P6.2 PDU-DCDU power cable
T1.1~T1.3 UMTS CPRI cable
T6 UMTS E1 cable
T7 UMTS E1 lightningproof transfer cable
T2.1~T2.6 GSM CPRI cable
T4 GSM E1 cable
T5 GSM E1 lightningproof transfer cable
S1 FMUA-BBU monitoring cable
S4 APMI-BBU monitoring cable
S5 Environment monitoring cable
S6 PMU-APMI monitoring cable
S10 Monitoring cable for cascade FMUAs
R1.1~6, 2.1~8 RF jumper
HUAWEI TECHNOLOGIES CO., LTD. Page 27Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900A Cabling Principles:
The usage of cable holes: The round cable holes are used for the cables between APM30 and RF cabinets in
stack mode.
The rectangular cable holes of APM30 cabinets are used for external cables when
the APM30 is installed in stack mode.
The three rectangular cable holes on each side at the bottom of the RF cabinet are
used for feeders, and the rectangular cable hole in the bottom middle of the RF
cabinet is used for CPRI cables, power cables, and signal cables.
If an RF cabinet is installed separately as a remote unit, the round and rectangular
cable holes at the top of the RF cabinet will not be used.
HUAWEI TECHNOLOGIES CO., LTD. Page 28Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900A Cabling Principles:
CPRI cables: When the APM30 is stacked on an RF cabinet, the CPRI cables are led through the
round cable hole on the left of the APM30.
When two RF cabinets are installed, the routing of the CPRI cables to the extension RF cabinet is as follows: The CPRI cables are led into the RF cabinet under the APM30 through the round cable hole on the APM30. After led through the rectangular cable hole in the bottom middle of the RF cabinet, the CPRI cables are led into the base and then through the rectangular cable hole in the bottom middle of the extension RF cabinet.
Monitoring signal cables of RF cabinet: For a single RF cabinet on which the APM30 is stacked, the monitoring signal cables
are routed downwards along the cable trough on the right of the APM30 (seen from the front). After leading through the round cable hole on the right of the APM30, the monitoring signal cables are connected to the FMUA in the RF cabinet.
When two RF cabinets are installed, the signal cable between the cascaded RF cabinets is led from one cabinet to the other through the rectangular cable hole in the middle of each RF cabinet.
HUAWEI TECHNOLOGIES CO., LTD. Page 29Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Hardware Configuration of BTS3900A Cabling Principles:
Power cables of RF cabinet: For a single RF cabinet on which the APM30 is stacked, the power cables are routed
downwards along the cable trough on the right of the APM30 (seen from the front).
After leading through the round cable hole on the right of the APM30, the power
cables are connected to the DCDUs in the RF cabinet.
When two RF cabinets are installed, the routing of the power cables to the extension
RF cabinet is as follows: The power cables are routed along the right of the APM30,
through the rectangular cable hole on the right of the APM30, and then along the
support at the bottom. After leading through the cable hole in the bottom middle of
the RF cabinet, the power cables are connected to the DCDUs.
Equipotential cables: The equipotential cable is routed through the round cable holes on the left of the
APM30 and RF cabinets.
The equipotential cable is routed through the rectangular cable holes on the left of
the transmission and RF cabinets.
HUAWEI TECHNOLOGIES CO., LTD. Page 30Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Chapter 1 Introduction of Co-Cabinet Solution
Chapter 2 Hardware Configuration Principles
Chapter 3Chapter 3 Initial Configuration PrinciplesInitial Configuration Principles
Chapter 4 Precautions of Site Maintenance
HUAWEI TECHNOLOGIES CO., LTD. Page 31Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Initial Configuration Principles Configuration of the Common Components:
The common components are the fans, PMU, FMU, EMUA, etc. They are
separately configured for GBTS and NodeB. The configuration data takes effect
in compliance with the following rules: The GU co-cabinet base station adopts the preference rule to control the rotation
speed of the common fans. That is, after comparing the data sent by the GBTS with
that sent by the NodeB, the monitoring software will choose the higher speed to take
effect.
The data that takes effect is the data ultimately configured for GSM or UMTS.
Therefore, the common components should be configured for both the GBTS and the
NodeB, and all the related parameters should be set in accordance with the default
GSM data. (For the NodeB, users can manually configure a template data file
beforehand and create configuration files on the basis of this template.)
If the parameters configured for GBTS and NodeB are inconsistent, both the GBTS
and the NodeB report a configuration conflict alarm.
HUAWEI TECHNOLOGIES CO., LTD. Page 32Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Initial Configuration Principles Configuration of the Common Resources:
The external input alarms related to the sensors, such as the door status
sensor, water sensor, smoke sensor, and infrared sensor are separately
configured for the GBTS and NodeB. The configuration data takes effect in
compliance with the following rules: The data that takes effect is the data ultimately configured for GSM or UMTS.
Therefore, the external input alarms should be configured for both the GBTS and the
NodeB, and all the related parameters should be set in accordance with the GSM
data. (For the NodeB, users can manually configure a template data file beforehand
and create configuration files on the basis of this template.)
If the parameters configured for the GBTS and NodeB are inconsistent, both the
GBTS and the NodeB report a configuration conflict alarm.
HUAWEI TECHNOLOGIES CO., LTD. Page 33Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Initial Configuration Principles Configuration of the Transmission and Services:
The transmission and services are separately configured for the GBTS and
NodeB. Configuration of the transmission and services for the GBTS part of the
GU co-cabinet base station is the same as that for the GSM-only base station.
Note that No.0 E1 on the GTMU must be configured, because timeslot 31 of
No.0 E1 is used for the OM channel.
Configuration of the transmission and services for the NodeB part of the GU co-
cabinet base station is the same as that for the UMTS-only base station. The
NodeB supports inter-board IMA. Each IMA group supports a maximum of four
IMA links (E1s).
Configuration of License:
The licenses should be configured separately according to the GSM and UMTS
service capabilities.
HUAWEI TECHNOLOGIES CO., LTD. Page 34Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Chapter 1 Introduction of Co-Cabinet Solution
Chapter 2 Hardware Configuration Principles
Chapter 3 Initial Configuration Principles
Chapter 4Chapter 4 Precautions of Site MaintenancePrecautions of Site Maintenance
HUAWEI TECHNOLOGIES CO., LTD. Page 35Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Precautions of Site Maintenance Boards:
Both WMPT and GTMU boards do not support active/standby switchover.
The clock source of the GBTS is independent of that of the NodeB. The GBTS and the NodeB extract the clock source from their own trunk cable.
When the working reference clock of the BBU3900 is provided by the WMPT, resetting of the WMPT board will not affect the current and subsequent services of the GBTS, and vice versa.
When the working reference clock of the BBU3900 is provided by the WMPT, unplugging and plugging the WMPT board will disrupt the current services of the GBTS but will not affect the subsequent services of the GBTS , and vice versa.
The operation and maintenance of the RF modules on the GBTS and NodeB can be performed separately. The operation and maintenance on the GBTS or NodeB do not affect the running of its counterpart.
HUAWEI TECHNOLOGIES CO., LTD. Page 36Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Precautions of Site Maintenance Common Resources: The common resources are jointly controlled and managed by
the GBTS and NodeB. When performing the operation and maintenance of the common resources, pay attention to the following items:
The configuration data of the common resources must be synchronously modified on the GBTS and NodeB.
The alarms are simultaneously reported to the GBTS and NodeB.
Common Components: The common components are jointly controlled and managed by the GBTS and NodeB. When performing the operation and maintenance of the common components, pay attention to the following items:
Both the GBTS and the NodeB manage the external equipment. Therefore, when you reset the GBTS, the external equipment will also be reset and the NodeB will report an alarm indicating that the external equipment is abnormal. After the restart of the external equipment, the external equipment abnormal alarm will be cleared on the NodeB. The same problem occurs on the GBTS if the NodeB is reset.
Transmission and Services: The operation and maintenance of the transmission and services on the GBTS and NodeB
are performed separately. The operation and maintenance on the GBTS or NodeB will not affect the running of its counterpart.
HUAWEI TECHNOLOGIES CO., LTD. Page 37Huawei Confidential
Slide title :32-35pt Color: R153 G0 B0
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
Slide text :20-22ptBullets level 2-5:
18pt Color:Black
Corporate Font :FrutigerNext LT Medium
Font to be used by customers and partners :
Arial
3900 series base station GU co-cabinet solution
GU co-cabinet hardware and software configuration principles
Precautions of site maintenance
Thank youwww.huawei.com