2
Scene or Zone Buttons Dimensions in mm A 2.75 70 B 4.64 116 C .32 8 D .84 21 Location Job Name t Job Number Area Controlled Model No./Color HWV-KP-LB6, KP-LB9 Pre-Wiring 1. Mount wallbox. 2. Pull cable(s) from HomeWorks Panel or other master keypad location. Use one pair #18 for power and one pair twisted, shielded #18 - #22 for data. All wires are class 2. Programming Master keypads can be programmed with Windows-based software or locally by being placed in manual programming mode.* Function These keypads allow users to: turn individual scenes/zones on or off. turn selected scenes/zones on or off as a group. raise/lower selected scenes/ zones as a group. monitor lights in different areas. Master Keypad L U T R O N S P E C I F I C A T I O N S U B M I T T A L HWV- KP-LB6 KP-LB9 t WHite BEige IVory GRay BRown BLack Dusty Rose Tau Pe Architectural Style Keypads Specifications POWER Operating Voltage: class 2, 15VDC TERMINALS Capacity: (4) #18 AWG (1.0 mm 2 ). MOUNTING 1 or 2 gang US wallbox. ENVIRONMENTAL 32 - 104 o F (0 - 40 o C). DESIGN Faceplates: Molded plastic (8 std. colors listed above). SYSTEM 32 controls max with 16 possible unique addresses. CAPACITY Data link: 1000' (300 m) maximum. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036, USA 4/96 P/N 362-917 Installation 1. Turn power off. Strip 1/2" (12 mm) insulation from wires in wallbox. Connect pair for low-voltage power to terminals 1 and 2. Connect twisted pair for data link to 3 and 4. 2. ADDRESS: Set six switches on back of unit. Set first 4 switches with unit's unique address (see back of sheet). For normal use, set switches 5 and 6 in down (off) position. For raise/lower operation, change buttons 5 and 10 to Raise/Lower by setting the DIP Switch 6 in the up (on) position. 3. MOUNT: Push all wires in wallbox and mount as shown. Restore power. t t Scene or Zone Buttons Scene or Monitor Indicator LEDs HWV-KP-LB6 Scene or Monitor Indicator LEDs For additional submittal sheets, call our Hot Line and Fax-on-Demand Service at 1-800-523-9466 or visit Lutron's Website at http://www.lutron.com/resi Address switches 1 - 6 MUX MUX +15V COM A t t Class 2 wiring connections to other keypads or HomeWorks panel 1 2 3 4 1 2 3 4 5 6 HWV-KP-LB9 * Remote Power Modules can only be programmed to master keypads with the Windows-based software. t t

362-917

Embed Size (px)

DESCRIPTION

monitor lights in different areas. Function Pre-Wiring Specifications Master keypads can be programmed with Windows-based software or locally by being placed in manual programming mode.* Dimensions in mm Installation For additional submittal sheets, call our Hot Line and Fax-on-Demand Service at 1-800-523-9466 or visit Lutron's Website at http://www.lutron.com/resi Scene or Zone Buttons A L UT R O N S P E C I F I C AT I O N S U B M ITT A L Scene or Monitor Indicator LEDs HWV-KP-LB9 t 1 234

Citation preview

Page 1: 362-917

Sceneor ZoneButtons

Dimensionsin mm

AAAAA 2.75 70

BBBBB 4.64 116

CCCCC .32 8

DDDDD .84 21

Location

Job Name

t

Job Number

Area Controlled

Model No./ColorHWV-KP-LB6, KP-LB9

Pre-Wiring1. Mount wallbox.

2. Pull cable(s) from HomeWorksPanel or other master keypadlocation. Use one pair #18 for powerand one pair twisted, shielded#18 - #22 for data. All wires areclass 2.

ProgrammingMaster keypads can beprogrammed with Windows-basedsoftware or locally by being placedin manual programming mode.*

FunctionThese keypads allow users to:

� turn individual scenes/zones onor off.

� turn selected scenes/zones onor off as a group.

� raise/lower selected scenes/zones as a group.

� monitor lights in different areas.

Master KeypadL U T R O N S P E C I F I C A T I O N S U B M I T T A L

HWV-KP-LB6KP-LB9

t

WHite BEige IVory GRay BRown BLack

Dusty Rose TauPe

ArchitecturalStyleKeypads

SpecificationsPOWER Operating Voltage: class 2, 15VDCTERMINALS Capacity: (4) #18 AWG (1.0 mm2).

MOUNTING 1 or 2 gang US wallbox.

ENVIRONMENTAL 32 - 104oF (0 - 40oC).

DESIGN Faceplates: Molded plastic (8 std. colors listed above).

SYSTEM 32 controls max with 16 possible unique addresses.CAPACITY Data link: 1000' (300 m) maximum.

Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036, USA4/96 P/N 362-917

Installation1. Turn power off. Strip 1/2" (12 mm)insulation from wires in wallbox.Connect pair for low-voltage power toterminals 1 and 2. Connect twistedpair for data link to 3 and 4.

2. ADDRESS: Set six switches onback of unit. Set first 4 switches withunit's unique address (see back ofsheet). For normal use, set switches5 and 6 in down (off) position. Forraise/lower operation, changebuttons 5 and 10 to Raise/Lower bysetting the DIP Switch 6 in the up (on)position.

3. MOUNT: Push all wires in wallboxand mount as shown. Restore power.

tt

Scene orZoneButtons

Scene orMonitorIndicatorLEDs

HWV-KP-LB6 Scene orMonitorIndicatorLEDs

For additional submittal sheets, call ourHot Line and Fax-on-Demand Serviceat 1-800-523-9466 or visit Lutron'sWebsite at http://www.lutron.com/resi

Addressswitches1 - 6

MUX

MUX

+15V

COM

A t

t

Class 2 wiringconnectionsto other keypads orHomeWorks panel

1

2 3

4

1 2

3 4

5 6

HWV-KP-LB9

* Remote Power Modules can only beprogrammed to master keypads with theWindows-based software.

t

t

Page 2: 362-917

Giving Master Keypads Their Unique Address

Each Master Keypadshould have a uniquesystem address (1-16).This identifies thekeypad and enables it tocommunicate with theHomeWorks panel.

To give a Master Keypadits address, set switches1 - 4 on the back of theunit as shown at right.Document yourassignments by notingwhich keypadcorresponds to whichaddress.

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

Set switches*like this

t

1 2 3 4

© 1996 Lutron Electronics Co., Inc.

* Switch position key:

= UP;

= DOWN.

Warranty

Lutron will, at its option, repair or replace anycontrol that is defective in materials ormanufacture within two years after the purchase.This warranty is in lieu of any other warranties,express or implied and the implied warranty ofmerchantability is limited to two yearsfrom purchase.This warranty does not cover the cost ofinstallation, removal or reinstallation, or damageresulting from misuse, abuse or improper wiring orinsulation.This warranty gives you specific legal rights, andyou may also have other rights which vary fromstate to state. Some states do not allow theexclusion or limitation of incidental orconsequential damages or limitations on how longan implied warranty may last, so the abovelimitations and exclusions may not apply to you.

Printed in U.S.A

Set switches*like this

t

For thisaddress

t

For thisaddress

1 2 3 4

t

t

t

t

s

Overview of HomeWorks Integrated System

t

Preferred Feed andLoad Wiring Entry

Optional High InductanceFilter Choke Locations

Terminal Blocks handle 8 RPMModules, 4 Lighting zones permodule

RPM Module locations(8 maximum)

Low voltage relay card location

Microprocessor Assemblylocation (HW-MA-8-120)

Alternate Load Wiring Entries

GRAFIK Eye System8 GRAFIK Eye 3100Up to 15 Accessory Controls

Master Keypad Controls32 Controls maximum with16 possible unique addresses

Local Control Dimmers/Switches12 Buses - 4 devices each

LocalControls canswitch or dimzone lightingand overrideprogrammedsettings.

t t t

1111122222

3333344444

6666655555

8888877777

t

Master Keypads can enablepre-programmed lighting scenes,pathways of light; raise or lower lights,motor-driven accessories.

t

t

t

t

Control Wiring Entry (Class 2)

tInterpanel LinkTo Next Panel

(max. 8 panels)

(Typical of 12 buses)