WHAT’S INCLUDED NOTE: ITEMS IN LIST WILL BE SHIPPED SEPARATELY CHECKLIST #8 WHITE HEAD SCREWS THRU WIRE PLUGS JOINING KIT LENS REMOVAL TOOL + JOINER CLIPS ALIGNER TABS LENS REMOVAL TOOL THRU WIRE PLUG ALIGNER TOOL ALIGNER TOOL #8 WHITE HEAD SCREW ALIGNER TABS JOINER CLIPS THRU WIRE PLUGS THRU WIRE CONNECTORS FIXTURE TO BE INSTALLED INSTALLED FIXTURE ROW MOUNTED FIXTURES - FLANGE CEILING (RG6 MODELS SHOWN) EXPLODED VIEW 1 10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316 RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8) WARNINGS RISK OF ELECTRICAL SHOCK OR FIRE - DISCONNECT POWER DURING INSTALLATION / SERVICING. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION. INSTALL & WIRE IN ACCORDANCE TO ALL NATIONAL & LOCAL CODES BY A CERTIFIED ELECTRICIAN. FIXTURE MAY BE SHARP - HANDLE WITH CARE. LET FIXTURE COOL BEFORE MAINTENANCE. 2 2013 Rev A NOTE: END CAPS ARE NOT FACTORY INSTALLED ON ROW FIXTURES. SEE STEPS 6 AND 7. JOINING KIT REMOVE ALL PACKAGING PRIOR TO INSTALLATION 2 1 END CAP END CAP APPLIES TO -3/8” TO 1 ” RIGID CEILING 1/4 GENTLY BREAK APART

3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

WHAT’S INCLUDED NOTE: ITEMS INLIST WILL BE

SHIPPEDSEPARATELY

CHECKLIST

#8 WHITE HEAD SCREWS

THRU WIRE PLUGS

JOINING KIT

LENS REMOVAL TOOL

+

JOINERCLIPS

ALIGNERTABS

LENS REMOVAL TOOL

THRU WIRE PLUG

ALIGNERTOOL

ALIGNER TOOL

#8 WHITE HEAD SCREW

ALIGNERTABS

JOINERCLIPS

THRU WIRE PLUGS

THRU WIRECONNECTORS

FIXTURE TO BE INSTALLED

INSTALLED FIXTURE

ROW MOUNTED FIXTURES - FLANGE CEILING(RG6 MODELS SHOWN)

EXPLODED VIEW

1

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

WARNINGSRISK OF ELECTRICAL SHOCK OR FIRE - DISCONNECT POWER DURING INSTALLATION / SERVICING.

READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.INSTALL & WIRE IN ACCORDANCE TO ALL NATIONAL & LOCAL CODES BY A CERTIFIED ELECTRICIAN.

FIXTURE MAY BE SHARP - HANDLE WITH CARE.LET FIXTURE COOL BEFORE MAINTENANCE.

2

2013 Rev A

NOTE: END CAPS ARE NOTFACTORY INSTALLED ON ROWFIXTURES. SEE STEPS 6 AND 7.

JOINING KIT

REMOVE ALL PACKAGINGPRIOR TO INSTALLATION

2

1

END CAP

END CAP

APPLIES TO -3/8” TO 1 ” RIGID CEILING1/4

GENTLY BREAKAPART

Page 2: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

4

3 ATTACHING JIG TO CEILING

CUTTING INSTALLATION

2013 Rev A

(1) MARK THE START OF THE ROW

(2) MARK THE CENTERLINE OF THE ROW

(3) INSTALL COARSE THREADDRYWALL SCREW ON CENTERLINESPACED 2” FROM START OF ROW.

(5) LIFT CUTTING JIG INTO POSITIONOVER THE FIRST SCREWS. SLIDE

SO THAT THE SCREWS ARE IN THENARROW END OF THE KEY HOLES

IN THE JIG.

NOTE: THE OBROUND CUTOUTSSHOULD BE AWAY FROM THE

START OF THE ROW.

USE 1/8” DRYWALL BIT AGAINST THE EDGEOF THE JIG. START AT THE BEGINNING OF

THE ROW AND TRACE THE JIG. ONE PERSONCUTS WHILE A SECOND PERSON HOLDS

THE CUT END FROM FALLING OUT. 1/8” DRYWALL BIT1/2” OR 5/8” DRYWALL

CUTTING JIGGUARD ISATTACHED

OBROUND HOLES CLOSEST TO THE KEYHOLEMARKS THE END OF A ROW INSTALLATION. IT

MAKES THE OPENING 5/8” LONGER THAN ROWTO ALLOW THE LAST FIXTURE INTO THE CEILING.

OBROUND HOLES FARTHEST FROMTHE KEYHOLE DO NO APPLY TO

THIS INSTRUCTION SHEET.

ROTO ZIP(OR SIMILIAR TOOL)

USE OBROUND SLOT TOMARK CUT LINE. DO NOT

TRY TO CUT THRU SLOTS.

(4) INSTALL COARSE THREADDRYWALL SCREWS ON CENTERLINESPACED 24” FROM SCREW IN STEP 3

ON CENTER DOWN THE ENTIRELENGTH OF THE ROW.

Page 3: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

5 CUTTING INSTALLATION

END CAP INSTALLATION

2013 Rev A

RF2-... RF4-... RF6-...

2.75” 3.75” 5.75”

HOLE WIDTHS

REMOVE CUT CEILINGWITH JIG ATTACHED

6FIRST / LAST FIXTURE IN ROW

SLIDE END CAPINTO THE FIXTURE

Page 4: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

8

7 END CAP INSTALLATION

FIXTURE INSTALLATION

2013 Rev A

FIRST / LAST INSTALLEDFIXTURE IN ROW

END CAP TAB WILL SNAP INTO SLOT

ON HOUSING

NOTE: THIS OPERATION WILLREQUIRE FORCE. AVOID DEFORMING

END CAP AND HOUSING SHEET METAL

INSTALL #8 WHITE HEADSCREWS AFTER END CAP

HAS SNAPPED INTO PLACE.

A

INSERT ALIGNMENT TABSUNTIL POINT ON TAB

STOPS INWARD MOVEMENT

DETAIL A

LUMINAIRE POWER DISCONNECT

CODE COMPLIANT, FACTORYINSTALLED POWER DISCONNECT

Input Side Daisy ChainConductor Types:

Power Side - solid / stranded19 strands (MIN.)

Ballast Side - 18 AWG solid

1. WARNING - ELECTRICAL SHOCK or FIRE - Disconnect power.2. Wire per all National and Local electrical codes. Remove access cover or knock- out and connect power feed conduit.3. Make proper electrical connection and re-install access cover.

INSERT THE LONGER ENDOF ALIGNMENT TABS INTOEXTRUSION SLOT OF THEFIXTURE TO BE INSTALLED

EXTRUSION SLOT

REPEAT FOR ALL OTHERFIXTURES IN ROW

FIXTURE TO BE INSTALLED

INSERT THRU WIRE PLUGSINTO THRU WIRE CONNECTORSON FIXTURE TO BE INSTALLED

MAKE SURE END CAP FLANGELINES UP WITH EXTRUSION EDGEAFTER SCREWS ARE INSTALLED.

Page 5: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

9 FIXTURE INSTALLATION

FIXTURE INSTALLATION

2013 Rev A

10

NEXT, PUSH YOKE BOLTHEAD UP UNTIL YOKELEGS SNAP OUT OVER

DRYWALLFIRST, BOTTOM OUTFLANGE ON CEILING

SURFACE

INSERT FIXTURE INTOCEILING HOLE

FIRST INSTALLEDFIXTURE IN ROW

FIRST INSTALLEDFIXTURE IN ROW

AFTER YOKE LEGS HAVE SPRUNGOUTWARDS, THE FIXTURE WILL REST

ABOUT 1” BELOW THE CEILING.

AMOUNT OF YOKES PER FIXTURE: 2’/3’/4’ FIXTURE - 2 YOKES 6’/8’ FIXTURE - 3 YOKES

1. WARNING - ELECTRICAL STOCK OR FIRE - Disconnect power.2. Clean hands before handling the luminaire or use clean gloves.3. Secure luminaire per all codes. Instead of Yoke (provided): - All-thread (SBO) can be secured to structure and passed through 1/4-20 hole

- Air craft cable (SBO) can be secured to structure and passed though 1/4-20 hole

AFTER SHIFTING THE FIXTURE TO THE EDGEOF THE CEILING CUT, ONLY TIGHTEN THE

YOKE BOLT ON THE END CAPPED SIDE OF THEFIXTURE UNTIL FLANGE IS TIGHT TO CEILING.

TIGHTEN ALL YOKE BOLTS ON PREVIOUSFIXTURE ONCE NEXT FIXTURE IS INSTALLED.

NOTE: LIFT THEN SHIFT.FIXTURE SHOULD BE SETAGAINST THE EDGE OFTHE CEILING SLOT.

FIRST INSTALLEDFIXTURE IN ROW

FIRST INSTALLEDFIXTURE IN ROW

Page 6: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

12

11 FIXTURE INSTALLATION

FIXTURE INSTALLATION

2013 Rev A

NOTE: REPEAT STEPS 9 AND 10 FOR ALL OTHERFIXTURES IN ROW, EXCEPT FOR LAST FIXTURE.

SIMULTANEOUSLY CONNECT: 1. THRU WIRE PLUGS TO THRU WIRE CONNECTORS 2. ALIGNMENT TABS INTO EXTRUSION SLOT

FIXTURE TO BE INSTALLED INSTALLED FIXTURE

PLACE UPPER TAB OF ALIGNERTOOL UNDERNEATH EXTURSION

PLACE SIDE TAB OF ALIGNER TOOLON TOP EDGE OF JOINER CLIP

ROTATE UNTIL JOINERCLIP “SNAPS” INTO PLACE

REPEAT FOR OTHER SIDE

NOTE: VIEWED FROM INSIDE THE FIXTURE

Page 7: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

14

13FIXTURE INSTALLATION

FIXTURE INSTALLATION

2013 Rev A

1. WARNING - ELECTRICAL STOCK OR FIRE - Disconnect power.2. Clean hands before handling the luminaire or use clean gloves.3. Fold out pry out grid hookd to center and secure luminaire over ceiling grid. Set hook to match T-bar height.4. Secure luminaire per all codes. Holes are provided for tie back to structure (tie wire by others). Code may require seismic stabilizing, shown above (1/4” TEK screw by other).

NOTE: VIEWED FROM INSIDE THE FIXTURE

REPEAT FOR OTHER SIDE

FINAL RESTING POSITIONOF JOINER CLIP

SEQUENCE OF YOKE BOLT TIGHTENING

NEXT YOKE BOLTS TO BE TIGHTENED

FIRST YOKE BOLT PREVIOUSLY TIGHTENED

YOKE BOLTS TO BE TIGHTENED AFTERNEXT FIXTURE IN ROW IS INSTALLED

HOLD ALIGNER TOOL BETWEENHOUSING BEING TIGHTEN TOAVOID HOUSING DISTORTION

Page 8: 3/8” TO 1 ” RIGID CEILING 1/4 WARNINGS RISK OF ELECTRICAL … · 2014. 7. 10. · recessed - installation and maintenance instructions regolo series (2, 3, 4, 6, 8) warnings risk

10770 East 51st Ave, Denver, CO 80239 Phone (303)287-9646 Fax (303)287-0316

RECESSED - INSTALLATION and MAINTENANCE INSTRUCTIONS REGOLO Series (2, 3, 4, 6, 8)

16

15 FIXTURE INSTALLATION

LENS REMOVALTOOL

1. WARNING - ELECTRICAL SHOCK or FIRE - Disconnect power.2. Gently insert lens removal tool at one end of the lens and pull down. Grab the exposed end and remove lens.3. Install appropriate lamp(s) and re-install the lens.4. Clean - Wipe down luminaire with a clean damp rag.5. Connect power and make sure luminaire works properly.

LAMP INSTALLATION, MAINTENANCE and CLEANING

2013 Rev A

LENS REMOVAL TOOL