Upload
exclusive-lighting-solutions
View
215
Download
0
Embed Size (px)
DESCRIPTION
monitor lights in different areas. Function Pre-Wiring Specifications Master keypads can be programmed with Windows-based software or locally by being placed in manual programming mode.* Dimensions in mm Installation For additional submittal sheets, call our Hot Line and Fax-on-Demand Service at 1-800-523-9466 or visit Lutron's Website at http://www.lutron.com/resi Scene or Zone Buttons A L UT R O N S P E C I F I C AT I O N S U B M ITT A L Scene or Monitor Indicator LEDs HWV-KP-LB9 t 1 234
Citation preview
Sceneor ZoneButtons
Dimensionsin mm
AAAAA 2.75 70
BBBBB 4.64 116
CCCCC .32 8
DDDDD .84 21
Location
Job Name
t
Job Number
Area Controlled
Model No./ColorHWV-KP-LB6, KP-LB9
Pre-Wiring1. Mount wallbox.
2. Pull cable(s) from HomeWorksPanel or other master keypadlocation. Use one pair #18 for powerand one pair twisted, shielded#18 - #22 for data. All wires areclass 2.
ProgrammingMaster keypads can beprogrammed with Windows-basedsoftware or locally by being placedin manual programming mode.*
FunctionThese keypads allow users to:
� turn individual scenes/zones onor off.
� turn selected scenes/zones onor off as a group.
� raise/lower selected scenes/zones as a group.
� monitor lights in different areas.
Master KeypadL U T R O N S P E C I F I C A T I O N S U B M I T T A L
HWV-KP-LB6KP-LB9
t
WHite BEige IVory GRay BRown BLack
Dusty Rose TauPe
ArchitecturalStyleKeypads
SpecificationsPOWER Operating Voltage: class 2, 15VDCTERMINALS Capacity: (4) #18 AWG (1.0 mm2).
MOUNTING 1 or 2 gang US wallbox.
ENVIRONMENTAL 32 - 104oF (0 - 40oC).
DESIGN Faceplates: Molded plastic (8 std. colors listed above).
SYSTEM 32 controls max with 16 possible unique addresses.CAPACITY Data link: 1000' (300 m) maximum.
Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036, USA4/96 P/N 362-917
Installation1. Turn power off. Strip 1/2" (12 mm)insulation from wires in wallbox.Connect pair for low-voltage power toterminals 1 and 2. Connect twistedpair for data link to 3 and 4.
2. ADDRESS: Set six switches onback of unit. Set first 4 switches withunit's unique address (see back ofsheet). For normal use, set switches5 and 6 in down (off) position. Forraise/lower operation, changebuttons 5 and 10 to Raise/Lower bysetting the DIP Switch 6 in the up (on)position.
3. MOUNT: Push all wires in wallboxand mount as shown. Restore power.
tt
Scene orZoneButtons
Scene orMonitorIndicatorLEDs
HWV-KP-LB6 Scene orMonitorIndicatorLEDs
For additional submittal sheets, call ourHot Line and Fax-on-Demand Serviceat 1-800-523-9466 or visit Lutron'sWebsite at http://www.lutron.com/resi
Addressswitches1 - 6
MUX
MUX
+15V
COM
A t
t
Class 2 wiringconnectionsto other keypads orHomeWorks panel
1
2 3
4
1 2
3 4
5 6
HWV-KP-LB9
* Remote Power Modules can only beprogrammed to master keypads with theWindows-based software.
t
t
Giving Master Keypads Their Unique Address
Each Master Keypadshould have a uniquesystem address (1-16).This identifies thekeypad and enables it tocommunicate with theHomeWorks panel.
To give a Master Keypadits address, set switches1 - 4 on the back of theunit as shown at right.Document yourassignments by notingwhich keypadcorresponds to whichaddress.
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
Set switches*like this
t
1 2 3 4
© 1996 Lutron Electronics Co., Inc.
* Switch position key:
= UP;
= DOWN.
Warranty
Lutron will, at its option, repair or replace anycontrol that is defective in materials ormanufacture within two years after the purchase.This warranty is in lieu of any other warranties,express or implied and the implied warranty ofmerchantability is limited to two yearsfrom purchase.This warranty does not cover the cost ofinstallation, removal or reinstallation, or damageresulting from misuse, abuse or improper wiring orinsulation.This warranty gives you specific legal rights, andyou may also have other rights which vary fromstate to state. Some states do not allow theexclusion or limitation of incidental orconsequential damages or limitations on how longan implied warranty may last, so the abovelimitations and exclusions may not apply to you.
Printed in U.S.A
Set switches*like this
t
For thisaddress
t
For thisaddress
1 2 3 4
t
t
t
t
s
Overview of HomeWorks Integrated System
t
Preferred Feed andLoad Wiring Entry
Optional High InductanceFilter Choke Locations
Terminal Blocks handle 8 RPMModules, 4 Lighting zones permodule
RPM Module locations(8 maximum)
Low voltage relay card location
Microprocessor Assemblylocation (HW-MA-8-120)
Alternate Load Wiring Entries
GRAFIK Eye System8 GRAFIK Eye 3100Up to 15 Accessory Controls
Master Keypad Controls32 Controls maximum with16 possible unique addresses
Local Control Dimmers/Switches12 Buses - 4 devices each
LocalControls canswitch or dimzone lightingand overrideprogrammedsettings.
t t t
1111122222
3333344444
6666655555
8888877777
t
Master Keypads can enablepre-programmed lighting scenes,pathways of light; raise or lower lights,motor-driven accessories.
t
t
t
t
Control Wiring Entry (Class 2)
tInterpanel LinkTo Next Panel
(max. 8 panels)
(Typical of 12 buses)