1
L C CABLE W.C. W.C. W.C. BAGGAGE FAN ROOM FAN ROOM EL. UP LIFT UP DN W.C. W.C. DWN DWN 5 10 15 5 10 AIR CONDITION ROOM AIR CONDITION ROOM CORRIDOR 2 CREW 2 CREW 2 CREW 2 CREW W.C. W.C. W.C. 2 CREW BATTERY ROOM A 2 CREW 2 CREW (EXISTING) (EXISTING) 2 CREW 15 20 20 AIR CONDITION ROOM (NEW) AIR CONDITION ROOM (NEW) W.C. W.C. 2 CREW 2 CREW 2 CREW 2 CREW BATTERY ROOM B GOLAR HILLI FLNG 9 - A Golar LNG 6 F I L T E R H E A T E R F I L T E R H E A T E R P G/S DECT: G/S DECT: WEATHER LOUVER C/W INSECT SCREEN O[\¶ kv~u mh k|j{P SS 316 MIST ELIMINATOR FRESH AIR FILTER F&G DAMPER BULK HEAD PENETRATION E E E E E E PDT PDI PDT PDI PDT PDT PDI PDI P P E FRESH AIR EXHAUST AIR E E E EAF-SAN-O1 EAF-SAN-O2 NRD NRD NRD NRD F&G D F&G D NRD NRD NRD NRD NRD NRD VCD VCD M I X I N G B O X M I X I N G B O X C . C O I L C . C O I L AT 3RD POOP DECK AT 3RD POOP DECK SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR SUPPLY AIR E EXHAUST AIR E E E EAF-PB-O1 EAF-PB-O2 NRD NRD NRD NRD SUPPLY AIR SUPPLY AIR EXHAUST AIR P F&G D ACCOMMODATION AHU P F&G D EXHAUST AIR SUPPLY AIR RETURN AIR PDT PDI E VCD F I L T E R H E A T E R C . C O I L M I X I N G BOX E G/S DECT: G/S DECT: WEATHER LOUVER C/W INSECT SCREEN O[\¶ kv~u mhTk|j{P SS 316 MIST ELIMINATOR FRESH AIR FILTER F&G DAMPER BULK HEAD PENETRATION FRESH AIR PDT PDI P E AT 1ST DECK ELECTRICAL COMPARTMENT AHU NRD NRD NRD PDT PDI VCD F I L T E R H E A T E R C . C O I L M I X I N G BOX E PDT PDI NRD E NRD E NRD SUPPLY AIR TO UPS, TELECOM, INSTRUMENT ROOMS ACCOMMODATION AHU GALLEY AHU ACCOMMODATION AHU P F&G D P F&G D RETURN AIR FROM UPS, TELECOM, INSTRUMENT ROOMS RETURN AIR FROM UPS, TELECOM, INSTRUMENT ROOMS

Document3

Embed Size (px)

DESCRIPTION

sample

Citation preview

Page 1: Document3

LC

CABLE

W.C.

W.C.

W.C.

BAGGAGE

FAN ROOM

FAN ROOM

EL.

UP

LIFT

UP

DN

W.C.

W.C.

DWN

DWN

5

10

15

5

10

AIR CONDITION ROOM

AIR CONDITION ROOM

CORRIDOR

2 CREW

2 CREW

2 CREW

2 CREW

W.C.

W.C.

W.C.

2 CREW

BATTERY ROOM A

2 CREW

2 CREW

(EXISTING)

(EXISTING)

2 CREW

15

20

20

AIR CONDITION ROOM(NEW)

AIR CONDITION ROOM(NEW)

W.C.

W.C.

2 CREW

2 CREW

2 CREW

2 CREW

BATTERY ROOM B

GOLAR HILLI FLNG

9

-

A

Golar LNG

6

FILTER

HEATER

FILTER

HEATER

PG/SDECT:

G/SDECT:

WEATHER LOUVER C/WINSECT SCREEN

(45° DOWN FA DUCT)

SS 316MIST ELIMINATOR

FRESH AIRFILTER

F&G DAMPER

BULK HEADPENETRATION

E

E

E

E

E

E

PDT

PDI

PDT

PDI

PDT PDT

PDI PDI

P

P

E

FRESH AIR

EXHAUST AIR

E

E

E EAF-SAN-O1

EAF-SAN-O2

NRD

NRD

NRD

NRD

F&G D

F&G D

NRD

NRD

NRD

NRD

NRD

NRD

VCD

VCD

MIXING

BOX

MIXING

BOX

C.

COIL

C.

COIL

AT 3RD POOP DECK

AT 3RD POOP DECK

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

SUPPLY AIR

E

EXHAUST AIR

E

E

EEAF-PB-O1

EAF-PB-O2

NRD

NRD

NRD

NRD

SUPPLY AIR

SUPPLY AIR

EXHAUST AIR

P

F&G D

ACCOMMODATION AHU

P

F&G D

EXHAUST AIR

SUPPLY AIR

RETURN AIR

PDT

PDI

E

VCD

FILTER

HEATER

C.COIL

MI

XI

NG

BOX

E

G/SDECT:

G/SDECT:

WEATHER LOUVER C/WINSECT SCREEN

(45° DOWN FA-DUCT)

SS 316MIST ELIMINATOR

FRESH AIRFILTER

F&G DAMPER

BULK HEADPENETRATION

FRESH AIR

PDT

PDI

P

E

AT 1ST DECK

ELECTRICAL COMPARTMENT AHU

NRD

NRD

NRD

PDT

PDI

VCD

FILTER

HEATER

C.COIL

MI

XI

NG

BOX

E

PDT

PDI

NRD

E

NRD

E

NRD

SUPPLY AIR TO UPS,TELECOM,INSTRUMENT ROOMS

ACCO

MMODATIO

N

AHU

GALL

EY

AHU

ACCO

MMODATIO

N

AHU

P

F&G D P

F&G D

RETURN AIR FROM UPS, TELECOM, INSTRUMENT ROOMS